EVALUATION REPORT �L: ECTl�
Boral Roofing Evaluation Report M35710.12AO-117
7575 Irvine Center Drive FL14317-116
Suite 100 Date of Issuance:12121/2010
Irvine,CA.92618 Revision 7:04/29/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for
use of the product under the Florida Building Code and Florida'Building Code,Residential Volume. The products described
herein have been evaluated for compliance with the 51h Edition(2014)Florida Building Code sections noted herein.
DESCRIPTION: Boral Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance' gency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)!changes, the referenced
Quality Assurance documentation changes,or provisions of the Code that relate do the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen,P.E.if the product changes or the
referenced Quality Assurance documentation changes. Trinity(ERD requires a c6plete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle,
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinityiERD Evaluated" may be displayed in
advertising literature, If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the Job site at the request of the Building Officia,l.
This Evaluation Report consists of pages 1 through 6,
Prepared by: JI,rrMY"
AktA 3.
P.E. S .r =;.' The facsimltesoalappeaiing was authorized by Robert Nteminen,
Robert l.M.Nieminen
�'°�*�uaM t' 'FZ.on04/2Bi2015.Thlsldoes not serve as an elactroBicaw signed
Florida Registration No.59166,Florida OCAANE1983 """t'r" doarmertt.Slimed,sealed hardcoples have been transmitted tothe
PraductApproval Admrnist W and to the named client
CUMFICATION of INDEPENDENCE:
1. Trinity I ERD does not have, nor does It intend to acquire or will it acquire, a financial Interest in any company manufacturing or
distributing products it evaluates.
2. Trinity]ERD is not owned,operated or controlled by any company manufacturing or distributing products It evaluates.
3. Robek Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen,P.E.aye,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose. THESE PLANS AND ALL PROPOSED WORK
CONCEALED FASTENERS ON AftAdAt'i�j iS ARE SUBJECT TO ANY CORRECTIONS
ARE THE RESPONS19ILlTV 0�f�� REQUIRED BYIFIELD INSPECTORS THAT
MAY BE NECESSARY IN O
CONTRACTOR OP AEJbb i COMPLY WITH-A L RDER TOAPPLICABLE CODES.
I'
I r
Tile, Copy
I'
ti Ma
TNNITYIERD
ROOFING COMPONENT EVALUATION:
1, SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Boral Roof Underiayments, as marketed by Boral Roofing, have demonstrated compliance with the
following sections of the Florida Building Code through testing In accordance with the following Standards, Compliance is subject
to the Installation Requirements arid Limitations/Conditions of Use setforth herein.
2. STANDARDS:
Section PropeM Standard Year
1504.31 Wind Uplift FM 4474 2004
1507.2.4,1507.2.8,1507.2.9.2,1507.4.5.1, Physical Properties ASTM D1970 2009
1507,4,5.2,1507,5.3,1507.5.3.2,1507,63,
1507,63.2,1507,7.3,1507.7.3.2
1507.33 Installation Practice FRSA/TRI April 2012(04-12) 2012
1522.65.2.1 Physical Properties, TAS 103 1995
3. REFERENCES:
Entity Examination Reference Date
ERD(TST6049) Wind Uplift T6460,06.07-Ri 10/09/2007
FRO(TST6049) Physical Properties T33190.08,10 08/06/2010
FRO(TST 6049) Physical Properties M33180.08.10 10/09/2010
ERD(TST6049) Wind Uplift T37610,07,11 07/29/2D11
FRO(TST 6049) Physical Properties 340380.08.12 08/28/2012
ERD(TST 6049) Physical Properties C41420.09,12.2 09/11/2012
FRO(TST 6049) Physical Properties 941940.09.12 09/13/2012
FRO(TST 6045) Physical Properties 847390.07,14.1 07/31/2014
FRO(TST 6049) Physical Properties B47390,09.14 09/04/2014
PRi(T5T5878) Physical Properties NEI-006.02-Di 04/01/2002
PRi(TST 5878) Physical Properties NEI.034-02.02 03/23/2006
PRI(TST5878) Physical Properties NEI-045-02-01 08/08/2D07
PRI(TST5878) Physical Properties ' NEI-053-02-01 05/01/2008
PRI(TST5878) Physical Properties NEI-070-02-01 08/12/2009
PRI(TST5878) Physical Properties NEI-031-02-01REV 10.27.10 10/27/2010
PRi(TST5878) Physical Properties NFI.029.02.01REV:11.03.10 12/03/2010
PRI(TST5878) Physical Properties NEI.046-02-OIREV 12/17/2010
PRI(T5T5878) Physical Properties NEI-034-02-02/MLT-M-02-01 01/29/2013
PRI(TST5878) Wind Uplift BORR-001.02-01 03/17/2015
UL,I.I.C.(QUA 9625) Quality Assurance Service Confirmation,R14610 Exp.12/10/2017
UL,LLC.(QUA 9625) Quality Assurance Cross-ListingConfiirmatiion,R16744 09/04/2013
UL,I.I.C.(QUA 9625) Quality Assurance Service Confirmation,R16744 Exp.10/13/201.7
4. PRODUCT DESCRIPTION:
4.1 Self-AdheringUnderlayments:
4.1.1 Boral TIIeSeai® Se Is a nominal 50-roil thick, polyester-surfaced, self-adhering SBS modified bitumen roof
underlayment-
4a.2 Boral TlIeSeaP HT is a nominal 60-mli thick, polyester-surfaced, self-adhering SBS modified bitumen roof
underlayment.
