Loading...
HomeMy WebLinkAboutProduct Data ( Comercial HVAC)Pallas Office HVAC Load Analysis for Pallas Office 2210 South 40th Street Fort Pierce, Florida PAN Fil r / an UrIVAC��T�t1R�YAI., SAC L oA s ga��/`' ••°• - � rye°•� ,mod ' N 982 a Cr m,0�•,� p Qa+q Prep fft,"*RY&fl '00��9� Eric J. Svoboda, PE Fort Pierce Engineering, Inc. 315 South 7th Street Fort Pierce, FL 34950 772-672-4636 Ad0:) .g7j.j Monday, April 6, 2020 Chvac Full Commercial HVAC Loads Calculation Program Elite Software Development, lnc Fort,*r6e Engmeerinq - Pallas Office '`PI �.. �r� , General Pro "ect Data Input Gerieral'Pto'ect"Information= • ;:: Project file name: Project title: Designed by: Project date: Weather reference city: Client name: Client address: Client city: Company name: Company representative: Company address: Company city: Company phone: Company fax: Barometric pressure: Altitude: Latitude: Mean daily temperature range: Starting & ending time for HVAC load calculations: Number of unique rooms in this project: 13uiltlma `;Qefault .Values o . 9 , Calculations performed: Lighting requirements: Equipment requirements: People sensible load multiplier: People latent load multiplier: Room sensible safety factor: Room latent safety factor: Room heating safety factor: People diversity factor: Lighting profile number: Equipment profile number: People profile number: Building default`ceiling. height: Building default wall' height:,: Pallas Office Heat Load.CH8 Pallas Office Eric J. Svoboda, PE Monday, July 07, 2008 FORT PIERCE, FLORIDA, USA Pallas Office 2210 South 40th Street Fort Pierce, Florida Fort Pierce Engineering, Inc. Eric J. Svoboda, PE 315 South 7th Street Fort Pierce, FL 34950 772-672-4636 772-672-4637 29.894 in.Hg,, 25 feet 27 Degrees 15 Degrees 7am - 10pm 4 Both heating and cooling loads 1.50 Watts per square foot 0.50 Watts per square foot 250 Btuh per person 200 Btuh per person 0 0,0 0 % 0 % 100 % 0 0 0 9.00 feet 10.00 feet ntei nal `O, `eratn :Load .Profiles` G = 10.0 y hr° hr hr I hr I hr hr .:, hr hr hr hr hr hr hr hr hr hr hr hr hr hr hr hr hr hr 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 1 21 22 23 24 1 C C C- C C C C C C C C C c C C C C C C C C C C C 2 C' C C C c ; C '. c C C C C C C C C C C C C C C C c C 3 .-C C C--" .0 C -C C C C C C C C C C C C C C C C C C C 4 'C C C C C ..0 c C C C C C C C C C C C C C C C C C 5 C C C C -`C• c- C C C C C C C C C c C c C C C C C C 6 C C C C.: ' C .' .G C C C C C C C C C C C C C C C C C C 7 C C C .. C C` C C C C C C C C C C C C C C C C C C C 8 C C c c ,.. c C C C C C C c C C C C C C C C C C C C 9 C C C C C C C C C C C C C C C C C C j C C C C C C 10 C C C C C C C C C C C C C C C C C C C C C C C C _Ar-1 I-IC1UIJ r-nylrleennyX4U rlofdclslLUuu i-uo rands vrnoe nea[ Loau.i.na IVlonuay, Hprn o, LULU, I