Loading...
HomeMy WebLinkAboutProduct Approval¢¢ BCIS Home Log In User Registration Hot Topics ` Submit Surcharge Slats & Facts Publications FBC Staff % BCIS Site Map Links Search 01Z"Product Approval USER: Public User Product Approval Menu > Product. or Application Search > Application List > Application Detail =..��Q a: ��FL # FL13998-R5 Application Type Revision { Code Version 2014 Application Status Approved t *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the C mmission if necessary. Comments Archived t�^ i l Product Manufacturer JELD-WEN Address/Phone/Email 3737 Lakeport Blvd I Klamath Falls, OR 97601 (800) 535-3936 fbcl@jeld-wen.com Authorized Signature Jason Kantola fbcl@jeld-wen.com Technical Representative JELD-WEN Corporate, Customer Service Address/Phone/Email 3737 Lakeport Blvd. Klamath Falls, OR 97601 I (800) 535-3936 customerserviceagents@jeld-wen.coRl Quality Assurance Representative JJ Address/Phone/Email I i i Category Windows Subcategory Awning i i Compliance Method Certification Mark or (Listing Certification Agency National Accreditation & Management Institute Validated By National Accreditation & Management Institute i Referenced Standard and Year (of Standard) Standard j Year TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By i I Product Approval Method Method 1 Option A "File 410p°r 13.125" O.C. 4" MAX. MAX. THRU FIN FROM CORNERS T a M v H S = MIDSPAN O O Z 3 Imo— WINDOW WIDTH (47.5" MAX.) — TYPICAL ELEVATION WITH FASTENER SPACING Installation Notes: 1. Seal flange/frame to substrate. 2. Use #10 PH or greater fastener though the nail fin with sufficient length to penetrate a minimum of 1 1/2" into the wood -framing. For 2X wood -frame substrate (min.-S:G.=-0.42). 3. Host structure (wood buck, masonry, steel) to be designed and anchored to properly transfer all loads to the structure. The host structure is the responsibility of the architect or engineer of record for the project of installation. This schedule addresses only the fasteners required to anchor the window to achieve the rated design pressure up to the size limitations noted. It is not intended as a guide to the installation process and does not address he sealing consideration that may arise in different wall conditions. For the complete installation procedure, see the instructions packaged with the window or go to www.jeld-wen.com/resources/installation. DISCLAIMER: This drawing and its contents are confidential and are not to be reproduced or copied in whole or in part or used or disclosed to others except as authorized by JELD-WEN Inc. 398 ``I-tit!c� �..! SHIM SPACE 22.0 mm 3,0 mm _� o.0 mm BITE mm DOW CORNING 995 FRAME SECTION (TYP) VERTICAL SECTION NOTE:-1 Eet"aen I.hllsn,Fanged%'-Openly _�-2X WOOD FRAME 11/2" MIN. EMBEDMENT NAIL FIN INSTALLATION MIN. DISTANCE FROM EDGE: — 3/4" 2X WOOD FRAME 1 1/2" MIN. EMBEDMENT 1/4" MAX SHIM SPACE JAMB SECTION (TYP) HORIZONTAL SECTION NOTE: Caulk beftnen Nailing Flange d Wood Opening. Max Frame I DP RATINGI IMPACT 47.5 x 31.5 1 +/-50 1 NO General Notes: 1. The product shown herein is designed, tested and manufactured to comply with the wind load criteria of the adopted International Building Code(IBC), the International Residential Code(IRC), the Florida - -Building Code(FBC-)-including-HVHZ--and the -industry requirement -for the -stated conditions.- -- 2, All glazing shall conform to ASTM E1300. 3. At minimum, glazing shall be 1/8" -1/8" annealed insulating glass. 4. Use structural or composite shims where required. 5. Installation methods can be interchanged within the same opening. __6.—An-impact- p[otecti.v_e system is required where_wind borne debris protection is mandated by local building code. 7. Maximum sizes are buck sizes and do not include fin or flange. �i, PROJECT ENGINEER: -- DATE: 12/06/2013 3737 Lakeport Blvd =LDrWN 0DRAWN SCALE: Klamath Falls, OR. 97601 BY: D. Vezo NTS Phone: (541) 882-3451 CHECKED BY: TITLE: wi 1. Kantola Ll:► Premium Atlantic Vinyl Awning Window APPROVED BY: <(r Nail Fin Installation (47.5 x 31.5 ) o� 1, .kbft 399 �. { IDENTIFIER No. CTL 210 3920- PLANT NAME AND LOCATION: -FBC CAD DWG. No.: REV: 00 SHEET 1 OF 4 4" MAX. 13.125" O.C. MAX. FROM THRU FRAME CORNERS Q N M H x C9 W x o O MIDSPAN z j3 J— I~ WINDOW WIDTH (47.5" MAX. TYPICAL ELEVATION WITH FASTENER SPACING M.DISTANCE 1 1/2" MIN. EMBEDMEN mm 9 mm MIN. DISTANCE GLASS BITE FROM EDGE: - LL 12.7 mm 3/4" DOW CORNING 995 FRAME SECTION (TYP) VERTICAL SECTION IN. DISTANCE FROM EDGE: 3/4' THROUGH FRAME INSTALLATION JAMB SECTION (TYP) HORIZONTAL SECTION Max Frame I DP RATING IMPACT 47.5 x 31.5 1 +/-50 1 NO Installation Notes: General Notes: 1. Seal flange/frame to substrate. 