4.1.3 GatorSeal®is a nominal 5-5-mil thick,granular-surfaced,fiberglass reinforced,self-adhering SBS modified bitumen roof
underlayment.
4,1.4 StormSentry"'is a nominal 120-mil thick,mineral-surfaced,fiberglass reinforced,self-adhering SBS modified bitumen
roof underlayment.
4.1.5 Citadel®Plus is a nominal 48-mil thick, fabric-surfaced,fiberglass reinforced, self-adhering SBS modified bitumen
roofing underlayment for use as a base-layer in two-ply underlayment systems.
Extemor Research and Design;I.I.C. EValuation Report M35710,12,10-R7
Gerdi/ira`te of Autha&ation 0503 PL14317-116
Revision 7:04/29/2015
Page 2 of 6
i
I'
i
y IIIERD
S. LIMITATIONS:
$.1 This Is a building code evaluation. Neither Trinity)ERD nor Robert Nieminen, P.E. are,in any way,the Designer of
Record for any project on which this Evaluation Report,or previous versions thereof,•is/was used for permitting or
design guidance unless retained specifcallyfor that purpose.
5.2 This Evaluation Report is not for use In the HVHZ.
5.3 Fire Classification is not part of this Laboratory Report,refer to currentlApproved Roofing Materials Directory for fire
ratings of this product.
5.4 Boral Roof Underlayments may be used with any prepared roof cover,where the product is specifically referenced
within FBC approval documents. If not listed,a request maybe made to,t:he AHJ for approval based on this evaluation
combined with supporting data forthe prepared roof covering. I.
5.5 Allowable roof covers applied atop Boral Roof Underlayments are follows. Table i pertains to use of each listed
underlayment by-itself beneath the stated roof covers. Refer to the in tallatlon Instructions and Table 2 for two-ply
underlayment options. ;I
rt>:+^:'t.: :,°'d„6°Nr>.mt.jo'L,5:.Sw'_•till.!^. 1...� ..�e'T1'?,.'+`•;•Y>P'^.:,Mir' r�iC �'¢G' YV"�'ii�YA'•i.5 s��rr._ r•,•;_¢fY4rt Yr�. r;kk::u ti,�,c 1�.�
:u` `z= >R3 ,,:J,'r� T.' , .:p: �5;;yt >G.yYi. rik I KC y Yunti,, ✓_• �rt "r, Ya
s.�exr•> . G..Gt...au=,.. j,.:7'... ....:L. .,+,:• ` �tY'•!` .a> r�.a�'I':'••:3:a. ,.5!4?.�! s.�,? a:<_'L.,"°s4a1..Yd.�r..
