S
FL# FL21423-RO
.u.— Application Type New
Code Version 2014 1 i
Application Status Approved
I
Comments
I I
Archived ❑
I
Product Manufacturer Sunlast Metal i
Address/Phone/Email 2120 SW Poma Drive
Palm City,FL 34990
(772)223-4055, I
fivalidatlon@ya6o.o.com
Authorized Signature Terry Kapron j
'flval idation@yah=com
Technical Representative
i
Address/Phone/Email
I
Quality Assurance Representative,
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
I
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report-Hardcopy Received
I
I
Florida Engineer or Architect Name who developed ''JAMES BIAGI I f
the Evaluation Report
Florida License PE737467
Quality Assurance Entity Keystone Certifications,-Inc.
Quality Assurance Contract Expiration Date 03/02/2026
Validated By Locke Bowden
rJ� Validation Checklist-Hardcopy Received
Certificate.of.Independence FL21423 RO COI James Biagi P E Certificate of Independence 6df
I
Referenced Standard and Year(of Standard) Standard Year
TAS 100 1995
TAS 125 2063
Equivalence,of Product Standards, j
Certified By
I l
Sections from the Code
I !
I
Product Approval.Method Method 1 Option D
i
I
i
I
Date Submitted 12/16/2016
Date Validated 12/16/2016
i
Date Pending FBC Approval 12/19/2016
Date Approved 02/07/2017
Date Revised 19/21/2017 i
Summary of Products
FL# Model,Number or Name Description
I
21423.1 JAX BEACH SERIES CLIPLESS SNAP 1.5 24GA 35-19"WIDTHS OVERj15/32"4-PLY CDX
LOCK PLYWOOD
Limits of Use Installation instructions
Approved for use in HVHZ:Yes FL21423 RO ,I JAX BEACH Series-CLIPLESS SNAPLOCK
Approved for use outside HVHZ:Yes' 24GA-REPORT ss-FINAL.odf I
Impact Resistant:N/A Verified By:JAMES BIAGI 37467
Design Pressure:+N/A/-161PSF Created by Independent Third Party:Yes
Other:-161PSF@6"O.C.,-97.25PSF@3"0.C.INSTALL PER Evaluation Reports
MANUFACTURER'S DETAILS AND IN COMPLIANCE WITH FBC FL21423 RO IAE JAX BEACH Series-CLIPLESS SNAPLOCK
2014. 24GA-REPORT ss-FINAL.odf
Created by Independent Third Party:Yes
i
21423.2 �JAXCH SERIES CLIPLESS SNAP 1.5 ALUMINUM.032 SL 15-19"WIDTHS OVER 4-PLY CDX
LUM PLYWOOD
Limits of Use Installation Instructions I
Approved for use in HVHZ:Yes FL21423 RO III JAX BEACH Series-CLIPLESS SNAPLOCK
Approved for use outside HVHZ:Yes. ALUM-REPORT ss-FINALodF.odf,
Impact Resistant:N/A Verified By:JAMES BIAGI 37467
Design Pressure:+N/A/--108.5 Created:by Independent Third Party:Yes
Other:-108.5psf@3"O.C.,-76.75@6"O.C.INSTALL PER Evaluation Reports
MANUFACTURER'S DETAILS AND IN COMPLIANCE WITH FBC FL21423 RO IAE JAX BEACH Series-CLIPLESS SNAPLOCK
2014. ALUM-REPORT ss-FINALodf.Dd6
Created by Independent Third Party:Yes
i I
21423.3 MIAMI SERIES SNAP LOCK 1.75 24GA 14-18 WIDTHS OVER 15/32"APA PLYWOOD
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL21423 RO II MIAMI SERIES 24GA SNAP LOCK 1,75 ss-