1. The product shown herein is designed, tested and manufactured to comply with the wind load criteria -2. Use #10 PH or greater fastener though the frame with sufficient length to penetrate a minimum of 1 1/2" of the adopted International Building Code(IBC), the International Residential Code(IRC), the Florida into the wood framing. Far 2X wood frame substrate (min. S.G. = 0.42). - --- - - Building Code(FBCJ including HVHZ and the industry requirement for the -stated conditions.--- - -- 3. Host structure (wood buck, masonry, steel) to be designed and anchored to properly transfer all loads 2. All glazing shall conform to ASTM E1300. to the structure. The host structure is the responsibility of the architect or engineer of record for the 3. At minimum, glazing shall be 1/8" -1/8" annealed insulating glass. project of installation. 4. Use structural or composite shims where required. 5. Installation methods can be interchanged within the same opening. - - -- - --- — 6--- An -impact -protective -system is -required -where -wind borne debris -protection is mandated by local This schedule addresses only the fasteners required to anchor the building code. window to achieve the rated design pressure up to the size limitations ���1ji � t 111�.10 7, Maximum sizes are buck sizes and do not include fin or flange. noted. It is not intended as a guide to the installation process and does �.� PROJECT ENGINEER: not address he sealing consideration that may arise in different wall ��� �'t' �.••'•� •rF �O -- D VY: B ezo conditions. For the complete installation procedure, see the instructions � packaged with the window or go to www.jeld-wen.com/resourceslinstallation, 7 .+ .: s+ * CHECKED BY:J. Kantola DISCLAIMER:This APPROVED BY: drawing and its contents are confidential and are not to be reproduced or copied in whole or in part or used or disclosed to others except as authorized b JELD-WEN Inc. P Y !i .; o. sea ssa Xenia � � IDENTIFIER No. DATE: 3737 Lakeport Blvd 12/06/2013 SCALE: I JMDAWENI(lamath Falls, OR. 97601 NTS I Phone: (541) 882-3451 Premium Atlantic Vinyl Awning Window Through Frame Installation (47.5" x 31.5") 00 1 2 OF 4 4" MAX. 13.125" O.C. MAX. FROM THRU FRAME CORNERS X 400/5 o N M v H C9 = 3 O O MIDSPAN z 13VL ��— WINDOW WIDTH (47.5" MAX. TYPICAL ELEVATION WITH FASTENER SPACING MIN, DISTANCE FROM EDGE: 2 1/2" 0 d .d 3 •• 11/4" MIN. EMBEDMENT d BLOCK 1/4" MAX SHIM SPACE 22.0 mm 3.0 mm 3.0 mm BITE mm V — DOW CORNING _GLAZING DETAIL 995 FRAME SECTION (TYP) VERTICAL SECTION — I I 1/4" MAX L(� SHIM SPACE a 11/4 MIN. L EMBEDMENT MASOBLOGKNRY ' Y • Q • MTN. DISTANCE FROM EDGE: 2 1/2" MASONRY INSTALLATION 11/4" MIN. EMBEDMENT 2/4" MAX MIN. DISTANCE Q 3Uvi-7 SHIM SPACE FROM EDGE: M1I21/2° IN2 BLOCK JAMB SECTION (TYP) HORIZONTAL SECTION Max Frame DP RATING IMPACT 47.5 x 31.5 +/-50 NO Installation Notes: General Notes: 1. Seal flange/frame to substrate. 1. The product shown herein is designed, tested and manufactured to comply with the wind load criteria 2. Use 3116" Tapcon or equivalent fasteners through frame with sufficient length to penetrate a minimum of the adopted International Building Code(IBC), the International Residential Code(IRC), the Florida of 1 1/4" into concrete or masonry at each location with a 2112" min from edge distance. For concrete — —Building Code(FBC)-including-HVHZ-and the -industry requirement for the -stated conditions-. — (min. fc = 3000psi) or masonry substrate (CMU shall adhere to ASTM C90). 2. All glazing shall conform to ASTM E1300. 3. Host structure (wood buck, masonry, steel) to be designed and anchored to properly transfer all loads 3. At minimum, glazing shall be 1/8" -1/8" annealed insulating glass. to the structure. The host structure is the responsibility of the architect or engineer of record for the 4. Use structural or composite shims where required. project of installation. 