Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Engineering
A �,- g a C _„ _D ,o E g_ F G H GENERAL NOTES � ` (� SHEET LIST TABLE , 1.1.1 PROJECT NOTES: NEW N S N TEM: 11 .000 k SHEET NUMBER SHEET TITLE /�� ���� 1 1.1.2 THIS PHOTOVOLTAIC(PV)SYSTEM SHALL COMPLY WITH THE 0/ NATIONAL ELECTRIC CODE(NEC)ARTICLE 690,ALL T-001 COVER PAGE THE RELEVANT O LISTING AND INSTALLATION INSTRUCTIONS,AND fAu\V S ON Rr-__-_SDENCE G-001 NOTES LHE kELEVANT CUDES AS SPECIFIED DY THE AUTHORITY HAVINGF-I(! C JURISDICTION'S(AHJ)APPLICABLECODES. G-003 SYSTEM NOTES 1.1.3 GROUND FAULT DETECTION AND INTERRUPTIO14(GFDI)DEVICE IS — ---- 114TEGR.AIED WIIH THE INVERTER III ACCORDANCE WITH (NEC g `! A-101 SITE PLAN ---- 690.5(A)) 00 YUCCA DRIVE — --- —-- -- --- — CONTRACTOR 1.1.4 THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED �`f 1s E_ A-102 ELECTRICAL PLAN 2 1.1.5 LUMSEL INITERCOAND PV SYSTEM P'CECTIOLI SHALLCTED PRIOR BE E INACCORDANCEWITH[NEC FO R I PIERCE, �_L 34982 LLEL OPERATION A 101 — SOLARDIAGRAM PLAN VINYASUN CORP 690.6�1_ G601 LINE DIAGRAM - _ 11.6 ALL PV SYSTEM-COMPONLI4TE 1.40DOEE-UTILITY=INIERACIIVE-=— — — ---- f�_+������� .�� J`���(��! I.(}��(��(1 f1(��= _—_ _ _—_ PHONE: 5614409515 l 'p 7i I fv) I j �f I!f�jlf —.L 6U2— __ ___DESIGNSABLES___ __ INVERTERS, AND SOURCE CIRCUIT COMBINER BOXES ARE ST.l.UCIECOUNTY � w ---- — _= ADDGESS 313DATURASTREETSOITEIDI -- — IDENTIFIED AND LISTED FOR USE IN PHOTOVOLTAIC SYSTEMS AS PLAN REVIEW E-603 PLACARDS WEST PALM BEACH,FLORIDA REQUIRED BY[NEC 690.41&[NEC 690.601 --5 FD1 ASSEMBLY DETAILS 33401 — PV MOCULES:UI.1703 CERTIFIED,NFPA 70 CLASS C FIRE INVERTER(S):UL 1741 CERTIFIED,IEEE 1547,929,519 BLDG c�jz's LIC.NO,: CVC 56967 : a ,i..-.Jt R-00 i RESOURCE DOCUMENT COMBINER BOX(S):UL 1703OR UL 1741 ACCESSORY HIC.No.: - - -- - -= ELE.NO.: _- - --Dq�:_ - --_ .. R-0D7 RESOURCE DOCUMENT 1.2.1 SCOPE OFWORI(: _ - -- - _ - _ ., - - - - -- --- UNA.UTHOHLEO USE OF THIS _ ` _ 1.2.2 PRIME CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND ELEGA R-003 RESOURCE DOCUMENT PFRMIS ION FROM CONTRACTOR - t SP'r.CIfICATiO'JS OF THE GkIU-TIED PHOTOVOLTAIC SYSTEM i — ---— - -------------- HEHMisONOFROMCONTRACTOR IS IN DATE�7 S R-004 RESOURCEDOCUMENI AND IMLL LLBEcUBECTTOCIVIL nws RETROF IT.PRIMECOHTRACTORW1LLBE RESPONSIBLE EDR — _____ — — DAMAGE AESUwOCTTocnNt 3 COLLECTING EXISTING ONSITE REQUIREMENTS TO DESIGN,SPECIFY, + R-005 RESOURCE DOCUMENT oAnncesnNoreosecurrons. AND INSTALL THE EXTERIOR ROOF-MOUNTED PORTION OF THE I'i.UMB: — PHOTOVOLTAICSYSIEMSDETAILEDINTHISDOCUMENT. 