Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Energy Calculation Form & Manual J's
I I FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION I Florida Department of Business and.Professional Regulation - Residential Performance Method I I Project Name: WYNNE THE WINDSOR Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST1 LUCIE COUNTY City,State,Zip: FT.PIERCE, FL, Permit Number: Owner: t'%M,&J_S Jurisdiction: j Design Location: FL,Fort Pierce County:: STj LUCIE COUNTY(Florida Climate Zone 2) I 1. New construction or existing New(From Plans) 9. Wall Types(1432.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul, Exterior R=4.1 1224.00 ftz b.Frame-Wood,Adjacent R=11.0 208.00 ftz 3. Number of units,if multiple family 1 c.N/A R= ftz I 4. Number of Bedrooms 3 d.N/A I R= ftz 10.Ceiling Types (1753.0 sgft.) Insulation Area 5. Is this a worst case? Yes a. Under Attic(Vented) R=30.0 1753.00 ftz 6. Conditioned floor area above grade(ftz) 1753 b. N/A R= ftz Conditioned floor area below grade(ft)z 0 c.N/A R= ftz 11.Ducts i R ftz 7. Windows(151.4 sgft.) Description Area a.Sup:Attic, Ret:Attic,AH:Attic 6 325 a. U-Factor: Sgl, U=0.54 111.36 ftz SHGC: SHGC=0.25 b. U-Factor: Sgl,U=0.55 40.00 ftz 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a.Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ftz SHGC: 13. Heating system I kBtu/hr Efficiency d. U-Factor: N/A ftz a.Electric Heat Pump I 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.850 ft. i Area Weighted Average SHGC: 0.250 14.Hot water systems I 8. Floor Types (1753.0 sgft.) Insulation Area a. Electric Cap:40 gallons' EF:0.970 a.Slab-On-Grade Edge Insulation R=0.0 1753.00 ftz b. Conservation features b.N/A R= ftz None i ' c.N/A R= ftz 15.Credits Pstat Total Proposed Modified Loads: 53.74 Glass/Floor Area: 0.086 PASS Total Baseline Loads: 53.87 ' I I hereby certify that the plans and specifications covered by Review of the planis and O�ZgE ST•q?� this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance] with the Florida Energy Code. i ti PREPAR9 B Before construction is completed r '' DATE: this building will be inspected fort O j a compliance with Section 553.906 * a I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. OD y OWNER/A EN BUILDING OFFICIAL: DATE: DATE: I I I - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R4PU.1.1 and an envelope leakage test report in accordance with R402.4.1.2. bp WNW 7/6/2017 2:07 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software! Page 1 of 5 I I FORM R405-2014 PROJECT 'Title: WYNNE THE WINDSOR Bedrooms: 3 Address§Type: Street Address Building Type: User Conditioned Area: 1753 Lot# 1 Owner: Total Stories: 1 Block/SubDivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 225 Street:I THE WINDSOR Permit Office: ST.LUCIE COUNTY Cross Ventilation: No Countyc ST.LUCIE COUNTY Jurisdiction: Whole House Fan: No City,State,Zip: FT.PIERCE, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: I CLIMATE IECC Design Temp In't Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL VERO_BEACH_MUNI 2 39 90 70 75 I 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1753 14024 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Inh ID Finished Cooled Heated 1 MASTER BEDROO 224 1792 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 ' No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M.BATH 61 488 No 0 1 1 Yes Yes Yes 5 LAUDRY 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 180 1440 No 0 1 1 j Yes Yes Yes 7 DINING/GREAT R 588 4704 No 2 1 Yes Yes