Loading...
HomeMy WebLinkAboutCompaction Test9% &P OVA � KELLER, SCHLEICHER.& MacWILLIAM ENGINEERING AND TESTING, INC. MARTIN (772) 337-7755 P.O. BOX 78-1377, SEBASTIAN, FL 32978-1377 II SEBASTIAN (772) 589-0712 PALM BEACH (561) 845-7445 www.ksmengineering.net MELBOURNE (321) 768-8488 FAX (561) 845-8876 E-Mail: KSM@KSMENGINEERING.NET ST. LUCIE (772) 229-9093 C.A.: 5693 ;i FAX (772) 589-6469 SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 2922 1 DATE TESTED February 19, 2018 KSM JOB # : 180581-1d/SS/cv PERMIT # '\ eA \N. U3�C\ i CONTRACTOR Wynne Development JOB LOCATION 41 Arboles De Norte Spanish Lakes Country Club Village ,i Fort Pierce, Florida i, ITEM TESTED Compacted Foundation Fill TEST LOCATION DEPTH * PEN DRY OF SAMPLE READ DENSITY 1. S.W. 0" - 12" 47 108.7 2. N.W. of45 107.3 3. Center 40 105.9 4. N.E. 42 106.4 5. S.E. 47 108.5 Soil Description: Brown Sand with Clay In Place Moisture: 6.5 Percent Optimum Moisture: 12.0 Percent Max. Dry Density: 109.7 P.C. F. @ Test Locations The Density & Penetrometer Readings Indicate the Degree of Compaction Meets Minimum. Reauired • in to Natural Grade No r W - r I YSI V � ishlakes.com W E I G H T P C F D R Y I DRY, PERCENT Z VALUE COMPACTION 1 109.7 99.1 " 11 97.8 96.5 97.0 98.9 it I I I I I I I it I I I 109.0 4—.._.I_.._.I. 107.0 L.._.{� .._.L_.. j._..�.._..+..—.._ 9 10 11 112 13 14 15 /�11 Ronald G. Keller, P.E.: 37293 / SI Lic. No.: 860 / Moisture - % oflDry Weight I it li Julie E. Keller, P.E.: 68366 u