Loading...
HomeMy WebLinkAboutRevisions (2) OFFICE USE ONLY: DATE FILED: PERMIT# 1711-0379 REVISION FEE: RECEIPT# 1 i I PLANNING&DEVELOPMENT SERVICES ® BUILDING&CODE REGULATION DIVISION 2300 VIRGINIA AVENUE ® FORT PIERCE,FL 34982-5652 1 (772)462-1553 FAX(772)1,462-1578 APPLICATION FOR BUILDING PERMIT,REVISIONS PROJECT INFORMATION 1. LOCATION/SITEArboles Del Norte ADDRESS: 41 2. DETAILED DESCRIPTION OF PROJECT REVISIONS: Changing to Impact Windows and Adding a 6x10 slab off rear of home • I I 1 3. CONTRACTOR INFORMATION'. STATE r �� STATE of FL REG./CERT.#: ST. iI CON BUSINESS NAME: orp0 tl r� ;iy Y a<<, QUALIFIERS NAN ADDRESS. 0 South U wy. ui a CITY: Fort St. Lucie STATE: PHONE(DAYTIME): - 4. OWNER/BUILDER INFORMATION: ' NAME: Wynne Building Corporation ADDRESS: 8000 SouthHwy. 1 Suite 402 CITY: STATE: FL ZIP: 34 2 PHONE: (772) 878-5513 FAX: (772) 878-7656 " I 5. ARCHITECT/ENGINEER INFORMATION: NAME: BRADEN&BRADEN ADDRESS: CITY: STUART STATE: FL ZIP: 34996 PHONE(DAYTIME): (772) 287-8258 FAX: Revised 07/22/2014 Ffie co �^ F77a <:: �' 'tea EIa"'•;-., `,.�, c 9 61 l^Yt. i F N®t Inc(ud� ti This 'ermt i 6'. t 't IN > r y u�Ao\ FORM R405-2017 i FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST.LUCIE COUNTY f i City,State,Zip: FT. IE1„FL��S�\� Permit Number: Owner: �b Jurisdiction: Design Location: FL,Fort Pierce County:: St.i Lucie(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1432.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul, Exterior R=4.1 1224.00 ft2 b. Frame-Wood,Adjacent R=11.0 208.00 ft2 3. Number of units, if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1753.0 sqft.) Insulation Area a. Under Attic(Vented) R=30.0 1753.00 ft2 6. Conditioned floor area above grade(ft2) 1753 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c. R= ft2 11. Duct s � R ft2 7. Windows(151.4 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attil 6 225 a. U-Factor: Sgl, U=0.63 111.36 ft2 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 40.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a.Central Unit I 34.8 SEER:15.00 q. U-Factor: N/A ft2 I SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat(Pump 34.8 HSPF:8.50 SHGC: i Area Weighted Average Overhang Depth: 2.850 ft. Area Weighted Average SHGC: 0.239 14.Hot water systems 8. Floor Types (1753.0 sqft.) Insulation Area a.Electric Cap:40 gallons' a.Slab-On-Grade Edge Insulation R=0.0 1753.00 ft2 EF:0.970 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.086 Total Proposed Modified Loads: 53.83 PASS 1 Total Baseline Loads: 53.85 I I hereby certify that the plans and specifications covered by Review of the plans and OiT>r1E Srg1� this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compl' nce with lo'It a PREPAR D Y: Befo I e DATE: "` this b ild ill i o t7 com o 0 I hereby certify that this building,as designed, is in compliance Flori t , 5� with the Florida Energy Code. COD yy� v OWNER/'�\ + BUIL-I a I - DATE: DAT i - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. 1 -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). I Joe C013V 4/16/2018 9:09 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 , 1 FORM R405-2017 PROJECT Title: WYNNE THE WINDSOR IM Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1753 Lot# Owner Name: Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 225 Street: THE WINDSOR Permit Office: ST.LUCIE COUNTY Cross Ventilation: No County: St.Lucie Jurisdiction: Whole House Fan: No City,State,Zip: FT.PIERCE, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS I Number Name Area Volume � `I 1 Entire House 1753 14024 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfIID Finished Cooled Heated i 1 MASTER BEDROO 224 1792 No 0 1 1 ; Yes Yes Yes 2 WIC 63 504 No 0 1 ', No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M.BATH 61 488 No 0 11 Yes Yes Yes 5 LAUDRY 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 180 1440 No 0 1 1 Yes Yes Yes 7 DINING/GREAT R 588 4704 No 2 1 Yes Yes Yes 8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes 9 BATH 50 400 No 0 1 Yes Yes Yes i 10 HALL 25 200 No 0 1 '' No Yes Yes 11 FOYER 92 736 No 0 1 Yes Yes Yes 12 BE DROOM 3 169 1352 No 0 1 1 ; Yes Yes Yes I FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist)R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio MASTER BEDRO 37 ft 0 224 ft2 Y 0 1 0 2 Slab-On-Grade Edge Insulatio WIC 1 ft 0 63 ft2 0 1 0 i- 3 Slab-On-Grade Edge Insulatio MASTER BATH 8 ft 0 56 ft2 1 __ 0 1 0 i 4SIab-On-Grade Edge Insulatio M.BATH 7 ft 0 61 ft2 0 1 0 5SIab-On-Grade Edge Insulatio LAUDRY 1 ft 0 36 ft2 __ 0 1 0 I i I 4/16/2018 9:09 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software" Page 2 of 5 FORM R405-2017 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist'R-Value Tile Wood Carpet 6 Slab-On-Grade Edge Insulatio BEDROOM 2 12 ft 0 180 ft2 it__ 0 1 0 7SIab-On-Grade Edge Insulatio DINING/GREAT 50 ft 0 588 ft2 0 1 0 i 8 Slab-On-Grade Edge Insulatio KITCHEN 11 ft 0 209 ft2 __ 0 1 0 9 Slab-On-Grade Edge Insulatio BATH 5 ft 0 50 ft2 0 1 0 1 OSlab-On-Grade Edge Insulatio HALL 1 ft 0 25 ftZ i�__ 0 1 0 11Slab-On-Grade Edge Insulatio FOYER 9 ft 0 972 J___ 0 1 0 12SIab-On-Grade Edge Insulatio BEDROOM 3 14 ft 0 169 ft2 __ 0 1 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1847 ft2 292 ft2 Light i 0.6 N'I I 0.9 No 0 18.4 ATTIC I V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 1753 ft2 N 1 N f f CEILING 11 # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) MASTER BEDRO 30 Blown 224 ft2 0.1 Wood 2 Under Attic(Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic(Vented) MASTER BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic(Vented) M.BATH 30 Blown 61 ft2 0.1 Wood 5 Under Attic(Vented) LAUDRY 30 Blown 36 ft2 0.1 Wood 6 Under Attic(Vented) BEDROOM 2 30 Blown 180 ft2 0.1 Wood 7 Under Attic(Vented) DINING/GREAT 30 Blown 588 ft2 0.1 Wood 8 Under Attic(Vented) KITCHEN 30 Blown 209 ft2 0.1 Wood 9 Under Attic(Vented) BATH 30 Blown 50 ft2 0.1 Wood 10 Under Attic(Vented) HALL 30 Blown 25 ft2 0.1 Wood 11 Under Attic(Vented) FOYER 30 Blown 92 ft2 0.1 Wood 12 Under Attic(Vented) BEDROOM 3 30 Blown 169 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below Ft in 1 NE=>W Exterior Concrete Block-Ext IngMASTER BE 4.1 16 0 8 0 128.0 ft2! 0 0 0.5 0 2 SW=>E Exterior Concrete Block-Ext IndMWSTER BE 4.1 7 0 8 0 56.0 ft2 0 0 0.5 0 3 NW=>S Exterior Concrete Block-Ext InIMASTER BE 4.1 14 0 8 0 112.0 ft2" 0 0 0.5 0 4 NE=>W Exterior Concrete Block-Ext InsMASTER BA 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0 r 4/16/2018 9:09 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 i FORM R405-2017 WALLS Adjacent(')Ent In IAIqll Type Space CavR_Vaity Width H11 le Et In Ft�eight Sheathing Framing Solar Below _in 5 NE=>W Exterior Concrete Block-Ext InsuM.BATH 4.1 7 0 8 0 56.0 ft2 0 0 0.5 0 6 NE=>W Exterior Concrete Block-Ext InfiffDROOM 2 4.1 12 0 8 0 96.0 ft2 0 0 0.5 0 7 SW=>E Exterior Concrete Block-Ext IndMNING/GRE 4.1 30 0 8 0 240.0 ft2 i 0 0 0.5 0 8 NW=>S Exterior Concrete Block-Ext InINNING/GRE 4.1 20 0 8 0 160.0 ft2 0 0 0.5 0 _ 9 SW=>E Exterior Concrete Block-Ext InsuKITCHEN 4.1 11 0 8 0 88.0 ft2 'I 0 0 0.5 0 10 NE=>W Exterior Concrete Block-Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0 11 SE=>N Exterior Concrete Block-Ext Insul FOYER 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0 12 SW=>E Exterior Concrete Block-Ext Insul FOYER 4.1 1 0 8 0 8.0 ft2 0 0 0.5 0 _13 NE=>W Exterior Concrete Block-Ext InEEDROOM 3 4.1 13 0 8 0 104.0 ft2 0 0 0.5 0 14 SW=>E Exterior Concrete Block-Ext ImUDROOM 3 4.1 1 0 8 0 8.0 ft2 0 0 0.5 0 _15 N=>SW Garage Frame-Wood BEDROOM 3 11 26 8 208.0 ft2 ! 0.23 0.5 0 DOORS # Ornt Door Type Space Storms ULValue Width Height Area Ft9� In Ft In 1 SE=>N Insulated FOYER None '.39 3'I 3 6 8 21.7 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>S 3 Metal Low-E Single Yes 0.63 0.25 N 32.4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 NE=>W 5 Metal Low-E Single Yes 0.63 0.25 N 6.9 ft2 1 ft 0 in '11 ft 4 in None None 3 NE=>W 6 Metal Low-E Single Yes 0.63 0.25 N 16.2 ft2 1 ft 0 in 1 ft 4 in None None 4 SW=>E 7 Metal Low-E Single Yes 0.63 0.25 N 39.8 ft2 1 ft 0 in 1 ft 4 in None None 5 NW=>S 8 Metal Low-E Single Yes 0.65 0.21 N 40.0 ft2 8 ft 0 in 1 ft 4 in None None 6 NE=>W 13 Metal Low-E Single Yes 0.63 0.25 N 16.2 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 I GARAGE I # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 806 ft2 806 ft2 26 ft 8 ft 11 INFILTRATION 9 i # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1636.1 89.82 168.92 .2598 i 7 I i f i