Undertayment Asphalt Nail-On Tire FDam•On Tlie Metal ,2 Wood Shakes Slate
Shingles &Shinres
Saral'nleSeal50m Yes (battYsoniy) No Yes Yes Yes
Yes
Borai,rilesear Yes Yes Yes Yes Yes
(see 5S.ir
GatorSeal Yes Yes No No Yes Yes
(batt¢rs only)
St.-Sentry Yes Yes l No No Yes Yes
5.5.1 "Foam-On Tile"is limited to use of the following unless tensile adhesion/long term aging data from an accredited
testing laboratory is provided,
Underlayment TileAdhesives
3M'"2-Component Foam Roof T(Ie Adhesive AH-160(FL6332)
Boral TileSeal"r 3MTM Roof Tile Adhesive RTA-1(FL6276) '
Dow TILE BOND"Roof Tile Adhelsve(FL717) l
Convenience Products'Touch'n Seal StormBond Roof Tile Adhesive(FU,450fi)
5.6 Allowable Substrates:
5.6.1 Direct-Bgnd to Deck:
Citadel Plus,Boral TileSeal 50n Boral TileSeai"T StormSentry or GatorSeai:
D Plywood(unprlmed or primed with ASTM D41 primer).
Boral TlieSeal"T; �1
OSB primed with ASTM D41 primer.
5.6.2 Wind Resistance of Underlayment Systems in Foam-On Tile AooBcations: FRSA/TRi;Aprii 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam-on tile syste s,where the underlayment
forms part of the load-path. The following wind uplift iimitations'apply to underlayment systems that are not
addressed in FRSA/TRI April 2012(04-12)and are used)ri foam-on tile;appllcatlons. Maximum Design Pressure is the
result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing pressure
divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied).Refer to FRSA/TRI April 2012(04-
12),Appendix A,Table 1A or FBC 1609 for determination of design wind loads.
5.6.2.1 Maximum Design Pressure=-45 osf.
Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of AHJ.
Primer. (Optional)ASTM D41
Base Layer. (Optional)Citadel Pius,self-adhered
Underlayment: Boral TileSed",self-adhered
Exterior Research and Design,LLC. Evaluation Report M3S710.12.10-R7
Certiffcote of Authorizarfon#9SO3 FL14317-R6
Revision 7:04/29/2015
Page 3 of 6
I'
i
i
5.6,2.2 Maximum Design Pressure=-67.5 psf, TRINHWIERD
Deck: Min,15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optional)ASTM D41
Underla ment: Boral Tlle5eal"r self-adhered and back-mile within "Y d t n the selvedge-edge side laps using 12 ga.x 1Y, ring shank
nails through primed 32 ga.,1.5/8"diameter tin caps spaced 12-inch o.c.
5.6.3 Bond to Base Laver Underlayment:
Citadel Plus,Boral TileSeal 50HT,Boras TIIeSealHT or GatorSeal:
ASTM D226,Type 11 felt;Citadel Plus.
StormSentry:
ASTM D226,Type it felt;Citadel Plus,
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under foam-on tile systems, base layer shall be attached per minimum
requirements of FRSA/TRI April 2012(04-12).
5.6.4 Bond to Other Substrate Types:
Citadel Plus,floral TifeSeaf 5014T,Boral TileSealHT,StormSentry or GatorSeal
➢ ASTM D41 primed metal(e.g.,flashing metal,valley metal,etc).
Boral TileSealHT:
➢ Huber Tip Deck(unprimed or primed with ASTM D41 primer);Dens Deck Prime,
Note:For installation under mechanically attached prepared roof coverings,insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval.
5.7 Exposure Limitations:
5.7.1 GatorSeal shall not be left exposed for longer than 30-days after Installation,prior to placement of final roof cover.
5.7.2 StormSentry shall not be left exposed for longer than 90-days after installation,prior to placement of final roof cover.
5.7.3 Alcazar,Boral TileSeal 50HT and Boral TileSealHT shall not be left exposed for longer than 180-days after installation,
prior to placement of final roof cover.
5.7.4 Citadel Plus,for use as a base-layer in a two-ply underlayment system,shall not be left exposed for longer than 180-
days after Installation,prior to placement of subsequent underlayment layer.
6. INSTAi.1ATION:
6.1 Boral Roof 1lnderlayments shall be installed in accordance with Bore] Roofing published installation instructions
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
612 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application,and prime the substrate(if applicable).
6.3 Install self-adhering underlayment when ambient and surface temperatures are minimum 407 and rising.
6.4 Citadel Mus:
6.4.1 Citadel Plus is limited to use as a base or mid-lageT in multi-ply underlayment systems beneath Boral TileSeal 50HT
Boral TIIeSeal HT,GatorSeal or StormSentry,
6.4.2 Slope limitations are those associated with the top-layer underlayment.
6.4.3 Direct to heck:
Cut the membrane into manageable lengths, typically 10 to 12 ft. Afign the membrane parallel to the roof edge,
extending over by X-inch.Fold the membrane away from the edge onto itself. Remove the release sheet.Place the
membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place, Roll into place with a
weighted roller.
