Loading...
HomeMy WebLinkAboutAPPROVED REVISION, ENERGY LOT 45FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: KHOV-EMERALD Builder Name: KHOVNANAIN HOMES Streev 5165 ARMINA PL, Permit Office: City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: EMERALD MODEL LOT 45 @ WATERSTONE Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing 2. Single family or muftiple family 3. Number of units, if multiple family 4. Number of Bedrooms S. Is this a worst case? 6. Conditioned floor area above grade (ft2) Conditioned floor area below grade (ft2) 7. Windows(194.6 sgft.) Description a. U-Factor. D61, U=0.30 SHGC: SHGC=0.28 b. U-Factor- Dbi, U=0.55 SHGC: SHGC=0.34 c. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth Area Weighted Average SHGC: 8. skylights c. U-i-actor:(AVG) NIA SIIGC(AVG): NIA 9. Floor Types (1354.1 sqft-) a. Siab-On-Grade Edge Insulation b. Raisz;d Floor c. WA New (From Plans) 10. Wall Type$2508.8 sqft.) Insulation Detached a. Frame - Wood, Exterior R=11.0 b. Concrete Block - lnt Insul, Exterior R=4.1 1 c. Frame - Wood, Adjacent R=11.0 5 d. NIA R= No 11. Ceiling Types (1354.0 sgft.) Insulation a. Under Attic (Vented) R=30.0 2321 b. NIA R= 0 c. NIA R= Area 12. Ducts ++ a. Sup: Attic, Ret: HALL LOFT, AH: HALL LOFT 152.00 ftz l; 42.00 ft2 ft2 3.165 ft. 0.293 Area ft2 Insulation Area R=0.0 968.10 ft2 R=11.0 386.00 ft2 R= ft2 13. Cooling systems a. Central Unit 14. Heating systems a. Electric Strip Heat 15. Hot water systems a. Electric b. Conservation features None 16. Credits Glass/Boor Area: 0.084 Total Proposed Modified Loads: 70.47 Total Baseline _oads: 71.88 hereby certify that the plans and speci ations covered by this calculation are in compliance with t Florida Energy - Code. PREPARE E� DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code, OWNIERIAGENT: DA-, Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: Area 1180.70 ft2 973.39 ft2 354.67 ft2 ft2 Area 1354.00 ft2 ft2 ft2 R ft2 6 260 kBtu/hr Efficiency 46.5 SEERA6.00 kBtu/hr Efficiency 32.0 COP:1.00 Cap: 50 gallons EF: 0.950 Pstat PASS - Cor.'.pliance requires certifica `on by the air handier unit manufacturer that the air handier enclosure qualifies as certified f2etc.ry-sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection ( hecklist in accordance with R402.4.1.1 and this project requires an envrelr,pe leakage test report with envelope leakage no greater t ian 7.00 ACH50 (R402.4.1.2). 6/15;2021 3:43 PM EnergyGaugeO USA 7.0.00 - FlaRes2020 FSC 7th Edition (2020) Compliant Software Page 1 of 6 FORM R405-2020 INPUT ,SUMMARY CHECKLIST REPORT PROJECT Title: KHOV-EMERALD Bedrooms: 5 Address Type: Street Address Building Type: User Conditioned Area: 2321 Lot # Owner Name: EMERALD MODEL LOT 45 Total Stories: 2 Block/Subdivision: # or Units: 1 Worst Case: No PlatBook: Builder Name: KHOVNANAIN HOMES Rotate Angle: 0 9 Street: 5165 ARMINA PL. Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Detached New/Existing: New (From Plans) FL, Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2321 19341.E SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil !D Finished Cooled Heated 1 EXTRA SUITE 144 1267.2 No 2 5 1 No Yes Yes 2 EX SUITE BATH 60 528 No 0 1 No Yes Yes 3 FOYER 133 1173 No 0 1 No Yes Yes 4 GRT DIN KITCHEN 630 5544 No 1 1 No Yes Yes 5 BED 4 174 1392 No 1 1 No Yes Yes 6 3ED 3 167 1334 No 1 No Yes Yes 7 3=D 2 162 1296 No i 1 No Yes Yes 8 i ALL _OFT 350 2800 No 0 1 No Yes Yes 9 ' ".UNDRY 48 384 No 0 1 Nc Yes Yes 0 JIASTER SUITE 224 1792 No 2 1 No Yes Yes 1 )AAST WIC 60 476' No 0 1 No Yes Yes 12 MASTER BATH 104 832 No 0 1 No Yes Yes 13 HALL BATH 65 518 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value ,area Joist R-V21U9 Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio EXTRA SUITE 24 ft 0 144.8 ft2 ---- 0 1 0 2 Slab-On=Grade Eoge Insulatio EX SUITE BATH 6 ft 0 60 ft2 ---- C 