Loading...
HomeMy WebLinkAboutBuilding Plans1. All work shall comply with FL Building Code 7th Edition (2020). National Electric Code Wall Type (see wall type schedule) (2017), fire department regulations, utilty company standards, and the best trade Iola Door Type (see door schedule) practices. 2. The General Contractor shall arrange all inspections and tests as specified or required by Window Type (see window schedule) the building department and shall pay all costs and fees for same. The Contractor shall secure all building permits and upon completion of the project (prior to final payment) 41 1 Building Section deliver to the Owner a Certificate of Occupancy or Use from the building department. �A101) 3. All plumbing and electrical work shall be performed by State licensed contractors. 1 Wall Section Contractors shall submit all required permits, certificates, and sign -offs to Owner and �A101) Engineer for their records. 4. The General Contractor shall verify all dimensions, be familiar with the existing conditions, A1o1 Detail Number and bring any discrepancies to the attention of the Engineer prior to submission of construction proposal and before beginning work. The Drawings reflect conditions reasonably inferred from the existing visible conditions but cannot guaranteed by the 1 Building Elevation Engineer. Drawings may be scaled for estimating purposes and for general reference only. For all other dimensions or locations consult the Engineer or refer to dimensions on Drawings. Verify all dimensions in the field. Interior Elevation 5. The General Contractor shall lay out all work and be responsible for all dimensions and conditions for trades such as electrical, plumbing, etc. +2'-0" Elevation Mark 6. The General Contractor shall provide and maintain access to the premises at all times. 7. The Construction Manager shall make the premises secure from the elements and ROOM Room Name/ Number 5-6-11 trespass on a daily basis. 8. The General Contractor shall keep the construction site free and clear of all debris and Column Line keep out all unauthorized persons. Upon completion of Work, the entire construction area is to be thoroughly cleaned and prepared for occupancy by Owner. All materials and debris Centerline resulting from the Contractor's work shall be removed from the site and disposed of properly. Care shall be taken during construction that no debris or materials are deposited 3 Revision Tag in any Right of Way area. 9. The General Contractor shall be responsible for protecting all existing and new conditions and materials on the site. Any damage caused by or during the execution of the Work is A.C.I. AMERICAN CONCRETE INSTITUTE the Contractor's responsibility and shall be repaired to the Owner's satisfaction at the BLDG. BUILDING Contractor's expense. CONC. CONCRETE C.J. CONTROL JOINT 10. No cutting or damage to building structural components will be allowed without written COL. COLUMN authorization from the Engineer. DET. DETAIL DIA. DIAMETER 11. All utilities shall be connected to provide gas, electric, and water to all equipment whether DN. DOWN said equipment is in Contract or not. Equipment shall be guaranteed to function properly EL/ELEV. ELEVATION upon completion. ELEC. ELECTRICAL EQ. EQUAL :12. Manufacturer's standard specifications and materials approved for project use are hereby FIN. FINISH made part of these Notes with same force and effect as if written out in full herein. All FLR. FLOOR appliances, fixtures, equipment, hardware, etc, shall be installed