5. Installation methods can be interchanged within the same opening. - " - - - ` - - - - -- - - - - - -- - -- - - - - -- --6 --An impact protective system is required where wind borne debris rotection is mandated by local This schedule addresses only the fasteners required to anchor the t �. t +►.l ���i building code. 7. Maximum sizes are buck sizes and do not include fin or flange. window to achieve the rated design pressure up to the size limitations `��1� noted. It is not intended as a guide to the installation process and does not address he sealing consideration that may arise in different wall � .•�•� " ✓r Q' .• �i PROJECr ENGINEER: DATE: -- 12/06/2013 Lakeport Blvd conditions. For the complete installation procedure, see the instructions �� .. \ 'A : � � \, .. DRAWN BY: SCALE: th F ALDVEN Klamath Falls, OR. 97601 with the window or o to packaged /i ; O �. D. Vezo NTS Phone: (541) 882-3451 www.jeld-wen.com/resources/installation. • ` .:� = * * _ CHECKED BY: TITLE: J. Kantola DISCLAIMER: " APPROVED BY: Premium Atlantic Vinyl Awning Window Masonry Installation 31.5 This drawing and its contents are confidential and are not to be reproduced or copied in whole or in part or used or disclosed to others �e �. D'P'' �: p 7 P OzECr D : (47.5 x ) !i �� 6mgI 398.L� 338 IDENTIFIER except as authorized by JELD-WEN Inc. . Pln - No. PLANT NAME AND LOCATION: NCTL-210-3920- -FBC CAD DWG. No.: REV: SHEET �0 3 OF 4 4" MAX. 13.125" O.C. MAX. FROM THRU FRAME CORNERS N M v f- 2 = MIDSPAN o o C3 3 WINDOW WIDTH (47.5" MAX. TYPICAL ELEVATION WITH FASTENER SPACING NO. embedment of three threads Min. embedment of three threads Post frame Installation Notes: 1. Seal flange/frame to substrate. 2. For anchoring into metal framing use #10 TEK Self Tapping screws with sufficient length to achieve a minimum embedment of three threads past the frame thickness. -St -eel substrate min.-18ga., fy — 33 ksi 3. Host structure (wood buck, masonry, steel) to be designed and anchored to properly transfer all loads to the structure. The host structure is the responsibility of the architect or engineer of record for the project of installation. Digitally signed by Hermes F. Norero, P.E. Reason: I am approving this document - -- - - - - -- - _ Date: 2013:12.15-20:02:20 05'00'- - - - This schedule addresses only the fasteners required to anchor the ti;t i 1 it i window to achieve the rated design pressure up to the size limitations - noted. It is not intended as a guide to the installation process and does not address he sealing consideration that may arise in different wall Q' .•'" conditions. For the complete installation procedure, see the instructions packaged with the window or go to 7 www.jeld-wen.com/resources/installation. DISCLAIMER: T T This drawing and its contents are confidential and are not to be reproduced or copied in whole or in part or used or disclosed to others.�+ i: • ,. except as authorized by JELD-WEN Inc. 398 Xenia �1/4" MAX SHIM SPACE 22.0 mm 3.0 mm —_ 3.0 mm FRAME SECTION (TYP) VERTICAL SECTION IB gauge min Steel Stud MIN. DISTANCE _[ FROM EDGE: 112" Min. embedment —' SITE of three threads mm post frame STEEL INSTALLATION 1/4" MAX SHIM SPACE JAMB SECTION (TYP) HORIZONTAL SECTION Max Frame N RATING IMPACT 47.5 x 31.5 +/-50 1 NO General Notes: 1. The product shown herein is designed, tested and manufactured to comply with the wind load criteria of the adopted International Building Code(IBC), the International Residential Code(IRC), the Florida Building COde(FBC)-including-HVHZ and the -industry -requirement for the -stated conditions.- --- 2. All glazing shall conform to ASTM E1300. 3. At minimum, glazing shall be 1/8" -1/8" annealed insulating glass. 4. Use structural or composite shims where required. 5. Installation methods can be interchanged within the same opening. -6. An -impact protective -system -is -required -where -wind borne -debris -protection is -mandated by -local building code. 7. Maximum sizes are buck sizes and do not include fin or flange. PROJECT ENGINEER: rO DRAWN BY: D. Vezo "^CHECKED BY: J. Kantola >r APPROVED BY: �L VNUP�D�7�oG 338 DATE' 3737 Lakeport Blvd 12/06/2013 SCALE:JMD*TN Klamath Falls, OR. 97601 NTS Phone: (541) 882-3451 Premium Atlantic Vinyl Awning Window Steel Installation (47.5" x 31.5") AND LOCATION: I CAD DWG. No.: I REV. 001 SHEET 4 OF 4