HomeMy WebLinkAboutRevision Plans 2THE SCOPE OF THE WORK SHALL, INCLUDE THE FOLLOWING
SHEET f 1NIDX
• REMOVE EXISTING KITCHEN CABINETS, TOPS, APPLIANCES, ETC.
• SAVE d 64FELY STORE APPLIANCES
• REMOVE INTERIOR FRAME, NON LOAD BEARING WALLS AS INDICATED
• REMOVE EXISTING FIREPLACE (UP TO CEILING) d HEARTH
(ALL STRUCTURE ABOVE CEILING SHALL REMAIN INCLUDING CHIMNEY, CHIMNEY
CAP, ETC.i
• REMOVE EXISTING PLANTER BOXES AT FOYER
• REMOVE DOORS, WINDOWS E OVERHEAD GARAGE DOORS WHERE INDICATED
• REMOVE EXISTING FANS E LIGHT FIXTURES WHERE INDICATED
• SHORE OF 4 REMOVE EXISTING COLUMN ea CENTER OF COVERED LANAI AS INDICATED
• REMOVE EXISTING SCREEN ENCLOSURE AT COVERED LANAI d GRILLING PORCH
• INSTALL NEW IMPACT RESISTANT DOORS, WINDOWS E OVERHEAD GARAGE DOORS
WHERE INDICATED
• RELOCATE EXISTING ATTIC ACCESS # RETURN AIR GRILL AS NOTED
■ INSTALL NEW COLUMNS 8 HALF WALL W/ GRANITE TOP BETWEEN DINING d LIVING ROOM
• INSTALL NEW KITCHEN CABINETS, COUNTERTOPS, APPLIANCES, PLUMBING FIXTURES,
ETC,
■ INSTALL NEW MICROLAM BEAM BETWEEN REMAINING COLUMNS AT COVERED LANAI
(FOLLOWING REMOVAL OF CENTER COLUMN)
■ CONSTRUCT NEW 2" X 5" FRAME WALL W/ CASED 4 TRIMMED OPENING AT CORNER OF
EXISTING NOOK AS INDICATED
# I DEMOLITION PLAN
# 2 FLOOR PLAN
03 EXTERIOR ELEVATIONS 4 DETAILS
# 4 ELECTRICAL 4 HVAC PLAN
NOTE"
KELLY 8 KELLY ARCHITECTS IS NOT RESPONSIBLE FOR THE DESIGN OF A
NECESSARY REPAIR, REPLACEMENT OR RENOVATION TO ANY UNFORESEEN,
CONCEALED STRUCTURAL CONDITION EXPOSED DURING THE DEMOLITION
PHASE OF A REMODELING PROJECT
ANY 4 ALL EXPENSES RELATIVE TO SUCH A 61TUATION SHALL BE THE
RESPONSIBILITY OF THE OWNER
• CONSTRUCT NEW, LOW, BUILT IN BOOKCASES BETWEEN FOYER $ LIVING ROOM r — — — —
• TRIM OUT COLUMNS AT BOOKCASES
• DRYWALL, TRIM E PAINT INTERIOR AS REQUIRED
I
I I
I
1
CONSTRUCTION OF TH16 ADDITION IS A LEVEL 2 vALTERATiON
I
1
ACCORDING TO THE FLORIDA BUILDING CODE 2014, THE WORK
1
SHALL BE PERFORMED IN STRICT ACCORDANCE WITH THE
PROVISIONS OF THE FOLLOWING- I
SECTION 601 - STRUCTURAL
!
!
SECTION 608 - ELECTRICAL
I
SECTION 609 - MECHANICAL
!
SECTION 6 10 -PLUMBING
BEDROOM #2
�
I
I
I
r_
1
e 111
�
I
REMOVE EXISTING
\
\
/ I 11
WINDOWS
it SCRN
� II
SCRNI
I
-- - - - --
---
IDOOR
DOO 1
--I--- -
- -- - ----- - --
--- -- -- - ------- - - - - ----- - - - - ------- - - - - --
REMOVE EXISTING SCREEN
!