Approved for use outside HVHZ:Yes FINAL,odf
Impact Resistant:N/A Verified By:JAMES BIAGI 37467
Design Pressure:+N/A/-156.75 Created by IpdependentThird,Party:Yes
Other:-114.25PSF @16"O.C.,-156.75PSF @8"O.C. Evaluation Reports
INSTALL PER MANUFACTURER'S DETAILS AND IN FL21423 Rol
AE MIAMI SERIES 24GA SNAP LOCK 1.75 ss- j
COMPLIANCE WITH FBC 2014. Created ated by II dependent ThirdjParty:Yes +
i
i
21423.4 MIAMI SERIES SNAP LOCK 1.75 .032 ALUMINUM 14-18 WIDTHS OVER 15/32"APA PLYWOOD i
ALUM
Limits of Use InstallationlInstructions
Approved for use in HVHZ:Yes. FL21423 RO II MIAMI SERIES SNAP LOCK 1.75 ALUM ss-
Approved for use outside HVHZ:Yes FINAL.odF
Impact Resistant:N/A 'Verified By:(JAMES BIAGI 37467
Design Pressure:+N/A/-114.25 Created by Independent Third Party;Yes
Other:-110.5PSF@12"0.C.-114.25PSF@6"O.C.INSTALL Evaluation Reports
PER MANUFACTURER'S DETAILS AND IN COMPLIANCE WITH FL21423 RO AE MIAMI SERIES SNAP LOCK 1.75 ALUM ss-
FBC 2014. FINAL.odf
Created by Independent Third Party:Yes
21423.5 PALM BEACH SERIES MECHANICAL 24GA 12-20"WIDTHS OVER 15/32"4-PLY COX PLYWOOD
LOCK 1.5
Limits of Use Installation,Instructions
Approved for use in HVHZ:Yes FL21423 RO II PALM BEACHISERIES 1.5 MECHANICAL
Approved for use outside HVHZ:Yes LOCK-ss-Final-l.odf
Impact Resistant:N/A Verified By:IJAMES BIAGI 37467
Design Pressure:+N/A/-112PSF Created.by Independent Third Party:Yes
Other:Method 1-90 DEGREE SEAM-93.5psf 24"O.C. Evaluation Reports I
Method 2-90 DEGREE SEAM-101PSF 6"O.C.Method 3-180 FL21423 RO AE PALM BEACH SERIES 1.5 MECHANICAL
DEGREE SEAM-112psf 6"O.C.Fasteners per Cllp:2 INSTALL LOCK-ss-Fin'Si-l.odf
PER MANUFACTURER'S INSTALL DETAILS IN COMPLIANCE. Created by Independent Third Party:Yes
WITH FBC 2014
i
21423.6 PALM BEACH SERIES.MECHANICAL .032 ALUM 16 OR 20"WIDTHS OVER 15/32"4-PLY COX
LOCK 1.5 ALUM PLYWOOD I j
Limits of Use Installation Instructions
Approved for.use in HVHZ:Yes FL21423 RO II PALM BEACH MECHANICAL LOCK ALUM-
Approved for use outside HVHZ:Yes ss.Final.odf I i
Impact Resistant:N/A Verified'By:JAMES BIAGI 37467
I
I
i
Design Pressure:+N/A/--131PSF Created'by In dependent Third Party:Yes
Other:METHOD 1-90 DEGREE sEAM-63.5PSF 24"O.C. Evaluation Reports J
METHOD 2-90 DEGREE SEAM-86PSF 24"O:C.METHOD 3- FL21423 RO Ae PALM BEACH MECHANICAL LOCK ALUM-
131PSF 180 DEGREE SEAM-6"O.C.2 FASTENERS PER CLIP ss.Final.odf
INSTALL PER MANUFACTURER'S INSTALL DETAILS IN Created by Independent Third Party:Yes
COMPLIANCE WITH FBC 2014
i
21423.7 SERIES-,KEY WEST 5 V CRIMP 26GA 24".WIDTH 5/8"RIB OVER 15/32"APA PLYWOOD
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL21423 RO III SERIES Key WI st 5 V Crimp ss-FINAL ndf
Approved for.use outside HVHZ:Yes Verified By:]PMES BIAGI 37467