Yes 8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes 9 BATH 50 400 No 0 1 Yes Yes Yes � I 10 HALL 25 200 No 0 1 No Yes Yes 11 FOYER 92 736 No 0 1 Yes Yes Yes 12 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes FLOORS I I # Floor Type Space Perimeter Perimeter R-Value Area JoistlR-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio MASTER BEDRO 37 ft 0 224 W _ 0 1 0 I 2Slab-On-Grade Edge Insulatio WIC 1 ft 0 631.ft2 ____ 0 1 0 3 Slab-On-Grade Edge Insulatio MASTER BATH 8 ft 0 56 ftz 0 1 0 I i 4SIab-On-Grade Edge Insulatio M.BATH 7 ft 0 61!;ftz __-- 0 1 0 5 Slab-On-Grade Edge Insulatio LAUDRY 1 ft 0 36 ftz 0 1 0 i j 7/6/2017 2:07 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software i Page 2 of 5 i I FORM R405-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab-On-Grade Edge Insulatio BEDROOM 2 12 ft 0 180,Ift2 _ 0 1 0 7 Slab-On-Grade Edge Insulatio DINING/GREAT 50 ft 0 588 ft2 _I__ 0 1 0 i 8Slab-On-Grade Edge Insulatio KITCHEN 11 ft 0 209162 0 1 0 I 9Slab-On-Grade Edge Insulatio BATH 5 ft 0 50 ft2 _�__ 0 1 0 10SIab-On-Grade Edge Insulatio HALL 1 ft 0 2542 _!__ 0 1 0 i 11Slab-On-Grade Edge Insulatio FOYER 9 ft 0 92 i2 0 1 0 12SIab-On-Grade Edge Insulatio BEDROOM 3 14 ft 0 1M1 ft2 0 1 0 ROOF / Roof Gable Roof Solar SAI Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) i 1 Gable or Shed Metal 1847 ft2 292 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 1753 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) MASTER BEDRO 30 Blown 224 ft2 0.1 Wood 2 Under Attic(Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic(Vented) MASTER BATH 30 Blown 56 ft2 ! 0.1 Wood 4 Under Attic(Vented) M.BATH 30 Blown 61 ft2 j 0.1 Wood 5 Under Attic(Vented) LAUDRY 30 Blown 36 ft2 0.1 Wood 6 Under Attic(Vented) BEDROOM 2 30 Blown 180 ft2 0.1 Wood 7 Under Attic(Vented) DINING/GREAT 30 Blown 588 ft2 0.1 Wood 8 Under Attic(Vented) KITCHEN 30 Blown 209 ft2 0.1 Wood 9 Under Attic(Vented) BATH 30 Blown 50 ft2 0.1 Wood 10 Under Attic(Vented) HALL 30 Blown 25 ft2 0.1 Wood i .11 Under Attic(Vented) FOYER 30 Blown 92 ft2 j 0.1 Wood 12 Under Attic(Vented) BEDROOM 3 30 Blown 169 ft2 0.1 Wood WALLS Adjacent Space Cavity Width HIn Et_eight I Sheathing Framing Solar Below _Ih 1 NE=>W Exterior Concrete Block-Ext InEMASTER BE 4.1 16 0 8 0 128.0 ft2 0 0. 0.5 0 2 SW=>E Exterior Concrete Block-Ext InsMASTER BE 4.1 7 0 8 0 56.0 ft2 0 0 0.5 0 3 NW=>S Exterior Concrete Block-Ext InEMASTER BE 4.1 14 0 8 0 112.0 ft2 0 0 0.5 0 4 NE=>W Exterior Concrete Block-Ext In9MWSTER BA 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0 7/6/2017 2:07 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software! Page 3 of 5 FORM R405-2014 WALLS ' Adjacent Cavity ity Width Height Sheathing Framing Solar Belo w 5 NE=>W Exterior Concrete Block-Ext InsuM.BATH 4.1 7 0 8 0 56.0 ft2 0 0 0.5 0 6 NE=>W Exterior Concrete Block-Ext IntHffDROOM 2 4.1 12 0 8 0 96.0 ft2 0 0 0.5 0 7 SW=>E Exterior Concrete Block-Ext InEWINING/GRE 4.1 30 0 8 0 240.0 ft2 0 0 0.5 0 8 NW=>S Exterior Concrete Block-Ext InEEMNING/GRE 4.1 20 0 8 0 160.0 ft2 0 0 0.5 0 9 SW=>E Exterior Concrete Block-Ext InsuKITCHEN 4.1 11 0 8 0 88.0 ft2 0 0 0.5 0 10 NE=>W Exterior Concrete Block-Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0 11 SE=>N Exterior Concrete Block-Ext Insul FOYER 4.1 8 0 8 0. 