I ' i I 4/16/2018 9:09 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 � i FORM R405-2017 HEATING SYSTEM I # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 i HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetP4 Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None I it SOLAR HOT WATER SYSTEM I FSEC Collector Storage Cert # Company Name System Model# Collector Model# it Area Volume FEF None None ftz I DUCTS ----Supply— --Return— Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 225 ftZ Attic 65 ftZ Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling Jan Feb Mar Apr May Jun X Jul X Aug X S p Oct Nov Dec Heating Jan Feb Mar Apr JM ay X Jun Jul Aug S 11 ep Oct Nov Dec Venting Jan Feb Mar Apr May Jun Jul Aug Sep �X�Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 9 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 I d I j 4/16/2018 9:09 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software, Page 5 of 5 2017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA . I Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST.LUCIE COUNTY City,State,Zip: FT.PIERCE, FL, Permit Number I Owner: Jurisdiction: Design Location: FL,Fort Pierce i COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a,sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. s all be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal nvelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/doorjambs and framing,and and doors skylights and framing shall be sealed. ! Rim joists Rim joists shall include the air barrier. Rim joists shall tie insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor deckir l or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the tool of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts,penetrations Duct shafts, utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on Narrow cavities installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. l Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind l and waring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Concealed When required to be sealed,concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprol cover a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 4/16/2018 9:09 PM EnergyGal USA-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 i FORM R405-2017 C ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. THE WINDSOR, FT. PIERCE, FL�, 1. New construction or existing New(From Plans) 9. Wall Types f Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 1224.00 ftZ b. Frame-Wood,Adjacent R=11.0 208.00 ftZ 3. Number of units, if multiple family 1 c.N/A j R= ftZ 4. Number of Bedrooms 3 d.N/A R= ftZ 5. Is this a worst case? Yes 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=30.0 1753.00 ftz 6. Conditioned floor area(ftZ) 1753 b.N/A R= ftZ 7. Windows** Description Area c•N/A R= ftZ a. U-Factor: Sgl,U=0.63 111.36 ftZ 11.Ducts R ftZ a.Sup:Attic,Ret:Attic,AH:Attic 6 225 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 40.00 ftZ SHGC: SHGC=0.21 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ftZ a.Central Unit 34.8 SEER:15.00 SHGC: { d. U-Factor: N/A ftZ 13.Heating systems kBtu/hr Efficiency SHGC: Area Weighted Average Overhang Depth: 2.850 ft. a. Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average SHGC: 0.239 8. Floor Types Insulation Area 14.Hot water systeIms Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1753.00 ftZ a.Electric b. N/A R= ftZ EF:0.97 c.N/A R= ftZ b. Conservation'features None 15.Credits Pstat i I certify that this home has complied with the Florida Energy Efficiency Code for Building 4SgE ST,gT Construction through the above energy saving features which will be installed (or exceeded) ti� 80 in this home before final inspection. Otherwise, a new EPL Display Card will be c&npleted ��v4`,,,;'''�' r•_ ,-�,�• + based on installed Code compliant features. Builder Signature: Date: Address of New HomA-� ,�City/FL Zip ,e1T,ce �►,coD W'E *Note: This is not a Building Energy Rating. If your Index is below 70, your hI me may qua lify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygiauge.com fo information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if,not DEFAULT. I I 4/16/2018 9:09 PM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1 I I