DATE: 11/15/17 JOB ORDER#: 17-3744
i
CLIENT: All Area Roofing
i
ADDRESS: 3921 S. US Highway 1 Fort Pierce,Floridal34982
PROJECT: Fort Pierce Inlet State Park Sunlast Metal Roof Panels
ADDRESS: 2405 Oak Drive Fort Pierce Florida)
2014 FBC/ASCE 7-10 DESIGN PRESSURE CALCULATIONS
Proiect Information:
Mean Height=Max. 15' Exposure: D Basic/Ultimate Wind Speed: Vuit=170 mph
Length= 5F Category: H Nominal Wind Speed: Vasd=Vuit*40.6
y
Width= 29' Slope: 4/12= 18' (asd=allowable strength design)
Parapet Wall: N/A Residential KZ= 1.03, Kzt= 1.01�Kd=0.85
I
Design Calculations:
Velocity Pressure: q=0.00256*KZKztKdV2
Velocity Pressure („lt): q=0.00256(1.03)(1.0)(0.85)(170)2] =64.77 psf i
Velocity Pressure (ad): q=0.00256(1.03)(1.0)(0.85)(170*40.6)21 = 38.66 psf
Width of Pressure Coefficient: 0.1(29') = 2.9'
0.4(15') = 6.0' 1 use: 3'0"
Effective Wind Area: <1 W
External Pressure Coefficient: Internal Pressure Coefficient:
1) GCP1 = -0.9 1) GCPi = 0.18
2) GCP2 = -1.7
3) GCP3 = -2.6 '
i
! I
Design Pressures Based on Vasd:
1) Field P1 = 38.66*[(-0.9)—(0.18-)] =-42.0 psf
2) Perimeter P2 = 38.66*[(-1.7)—(0.18)] =-73.1 psf
3) Corners P3 = 38.66*[(-2.6)—(0.18;)] =-108.0 psf
I
�i Q �y
Quality�� A /✓lswerance
I'
I
I
(� Page 2,11/15/17,Job Order#1 - 44 a
• All Area Roofing FLO A
Fort Pierce Inlet State Park-Sunlast Metal Roof Panels
2405 Oak Drive;Fort Pierce,FL:
{
Attachment Requirements:
Based on the requirements of Florida Product Approval # 21423.2 with maximum design
pressures of -76.75psf and -108.5psf; the following are our recommended fastening
patterns to attach the Sunlast Metal 1.5" Clipless Snap Lock Aluminum Roof Panels (15"-
19" widths) to the 15/32" 4-Ply CDX Plywood decking with # 10 Pancake Corrosion
Resistant fasteners with 1/4" minimum penetration through the plywood and seal seams
with Bostik 70-05A 3/8" bead along both sides of clipless seams, full length of panel:
0
Area Field & Perimeter Corners
I' I
Maximum Total Uplift Design Pressure -76.75psIf -108.5psf
i
Fastener Spacing at Seams 3" O.C. , 6" O.C.
I
Notes: Corners and perimeter (edge, hip, & ridge) area dimension shall not be less
than a = 3'0" (Zone 2: Perimeter (including along ridges) is a 3'0" wide
strip, Zone 3: Corners are 3'0" x 31011)
Contractor to verify that the fastening patterns meet manufacturer's
requirements for issuance of a warranty(as applicable).
All work shall be in compliance with the local building code product control
notice of acceptance and manufacturer specifications and Florida Building
Code 2014 Edition.
i
i
Wind load calculations based on ASCE 7-10, 2014 FBC, land information
provided by client. Client is responsible for verifying existing
p conditions as it
pertains to the above provided product approval.
All work shall be inspected by our field, engineer ; (or authorized
representative) or a building department inspector to verify compliance with
specifications. \`®��®�1ir ®�����®
Sincerely ���
® ,
s • �� 1® �-
Vj-
7t
e
Mark A. Nl; r'F 'q„XI E. : 4i
Florida Eng"I" RM,
Florida Reg.Ned/ L ®�`°
Certificate of Authoi�i�a�t�� � o. 6923