l: I / HIVI Chvac -eFull Commercial HVAC Loads Calculation'Program" Fort PierceEngineeri' 4 " , ' [Forf AL Elite Software Development, Inc. Pallas Office L.. Pierce, .34950 , General Pro "ect Data Input cont'd buifdin "-Level Desiq n`Conditions . , Design Outdoor Outdoor Indoor Indoor Grains In/Outdoor Month Dry Bulb Wet Bulb Rel.Hum Dry Bulb Diff Correction August 95 80 50% 75 66.33 6 Winter 42 75 Waster Roofs Roof ASHRAE Roof Dark Susp. No. Roof# U-Fac Color Ceil 1 1 0.033 No No Roof #1 Description: Metal Roof, R-30 aster Walls Wall ASHRAE Wall Wall No Group U-Fac Color 1 C 0.095 D Wall #1 Description: Block wall, 8" sand & gravel, hollow core, siding exterior, interior finish, 1" extruded poly, R-5.0 I.VbisterQlass" Glass Summer Winter Glass Interior Interior No U-Factor U-Factor Shd.Coef. Shading Shd.Coef 1 0.810 0.830 1.000 1 0.550 Glass #1 Description: Default Glass Master Shading ..Devices Dist Dist Dist Dist Dist Dist Ht Dist Dist Ht Horiz Beyond Beyond Overh Right R-Fin Of Left L-Fin Of Shade Overh Right Left Above Fin Beyond Right Fin Beyond Left No Projects W Edge W Edge Wind Proj W Edge Fin Pro* W Edge Fin 1 6.00 7.00 3.00 2.00 0.00 0.00 0.00 0.00 0.00 0.00 Z:\Ft Pierce Engineering\20 Projects\20001-05 Pallas Office\Calculations\HVAC\Pallas Office Heat Load.CH8 Monday, April 6, 2020, 11:17 AM Chvac Full Commercial HVAC Loads Calculation Program Fort P�erceEngineennq Ejlrte Software Development, Inc PallasOffce Buildin Summary Loads Building peaks in August at 4pm. Bldg Load °,. Area Sen . %Tot Lat -Sen Net oss=, Loss . "GRaln ;Gain ' ° Gal 7ai Roof 640 697 5.79 0 851 ' 851 3.76 Wall 941 2,950 24.49 0 2,160 1 2,160 9:53 Glass 99 2,712 22.51 0 5,719 5,719 25.24 Floor Slab 104 2,128 17.66 0 0 0 0.00 Skin Loads 8,486 70.44 0 --.... ......--. ............ 8,731 _-........ _...... 8,731 38.54 Lighting 960 0 0.00 0 3,276 ! - 3,276 _ ........ 14.46 Equipment 320 0 0.00 0 11092 1,092 4.82 Pool Latent 0 0 0.00 0 0 0 0.00 People 6 0 0.00 1,200 1,500 2,700 11.92 Partition 0 0 0.00 0 0 0 0.00 Cool. Pret. 0 0 0.00 0 0 0 0.00 Heat. Pret. 0 0 0.00 0 0 0 0.00 Cool. Vent. 100 0 0.00 4,507 1 2,198 6,705 29.59 Heat. Vent. 100 3,561 29.56 0 0 1 0 0.00 Cool.lnfil. 0 0 0.00 0 0 j 0 0.00 Heat.lnfil. 0 0 0.00 0 0 0 0.00 Draw-Thru Fan 0 0 0.00 0 153 153 0.68 Blow-Thru Fan 0 0 0.00 0 0' 0 0.00 Reserve Cap. 0 0 0.00 0 0 0 0.00 Reheat Cap. 0 0 0.00 0 0 0 0.00 Supply Duct 0 0 0.00 0 0 0 0.00 Return Duct 0 0 0.00 0 0 0 0.00 Misc. Supply 0 0 0.00 0 0 0 0.00 Misc. Return 0 0 0.00 0 __ ..... ....... .. 0 0 0.00 Building Totals 12,047 100.00 5,707 . .._...__... 16,949 _._...... . __... ...... ... 22,656 _ ---- ........- 100.00 o Buil'ding' k"a �� Seri.%Tot r ° Lat ;,.� SenR Net �' %Net' Sumrnati :: ,-,:..Loss � 's Loss --Gain '� � _�.��� Gain.