NOV 2 1 20�� EVALUATION REPORT OF ,
z UNION CORRUGATING COMPANY
'26 GA.5V PANEL'
z� BY: ............ .......
FLORIDA BUILDING CODE 5TH EDITION (2014)
IVI� FLO.RIDA PRODUCT APPROVAL
r �
FL 7271.4-R3
ROOFING
METAL ROOFING
I
I
Prepared For:
Union Corrugating Company
P.O.Box 229
Fayetteville,NC 28302
Telephone: (910)483-0479
Fax: (910)483-8897
Is
�a
Prepared By:
Bala Sockalingam,Th.D., P.E.
1
Florida Professional Engineer#62240
1216 N Lansing Ave.,Suite C
Tulsa OK 74106.
Telephone: (919)492-5992
FAX: (866)366-1543
t
This report consists of
Evaluation,Report 3 Pages including cover
Installation Details (2 Pages) osi.SOCK.g4 It"-' �
i No 62240
Z i
o• p � :•
a Re ort.N.o: C19.99-12 p STME OF 40 Z'
P
Date: 3.20.15" �':�•'i° •4
'Ire, ,< O-R t p P,-N X
�
I
x
:f
I�
• . FL 7271.4-R3
C1999-12
3.20.15
Page 2 of 3
Manufacturer: Union Corrugating Company
Product Name: 5V Panel
Panel Description: 24" wide coverage with (5) 1/2" high ribs
Materials: Minimum 26 ga., 80 ksi steel. Galvanized coated steel (ASTM A653)
or Galvalume coated steel (ASTM A792) or painted steel (ASTM
A755).
Deck Description: Min. 19/32" thick APA rated plywood or min. 3/4" thick wood plank
(min SG of 0.42) for new and existing constructions. Designed by
others and installed as per FBC 2014.
Underlayment: Minimum underlayment as per FBC 2014 Section 1507.4.5.1
Slope: 1/2:12 or greater in accordance with FBC 2014 Section 1507.4.2
Design Uplift Pressure: (Factor of Safety=2)
Fastener pattern 1 120.9 psf @ fastener spacing of 24" o.c.
Fastener pattern 2 85.8 psf @ fastener spacing of 24" o.c.
113.1 psf @ fastener spacing of 12" o.c.
Panel Attachment:
Fastener pattern 1 #9-15 or#10-14 x 1.5" long wood screw with washer
At panel ends @ max 6" o.c. across panel width through panel flat
At interior @ max 12" o.c. across panel width through panel flat
Fastener pattern 2 #9-15 or#10-14 x 2" long wood screw with washer
At panel ends @ max 6" o.c. across panel width through panel flat and rib
At interior @ max 12" o.c. across panel width through panel rib
Test Standards: Roof assembly tested in accordance with TAS 125-03 `Standard
Requirements for Metal Roofing Systems'.
Code Compliance: The product described herein has demonstrated compliance with FBC
2014 Section 1507.4
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2014 Section 1609 or ASCE 7-10 using allowable stress
design. The maximum fastener spacing listed herein shall not be
exceeded. This evaluation report is not applicable in High Velocity
Hurricane Zone. Refer to current NOA for use of this product in High
Velocity Hurricane Zone. Fire classification is not within scope of this
Evaluation Report. Refer to FBC 2014 Section 1505 and current
i
i
• FL 7271.4-R3
C 1999-12
3.20.15
Page 3 of 3
approved roofing materials directory or ASTM El108/UL790 report
from an accredited laboratory for fire ratings of this product.
Supporting Documents: TAS 125-03 Test Reports
Farabaugh Engineering and Testing Inc
Project No. T164-06,Reporting Date 6/8/06
Hurricane Test Laboratory
Report No. 0293-0202-06,Reporting Date 4/5/06
Hurricane Test Laboratory
Report No. 0293-0609-05,Reporting Date 8/31/05
i
i
i
i
I
i
I
PANEL OVERLAP _
PANEL FASTENER
SEE DETAIL 2 SEE DETAIL 1 SPACING PER ALLOWABLE
ROOF PANEL �TMIS SHEET THIS SHEET WIND LOAD TABLE d
v �
n
u
DECK ATTACHMENT AND PANEL FASTENER
UNDERLAYMENT SHALL BE INSTALLED SUPPORTS MUST BE SPACING PER ALLOWABLE
AS PER MANUFACTURER'S INSTALLATION DESIGNED AND INSTALLED WIND LOAD TABLE
GUIDELINES BY OTHERS
MIN. 2X_WOOD RAFTER/JOIST/
TRUSS AT MAX. 24�O.C.
TYPICAL PANEL INSTALLATION X—SECTION
s
j9-15 OR#10-14 X 1.5 LONG
FASTENER PATTERN 1 ALLOWABLE UPLIFT PRESSURE
WOOD SCREW WITH WASHER S'� PRESSURE rnz
(PSF)
z -M
(IN) x�a
MIN 26 GA. PANEL 0 Nt�o
24 120.9 z ol+°O1
zw�
Y
u1 Z
d
UNDERLAYMENT PLYWOOD o R
19/32 THICK(MIN.)
a �gm
DETAIL 1
NOTES:GENERAL Ydg
1.ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE30
FLORIDA BUILDING CODE (FBC).
j9-15 OR#10-14 X 2.ALL ROOF PANELS ARE SHALL BE 26 GA. EFFECTIVE COVERING WIDTH OF
1.5'LONG WOOD SCREW OF PANEL=24'.
WITH WASHER 3.THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING&STRUCTURE AS
MIN 26 GA, PANEL SPECIFIED ON THIS DRAWING.
4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT.
THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN
WIND LOADS ARE GREATER THAN THE ALLOWABLE WIND LOAD TABLE.
5.ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING &THE FLORIDA
BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM
REQUIREMENTS OF THIS DRAWING&THE CODE,THE CODE SHALL CONTROL
6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS
REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS.
UNDERLAYMENT PLYWOOD
DETAIL 2 19/32'THICK(MIN.) sss-
cl1
�.
1 2