1 0 3 Slab -On -Glade Edge Insulatio FOYER 20.5 ft 0 133.3 ft2 _ -- 1 0 0 I 4 Slab -On -Grade Edge Insulatio GRT DIN KITCHE 89 ft 0 630 ft2 0.5 0.5 0 6/15/2021 3:43 PM EnergyGaugeD USA 7.0,00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Raised Floor BED 4 -___ ____ 174 ft2 11 0 0 1 6 liaised Floor i BED 3 ____ ____ 167 ft2 11 0 0 1 7 Raised Floor HALL LOFT __-- 45 ft2 11 0 0 1 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor, Tested Tested Insul- (deg) rlip Composition shingies 1466 ft2 0 ft2 Medium N 0.9 No 09 No 0 22.62 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1353 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area 'I Under Attic (Vented) BED 4 30 Blown 174 ft2 2 Under Attic (Vented) BED 3 30 Blown 167 ft2 3 Under Attic (Vented) BED 2 30 Blown 162 ft2 4 Under Attic (Vented) HALL LOFT 30 Blown 350 ft2 5 Under Attic (Vented) LAUNDRY 30 Blown 48 ft2 6 Under Attic (Vented) MASTER SUITE 30 Blown 224 ft2 7 Under Attic (Vented) MAST WIC 30 Blown 60 ft2 8 Under Attic (Vented) MASTER BATH 30 Blown 104 ft2 9 Jrc:. r Attic (Vented) HALL BATH 30 Blown 65 ft2 WALLS -,/Omit Ac, �acent� T6 Wall 4P., Cavity Space R-Vah Width EtInFt Height _ In &rn? z 1 = Exte; or Concrete Block- Int InsEXTRA SUIT 4.1 10 8 9 4 99.6 ft2 2 S Extet ar Concrete Block - Int insOXTRA SUIT 4.1 11 8 10 0 116.7 ft2 3 S Exterior Concrete Block - Int tns6K SUITE BA 4.1 5 5 10 0 54.2 ft2 4 E Exter or Concrete Block -- Int Insul FOYER 4.1 6 9 9 4 63.0 ft2 5 N Exter,o{ Concreta Block - Int Insi2RT DIN KIT 4.1 17 5 9 4 162.6 ft2 6 S Exterior Concrete Block - Int InsCt1RT DIN KIT 4.1 16 2 10 0 161.7 ft2 7 W Exterior Concrete Block - Int InsGRT DIN KIT 4.1 33 10 9 4 315.8 ft2 8 N. Exterior Frame - Wood BED 4 11 13 8 8 10 120.7 ft2 9 E Exterior Frame - Wood BED 4 11 10 11 8 10 96.4 f€2 10 = Exter,or Frame - Wood BED 3 11 10 11 8 10 96.4 ft2 11 E Exterior Frame - Wood BED 2 11 10 11 8 10 96.4 ft2 12 S Exterior Frame - Wood BED 2 11 12 3 8 10 108.2 ft2 13 IN Exterior Frame - Wood HALL LOFT 11 7 3 8 10 64.0 ft2 Framing Frac Truss T} 0.1 Wood 0.1 Wood 0.1 Wood 0.1 Wood 0.1 Wood 0.1 Woad 0.1 Wood 0A Wood 0.1 Wood Sheathing Framing _ Solar saro Below 0 0 0.5 o 0 0 0.5 0 0 0 0.5 0 0 0 0.5 0 0 0 0.5 0 0 0 0.5 0 0 0 0.5 0 0 0 0.5 0 0 0 0.5 0 0 0 0.5 0 0 0 0.5 0 0 0 0.5 0 0 0 0.5 0 6/15,2021 3:43 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 14 S Exterior Frame - Wood HALL LOFT 11 12 9 8 10 112.6 fix 0 0 0.5 15 N Exterior Frame - Wood MASTER SUI 11 13 2 8 10 116.3 ft2 0 0 0.5 0 0 16 W Exterior Frame - Wood MASTER SUI 11 14 7 8 10 128.8 ft2 0 0 0.5 0 17 W Exterior Frame - Wood MASTER BA 11 11 10 8 10 104.5 W 0 0 0.5 0 18 5 Exterior Frame - Wood HALL BATH 11 10 0 8 10 88.3 ft2 0 0 0.5 0 19 W Exterior Frame - Wood HALL BATH 11 5 5 8 10 47,8 ft2 0 0 0.5 0 �20 W Garage Frame - Wood GIRT DIN KIT 11 38 0 9 4 354.7 ft2 0 0 0.5 0 DOORS Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In E Insulated FOYER None .39 3 4 6 8 22,2 ft2 E ti1,le0d FOYER None .39 3 4 6 8 22.2 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang 1/ # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 1 Metal Double (Tinted) Yes 0.3 0.28 N 15.0 ft2 1 ft 0 in 12 ft 0 in None None 2 W 7 Metal Double (Tinted) Yes 0.3 0.28 N 32.0 ft' 1 ft 0 in 12 ft 0 in None None 3 VV 7 Metal Double (Tinted) Yes 0.55 0,34 N 42.0 ft2 11 ft 0 in 1 ft 0 in None None 4 E 5 Metal Double (Tinted) Yes 0.3 0.28 N 15.0 ft2 1 ft 0 in 1 ft 0 in None None 5 E 10 Metai Double (Tinted) Yes 0.3 0.28 N 15.0 ft' 1 ft 0 in 1 ft 0 in None None 6 E 11 Metal Double (Tinted) Yes 0.3 0.28 N 15.0 ft2 1 ft 0 in 1 ft 0 in None None 7 N 13 Metal Double (Tinted) Yes 0.3 0.28 N 15.0 ft2 1 ft 0 in 1 ft 0 in None None 8 S 14 Metal Double (Tinted) Yes 0.3 0.28 N 15.0 ft' 1 ft 0 in 1 ft 0 in None None 9 W 16 Meta: Double (Tinted) Yes 0.3 0.28 N 30.0 ft2 1 ft 0 in 1 ft 0 in None None