64.0 ft2 0 0 0.5 0 12 SW=>E Exterior Concrete Block-Ext Insul FOYER 4.1 1 0 8 0 8.0 ft2 0 0 0.5 0 13 NE=>W Exterior Concrete Block-Ext In!REDROOM 3 4.1 13 0 8 0 104.0 ft2 0 0 0.5 0 14 SW=>E Exterior Concrete Block-Ext InMEDROOM 3 4.1 1 0 8 0 8.0 ft2 0 0 0.5 0 15 N=>SW Garage Frame-Wood BEDROOM 3 11 26 8 208.0 ft2 0.23 0.5 0 DOORS # Ornt Door Type Space Storms U=Value Width Height Area Ft In Ft In 1 SE=>N Insulated FOYER None 39 3 3 6 8 21.7 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 NW=>S 3 Metal Low-E Single Yes 0.54 0.25 32.4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 NE=>W 5 Metal Low-E Single Yes 0.54 0.25 6.9 ft2 1 ft 0 in A ft 4 in None None 3 NE=>W 6 Metal Low-E Single Yes 0.54 0.25 16.2 ft2 1 ft 0 in !1 ft 4 in None None 4 SW=>E 7 Metal Low-E Single Yes 0.54 0.25 39.8 ft2 1 ft 0 in ,1 ft 4 in None None 5 NW=>S 8 Metal Low-E Single Yes 0.55 0.25 40.0 ft2 8 ft 0 in 1 ft 4 in None None 6 NE=>W 13 Metal Low-E Single Yes 0.54 0.25 16.2 ft2 1 ft 0 in ;1 ft 4 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 806 ft2 806 ft2 26 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1636.1 89.82 168.92 .2598 7 7/6/2017 2:07 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software. Page 4 of 5 I - , FORM R405-2014 HEATING SYSTEM r • # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:8.5 34.8 kBtu/hr i 1 sys#1 COOLING SYSTEM i # System Type Subtype Efficiency Capacity AirlFlow SHR Block Ducts 1 Central Unit Split SEER: 15 34.8'kBtu/hr cfm 0.85 1 sys#1 � I HOT WATER SYSTEM # System Type SubType Location EF Cap User SetPntI Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg! None I I SOLAR HOT WATER SYSTEM ! i FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ftZ DUCTS' ---Supply— —Return-- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 325 ftz Attic 95 ft2 ' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling Jan Feb Mar Apr May rl Jun ri Jul X Aug jXj Sep Oct Nov Dec Heating Jan Feb Mar Apr May Jun Jul J�jAug Sep Oct �Nov Dec Venting € Jan Feb ki Mar Apr i May Jun Jul Aug Sep Oct lX Nov Dec Thermostat Schedule: HERS 2006 Reference Hours ! Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 i Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 i 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 I, I i t I 7/6/2017 2:07 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software' Page 5 of 5 I I FORM R405-2014 TABLE 402.4.1.1 I AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE WINDSOR Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST. LUCIE COi NTY City,State,Zip: FT.PIERCE, FL, Permit Number Owner: Jurisdiction: Design Location: FL,Fort Pierce I COMPONENT CRITERIA i CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a(sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. I The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be;installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/doorjambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. I, The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. I Exposed earth in unvented crawl spaces shall tie covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors I' 7/6/2017 2:07 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 i FORM R405-2014 i ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD, , a , ESTIMATED ENERGY PERFORMANCE INDEX` 100 The lower the EnergyPerformance Index, the more efficient the home. THE WINDSOR, FT. PIERCE, FL� I 1. New construction or existing New(From Plans) 9. Wall Types I Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul, Exterior R=4.1 1224.00 ft2 b.Frame-Wood,Adjacent R=11.0 208.00 ft 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? 