III
ENCLOSURE 4 SCREEN DOORS
GRILLING PORCH GRILL
1
COLUMN TO BE REMOVED
'3'-0" CEILING HT,
i
SINK
- _ _
NOTE; L.1
a .0
r
REMOVE EXISTING
WINDOWS t ENLARGE
m
SHORING WILL NOT BE REQUIRED IF NEW MICROLAM
REMOVE EXISTING DOOR
OPENING FOR NEW ` `
BEAM IS INSTALLED d FULLY SECURED PRIOR TO
i ' r (SHALL BE REPLACED W/
i
FRENCH DOOR PAIR
REMOVAL OF CENTER COLUMN
LL REIJOVEN NEW, IMPACT RESISTANT UNIT)
FAN
-- - - -- REMOVE EXISTING WALL
I
I
�
! I REMOVE EXISTING
I I WINDOWS
NEW IMPACT RESISTANT UNITS
I I SHALL BE INSTALLED)
C ® E E LANAI
1
`
�I
Cco,
REMOVE EXISTING
REMOVE EXISTING LLIIGHT EMOVE FIXTURE
- - - - - - - - " - - - - -
REMOVE ALL EXISTING FIXTURES, I I WALL LIGHT REMOVE EXISTING S.GD. UNIT WALL LIGHT
ETC, EXISTNGTOWNERSSBATHTING OWNER S SUITE E l } - - - - - --NCLUDING ALUMINUM THRESHOLD - �� ;� J ` j NOOK TTTTTT
J REMOVE EXISTING FLOORING - 1 r U I I
WILL BE REPLACED W/ NEW � I� REMOVE I ! I I
POCKET UNIT/ IMPACT RESISTANT) I CEILING FAN
AJ i
i
ALL FIREPLACE STRUCTURE ABOVE CEILING Ir 11
H I I p�
I (INCLUDING CHIMNEY, CHIMNEY GAP, ETC.) i ! �2�
SHALL REMAIN AS IS WALL TO BE
U< REMOVED I I
KITCHEN
FLR. RECEPT. (((���
I-•� '4�1-�'. I
- T\ 1�I L/_� �112-8�' CATHEDRAL GEILrN\G P��I kiLC �_y1- --_I inCC II [DINING II -II RE�Mt�OVE EXISTINGCA51�NE�TSIiILIVING RAPPLIANCES,
LIGHTING, SAVE t
WOOD FLOOR ACCESS SAFELY STORE APPLIANCESy)3 rLlI
I! II TO BE
REMOVE EXISTING CEILING
LIGHT FIXTURES E CEILING FANS ' RELOCATED r - - 1 11 � 1' 1
REMOVE ALL FLOORING, RODS d SHELVING R/A FROM EXISTING WALK IN CLOSET i GRID 11PANTSII(
I HEARTHG4 FIREPLACE
% i / CAB'T r
/ TO BE J II REF.- -41- - TO BE REMOVED (UP TO REL &TED q 11
` CEILING/ ALL STRUCTURE V _ _ v Q _ _ �I _ �� �j
i FLR. RE�EPT. �
I
ABOVE SHALL REMAN)
30" HT, PLANTER BOX
\
30" HT. PLANTER BOX
TO BE REMOVED
` TO BE REMOVED y�l
- - - - - - - - -
- - - - -. -
_ _ _ _ _ _ _ _ _ _ _ _ _... - -
REMOVE EXISTING
- - - - - - - - _ - _
I REMOVE EXISTING '-
I SOFFIT <LIGHTS ABOVE
FO I ER i SOFFIT a LIGHTS ABOVE
jr
CATHEDRAL
L - - - - - - - - - - - - - - - I
CEILING
-
-U a r------�
I
REMOVE EXISTING
LIGHT IXTURE
--- - - - - - -I
___ i__ I-- ----------
I !
-----n-
REMOVE ExIS NG ENTRY DOORS,
FIXED GLASS SIDELITES, d TRANSOM
WINDOW ABOVb
ENTRY
CATN ORAL
I
CEII G
I I
! I
I
I
.— — — —L—
I
I
I
i
REMOVE RECESSED LIGHTS �y
PRYER ASHE F
LAUNDRY
- - -FICILO,
-
-
- - - - - --
REM IVE CEILING
LIGHTTp THIS HALLWAY
I
I I i
� I
w REMOVE EXISTING
WINDgWS/ ENLARGE OPENING FOR
O NEW WINDOW UNIT (90" WIDE X 38" HIGH)
� I I
cl
z FILL IN LOWER PORTION OF
_ OPEI4 NG/ POUR SILL FOR
w NEW _ NDOW
z- - - - - - - - - - - - - - - - - -i
U I
Q I
I
I
k
I
i
I
I
I
I
I
I
I
I
i
i
I
I
I
I
I
I
I
I
I
I
I
1
°O I
REMOVE EXISTII
GARAGE I I DOOR/ TOBER
W/ NEW, IIi11PACT
REMOVE EXISTING OVERHEAD GARAGE DOORS/ WILL BE REPLACED UNIT
W/ NEW IMPACT RESISTANT t INSULATED UNITS - SAME SIZE
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REOUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARYIN ORDER TO
COMPLY WITH ALL APPLICABLd COOHIt,
ALL MANUFACTURES LABLES SHOWING
U FACTORS AND SHGC CpMpUANCE
WITH FBC ENERGY CODE MUST
REMAIN ON ALL DOORS AND WINDOWS
UNTIL INSPECTIONS ARE APPROVED
CONCEALED FASTENERS OR ATTACHMENTS
ARE THE RESPONSIBILITY OF THE
CONTRACTOR OF RECORD
](l9 76
ST. Lt:C!'03
r Cf?L�1TY'?TTI ^ nT,,TcTr)v
REVIE\�LDFO[�1f�j vCE
REVIENI'ED BYC'ILE�
DATE
PLANS AND RNUT NTLIST RE KEPT ON JOB
OR NO INS TION WILL BE MADE.