GARAGE Floor Area Ceiling Area Exposed Wail Perimeter Avg. Wall Height Exposed Wail Insulation 1 386 ft2 386 ft2 64 ft g ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 6/16/2021 3:43 PM EnergyGaugeO USA 7.0.00 - Fl2Res2020 FBC 7th Edition (2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # 1 System Type Electric Strip Heat/ Subtype None Speed Efficiency Capacity C0P:1 32 kBtu/hr Block 1 Ducts sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 46.5 kBtu/hr cfm 0.74 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert ## Company Name System Model # Collector Model # Area Volume FEF None None W DUCTS / 'Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # 1 Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 41 1 Attic 6 250 ft2 HALL LOFT 1 ft2 Default Leakage HALL LOFT (Default) {Default} TEMKE ATURES Programable Thermostat: Y Ceiling Fans: Cooling r Heating [X Venti rr Jar, JanX] j] Feb FebX Mar Mar Apr f AprI j[ ] May ]May1 Xj Jun Jun X Jul Jul rj Au Aug Seg �Xj Se Oct Oct Nov XNovX Dec Dec .g j Jar Feb Jlar [X Apr tt ] Ma % Jun Jul Au Se Oct [X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Tyne 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 80 78 78 78 78 78 78 78 78 80 80 80 80 78 78 78 78 78 78 78 78 Cooling kVVEr-q AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating lVD) AM PM 66 68 66 68 56 68 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 Heating ;+PdE"-I) AM PIM 63 68 66 66 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture fraction Space Default(8 lbs/sq.ft. 0 ftz 0 ft 0.3 BED 2 Default(8 lbs/sq.ft. ft2 ft 0.3 BATH 2 Defaul(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY Dera,id . ss/sq. t. ft- ft 0.3 KITCHEN Dera,J�8 ,asfsq. t. ft2 ft 0.3 GREAT ROOM Defau 48 Inslsq.ft. ft2 ft 0.3 WIC MASTER Defaui:i8 !oslsq.tt. ft2 ft 0.3 MASTER BATH Default(8 lbs/sq.ft. ft2 ft 0.3 TIOLET MASTER 611512021 3:43 PM EnergyGaugeg USA 7.&00 - FiaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6 FORM R405-2020 T SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibsls .ft. ft2 ft 0.3 MASTER SUITE 6/15/2021 3:43 PM EnergyGauge'J USA 7,0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. 5165 ARMINA PL., FORT PIERCE, FL, 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Frame - Wood, Exterior R=11.0 1180.70 ft2 b. Concrete Block - Int Insul, Exterior R=4.1 973.39 ft2 3. Number of units, if multiple family 1 c Frame -Wood, Adjacent 11.0 .354.67 ft2 4. Number of Bedrooms 5 d. NIA R= ftz 5. Is this a worst case? No 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 1354-00 ft2 6. Conditioned floor area (ft2) 2321 b. N/A R= ft2 7. Windows- Description Area c. NIA R= ftz a. 1-1-Factor: Dbl, U=0.30 152.00 ft2 12. Ducts, location & insulation level R ft2 SHGC: SHGC=0.28 a. Sup: Attic, Ret: MALL LOFT, AH: HALL LOFT 6 250 b. U-Factor Dbl, U=0.55 42.00 ft2 SHGC: SHGC=D.34 13. Cooling systems kBtulhr Efficiency c. U-Factor: NIA ftz a. Central Unit 46.5 SEER:16.00 SHGC; d. U-r=actor NIA ft2 SyGC: 14. Heating systems kBtulhr Efficiency Area Ih'eighted Average Overhang Depth: 3.165 ft. a. Electric Strip Heat 32.0 COP:1.00 Area Weighted Average SHGC: 0.293 8. Skylights Description Area 15. Hot water systems a. U-Factor{AVG}: NIA 2 ft2 a. Electric Cap: 50 gallons SHGCtAVG): NIA EF:0.95 b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 968.10 ft2 Credits (Performance method) Pstat b. Raised Floor R=11.0 386.00 ft2 c. tart. R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code camplfant features. Builder Signature: Address cl New Jlome: Date: City/FL Zip: *No.e: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Enq.-;y ;.onservadon, contact the Florida Building Commission's support staff, *"`Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 6/15/2021 3:43 FM EnergyGal USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1