10.Ceiling Types j Insulation Area Yes a.Under Attic(Vented) R=30.0 1753.00 ftZ 6. Conditioned floor area(ft2) 1753 b.N/A R= ft2 c.N/A R= ft2 7. Windows- Description Area 11.Ducts R ft2 a. U-Factor: Sgl,U=0.54 111.36 ft2 a.Sup:Attic, Ret:Attic,AH:Attic 6 325 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.55 40.00 ft2 SHGC: SHGC=0.25 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 34.8 SEER:15.00 SHGC: d. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 2.850 ft. a.Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average SHGC: 0.250 8. Floor Types Insulation Area 14.Hot water syst ims Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1753.00 ft2 a. Electric b. N/A R= ft2 EF:0.97 c.N/A R= ft2 b. Conservatio l features None 15.Credits Pstat i I certify that this home has complied with the Florida Energy Efficiency Code for Building ZtiE ST Construction through the above energy saving features which will be installed (or exceeded) y04 _ ATBo in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: n Address of New Home ��'c�j�aS �� ( City/FL Zip: ^?��tce, *Note: This is not a BuildingEnergy Rating. If our Index is below 70 our Nome may uali for energy efficient 9Y 9• Y � Y Y q fY 9Y mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list'of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. I **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 7/6/2017 2:07 PM EnergyGauge@ USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 i -�d- wrightsoft° Project Summary I Date: Entire House ! By: QUICK CALCS,INC. j 317 St.LUCIELN.,FT.PIERCE,FL 34946 Phone:772466-6799 Fax 772-466-6796 Email:;QUICKCALCS AOL.COM. Project Inf • - • • For. WYNNE DEVELOPMENT THE WINDS,O�R,;�FT. 4PIERCE, FL Notes: I Design Information Weather Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db. 70 OF Inside.db 75 OF Design TD 28 OF Design TD i 15 OF Daily range L .. Relative humidity i 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment:Load Sizing Structure 18467 Btuh Structure I 17655 Btuh Ducts 6190 Btuh Ducts Central vent(O.cfm) 0 Btuh Central vent(0 cfm) I 9 0 Btuh none Humidification 0 Btuh BI wer e) 0 Btuh Piping 0 Btuh Equipment load 24657 Btuh Use manufacturers data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 25645 Btuh Method Simplified Latent Cooling Equipment Load Sizing . Construction quality Average Fireplaces 0 Structure 2453 Btuh Ducts 2554 Btuh Central vent(0 cfm) 0 Btuh Heatingg Cool' (pone) (none) Area(ft2) 1753 1753 Equipment latent load i 5007 Btuh Volume(ft3) 14741 14741 Air changeslhour 0.38 0.20 Equipment total load 30652 Btuh Equiv.AVF(cfm) 93 49 Req. total capacity at 0.70 SHR 3.1 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Camer Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC536A*030 Cond 25HBC536A*030 AHRI ref . 7914585 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER Heating input Sensible cooling 24360 Btuh Heating output 34600 Btuh @ 47OF Latent cooling 10440 Btuh Temperature rise 27 OF Total cooling 34800 Btuh. Actual air flow 1160 cfm Actual airflow 1160. cfm Air flow factor 0.047 cfm/Btuh Air flow factor j 0.043 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat- Load sensible heat ratio 0.84 Capacity balance point=34 OF , Backup: Input=7 kW, Output=23009 Btuh, 100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8thiEd. wrightsoft` 2017-Apr-10 1 7:19:28 .�- Right-Suite®Universal 201717.0.14 RSU08101. Page 1 ...k Calcs(Documents\WYNNE-THE WINDSOR-REVISED.rup Calc=MJ8 Front Door faces: N I I wrightsofe Right-M)Worksheet Job: Entire House bate: QUICK CALCS, INC. sy. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS AOL.COM 1 Room name Entire House MASTER BEDROOM 2 .Bq)osed wall 153.0 ft 45.0 ft 3 Room height 8.4 ft d, 8.0 ft heat/cool 4 Room dimensions 1 1.0 x 280.0 ft 5 Room area 1753.0 ftz 280.0 ftz Ty Construction U-walue Or HTM Area (ft-) Load Area (ft� Load number (Btuh/ft'`F) (Btuhlft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P(S Heat I Cool Gross WP/S Heat Cool 6 . 13A4b s 0.143 ne :4.00 2.55 488 448 .1795 1141 192 192 769 489 :1A clom 1.270 ne 35.56 70.43 7 0 247 488 i 0` :.0. :0 0 14knc1om 1;270 ne 35:56 7043 16 0 581 1151 0 0: 0 -0 1A c1om ; 1:270 .ne. 35 56 45 24. 16 0 581 739 I 0 0 0 0 11 13A-4ocs 0.143 se 4.00 2.55 64 41 165 105 0 0 0 0 0 11D0 0.390 .se- ._ 10.92, 11.31 23 23 248 257 j 0, 0 0 . - 0 13A-0ocs 0.143 sw 4:Q0 2:55 437 396 1564 1007 j56 56 724 143 4A5 tom 0:770 .sw 2156 2753 41 45. 893 1140 0 0 0 0 13A4ocs 0.143 nw 4.00 2.55 290 217 867 551 112 79 318 202 IA-c1om 1.270 nw 35.56 45.24 33 0 1162 1478 133 0 1162 . 1478 4A5-2omd,. 0.770.nw. 21.56 36.90 .41 . 0 880, 1505 0 0 0 0 :12C-0sw 0:091 255 ..1:28 ' 308 308:` "784 395 .. I 0;_ 0: 0 :;0. C 16A-30md 0.032 - 0.90 2.32 1753 1753 1571 4067 280 280 251 650 F 22A tpl ;: 0:989 2Z6'9.; 0:00. --1753 :._:153; '-.'4237 C. . -o 280 :,. 45'' 1246 ;0 I i i 6 c)AED ecursion 1360 600 1 53EnveloRe loss/ ain I 3970 3561 12 a) Infiltration 2873 810 809 228 b) Room ventilation 0 0 0 0 13 Iritemal gains: Occupants @ 230 2 460 0 0 Appliances/other 1000 0 Subtotal Qines 6 to 13) 18467 176551 1 4779 3789 Less ekemal load 0 0 I 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 18467 17655 4779 3789 15 Duct loads 34% 53% 6190 9340 340% 53% 1602 2005 Total room load 24657 26995 6380 5794 Air required(cfm) 11M' j 1160 300 249 Calculations approved by ACC A to meet all requirements of Manual J 8thl Ed. 414- wrightsoft- 2017-Apr 10 17:19:28 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 1 k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc=MJ8 Front Door faces: N I i +�wrightsoft' Right-M Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS ,AOL.CO.M 1 Room name WIC I M.BATH 2 F)osed wall 0 ft 7.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft, heat/cool 4 Room dimensions 7.0 x 9.0 ft 1.0 x 61.0 ft 5 Room area 63.0 ft2 61.0 ft2 Ty Construction U-value Or HTM Area " (ft') Load l Area I (ft') Load number (Btuh/ft--F) (Btuhlft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat (Cool Grossl WP/S Heat cool 6 13AAccs. 0.143 ne 4.00 2.55 0 0 0 0 56 49 196 125 1A c1om 1:270 ne: 35:58 70.43 0 0 0 0, 7 '0. '. 247 488 ;1Ac1om .:` 1;270 ne 35.56 7043 0 0 F.6 0 0 0 0 0 1Ac1om 1:270 -ne" . " 35:56 45.24 0 . 0 0 i 0 0' 0: 0 '0' 11 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 VLr 11D0 0:390 .se. . 10.92, 11.31. 0 0 . 0 0- f 0 0 0 0 �D . 13A-0ocs •'. 0:143 sw 400 2,55 0 0 0 " . 0 '' �.0 0 0 ;o,. aAStom O:T/o swr 2]:56: 27]53 0 o p p .1 0 . .0 0_ o 13A4ocs 0:143 nw 4.00 2.55 0 0 0 0 10 0 0 0 1A-c1om 1.270 nw 35.66 45.24 0 0 0 0 0 0 0 0 4A5-2omd 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0, P 12C Osw, 0:091 -."2.55, -_ 1.28 0 .0 0 0 .0> 0 =0 0 C 16A 30md 0.032 - 0.90 2.32 63 63 56 146 61 61 55 142 0 61 7.. 1 0 0:989 27.69 0:00 63:: 0 0 I' l j 6 c)AED excursion -5 -26 i Envelope loss/gain 56 141 692 729 12 a) Infiltration 0 0 126 35 b) Room ventilation 0 0 0 01 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 56 141 817. 764 Less extemal load 0 0 i 6 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 56 141 817 764 151 uct loads 34% 53% 19 75 31%1 53%1 2741 404 Total roam load 75 216 i 1091 1168 Air required(cfm) 4 9 511. 