WALL LEGEND
EXISTING 8" CMU WALL TO REMAIN
EXISTING 2" X 6" FRAME WALL TO REMAIN
EXISTING 2" X 4" FRAME WALL TO REMAIN
EXISTING 2" X 6" FRAME WALL TO BE REMOVED
III== == EXISTING 2" X 4" FRAME WALL TO BE REMOVED
/4 it e 1'-OII
ED
ANT vJ"
He Copy
25 0 T
i JAN 18
/// 0lillal0���
\ y
i
I
i
I
I
I
I
FIXED IMI?ACT
RESISTANT GLASS
PROVIDES" X 8" FORMED t x
POURED CONCRETE COLUMN
W/ 105 BAR DRILLED t EPDXIED I v
INTO FOOTING tAPTB BEAM- - - - -
ABOVE (30" OV�RLON-
STEEL/ TYPICAL� AT EACH
SIDE OF NEW WINDOWS
I
I —
EXISTING WINDOWS TO
BE REPLACED l / NEW,
IMPACT RE5IST4NT
UNITS
(VESSEL
TUB /
FIXED IMPACT
RESISTANT GLASS
48" X 24"
EXISTI G ION I
EXI C SN LA�v DOWNER 5
/ \\A! H..
-- - - - - -
\
\
x sO THR'D.
REPLACE EXISTING F6.
w WINDOW W/ IMPACT ei
z RATED FRENCH DOORS
LINEN PROVIDE 8" X 8" FORMED t J
CAB POURED CONCRETE COLUMN
W/ 105 BAR DRILLED t EPDXIED
INTO FOOTING t INTO BEAM
ABOVE (30" OVERLAP ON
STEELY TYPICAL AT EACH
SIDE OF NEW DOORS
LAV
OWNER'S SUITE
I Q
I
I'
1 3'O"X "
5181,
co
NEW 2" X 4"tAME fl xWALLS 9 TOT ROOM "� O
WC
I
I
RtS 2'6"X6w, R48 -
I
WALK IN CLOSET
_SHOE
I
Rt8 I�
I
1 RtS al
-- — — —— Agag
I
t �
I ;
9' - O" AFF
OPEN TO
FOYER
BOOK
SHELVES
lo" X IO" COLUMNS
TRIMMED OUT t
PAINTED
OPEN TO
LIVING ROOM
36" HI WALL W/ WOOD TRIM
GRANITE TOP
WOOD EASE
DINING ROOM ELEVATION
1/411 = 11011
NEW SCREEN ENCLOSURE/ INSTALLER SHALL PROVIDE ENGINEERED DRAWINGS
I
Pd0
ALL RK RELATIVE TO
POO INSTALLATION IS COMPLETED
UNDE SEPARATE PERMIT
I
I
I
I
I
I
I I
I
I
I
I I
I
5 A 1
I
I
I
BENCH EDGE
I
I
I
i
I
I
I
--------------------------.._- --- - - - - - --
i
STRAP NEW MICROLAM BEAM
TO BOTTOM CORD OF EXISTING
TWO (2) PCS. 13/4" 16" MICROLAM BEAM TWO PLY GIRDER W/ 1/2" X 4 1/2" LAG GRILL
NAILED TOGETHE (COMPOSITE BEAM) BOLTS as 24„ O.C. STAGGERED
- - -_- - - - - _ _ _ _ _ _ _ _ STRAP NEW MICROLAM BEAM TO
- �_- - _ _ COLUMNS AT EACH END W/TWO (2) GfRILL ING PORCH SINK
- , � - - _G - - - LSTAIS FLAT STRAPS W/ 14 - I0d 9 each ® 9'-O" CEILING HT.
EXISTING 6 X 6 POST EXISTING DOUBLE PLY GIRDER TRUSS I
-IN EXISTING COLUM� _ REPLACE EXISTING
NOTE FRENCH DOOR W/
SHORING IS NOT REQUIRED IF NEW MICROLAM BEAM IS INSTALLED I EXISTING 6" X 6" POST IN NEW IMPACT RATED UNIT
t FULLY SECURED PRIOR TO REMOVAL OF CENTER COLUMN EXISTING COLUMN
I O'-0" CEILING HT.