° �'Gain- Ventilation 3,561 29.56 4,507 2,198 6,705 29.59 Infiltration 0 0.00 0 0 0 0.00 Pretreated Air 0 0.00 0 0 0 0.00 Room Loads 8,486 70.44 1,200 14,598 15,798 69.73 Plenum Loads 0 0.00 0 0 1 0 0.00 Fan/Duct/Misc Loads 0 0.00 0 153 i 153 0.68 Building Totals 12,047 100.00 5,707 -- 16,949 1 22,656 _. 100.00 Che°ck,,Fi `ures ' Total Building Supply Air (based on a 21 ° TD): 639 CFM Total Building Vent. Air (15.65% of Supply): 100 CFM Total Conditioned Air Space: 640 Sq.ft Supply Air Per Unit Area: 0.9987 CFM/Sq.ft Area Per Cooling Capacity: 339.0 Sq.ft/Ton Cooling Capacity Per Area: 0.0030 Tons/Sq.ft Heating Capacity Per Area: 18.82 Btuh/Sq.ft Total Heating Required With Outside Air: 12,047 Btuh Total Cooling Required With Outside Air: 1.89 Tons i I I Z:\Ft Pierce Engineering\20 Projects\20001-05 Pallas Office\Calculations\HVAC\Pallas Office Heat Load.CH8 Mbnday, April 6, 2020, 11:17 AM s Chvac Full Commercial HVAC Loads Calculation Proqram Fort Pierce.Engineerinq Elite Software Development, Inc. Pallas Office` r FIL '34950 Page-5- Building Summary Loads Z Building peaks in August at 4pm. Bldg Load Area¢ Sen , , %aTot ` Lat ` Seii ` Net %Net D,escri" tions W uan -Loss x ::doss Gam` Gain,,, Gain,, -,!Gain Roof 640 697 5.79 0 851 851 3.76 Wall 941 2,950 24.49 0 2,160 2,160 9.53 Glass 99 2,712 22.51 0 5,719 5,719 25.24 Floor Slab 104 2,128 17.66 0 0 0 0.00 Skin Loads 8,486 70.44 0 8,731 8,731 38.54 Lighting 960 0 0.00 0 3,276 3,276 14.46 Equipment 320 0 0.00 0 1,092 1,092 4.82 Pool Latent 0 0 0.00 0 0 0 0.00 People 6 0 0.00 1,200 1,500 2,700 11.92 Partition 0 0 0.00 0 0 0 0.00 Cool. Pret. 0 0 0.00 0 0 0 0.00 Heat. Pret. 0 0 0.00 0 0 0 0.00 Cool. Vent. 100 0 0.00 4,507 2,198 6,705 29.59 Heat. Vent. 100 3,561 29.56 0 0 0 0.00 Cool.lnfil. 0 0 0.00 0 0 0 0.00 Heat.lnfil. 0 0 0.00 0 0 0 0.00 Draw-Thru Fan 0 0 0.00 0 153 153 0.68 Blow-Thru Fan 0 0 0.00 0 0 0 0.00 Reserve Cap. 0 0 0.00 0 0 0 0.00 Reheat Cap. 0 0 0.00 0 0 0 0.00 Supply Duct 0 0 0.00 0 0 0 0.00 Return Duct 0 0 0.00 0 0 0 0.00 Misc. Supply 0 0 0.00 0 0 0 0.00 Misc. Return 0 0 0.00 0 0 0 0.00 Building Totals 12,047 100.00 5,707 16,949 22,656 100.00 Buildlrig =Sen %TOt Lat Sen Net %Net Summa L'oss� '4 Loss Gain =# Gain ffi 'Galn - ' Gain Ventilation 3,561 29.56 4,507 2,198 6,705 29.59 Infiltration 0 0.00 0 0 0 0.00 Pretreated Air 0 0.00 0 0 0 0.00 Room Loads 8,486 70.44 1,200 14,598 15,798 69.73 Plenum Loads 0 0.00 0 0 0 0.00 Fan/Duct/Misc Loads 0 0.00 0 153 153 0.68 Building Totals 12,047 100.00 5,707 16,949 22,656 100.00 .Chei uck res.