60 Calculations approved byACCA to meet all requirements of Manual J 8th,Ed. 4fl w- right 2017-Apr-10 1soft' Right-Suite®Universal 2017 17.0.14 RSU08101 Page age 2 k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc=MJ8 Front Door faces: N I I -�-wrightsoft° RighW@ Worksheet °b Entire House °ate` � BY: QUICK CALCS, INC. i 317 ST..LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-0663796 Email:QUICKCALCS@AOL.COM 1 Room name LAUDRY BEDROOM 2 2 • Eq)osed wall 0 ft 12.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 6.0 x 6.0 ft 1 15.0. x 12.0 ft 5 Room area 36.0 ft2 180.0 ftz Ty Construction U-value Or HTM Area (fF) Load! Area j (ftj Load number (Btuh/ftz-°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Grossj WP/S Heat Cool 6 13AAocs"- 0.143 ne, :4.00. 2.55 0 0. 0 0 i96 80 319 203 1Ac1om ._ ?270 ne: W56 70.43 0 0 0 0" 0 =' 0 0 ::'0. 1A�1om i 1;270 ne` 35.56 Z0:43 >".0 0 0 0 16 . 0' 561 1151 ".XWrn 1 270 ne" 35:56 45:24 0 0 0 i 0. , 0 0 0. 0 11 13A-0ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 I-D 11130 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0. V�/ 13A�acs. 6.143 s W' 4 00 2:55 0 0 0 0 .' 1 0 .' 0 0 0 G: 4A5.2om _ .. 0 776 sw. .2156. 27:53 0 0 0 0 . 0. 13AAocs 0.143 nw 4.00 2.55 0 0 0 0 i 0 0 0 0 IA-c1om 1.270 nw 35.56 45.24 0 0 0 0 ; 0 0 0 0 . 4A5 2omd- 0.770, nw 21.56 _ 36.90 0 0 0 0 0 - 0 0 0 0:091" .- -2:65: 1:28 .. 0 0` 0` 0 I 0 0 C 16A30md 0.032 - 0.90 2.32 36 36 32 84 180 180 161 .418 2tpl . .: 00 -36 _0F 0 7 , A 180.;., ..:.12 : .`332 0, j - { 6 c)AED excursion -3 j -60 Envelope loss/gain 32 81 1394 1711 12 a)' Infiltration 0 0 216 61 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal Oines 6 to 13) 32 81 1609 1772 i Less external load 0 0 .6 0 Less transfer 0 0 0 0 Redistribution 6 14 6 14 14 Subtotal 38 95 1615 1786 15 Duct loads 34% 53% 13 50 34% 53% 541 945 Total room load 51 145 I 2156 2730 Air required(cfm) 1 21 6 101 117 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -FIA- wrightsoft- 2017-Apr-10 17:19:28 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 3 k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc=MJ8 Front Door faces: N i I I • +-'wrightsoft Right-J®Worksheet IJob: Entire House ;Date: QUICK CALCS, INC. IBy: i 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772.46M799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name DINING/GREAT ROOM KrrCHEN 2 Eposed wall 50.0 ft 1 11.0 ft 3 Room height 8.9 ft heat/cool 8.9 ft heat/cool 4 Room dimensions 1.0 x 588.0 ftl 1 19.0. x 11.0 ft 5 Room area 588.0 ft= 209.0 ft= Ty Construction U-value Or HTM Area (ft-) Load Area 1 number (Btuh/W-'F) (Btuh/ft=) or perimeter (ft) (Btufi) or perim =eter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool 6 = 13A-4ops. 0.143 •ne 4.00 2.55. 0 0 0 0 0 0 . 0 o 1Ac1om 1.270 ne 3556, 70.43 0 0 0 0 i 0 0 0 0 1Ac1om 1.270 .he, 3556: 70:43 o 0 0. 0 10 0 0 0 1Aclom .1:270 he 35.56 45:24 ..0 : 0 0 :: p. ':: ' 0 0 0 -p 11 yJ 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 t-D- 11D0 0,390 se.. 10.92,- 11.31 0 0 0 0 0 0 0 0 V�/ 13A-0oes 0.143-sw 4 09 2.55 267 226 903 574 98, 98 392 249 L-G gA5 tom Ot770 sw 21:56- 2Z.53 41 22 893 s 1140 p p" p 0 13AAocs .0143 nw 4.00 2.55 178 137 549 1 349 1 0 0 0 0 1Aclom 1.270 nw 35.56 45.24 0 0 0 0 1 0 0 0 0 4A5-2omd 0.770 nw 21.56 36.90 41 0 880 1505 1 0 0 0 0 P ;'12C-0sw;::. .. 0.091";"=- 2.55 "_1:28 :: 0''- 0`: 0 0'' 116 :. -,116":: 295 148' C 16A30md 0.032 - 0.90 2:32 588 588 527 1364 209 209 187 485 Ftpl .:. . . _:: .. . 