NEW 8" W X 3P CONCRETE CURB W/ 2 $5
BARS CONTI UOUS FOR POCKET S G1)
REPLACE EXISTING S.GD.W/
IMPACT RA D POCKET 64D-
---------I60 16----------
0 o I O 0 o c
LIVING OOM
CATHEDRAL CEILI G
WOOD FLOOR 10" X l0"
TRIMMEC
O O O O O c
OP EXISTING SL W/ 5" (. / -) EXISTING
r =1 = ,
I ONCRETE TO MA CH FLOOR TO BE REMOVED/
I FLAT SCREEN
11 Tv (BY OWNER) EVEL OF FOYER, fTGHEN, ETC, CHIMNEY ABOVE
II ROOF SHALL REMAIN
II DOWEL NEWLY TO PEA SLAB TO
II EXISTING W/ 24" L NG 05 BARS 9
48" O.C/ DOWEL 4IEPDXY INTO
0
LEVEL IN NEXISTING SLAB 12" 4 EXTEND 12"
r -n O O O / \ o O C
PROVIDE 4" CON TA�'\CONS DOWELED t loll X loll
EPDXIED jN/T0 EX TING SLAB 2" t EXTENDING TRIMM C
NTO NEW TOPPING 2" 9 48"�O.C, EACH WAY
\
10" X loll WOOD/ \I 10" WOOD
TRIMMED COLUMN \ TRIMMED COLUMN;
�r
I!j6LALL NEW 1 U11 t-IN _ 0 ' I INSTALL NEI
BIDOiCCASE t SWIYES LJ W 11 HOG�KCASE
J 1
SOFFIT TO BE REMOVED SOFFIT TO BE
CATHEDRAL
c
ANCHOR LEGEND
MARK
MAXIMUM
ALLOWED
UPLIFT
SIMPSON
MODEL
NUMBER
QUANTITY, SIZE t TYPE OF
ANCHORAGE REQUIRED
A
2300
ABU66
5/8" ANCHOR BOLT / 12 -16d /
2 - 1/2" MACHINE BOLTS
B
4040
CCbb
4 MACHINE BOLTS TO BEAM
2 MACHINE BOLTS TO POST
y
0 v
N- -
Fa
\
RE�Og4tr)
0
ATTTT19 \ i
ACajF9,E S I
WOOD
CASED
4
2" X 8" \OPENING
fey`
COFFEE
p
FRAME WALL
+off\
ALCOVE
NOOK
9'-0" FLAT CEILING
_
9'-0" FLAT CEILING
_
II
VERIFY all CONCRETE
11 11 EXISTING AHU FILLED CELL W/ 105 DOWEL
I 1 x I"'
II
IN
_ _I_,II IN ATTIC
THIS SIDE OF WINDOW (OTWERWIS
E,
-
PROVIDE FORMED t POURED
-
COLUMN AS ON WEST SIDE)
/)
*
ASH
KNEE
r------
ECYC,
I ISLAND (6' X I)')SPACE
1
BELOW
136 HT. FARM
WINE SIN 11
e
CH! I5P DER
"
DINING
I n I
9'-0" FLAT CEILING
D/W
-
_
VEG. SINK W/
J
HIGH WALL GRANITE
I
CADISPOSER
CA P (WOOD TRIM
I M ITCNEN
- -
'
-I IK
I OVEN 11 D . 19'-0" FLAT CEILING
1
.1'4"
i I 4'9� - - 5'0"
?'rh" ,
LACE EXIST
FIRE N AB E 1
W/ IMP T ATEO UNI 1
(MATCH STING SIZE
_ 7 THR D
i 2 •3'O'X6'8" I
1 12" X 80" 12 X 80" 1
REPLACEIEXISTING
FRONT D OR t SIDELITES
W/ IMPAC RATED UNITS `
MATCH E ISTING SIZES) I
NTR1f
I I I
n O' -O' FFL I CATHEDRAL CEILING 1
DINING ROOM I
I I I
GENERAL NOTES-
* CONTRACTORS TO VERIFY ALL INTERIOR BEARING WALL FTG, W/ TRUSS MANUF,
* CONTRACTOR TO VERIFY LOCATION OF ALL UTILITIES AVAILABLE AT SITE
BEFORE PROCEEDING W/ CONSTRUCTION
* DUROCK SHALL BE USED IN ALL DAMP LOCATIONS
* PROVIDE PLUMBING ACCESS PANELS TO ALL SLIP JOINT CONNECTIONS
* WINDOWS SHALL BE HEAVY DUTY ALUMINUM W/ IMPACT RESISTANT GLASS,
FRAME COLOR TO MATCH EXISTING $ SCREENS
* SIXES INDICATED AT ALL DOOR E WINDOW OPENINGS ARE NOMINAL AND MUST BE
VERIFIED W/ MANUFACTURER FOR ACTUAL SIZE AND ROUGH OPENING
* TEMPERED GLASS TO BE USED AT ALL HAZARDOUS AREAS
* EXTERIOR DOORS E WINDOWS SHALL BE CERTIFIED FOR RESISTANCE TO LOCAL
WIND PRESSURE AS REQUIRED BY F.B.C. 2014 -110 M,PA. WIND LOAD
* ALL LUMBER IN CONTACT W/ CONCRETE OR MASONRY SHALL BE PRESSURE TREATED
* ALL STRUCTURAL FRAMING TO BE HEM FIR 02, SPF 01, SOUTHERN PINE 02 OR