in accordance with GALV. GALVANIZED Manufacturer's specifications and procedures. GYP. GYPSUM I.D. INSIDE DIAMETER 13. Written words take precedence over drawn lines. Large-scale details and plans take JT. JOINT precedence over smaller details and plans. Should a conflict arrive between the MECH. MECHANICAL Specifications and Drawings, the requirements deemed most stringent shall be used. MIN. MINIMUM N.T.S. NOT TO SCALE 14. Minor details not usually shown or specified but necessary for proper and acceptable NO. NUMBER construction, installation, or operation of any part of the Work as determined by the O.C. ON CENTER Engineer shall be included in the Work as if it were specified or indicated on the Drawings, OPG. OPENING O.D OUTSIDE DIAMETER 15. All Engineerural drawings and construction notes are complimentary. What is indicated U.N.O. UNLESS NOTED OTHERWISE and called for by one shall be binding as though called for by all. REF. REFERENCE R. RISER 16. No deviation from the Drawings or Specifications or intent of same shall be made without R.O. ROUGH OPENING the Engineer's written authorization. RM. ROOM S/STL. STAINLESS STEEL :17. All Work shall be guaranteed for one year after final approval. The General Contractor shall STRUCT. STRUCTURAL sign the written guarantee as provided by the Owner. The guarantee shall cover all general SPEC. SPECIFICATIONS and subcontractor work. All defects discovered during this period shall be repaired to the T.O. TOP OF ( ... ) Owner's satisfaction at the Contractor's expense. T.O.CONC, TOP OF CONCRETE T.O.F. TOP OF FRAMING 18. All dimensions are to face of stud or centerline of structure unless otherwise noted (UON). T.O.STL. TOP OF STEEL T.O.W. TOP OF WALL 19. Door and window details are indicated on the Door and Window Schedules. T. TREAD TYP. TYPICAL 20. Door and window dimensions are to centerlines of units UNO. @ AT + AND BD. BOARD A.F.F. ABOVE FINISHED FLOOR U.N.O. UNLESS OTHERWISE NOTED V.I.F VERIFY IN FIELD DRAWING aIsr} IG GENERAL NOTES K'S PLAN AND ELEVATIONS CE ELECTRIC Basic Buildine Structural Information This table was prepared using Windload Calculator Plus Software available from www.windcales-com This information was created in accordance with Chapter 16 of the 2020 Florida Building Code. The Component and Cladding Pressures were generated using the method in Part 2 of Chapter 30 of ASCE 7-16. Floor & Roof Live Loads S - Storage Warehouses (Light) Floor Live Loads All Floors: 125 psf tunifoini, 1000 lbs concentrated Roof Live Loads Roofs- 20 psf uniform; 2000 lbs concentrated (Balcoliv and Deck live loads are 150% of the adiacent space served.) Wind Design Data Ultimate Wind Speed: 160 inpli Nominal Wind Speed: 124 mph Risk Catewry,: 11 Wind Exposure: B Enclosure Classification: Enclosed End Zone Width (0.6h): 9.60 ft. Internal Pressure Coefficient: 0.18 Roof Geometrv: Flat Roof Slope: 1.011112 (4.80) Mean Roof Height: 16 ft. (The Ultimate Wind speed was used to determine the Component and Cladding design pressures.) (This Building is in a Wind -Bonne Debris Region. and all exterior glazed openings shall be protected from wind-borne debris.) Components and Cladding Roof Zone 1: +16.6psf uiax,. -65.3psf min. Roof Zone F- + 16.6 psf max., -_'37.5 psf min. Roof Zone 2: +16.6 psf max.. -86.2 psf nim. Roof Zone 3: + 16.6 psf max.. - 117.4 psf min. Overhang at Roof Zone 1: -59.0 psf nisi. Overhang at Roof Zone F: -59.0 psf min. Overhang at Roof Zone 2: -79.9 psf min. Overhang at Roof Zone 3: -111.2 psf min. Wall Zone 4- +41.0 psf max.. -44.5 psf 111111. Wall Zone 5: +41.0 psf max.