� Total Building Supply Air (based on a 21 ° TD): 639 CFM Total Building Vent. Air (15.65% of Supply): 100 CFM Total Conditioned Air Space: 640 Sq.ft Supply Air Per Unit Area: 0.9987 CFM/Sq.ft Area Per Cooling Capacity: 339.0 Sq.ft/Ton Cooling Capacity Per Area: 0.0030 Tons/Sq.ft Heating Capacity Per Area: 18.82 Btuh/Sq.ft Total Heating Required With Outside Air: 12,047 Btuh Total Cooling Required With Outside Air: 1.89 Tons Z:\Ft Pierce Engineering\20 Projects\20001-05 Pallas Office\Calculations\HVAC\Pallas Office Heat Load.CH8 Monday, April 6, 2020, 11:17 AM r Chvac -Full:"CommercialaHVAC Loads Calculation Program Fort Pierce Engineering = Elite Software°Development, Iric 'Pallas Office' Fort r 7 Air Handler #1- AHU 1- Total Load Summar Air Handler Description: AHU 1 Constant Volume - Proportion Supply Air Fan: Draw-Thru with program estimated horsepower of 0.06 HP Fan Input: 0% motor and fan efficiency with 0 in. water across the fan Sensible Heat Ratio: 0.92 --- This system occurs 1 time(s) in the building. --- Air System Peak Time: 4pm in August. Outdoor Conditions: Clg: 95° DB, 80° WB, 131.77 grains, Htg: 420 DB Indoor Conditions: Clg: 75° DB, 50% RH, Htg: 75° DB Summer: Ventilation controls outside air, ----- Winter: Ventilation controls outside air. Room Space sensible loss: 8,486 Btuh Infiltration sensible loss: 0 Btuh 0 CFM Outside Air sensible loss: 3,561 Btuh 100 CFM Supply Duct sensible loss: 0 Btuh Return Duct sensible loss: 0 Btuh Return Plenum sensible loss: 0 Btuh Total System sensible loss: 12,047 Btuh Heating Supply Air: 8,486 / (.999 X 1.08 X 20) = 393 CFM Winter Vent Outside Air (25.4% of supply) = 100 CFM Room space sensible gain: 14,598 Btuh Infiltration sensible gain: 0 Btuh Draw-thru fan sensible gain: 153 Btuh Supply duct sensible gain: 0 Btuh Reserve sensible gain: 0 Btuh Total sensible gain on supply side of coil: 14,751 Btuh Cooling Supply Air: 14,751 / (.999 X 1.1 X 21) = 639 CFM Summer Vent Outside Air (15.6% of supply) = 100 CFM Return duct sensible gain: 0 Btuh Return plenum sensible gain: 0 Btuh Outside air sensible gain: 2,198 Btuh 100 CFM Blow-thru fan sensible gain: 0 Btuh Total sensible gain on return side of coil: 2,198 Btuh Total sensible gain on air handling system: 16,949 Btuh Room space latent gain: 1,200 Btuh Infiltration latent gain: 0 Btuh Outside air latent gain: 4,507 Btuh Total latent gain on air handling system: 5,707 Btuh Total system sensible and latent gain: 22,656 Btuh Check. FIa ures ;: � Total Air Handler Supply Air (based on a 21 ° TD): 639 CFM Total Air Handler Vent. Air (15.65% of Supply): 100 CFM Total Conditioned Air Space: 640 Sq.ft Supply Air Per Unit Area: 0.9987 CFM/Sq.ft Area Per Cooling Capacity: 339.0 Sq.ft/Ton Cooling Capacity Per Area: 0.0030 Tons/Sq.ft Heating Capacity Per Area: 18.82 Btuh/Sq.ft Total Heating Required With Outside Air: 12,047 Btuh Total Cooling Required With Outside Air: 1.89 Tons Z:\Ft Pierce Engineering\20 Projects\20001-05 Pallas Office\Calculations\HVAC\Pallas Office Heat Load.CH8 Monday, April 6, 2020, 11:17 AM