APPROVED ALTERNATE W/ Fb=1000 P.S.I. MIN. NON - STRUCTURAL FRAMING MAY
BE SELECTED SPECIES - "STUD" GRADE
* ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH F,B.C, 2014
* ALL WORK RELATIVE TO THE GAS INSTALLATION SHALL BE PERFORMED UNDER
A SEPARATE PERMIT
------------
SCRN I
DOOR '
1 m. rvvwww��gq
�ww>�
EXISTING POOL EQUIPMENT SHALL BE
t SPA EQUIPMENT SCREENED W/ LANDSCAPING
0
1 ,
I
BEDROOM #2
I
i
I
�
I
I
I
I
EXISTING 3b TC
NI
A/C COMPRE5
OR I
- --------------
EXISTING EQUIF
MENT
SCREEN WALL
I —BASE tIWALL CABINETS _O
REMOJE EXISTING WINDOW t
REPLA E W/ NEW UNIT/ NEW SIZE
(IMPAC RESISTANT)
HORIZCINTAL SLIDER
_ IMPACT RESISTANT
I
o PROVE 8" X e" FORMED t
POURCONCRETE COLUMN
W/ 1.5AR DRILLED t EPDXIED
INTO Ft T_Il a_ IpTo 15EAM
ABOVE (30" OVERLAP ON -1°� _ I
STEEL)/ TYPICAL AT WEST I
F SIDE OF NEW WINDOW 1
— BASE t WALL CABINETS I
GA6 RANGE
rrr
- .- -
ABOVE
1
i � IIq nit_;I
NMI
I
ItF,, li�_,,it 41 I!�,
DRYER ASHER
LAUNDRY
- - -FFLO,
--------
REPLACE EXISTING OVERHEAD
GARAGE DOORS W/ IMPACT RESISTANT to
INSULATED UNITS MATCH EXISTING SIZES)L-1REPLACE EXISTING DOOR x
W1 IMPACT RATED UNIT
6' X I' CART DOOR) DOOR < G� (MATCH EXISTING SIZE)
WALL LEGEND
EXISTING 2" X 4" FRAME WALL
EXISTING 2" X 6" FRAME WALL
EXISTING 8" C.11AL WALL
PROPOSED 2" X 4" FRAME WALL
` PROPOSED 2" X 6" FRAME WALL
PROPOSED 8" FRAME WALL
I
� I
I
I
I
I
I
I
I
I
I
I 1
I I
{
I
1
I
I
I
I
i
i
I
I
EXISTING WELL PUMP
_ I
i FLOC)R FLANml
EXISTING 1.5 TON 1/411 a 11 O 11
x
a
Q
IY
LL
.J
t-=
Z
W
E
(L
O
J
w
w
n
w
0
L1
IY
Qf
O
In
LY
a
889181808
25 OCT 11
11 NOV 11
J N I8
16I19
r
2
OF FOUR
A/C COMPRESSOR °; � p '
PAI
I ' a� a �:,✓ '� 'y' � r - . L
I
File Copy
4 _D 4 4 HEAD
4 0 0
04 oD
5/8" LITE TEXTURE D CONCRETE TIE BEAM W/ 4 - #5
STUCCO D \ 0 D BARS OR PRE - CAST LINTEL
I
SEALANT P,T, 2" X WOOD BUCK ANCHOR TO
CONCRETE W/ 1/4" TAP CONS W/ I" DIA,
WASHER W/ 1 1/4" CONC. EMBED
—8" OZ. FOR T 4 LARGER OPENING
IMPACT RESISTANT 12" OZ. FOR SMALLER OPENING
VINYL WINDOW START 3" FROM EACH CORNER
(TYPICAL ON ALL 4 SIDES OF WINDOW)
SEALANT
4 WOOD SILL (VERIFY 4 MATCH EXISTING)
WASH
4 ° POURED CONCRETE SILL W/
O 1#5BAR
o
D
Ei�n SILL
UJINE)OUJ DETAIL
1 1/211 _ II—OII
NEW FIXED \\N
GLASS TRANSOM
EXISTING OPENING)
_NEW ENTRY DOORS 4 SIDELITE4�
EXISTING STRUCTURE
MEW DOORS 4 SIDELITES IN EXISTING OPENINGS)
411 a Is®II
/ EXISTING
3" V,T.R.
ALL NEW PLUMBING FIXTURES
na OWNER'S BATH/ REVENT ALL
-ti TO EXISTING V.TR.
r I 11
\2„
EXISTING
2" 1 4" C.O. 2" V.TJR,
LAV TUB
3„
I SHOWER
WC LAv DBL SINK
y T ELIMINATED)
2 � 2�� I r l 1 `
4" EXISTING
PLUMBING LINE
1 r�
OW I 1
(ELIMINATED) I / RE -VENT ALL NEW
/ PLUMBING FIXTURES
120 TO EXISTING Y.T.R.
I
NEW VEG 2" 1 2"
SINK W/
DISPOSE 1 NEW
I DW
y/ FARM
4 EXISTING SINK W/
PLUMBING LINE DISPOSER
N.T,S,
8" X 16" CONCRETE
BLOCK
5/8" STUCCO
FILLED CONCRETE BLOCK CELL
(OR FORMED 4 POURED) W/ 105
BAR EACH JAMB
CONCRETE SILL
SEALANT
BRICK MLD.