Boras recommends fastening of the top edge of the sheet to the deck with roofing nails, nails&tin-tags or 1-inch
diameter plastic or steel cap nails spaced 24-inch o.c.for slopes below 7a2 and 12-Inch o.c,for slopes 7:12 and
greater. Overlap successive courses minimum 2 inches(horizontai lap)and minimum 4"end(vertical)laps.
Install final underlayment layer atop Citadel Plus per 'direct-to-deck' Instructions for Boral TileSeal 50HT, Boral
TilesealHT GatorSeal or StormSentry.
Exterior Research and Design,I.I.C. Evaluation Report M35710.12.10-R7
Cortifktrte ofAuthodiarion N9503 F614317-R6
Revision 7:04/29/201S
Page 4 of 6
�I it
! IMINITY Et\D
6.4.4 To Base Sheet:
Install ASTM D226,Type II felt in accordance with Code requirements or Install Citadel Plus in accordance with Boral
Roofing published Installation Instructions and Section 6.4.3 and when used as part of a multi-ply system.
Install Citadel Plus as a mid-ply in accordance with Boral Roofing published installation instructions and Section 6.4.3.
Install final underlayment layer atop Citadel Plus per `direct-to-deck instructions for T,Boral TileSeai 50" Boral
TileSeal"r,GatorSeal or Stormsentry.
66.5 Boral TileSeal Se-
6.5.1 install Boral TileSeai 50"T in compliance with manufacturer's published lInstallation instructions and the requirements
for ASTM D1970 underlayments in FBC Sections 1507 for the type of prepared roof covering to be installed.
6.5.2 Do not use Boral TlleSeal 50"r on roof pitches less than 2:12,
6.5.3 Non-Tile Applications,Direct to Deck:
Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge,
extending over by Y.-Inch.Fold the membrane away from the edge onto itself. Remove the release sheet.Place the
membrane with the exposed rubberized asphalt onto the deck, pressing firmly Into place. Roll Into place with a
weighted roller.
Boral recommends fastening of the black selvedge edge to the deck�..Wth roofing nails, nails &tin-tags or 1-inch
diameter plastic or steel cap naffs spaced 24-inch o.in for slopes below 7.22 and 124h1 ch o.c. for slopes 7:12 and
greater, Overlap successive courses the width of the black-selvedge area.minimum 3-Inch.
Seal under end(vertical)taps using approved mastic,or use Joined and'Folded Seam or inverted Sheet Seam method
detailed In Boral Roofing published installation instructions.
6.5.4 Non-Tile Applications,to Base Sheet:
install ASTM D226,Type 11 felt in accordance with Code requirements.
Install Borai TlleSeal 50"r in accordance with Boral Roofing published Installation instructions and Section 6.5.3,except
end(vertical)laps,described below.
Apply SBS Mastic under all end (vertical) laps or any other laps wheree the self-adhering bituminous underside is In
contact with the fabric top surface,rolling the interface Into place with is weighted roller.,
6.5.5 Tile Applications:
Reference Is made to FRSA/TRl April 2012(04-12)Installation Manual and Table 1 herein,using the Instructions noted
above as a guideline. Tile shall be loaded and staged In a manner that prevents the sllppage and/or damage to the
underlayment. j' ;I
Battens must be used for all the installations atop Boral TileSeal SO"'. Boral Roofing's Elevated Batten SystemTM,Tru-
Flow"Battens,or counter battens are required for roof pitches of 2%:12 to fens than 4:12.
6-66 GatorSeal and StormSentrv:,
6.6.1 install GatorSeal and StormSentry In compliance with manufacturers published Installation Instructions and the
requirements for ASTM D1970 underlayments in FBC Sections 1507,'for the type of prepared roof covering to be
installed.
6.6.2 Do not use GatorSeal on roof pitches less than 2:12. Do not use StdrmSentry on roof pitches less than Yt.,12 while
11
ensuring there is no possibility for ponding water on the surface of StormSentry,
6.6.3 Nan-Tile applications.Direct to Deck:
Cut the membrane into manageable lengths,typically 10 to 12 ft. Align the membrane parallel to the roof edge,
extending over by X-Inch.Fold the membrane away from the edge onto itself. Remove the release sheet Place the
membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll Into place with a
weighted roller.