Impact Resistant:N/A Created by IgdependentThird Party:Yes
Design Pressure:+N/A/-189.25 Evaluation Reports
Other: 189:25PSF@8"O.C.,-78.5PSF@16"O.C.THRU FL21423 RO IAE SERIES Key West 5 V Crimp ss.-FINAL.pdf
FASTENED..INSTALL.PER MANUFACTURER'S INSTALL Created:by Irj dependent Third Party:Yes
DETAILS IN COMPLIANCE WITH FBC 2014
i
21423.8 SERIES-.STUART LINE NAIL 1.0,24GA NAIL STRIP/SNAP LOCK 16"COVERAGE WIDTH
STRIP/SNAP LOCK
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL21423 RO'II 1.0 SERIES-STUART LINE Nail Strip-Snap
Approved,for use outside HVHZ-Yes Lock-ss-Fnal:pdf 1
Impact Resistant:N/A Verified,By:JAMES BIAGI 37467
Design Pressure:+N/A/-136.75 Created by Independent Third Party:Yes
Other:-136.75PSF @ 6"O.C.,-84.25PSF @ 12"O.C. Evaluation eprts
INSTALL PER,MANUFACTURERS INSTALL DETAILS IN FL21423 RO1�AEo 1.0 SERIES-ISTUART LINE Nail Strip-Sna
- s-Fiha. df
Ipp
COMPLIANCE-WITH FBC 2014 Lock s Created-by Independent Third Party:Yes
flack Next
i
{
Contact Us::.2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 1
The State of Florida is an AA/EEO employer.Coovriaht 2007-2013 State a Florida.::Privacy(SItatement::Accessibility Statement::Rerund Statement
Under Florida law,emall.addresses are public records.If,you do not want your e-mail address;releasdd In response to.a publI-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by.traditlonal mall.If you have any,questl4ns,please contact 850.487:1395.-Pursuant to Section 455.275
(1),Florida Statutes,effective October 1;2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The
emalls provided may be used for official communication with the licensee.However email addresses are public record..!(you Ao not wish to supply a personal address,
please,provide the Department with an a all address which can;be made available to the.public.To determine If you are a licensee under Chapter 455,F.S.,please
click hem.
1
Product Approval Acceptsr
I
Credit Card
Safe
I
I
I I
a
I
I I
i
I
I
I
I i
I I I
i
I
I !
I 1
i I
I
45'.:uhlasf Metal
Value Engineered Metal Roofr g TM
FLORIDA-PRODUCT APPROVAL
I �
I
JAX BE
.SERIES 1.S C;LIF'LES.S: AP LO_ K �►LUI�/1�
-I5 1,9 : WIDTHS ROOF PANEL OVER;PLY,WO :O,
FLORIDA PRODUCT APPROVAL 0' 21423 2.=
Product Evaluation Report
I
1
I
1.5 CLIPLESS SNAP LOCK.032 ALUM Roof Panel over 15/32"Plywood
Florida Product Approval # 21423.2
Florida Building Code,2014 Per Rule 61G20- Method:1—f] j
i
Category:Roofing Subcategory:Metal-Roofing
Compliance Method:Rule 61620-3
HVHZ
Product Manufacturer: {
Sunlast Metal
'2120 SW Poma Drive
Palm City,Florida'34990
Engineer Evaluator
James Biagi,P.E.FL#37467 1
1915 NE.451h ST.4107
Fort Lauderdale,FL 33308
954.-776-8004
I
Validator..
Locke Bowden,P.E.,FL#49704
9450 Alysbury Place
Montgomery,AL 36117
Contents: j
Evaluation Report1-1U
Wt6
j ;Jam�l%;agf E.