1 3/4" IMPACT
RESISTANT FRENCH DOOR
1 1/2" = I I-p ll
1/2" DRYWALL ON I" X 2" P.T. FURRING
RIGID INSULATION
0'_
p .
v, o
4 to`ra
0 op.
2" X 4" PRESSURE TREATED
E DOOR CASING (MATCH EXISTING)
E FIR JAMB
ALUM. THRESHOLD
P.T. 2" X WOOD BUCK ANCHOR TO
CONCRETE 4 CONCRETE BLOCK W/ HILTI
PIN DS Xn DIA.1 1/4" PENETRATION
'a 16" OZ. MIN, OR 1/4" TAP CON
SCREWS al 12" O/C
FIREPLACE 4 ALL RELATED -
STRUCTURE UP TO INTERIOR CEILING
SHALL BE REMOVED/ CHIMNEY,
CHIMNEY CAP 4 ALL STRUCTURE
ABOVE CEILING SHALL REMAIN AS I;
IMPACT RESISTANT INSULATED
OVERHEAD GARAGE DOOR
GARAGE DOOR A_TTACNMENT'
2" X 8" P,T, WOOD BUCK TO CONCRETE
1' - O" HIGH DOOR - 4 - 3/8" X Y SLEEVE ANCHOR,
ITT RAMSET /RED HEAD # HN-3830 SPACED AS REQUIRED
BY MANUFACTURER AT EACH SIDE
TRACK BRACKETS TO P,T, BUCK
1' - O" HIGH DOOR = 5 - 3/8" X 1 1/8" LAG, SCREWS
WITH WASHER HEADS, SPACED AS REQUIRED
BY MANUFACTURER AT EACH SIDE
1 1/2 11 m I,—OII
i
NEW IMPACT
RESISTANT HORIZ.
SLIDER
(Z
Q
i
mW
NEW IMPACT WINDOW
EXISTING STRUCTURE
1/411 I10'I
IJINE) LOAD INFO MATION
CODE EDITIONS: 2014 FLORIDA BUILDING CODE
CHAPTER 6 OF ASCE 1 - 10
BUILDING DESIGN: ENCLOSED
ULTIMATE DESIGN WIND SPEED-. 110 MPH
NOMINAL DESIGN WIND SPEED: 132 MPH
RISK CATEGORY II
WIND IMPORTANCE/ USE FACTOR: L O
INTERNAL PRESSURE COEFFICIENT:
EXPOSURE CATEGORY: B
WALLS (ENCLOSED)' 33 P15,F,
IMPACT PROTECTION: IMPACT RESISTANT DOORS 4 WINDOWS
COMPONENTS 4 CLADDING: ZONE 4 ZONE 5
10 SQ. FT, _ + 40.0/ -41b PS,F, 10 SQ, FT, _ + 44,0/ -58.8 PS,F,
20 SQ, FT, _ + 42,0/ - 45,6 P.6,F, 20 SQ, FT, _ + 42,0/ - 54,9 P S,F,
50 SQ. FT, _ + 393/ - 43.1 PS,F, 50 SQ, FT, _ + 393/ - 4916 P S,F,
100 50. FT, _ + 31A/ - 41,0 P,S,F, 100 SQ. FT, _ + 31,4/ - 45,6 P S,F,
ALL DOORS 4 WINDOWS TO BE INSTALLED AS PER PRODUCT APPROVAL
TIE BEAM "\
NEW —� a
WOOD
CASING I�I�
III
1111l11
REMOVE 1 111111
EXISTING I II III
S.G.D., jIIIIII
BUCKS,
TRACK, ETGII I it II
1111
111111
1 III III
IIIIII
111111
IIIIII
Ill1 1
11
11
III I
I IIIIII
IIIIII
111111
111111
1 IIIIII
I II I11
i, l
TRU56
2" X 4" BLOCKING al 24" O,C.
2" X 8" P.T. TOP PLATE W12 -
8" GALV. DECK SCREWS 151
16" O.C. INTO LEDGER 4 TRUSS
P.T.2" X B" 6 16" OZ,
1/2" COX PLYWOOD, 30# FELT,
WIRE LATH 4 STUCCO
2" X 4" P.T. NAILERS 6 32" O,C,
W/ 3 - 3" TAP CONS TO CONC.
4 4 - GAILY. IOd NAILS TO 2" X 8"
DBL, 2" X 8" P.T. BOTTOM
PLATE W/ STAGGERED JOINTS
NEW HEAVY DUTY SLIDING
GLASS POCKET DOOR W/
IMPACT RESISTANT GLASS
NEWLY TOPPED LIVING ROOM
SLAB (5" CONC./-)
PROVIDE 8" W X 3" CONCRETE
CURB W12 05 BARS CONTINUOUS
FOR NEW POCKET SG.D. TRACK
EXISTING FOOTING 4 SLAB
NAILING SCHEDULE
ITEM
NAIL
SIZE
EDGE
SPACING
FIELD
SPACING
NOTES
5/8" COX ROOF SHEATHING
8 d
6" OZ,
6" O.C.