Boral recommends fastening of the black selvedge edge to the decf with roofing nails, nails &tin-tags or 1-inch
diameter plastic or steel cap nails spaced 24-Inch o.c. for sipper below 7:12 and 12-inch o.c.for slopes 7:12 and
greater. Overlap successive courses the width of the black-selvedge area,minimum 3-inch.
Seal end (vertical) laps using SBS Mastic under all side (vertical) laps or any other laps where the self-adhering
bituminous underside is in contact with the granular or mineral top�'surface, roiling tfie Interface Into place with a
weighted roller,or usingthe Inverted Sheet Seam detailed in Boral Roofing published installation instructions.
Exterlor Research and Design,LLC. Evaluation Report M35710.12.10-117
Certificate ofAuthoriraVonA9503 I FUA317-116
Revision 7.04/2912015
Page 5 of 6
I
(yj
\'TP
I i ER
6.6.4 Non Tile Applications,to Base Sheet:
install ASTM D226,Type 11 felt in accordance with Code requiremerts or install Citadel Plus in accordance with Boral
Roofing published installation instructions and Section 6.4.
Install GatorSeal or StormSentry over ASTM.,D226, Type 11 felt or Citadel Plus in accordance with Boral Roofing
published installation instructions and Section 6.6.3 except end{vertical)laps,described below.
Apply SBS Mastic under all side (vertical)laps or any other laps where the self-adhering bituminous underside is in
contact with the granulartop surface,rolling the interface into place with a weighted roller.
6.6.5 Tile Applications.-
Reference is made to FRSA/TRI April 2012(04-12)installation Manual and Table 1 herein,using the instructions noted
above as a guideline. Tile shall be loaded and staged In a mariner that prevents tile slippage and/or damage to the
underlayment.
Battens must be used for all the installations atop GatorSeal,
6_7 Boral TileSeal :
6.7.1 Install Boral TileSeal HT in compliance with manufacturer's published installation instructions and the requirements for
ASTM D1970 underlayments in FBC Sections 1507 for the type of prepared roof covering to be installed.
6.7.2 Do not use Borai TileSeal HT on roof pitches less than 2:12.
6.7.3 Non-TIleApplications,Direct to Deck:
For OSB substrate, prime with ASTM D41 primer and allow to dry prior to installation. Cut the membrane into
manageable lengths,typically 10 to 12 ft.Align the membrane parallel to the roof edge,extending over by%-inch.Fold
the membrane away from the edge onto itself. Remove the release sheet.Place the membrane with the exposed
rubberized asphalt onto the deck,•pressing firmly into place. Roll into place with a weighted roller.
Bore] recommends fastening of the black selvedge edge to the deck with roofing nails, nails &tin-tags or 1-inch
diameter plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c, for slopes 7:12 and
greater. Overlap successive courses the width of the black-selvedge area,minimum 3-inch.
Seal under end(vertical)laps using approved mastic,or use Joined and Folded Seam or Inverted Sheet Seam method
detailed in Boral Roofing published installation Instructions.
6.7.4 Non-Tlie Applications,to Base.Sheet:
install ASTM D226,Type II felt in accordance with Code requirements or install Citadel Plus In accordance with Boral
Roofing published installation Instructions and Section 6.4.
Install Boral TileSeal"T in accordance with Boral Roofing published installation instructions and Section 6.7.3,except
end(vertical)laps,described below.
Apply SBS Mastic under all end (vertical) laps or any other laps.where the self-adhering bituminous underside is In
contact with the fabric top surface,rolling the interface into place with a weighted roller.
6.7.5 'MeAoplications:
Reference is made to FRSA/TRI April 2012(04-12)Installation Manual and Table 1 herein,using the instructions noted
above as a guideline. Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment.
Battens must be used for all tile installations atop Borai TileSeal HT with roof pitches of 2%to less than 3,12. Boral
Roofing's Elevated Batten System or counter battens are required.
Approved foam adhesive may be used for roof slopes 2:12 and greater.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product-
S. MANUFACTURING PLANTS'
Contact the manufacturer or the named GA entity for Information on plants covered under Rule 61G20-3 CAA requirements.
9. QUALITY ASSURANCE ENTITY:
UL,LLC.—QUA9625;(414)245-6409;Karen.buchmann@us.ul.com
-END OF EVALUATION REPORT-