0989 27.69 '. -0.00. 588 :. 50` . ..'.:1385 1' 0 : `.209.. .': 11 305 p I' I I ; I 4. .. .r T. 6 c)AED wcursion 1004 I -64 Envelope loss/gain 5136 5937 ! 1179 818 12 a) Infiltration 1000 282 220 62 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 ! 0 0 Appliances/other 0 1 1000 Subtotal Qines 6 to 13) 6136 6679 1399 1880 Less extemal load o 0 0 0 Less transfer 0 0 0 0 Redistribution 6 , 14 1 0 0 14 Subtotal 6142 6693 1399 1880 15 Duct loads 34% 53% 2058 WA 34% 53% 469 995 TTotal room load 8200 10234 1867 2875 Ajr required(cfm) 386 440 88 124 1 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wr.igt�tsoft' 1 ! 2017-Apr-10 17:19:28 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 4 ...k CalcsIDocuments\WYNNE-THE WINDSOR-REVISED.rup Calc=MJ8 Front Door faces: N I i - I • wrightsb Right-M Worksheet Jbb: Entire House Date: By: QUICK CALLS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name BATH HALL 2 Exposed wall 5.0 ft 0 ft 3 Roam height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 10.0 x 5.0 ft 5 Room area 50.0 ft2 25'0 ft2 5.0 x 5.0 ft Ty Construction Ll-value Or HTM Area (ft2) Lo ad Area I (ft2) Load number (Btuhlft2--T) (Btu 2) or perimeter (ft) (Btuh) I or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross I WP/S Heat Cool 6 : 13A-4o6s 0.143 ne 4:00 2.55 40 40 160 102 0 0 0 0 1A�1om ; 1.270 ne 35 56 70.43 0 0 0 0 O 0 0 0. 1Ac1om 1-270 ne 355.6 70.43: 0 0 0 P 0 _ 10 .0 0 :0 1A clom 9 270 ne: 35.56. .45.24 0 0 0 0. 0' .. '0. 0 11 13A4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 �-D 11D0 0.390 se 10.92 11. 1 3 0 0 0 0 0 0_ 0 0 13A�ocs 0143 sw: 400; 255. 0.. 0 0 I, .. p - . ?p U p p 4AS.tom :.:. . 0:770 svr.- 21'. :. 27.53 0' 0 0 0 0 0 ` 0. .0 13A4ocs 0.143 nw 4.00 2.55 0 0 0 0 10 0 0 0 IA-c1om 1.270 .nw 35.56 45.24 0 _ 0 0 0 ,0 0 0 0 _4A5-2omd_ 0..770 nw 21.5.6., 36.90 0 0. 0 0 0 0 0 0 :P 12C Osw:; 0:091 : - 2:55' 1:28; 0 .= 0 0 _ 0 ; �0 0:' 0. 0 C 16A 30md 0.032 - 0.90 2.32 50 50 45 116 25 25 22 58 P F 22A t I. 0:989 .= 2769 000 5U 5 138 : . . 0 25 . j I • it I w. - i ! 6 c)AED excursion -8 I -2 Envelope loss/gain 343 210 I 22 56 12 a) Infiltration 90 25 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 ; 0 Subtotal pines 6 to 13) 433 235 22 56 Less extemal load 0 0 0 0 Less transfer 0 0 0 - 0 Redistribution 6 14 -22 -56 14 Subtotal 439 249 0 0 15 Duct loads 34'/0 53% 147 132 34%1 53°/u .0 0 Total room load 586 381 0 0 Air required(cfm) 28 16 i .0. 0 I Calculations approved byACCA to meet all requirements Of Manual J 8thlEd. . wrightsoft• 2017-Apr-1017:19:28 AA Right-Suite@ Universal 2017 17.0.14 RSU08101 Page 5 .:.k CalcslDocument"s\WYNNE-THE WINDSOR-REVISED.rup Calc=MJ8 Front Door faces: N I I i - -wrightsoft° Right.40 Worksheet Job: Entire House Date: _ By QUICK CALCS, INC. � 317 ST LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466.6799 Fax 772-466-6796 Email;QUICKCALCS@,\OL.COM 1 Room name FOYER BEDROOM 3 2 Exposed wall 9.0 ft j 14.0 ft 3 Room height 8.0 ft heaUcool I8.0 ft heat/cool. 4 Room dimensions 1.0 x 92.0 6 , 13.0 x 13.0 ft 5 Room area 92.0 ftz 1169.0 ft2 Ty Construction U-value Or HTM Area (ft') Load Area I (ft') Load number (Btuh/ftL°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 .W.. -13A4ocs - 0.143 ,ne 4.00 2"55 0 0 0 0 104 88 351 : 223 IA-c1om> 1.270 ne 3556 70.43 0 0 0 0 0 0. .0 0 L:LGT1Xc1offi :1.270 .ne- 35.66 70:43. .0 0 0 0 0 �.0 0 A o.onn; .1.270:ne. . 35.56 c4524'. 0, 0 " ' 0 L:_ 0 ' •: 116 0: ;581. 739. 