3" O.C. EDGE 4 3" O.C, FIELD WITHIN 4' OF ROOF EDGE
5/8" COX ROOF SHEATHING
8 d
4" OZ.
6" O.C.
8'- 0" FROM GABLE END ROOF EDGE
1/2" COX WALL SHEATHING
8 d
6" OZ.
6" O.C.
3/4" T 4 G FLOOR SHEATHING
10 d
6" O.C.
6" O.G.
GLUE ALL PLYWOOD (PL400 OR EQUAL)
STUD TO 2 X 12 HEADER
16 d
3 PER HEADER PLY
BASE SHEET NAILING
6" O.C.
IS" 4 II"
HARDI PLANK LAP SIDING
8d
GLUE/ BLIND NAIL fit TOP 16" O,C./ CAULK BOTTOM EDGE
ROOF SHEATHING USE Sd RING SHANK NAIL
ALL NAILS TO BE GALVANIZED
1/211 a 1'-011
\�5 VERIFY EXISTING
ROOF PITCH
EXISTING TWO PLY GIRDER —�
TO REMAIN \�\
IF SPLICE EXISTS d AREA Of
CENTER COLUMN BEING REMOVED
PROVIDE 1/2" PLYWD, GUSSET EA. SIDE
EXISTING T 4 G CEILING
NOTE:
FULLY SHORE EXISTING
STRUCTURE PRIOR TO REMOVAL
OF CENTER COLUMN 9 COVERED
LANAI
SEE SHORING DETAIL ON
SHEET #1
ALL SHORING SHALL REMAIN IN
PLACE UNTIL NEW BEAM IS FULLY
INSTALLED 4 STRAPPED
EXISTING
4" CONCRETE SLAB W/ 6 X 6
10/10 W.W.M. ON WELL - COMPACTED,
POISONED SOIL 4 CONT. 6 MIL
VAPOR BARRIER --�
DBL. 2" X 4" TOP
PLATE
2" X 4" STUDS
a 16" O/C
8" C.B.S. FILLED
CELL W/ 1- 05 BAR
PROVIDE 010 X 5" TAPCON
SCREWS,a 16" O/C INTO
BLOCK WALL
2" X 4" SILL PLATE
EXISTING CONCRETE
TILE ROOFING
+ 10'- 0"
r BEARING HT,
EXISTING DRIP, FASCIA 4 SOFFIT
TWO (2) PCS,13/4" X 16"
MICROLAM BEAM
NAIL NEW MICROLAM BEAM TO
BOTTOM CORD OF EXISTING
TWO PLY GIRDER TRUSS W1 1/2" X 4 1/2"
LAG BOLTS 9 24" O.G. STAGGERED
STRAP NEW MICROLAM TO COLUMNS
AT EACH END W/ TWO (2) LSTAIS FLAT
STRAPS W114 -10d 6 EACH
NOTE-,
SHORING IS NOT REQUIRED IF NEW
MICROLAM BEAM 16 INSTALLED 4
FULLY SECURED PRIOR TO REMOVAL
OF CENTER COLUMN
COLUMN BEYOND
POOL DECK W/
DECK O DRAIN CHANNEL
DOWEL NEW SLAB TO
EXISTING W/ 1/4" X 3" TAPCONS
AT 12" O.C, STAGGERED W/ I" MIN,
IMBEDMENT INTO EXISTING SLAB
w
w
N
O' - OR FPL, 6 PORCH 7
.q
}
0
Z
LIJ
W_
L11
O
0
4" MIN, 2500 P ,I. MIN, p'
FIBERMESH CONCRETE
1 d° 4 4 e 4 4 e
EXISTING SLAB NEW SLAB
6 MIL, VAPOR BARRIER ON 2500 P,S,I,
COMPACTED 4 TERMITE TREATED SOIL
DOWEL NEW SLAB TO
EXISTING W/ 8" LONG *
BAR DOWELED 4 EPDXIED
INTO EACH aQ 12" O,G,
REPAIRS 24" WIDE OR LESS
4" MIN. 2500 P,S,I, MIN,
FIBERMESH CONCRETE
C-
.
r- EXISTING SLAB NEW SLAB
6 MIL, VAPOR BARRIER ON 2500 P.S,I,
COMPACTED 4 TERMITE TREATED SOIL
25 OCT 11
11 NOV 11
1 JAN i 8
161113
1 APR 11
OF FOUR
A# ISM
File Copy
TO F,P. 4 L. SERVICE
LOCATION/ COORDINATE
WITH UTILITY
3 # 500KCMIL, IN 3" CONE), —
UFER GROUNDING AS REQ'D,
BY N,E C,
N.T.S.
# 500KCMIL, IN 3" COND,
I WIREWAY I
H 200
2 200
# 1/0 GND.
5�RVIGE VOLTAGE
120/240V,l PHASE 3W
EXIST.