FL#3746,k
i 'itr4!lli73i►►��
Page 1 of 3 {
I
I
I
I I
` ) I
Compliance Statement: The product as described in this report has demonstrated_compliance with the
Florida Building Code-2014,Sections 1504.3.2 1507A.3 1518.9 '1523.6.5.2.4
Product Description: 1.5"Clipless_Snap Lock Roof Panel,'032�ALUM 15'1' Widths,Roof panels
Panel fastened'into 15/32"4-PLY CDX Plywood decking.Non-structural Application.
Material: .032 ALUM Corrosion Resistance:Material shall comply with Florida Building Code 2010,5ecti"on 1507.4.3
I
Panel Dimensions: Panel Widths: 15"-19"
Fastener:_ #10 Pancake. Corrosion Resistant per Florida Building Code 2014 Section 15b6.7
Y"minimum penetration through plywood
Seam sealant: Bostik 70-05A.3/8"bead along both sides of clipless seams;full length of panel '
Corrosion Resistance:Per Florida Building Code 2014,.Section 1506.6, 1507.4.4
15/32"4-ply CDX Rated plywood.Plywood supports at maximum 24'O.C. Design of plywood and plywb od supports
are outsidethe scope of this evaluation. Must be designed in accordance w/Florida Building Code 2014.
I
Design Uplift.Pressures: Uplift Design Pressure:with Safety Factor of 2
-108.5 PSF @ 3"O.C. FASTENER SPACING
46.75PSF @ 6"O.C.FASTENER SPACING
Reference:TAS 125-03 Test-Report#D6207-01-450-18 TAS 100-95 Report#D4563-011-450-18 by Architectural
Testing,Inc.an Intertek.Company,West-Palm Beach Facility. Miami-Dade County Notification No.ATIWPB.16031
I
1
Code Compliance: The product described herein demonstrated compliance with The Florida Building Code(FBC)'2014 Section
1504.3.2. The product evaluation is limited to compliance with the structural wind load requirements of the FBC 2014,as relates to
Rule61G20-3. 1
I
I
Minimum Slope Range Minimum Slope per Florida Building Code'2014,and in accordance with Manufacturers recommendations.
d
Installation:Install per manufacturer's recommended details.
I �
Underlayment:Per Manufacturer'-s installation guidelines per Florida Building-code 2014 {
Roof Panel Fire Classification:No classification.
Shear Diaphragm:values are outside the scope of this report.
Design Procedure:Based on the dimensions of the structure,applicable wind loads are determined using Chapter 16 of the Florida
Building Code 2014 for roof cladding wind loads.These component wind loads for roof cladding are compared to the allowable
pressure listed above.The design professional shall select the-applicable erection details to reference in drawings for correct
fastener attachment to his structure and analyze the panel fasteners for pullout and puIHover.SupportIframing.must be compliant
with Florida Building Code 2014 Chapter 22 for steel,Chapter 23 for wood and Chapter 116 for structural loading.
i
Certificate of Independence:James Biagi,P.E.does not.have nor will acquire financial interest in any company manufacturing or
distributing.products under this evaluation. James Biagi,P.E.is not owned or operatedl,or controlled by any company
manufacturing or distributing product under this report.
' I
i
I
Page 2 of 3
i l
C`unlast Met
al
Value Engineered Metal RoofngTm AX213EA 'CH SERIES(I",50LIPLESS SNP W100, KALUM
,
R*O 0 F;`-.'..PAN.EL.-`OV 6, T9!' WIDTH& ;RP,LYWOO.,.P,,, ,,.:
INSTALL DE . . ...,S
1.5." CLIPLESS
JAX IBEACH SERIES'
15"-19",Coverago
Flat WCrp ROW
(Oplional Stiffemrg Ribs Availatle)
I.
IL
All'
Test sample complies with these details.
Deviations are noted.
Report# D4563'.01-450-18
Date 07/15/14 Verified By: Alan Rule
Wood beck (45132" Min)
Integral Snap Lock
Seam Adhesive (Sealant)
Clip Relief(Recommended)
410 x I" Pancake-Head