7A 13A4ocs 0.143 se 4.00 Z55 64 41 165 105 0 0 0 0 11 VE-D 11130 0.390 se- 10.92 11.31 23 23 248 257 0 0 0 0 13A-0ocs 0:143 sw' AGO 266 .g A2 I' 20 L_ 8 8 32 20; .'4A5.2om 0.770-sw. 21.56', 27.63" 0 0 0 0 .0 0 13A4ocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 1Aclom 1.270 nw 35.56 45;-24 0 0 0 0 0 0 0 0 4A5.29md 0.770 nw 21.56, 3¢190 0 0 0 0 0 0 0 0 P. 12C-0sw;: Ob91 `Z65 41.28. 88 68 `224 113. 104 104 265 133 C 16A 30md 0.032 0.90 2.32 92 92 82 213 169 169 151 392 F 22A-tp1. 0.989 - 27.69 Roo." 92 9 ..:. ''249 0: '• " 169` 0 I i I• j i I _ I , i 6 c)AED wcursion -25 -52 Envelope loss/gain 664 1002 1768 1456 12 a) Infiltration 162 46 252 71 b) Room ventilation 0 0 0 0 i 13 Internal gains: Occupants @ 230 0 0 10 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1163 730 2020 1527 Less extemal load 0 0 0 0 Less.transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1163 730 j 2020 1527 151 Duct loads 34% 53% 390 386 34% 53% 677 808 Total room load 1553 1116 2697 2335 Air required(cfm) .73 48 1 1 127 100 I Calculations approved byACCA to meet all requirements of Manual J 8thlEd. wrightsoft' I M17-Apr-1017:19:28 A&K Right-Suite@ Universal 2017 17.0.14 RSU08101 Page 6 k 6alosIDocuments\WYNNE-THE WINDSOR-REVISED.rup Cale=MJ8 Front Door faces: N Duct.S stem Summary Job:. -�- wrightsoft y Date: Entire House By: QUICK CALCS,INC. 317$T.LUCIE LN.,FT PIERCE,FL 34946 Phone:•772466-6799,Fax 772466-6796 Email:,OUICKCALCS@/1QLCOM Project • • For: WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL 1 j Heating Cooling- Extemal static pressure 0.60 in H2O 0.50,in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0:50 .in H2O 0.50 in H2O Supply Ireturn available pressure 0.250/0.250: in H2O 0.250/0.250 in H2O Lowest friction rate 0.273 in/100ft 0.273 in/100ft Actual air flow 1160 cfm 1160 cfm Total effective length.(TEL) 183 t' Supply Branch DetailTable I 1 Design Htg Clg Design Diam. H x W Duct Actual Ftg.Egv. Name (Btuh) (cfm) (Cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk BATH .h 586 28 16 0.372 4.0 Ox0 VIFx 19.5 115.6 st1 BEDROOM 2 c 2730 101 117 0.384 7.0 OxO VIFx 15.0 115.0 st1 BEDROOM 3 h . 2697 127 100 0.353 6.0 OxO VIFx 26.8 115.0 st1 DINING/GREAT ROOM C 3411 129 147 0.292 7.0 Ox 0 VIFx 36.5 135.0 st2 DINING/GREATROOM-B C 3411 129 147 0.371 7.0 OxO VIFx 19.9 115.0 SO DINING/GREAT ROOM-C C 3411 129 147 0.278 ' 7.0 Ox 0 VIFx 44.9 135.0 st2 FOYER h 1553 73 48 0.490 4.0 NO VIFx I7.0 95.0 KITCHEN C 2875 88 124 0.366 . 6.0 OxO VIFx 21.8 115.0 st1 LAUDRY C 145 2 6 0.371 4.0 Ox 0 VIFx 19.9 115.0 st1 M.BATH li 1091 51 50 0.282 6.0 Ox0 VIFx 42.3 135.0: st2 MASTER BEDROOM h 3190 150 124 0.273 6.0 Ox0 VIFx 48.4 135.0 st2 MASTER BEDROOM-A . h 3190 150 124 0.284 6.0 Ox 0 VIFx 40.9 135.0 st2 WIC c 216 4 9 0.292 4.0 Ox0 VIFx 36.0 135.0 st2 I Supply Trunk Detail , • - � Trunk Htg Clg Design Veloc Diam H x W Duct Name ' Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 612 602 0,273 780 12.0 0 x" 0 VinlFlx st1 st1 Peak AVF 1087 1112 0.273 796 16:0 0 x 0 VinnX i I wrl htsoft' I 2017-Apr-10 17:19:29 9 RightSuite®Universal 2017 17.0.14 RSU08101 Page 1 ACCA ...k Calcs%Documents%WYNNE-THE WINDSOR-REVISED.rup Cale=MJB 'Front Door faces: N I I Return Branch Detail ITable I Grille Htg Clg TEL Design Veloc Diam H ix W Stud/Joist Duct Name -Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) . Matf Trunk rb1 Ox0 . 1160 1160 .0 0 0 0 Ox 0 VIFx I I I I I I I I I I I I I I I I I I I. I I 2017-Apr-10 17:19:299 -�- wrightsoft° .Right-Suite®Universal 2017 17.0.14 RSU08101 Page 2 ...k"Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc=MJ8 Front Daor faces: N I