50 200 A
2 50 PANEL
"A"
#3/0,1#6G,
5/8" X 10' GROUND ROD DOWELED
TO FOOTING STEEL
(ALL
COMPONENTS
ARE
EXISTING)
EXIST,
50 A
PANEL
IIB It
-- - - - - - - - - - - - - - - - - - - - - - - -' - -
VP TO POOL
LIGHTS
I
I I
VP I
I a
I
EXW 3 1 NIEW Aj116
FAN �CG� SI
1
I % LITE IN SPECIAL
40/
ATTIC FIXTURE
GFI
ELECTRICAL IS EXISTING _ _ _ _ _ _`_ -A-II
t SHALL REMAIN AS IS _ AHU IN G II LI I
-
-------------- - -- - -- -
3 3 ATTIC N _ I III MINI
40/ 1 1 31 S
I Ly-i sri
I I
40/ FIMINI
I
FLOOR I CANS
1 RECEPTACLE
I F II I
I I
I VERIFY MOUNTING MGT. OF _ _ _ _ _ _ SPECIAL
RECEPTACLE 4 JACK FOR TV I FIXTURE
I II I
I
I \
- - - / � FLO)
I
I I RECE ACLE i
El E71
i
--------------------
L- - - - - - - - - - - - - - - -I
I ----
I I I
Q PROVIDE ARC -FAULT INTERRUPTOR PROTECTION 4 I 1
TAMPER -RESISTANT RECEPTACLES AT ALL NEW AREAS I I
■ PROVIDE ARC -FAULT INTERRUPTOR PROTECTION 70 ANY NEW - - - - - - - - - - - - - - - - - - � r _ _ _ _ _ _ _ _ _ _ ._ _ -- - - -
I
BEDROOM CEILING FANS ! SMOKE DETECTORS
I I I
■ PROVIDE VARIABLE SPEED SWITCHES FOR NEW CEILING FANS
I I I I
■ ALL ELECTRICAL SWITCHES, RECEPTACLES, 4 WIRE OUTLETS SHALL
MATCH EXISTING
I I I
■ VERIFY ALL SPECIAL WIRING W/ OWNER PRIOR TO ANY INSTALLATION/ OWNER I
SHALL DIRECT LOCATION OF ALL SPECIAL RECEPTACLES i WIRING
I i
t ALL SMOKE DETECTORS SHALL BE HARD WIRED 4 INTERCONNECTED
I I I
- - - - - - - - - - - - - - - - -- - - - - - - - - i -
I
I
I
I
I
I
- GFId
r- --
I
32/
FIOT
GFI
LIGH I WINE
CWIL
I
I - -
-
GF
SINK
SP,
PIE 1��MIC
O
LIOI� - DR
ER
V
32/
GFI
GAS RANGE W/
i
01
ELECTRICAL IS EXISTING
4 SHALL REMAIN AS IS
ELECTRICAL IS XISTIF
4 SHALL REMAI S IS
w
W/
1
381
DW
38%.
GFI
ELECTRICAL IS EXISTING
4 SHALL REMAIN AS IS
DUPLEX RECEPTACLE
DUPLEX RECEPTACLE TOP HALF SWITCH
DUPLEX RECEPTACLE WEATHER PROOF 4 G,F,i,
@s 220 VOLT RECEPTACLE
WALL MOUNTED LIGHT FIXTURE
CEILING MOUNTED LIGHT FIXTURE
CEILING MOUNTED LIGHT FIXTURE RECESSED
C FLUORESCENT LIGHT FIXTURE
® FAN -LIGHT COMBINATION -SWITCHED SEPARATE
SINGLE POLE SWITCH
THREE WAY SWITCH
IR RHEOSTAT SWITCH
® TELEPHONE JACK
TELEVISION OUTLET
---�IIIII
F
CEILING FAN---------------------EISTING POOL EQUIPMENT ENTI XGWEXISTING
ELECTRICAL
nPOWER
ELECTRICAL IS EXISTING
4 SHALL REMAIN AS IS I
I
I
I
i
I
I
I
I
I
!
I
I
I
I
I
® I
I
I
1
I
j- - - - - - - - - - - - - - - - - - - -�
PROVII E LIGHTED SWITCH
FOR LI�HT AT ATTIC ACCESS
I
I
I
I
I
I
I
I
I
I
I
I
- - -- - - - - - - - - - - - - - - -�
I
I
!
!
I
I
I
I
I
ELECTRICAL IS EXISTING 1
4 SHALL REMAIN AS IS 1
I
I
RELOCATED RETURN I
AIR DUCTED BACK TO
EXISTING AMY
I \`
VERIFY LOCATIONS OF ALL I
SMOKE DETECTORS/THEY 1
SHALL BE PLACED WITHIN ! I
DIRECTLY OUTSIDE OF ALL I
S SLEEPING ROOMS I
I
ALL ARE HARP WIRED ! ' INTERCONNECTED ELE
I CA
L 11 LA
N
1/4"
I
I
I
O I
I yra
/i
i a
C
1 3; v r
I „� � `'•sue ',_�
File COPY
N cl
c�
11
(sue
I�
Q
p
rLnq
o1
on
09
00
t�
�
p
p
ZAA
Ibil9