HomeMy WebLinkAboutCertification for Design Load Compliancei
RECE E-D
YOU, --'=ec '.'s";"'*
Planning & Development Services Department
Building & Code Regulations Division , SEP 2 6 2M7
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 pERMl1-1lIVG
St. Lucie County, FL
Certification for Design Load Compliance
Project Name: s'�i�t\lDA(2� `(�AGt�I(, NuMES .��yER(iet`l�
Project Address: 6 N L-1) WH EWTGt,( LWNe - I —Of 1,
Permit#: Occupancy Type: �'? Construction Type!: V3
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida 3 t t►,( (n Code Fifth Edition with 20 14 Supplements using ASCE 7-10
2. Structure Designed as (check one): Enclosed Partially Enclosed Open
3. Risk Category: _I III III IV Exposure Category: B_C D
i
4. Design Wind Velocity 1"1b mph DASD LRFD End Zone Width: L �' �t ft
5. Mean Roof Height �,o ' - b" ft Roof Pitch: `I :12 Parapet: I�/ ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: ' �� o Zone 2: 0 Zone 3: ' ( ) Zone 4: - 4 � Zone 5: - 4 1� Garage: ' 4
7. Design Loads: Floor: 40/Z` PSF Roof/Dead: "h- PSF Roof/Live: �u Balcony: "ho PSF
Dock: _J� �� PSF Deck: ,JIA PSF Stairs: c16 PSF Fence: ILIA PSF Railings: WA PSF
8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? 4 Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: ZsOo PSF Soil Test Reports Submitted? d Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I
I certify that, to the best of my knowledge and belief, the attached plans & specifications Have been designed to
comply with the applicable structural portions of the building codes currently adopted and Ienforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces s >41�W I////
���� 0 ERti/�i� �-rot
HE�KAN�r:z Vic- 1 Z3X7
i
`�G,,•' \CENV..n �j' Print Name Certl# & Co. Cert Auth.
*; 072387 3 21s N K Atv L
J ure,FS411a` thou s. "Dtyle HvY w NUUNh�FL
Company Name & Address
iS' �• .ORIDP.•'��N��
Rev( 10011.o
�y(� (7,OT4 S%% �N\
1.