- -54.9 psf mini. Design Soil Bearing Capacity: 2,000 psf 7 PRESTIGE POOL PLASTERING: WAREHOUSE RENOVATION 3810 CR-611 B, FORT PIERCE, FL 34981 07122102 21-007 GENERAL NOTES As indicated - Author ( FLOOR PLAN m LU' n) SCALE: A �LE -: 1/8" 1'- 0 ROOF SHEATHING TO BE REPLACED WITH 26 GA. STEEL PANELS 12" Tr I 1 1. 1 WEST ELEVATION SCALE: 1/8" = 1'-0" EXISTING SHEATHING TO BE REPLACED WITH 24 GA. STRUCTURAL STEEL PANELS Roof 16t - Oil Roof 161 - Oil Floor -Floor &--� of -off kN EA 7!13ION vck"717 SCALE: 1/8" = 1'-0" _ZPv_rN v RIG unjur-munvunju iu rrviA nmivu nvL-rc. NORTH ELEVATION 1'-0" SOUTH ELEVATION cc 'j SCALE: 1/8" = 1'-0" .1 . 4 . .1 . 4 C4 C4 7' jv'4 tvi 7w C4 (4 7" 1 1 f2� SEE ME CLASSIC ROOF SIDE LAP FASTENER SPACING ["ETAIL FOR SIDE LAP FASTENER SPACING \ END LAP HIGH EAVE,_ RIDGE END LAP IF REQUIRED STRUCTURAL FASTENER MK. H 1030 ------- \ IC 14 IL C-4 11-. 9 1/2* 9 1/2- 1 2 ..nt�9 INTEWEDIATE PURLIN the E4 I" ■v *C4 0"E 3`1" IC-4 cq 4 C41 in I r') "I 1 10) 1 CM C4 LOW EAVE I END OF PANEL-j EAVE MEMBER (VARIES). EA" E -LOW EAVE STRUT SHOWN FOR REFEREINCIE ROOF b"'i"TRUCTURAL FASTENER SCALE: 1" = N.T.S - Roof__5� 16' - Oil Floor of - off Roof 161 - Oil -Floor of -Oil 111060 STITC H FASTENER f 1040 STRUCT uRAL FASTEN �7 a a El 13 EAVE PANEL ----SIDE LAP GIRL'S RIDGE OR HI 060 AT EACH HIGH EAVE! PURLIN 0( M MID AT 30* O.C. MAX. `_INTERMEDIATE BETWEEN PURLIN SUPPORTS END LAP PURLIN BASE (IF END LAP IS REQUIRED) MEMBER INTERMEDIATE PURLIN CLASSI c" WALL PANEL SCALE: I" = N.T.S PRESTIGE POOL PLASTERING: WAREHOUSE RENOVATION 3810 C R-61 I B, FORT PIERCE, FL 34981 7125121 21-007 LA4141 II A .7 -p STATE OF C) .41— tOR /CNAL P L - A N A 0� ELEVATIONS G E N E R A L E L E C T R I C A L N O T E S=______________ THESE NOTES APPLY TO ENTIRE PROJECT: A. CODES. ALL ELECTRICAL WORK SHALL COMPLY WITH THE DRAWINGS AND SPECIFICATIONS, THE NATIONAL ELECTRICAL CODE AND APPLICABLE LOCAL CODES, WHICHEVER IS MORE STRINGENT. B. CONDUCTORS. ALL CONDUCTORS ARE TO BE COPPER THWN UNLESS OTHERWISE SHOWN OR REQUIRED BY CODES. ALL POWER CONDUITS ARE TO CONTAIN A GROUND WIRE. C. RACEWAYS. RIGID GALVANIZED CONDUIT AND SCHEDULE 80 PVC ARE TO BE USED. D. SHOP DRAWINGS. SHOP DRAWINGS SHALL BE SUBMITTED TO ENGINEER FOR MATERIALS. E. POWER COMPANY. THE ELECTRICAL CONTRACTOR IS TO COORDINATE ALL SERVICE REQUIREMENTS WITH THE POWER COMPANY BEFORE BIDDING TO BE CERTAIN ALL WORK NECESSARY TO MEET POWER COMPANY SPECIFICATIONS IS IN THE BID. ALL ELECTRICAL GEAR SHALL BE APPROVED BY THE POWER COMPANY. THE ELECTRICAL CONTRACTOR SHALL MEET WITH THE POWER COMPANY PRIOR TO BIDDING TO DETERMINE ALL FEATURES, FUNCTIONS AND LOCATIONS OF SERVICE. FURTHERMORE, THE ELECTRICAL CONTRACTOR IS TO MAINTAIN CONTINUOUS CONTACT WITH THE POWER COMPANY DURING THE PROJECT, AND IS TO NOTIFY THE ENGINEER IMMEDIATELY OF ANY CHANGE PROPOSED. THE ELECTRICAL CONTRACTOR SHALL COORDINATE THE SERVICE THOROUGHLY AND DOCUMENT THE COORDINATION. F. DRAWINGS. THE ELECTRICAL CONTRACTOR IS TO OBTAIN A COMPLETE SET OF DRAWINGS AND SPECIFICATIONS PRIOR TO BIDDING, AND IS TO 13ECOME THOROUGHLY FAMILIAR WITH THE CIVIL AND LANDSCAPING FEATURES OF THE PROJECT. PRIOR TO BIDDING, THE ELECTRICAL CONTRACTOR IS TO HAVE A COMPLETE UNDERSTANDING OF DEMOLITION REQUIREMENTS, TEMPORARY POWER REQUIREMENTS, PIPING, PLUMBING AND ALL OTHER FEATURES WHICH BEAR ON THE ELECTRICAL WORK. UNDER NO CONDITION IS THIS PROJECT TO BE BID WITHOUT A COMPLETE SET OF DRAWINGS AND SPECIFICATIONS. G. SCALES. DO NOT SCALE OR TAKE DIMENSIONS FROM ELECTRICAL DRAWINGS. H. MAIN DISCONNECTS. MAIN DISCONNECTS MAY BE HEAVY DUTY FUSED SWITCHES OR CIRCUIT BREAKERS PROPERLY COORDINATED. FUSES ARE TO BE BUSSMAN TYPE LPN-R, LPS-R, OR KRP-C. CIRCUIT BREAKERS ARE TO BE RATED FOR THE AIC SHORT CIRCUITS INDICATED. I. UNDERGROUND WORK. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DETERMINING THE EXACT ROUTES OF ALL UNDERGROUND WORK. ROUTES SHOWN ARE ,APPROXIMATE. POWER, TELEPHONE, CABLE COMPANIES, AND ALL OTHER UTILITY COMPANIES SHALL BE CONSULTED, AND LINES SHALL BE STAKED. DIGGING BY HAND IS REQUIRED AROUND EXISTING UTILITIES. J. TVSS. THE POWER SERVICE IS TO BE PROTECTED FROM LIGHTNING WITH SURGE SUPPRESSORS THROUGH A 30A (3P) BREAKER (42,000AIC). THREE PHASE TO BE EATON CPS-100-A. K. COMPLETION REQUIREMENTS. WITHIN 30 DAYS AFTER SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED BY THE CONTRACTOR TO BUILDING OWNER WITH A SINGLE LINE DIAGRAM OF THE DISTRIBUTION SYSTEM PLUS FLOOR PLANS SHOWING LOCATIONS AND AREAS SERVED. L. OPERATING AND MAINTENANCE MANUALS. OPERATING AND MAINTENANCE MANUALS FOR EACH PIECE OF EQUIPMENT SHALL BE TURNED OVER BY THE CONTRACTOR TO OWNER WITH SUBMITTAL DATA AND REQUIRED MAINTENANCE PROCEDURES. THE NAME AND ADDRESS OF A QUALIFIED SERVICE AGENCY SHALL BE PROVIDED. M. SHARED NEUTRALS. WHENEVER THE CONTRACTOR USES SHARED NEUTRALS, BREAKERS ARE TO HAVE A COMMON HANDLE (I.E. 2 POLE OR 3 POLE). N. GFCI. OUTLETS INSTALLED OUTDOORS, WITHIN 6' OF A SINK, AND OTHERWISE REQUIRED BY CODE ARE TO BE ON GFCI TYPE CIRCUIT BREAKERS. TO EXISTING FPL TRANSFORMERS EXISTING METAL BUILDING NEW METER NEW 200A / 14KAIC, NEMA 3R 200A 120/240V PANEL TWO 5/8" X 10'-0" DRIVEN PULLBOX COPPER CLAD GROUND RODS 2"-3#3/0 SCALE: 1 = N.T.S VVMLLrfA%,n ( i T r.) ELECTRIC PLAN e EXISTING PANELBOARD AND METER CAN TO BE REMOVED NEW METER CAN `- NEW 200 A PANELBOARD 8 ,7"- NEW LED WALLPACK (TYP.) LTAM PS LOAD DESCRIPTIONAWG WIRE J a AMPS v BUS A B ! AMPS I a LOAD DESCRIPTION WIRE AWG VOLTAM PS A� B� A B 1200 AHU 12 1 20 1 2 1800 CU 12 12 1 1 20 1 20 3 5 4 1800 LIGHTING - OUTSIDE 6 900 LIGHTING - WAREHOUSE 12 1 20 7 8 900 LIGHTING - OFFICE 12 1 20 9 10 900 REC - OFFICE - ---- REC - SPECIAL EQUIPMENT N 12 1 20 11 12 1200 12 1 20 13 14 1200 REC - SPECIAL EQUIPMENT E 12 1 20 15 16 900 REC - WAREHOUSE GENERAL PURPOSE 12 1 20 17 18 900 REC - OUTSIDE GENERAL PURPOSE 12 1 20 19 20 21 22 23 24 _ 25 26 27 28 29 30 31 32 33 34 35 36 _ 37 38 39 40 41 42 6000 5700 TOTAL CONNECTED VA SUB -TOTAL VA TOTAL CONNECTED AMPS 6000 5700 TOTAL DEMAND VA TOTAL DEMAND AMPS 50 48 _ PANELBOARD RATINGS PANELBOARD FEATURES VOLTAGE 120/2081�, 3W 120/2403W ❑ BUS AMPS ❑ 1OOA ❑ 400A E 200A ❑ 600A ❑ 225A ❑ —A MAIN DEVICE ❑ MAIN LUGS ONLY ■ A CIRCUIT BREAKER ❑ A FUSED SWITCH ENCLOSURE ❑ FLUSH N SURFACE E NEMA 313 ❑ HINGED DOOR ❑ KEYED LATCH ❑ DOOR -IN -DOOR ❑ STAINLESS STEEL ❑ PAINTED STEEL ❑ NAMEPLATE BRANCH POLES ❑ 12 ❑ 32 ❑ 18 42 ❑ 24 ❑ BRANCH DEVICES CIRCUIT BREAKERS ❑ FUSES ❑ TO BE GFCI BREAKERS ❑ LOAD CENTER PERMITTED INTERRUPTING RATING (AIC SYM) ❑ 10,000A ❑ 30,000A ❑ 65,000A 0 14,000A ❑ 40,000A ❑ 100,000A ❑ 22,000A ❑ 50,OOOA ❑ ,000A ❑ SERIES RATING PERMITTED ❑ INTERRUPTING RATING (AIC SYM) NOTES NEUTRAL BUS ❑ 50% ❑ 200% 0 100% ❑ % BUS MATERIAL E COPPER ❑ ALUMINUM ■ GROUND BUS REQUIRED ❑ THROUGH FEED LUGS REQUIRED ❑ PANELS IN PARALLEL Z w „ � Uj Z � Z PRESTIGE POOL PLASTERING: WAREHOUSE RENOVATION 3810 CR-6 I S, FORT �;'s PIERCE, FL 34981 08/05/21 21-007 N ��, � � �'` �[�' %dy'�td'• ems. No. 7 77 1p STATE OF - 0 "91 0NA L`0 \\\�� E L As indicated - Author