1" R-OOo RESOURCEDOCUh4GNI NLINPV SYSTEM:11.0001(Wp DATE:_ ����,�,�p� t \ R-007 RESOURCE DOCUMENT ��uC0Al.ON 1.3.1 WORK INCLUDES: MECH: M d R --`--" -- — --'- �Jl V11.41�uX9 1.3.2 PV ROOF ATTACHMENTS-IRONRIDGE L-FOOT WITH BUTYL SEAL I R-006 RESOURCE DOCUMENT 13.3 PVRACY,IIVCSYSTE641NSTALLATION-IRONRIDGEXR100 DATE: � � i.3.4 PV MODULE AND INVERTER INSTALLATION - CANAUTAN SOLAR R-009 RESOURCE DOCUMENT ' ��lDENGE CS6K-275M I SOLAR EDGE SE760OH-US(240V) I t 1.3.5 PVEQUIPMENTGROUNDING to PROJECT INFORMATION r�903 YUCCA DRIVE 1.3.6 PV INSTALLING SYSTEM MONITORING EQUIPMENT �`I2:ir�(- �. FORT PIERCE,FL34982 OWNER 1.3.7 PV LOAD CENTERS(IF NEC.) Q i ���� ` j NAME: MARIE JACKSON APN:340261002910002 1.3.8 PV METERING(IF NEC.) A L 1 EA 4 1.3.9 PV DISCONNECTS 01 1.3.10 PV GROUNDING ELECTRODE&BONDING TO(E)GEC NOT TO SCALE PROJECT MANAGER 1.3.11 PV FINAL COMMISSIONING NAME: JUSTIN HOYSRADT ' F R-f DE I I 1.3.12(E)ELECTRICAL EQUIPMENT RETROFIT FOR PV --—-- -- - PHONE: 5614409537 CONTRACTOR : vi N I NAME: VINYASUN CORP :U CD �'— I I PHONE: 5614409515 _ CD CV 56 7 _ rt a'^s v U - AUTHORITIES HAVING JURISDICTION I- ;=3jt v� I I BUILDING: STLUCIECOUNTY a CC _. elf``< I o ZONING: ST LUCIE COUNTY �� l�j of 5 1 tig t i r I I U UTILITY: FLORIDA POWER&LIGHT SCOPEOFWORK I I r DESIGN SPECIFICATIONS C,6VPq ISMIF OCCUPANCY: II SYSTEM SIZE: STC:40 X 275W=I1.000KW I PTC:40X2492W=9.968KW CONSTRUCTION: SINGLE-FAMILY (40)CANADIAN SOLAR CS6K-275M GROZONUND D SNOW LOAD: 0 PSIF ENTIAL DATE: 10.302017 (1)SOLAR EDGE SE760OH-US(24OV) WIND EXPOSURE: B. DESIGN BY:O.S. rl WIND SPEED: 170 MPH CHECKED BY: M.M. ATTACHMENT TYPE: IRONRIDGE L-FOOT WITH BUTYL SEAL N APPLICABLE CODES&STANDARDS REVISIONS 6 MSPUPGRADE: NO on PLAT MAP BUILDING: FBC 2014 FRC 2014 w E ELECTRICAL: NEC 2011 T-oo�.00 NOT TO SCALE FIRE: FFPC 2014 s A Ld B C D LE F LaG H (SHEET I) t S A B C _sa D ,v E „ F G H 2.1.1 SITE NOTES FOR THE SITE APPLICATIONS 2.6.8 ENCLOSURES SHALL BE PROPERLY PREPARED WITH REMOVAL.OF PAINTIFINISH AS 2.1.2 A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA 2.4.3 ALL PV CABLES A14D HOMERUN WIRES BE#1 OAWG'USE-2,PV WIRE,OR PROPRIETARY APPROPRIATE WHEN GROUNDING EQUIPMENT WITH TERMINATION GROUNDING LUGS. REGULATIONS. SOLAR CABLING SPECIFIED BY MFR,OR EQUIVALENT;ROUTED TO SOURCE CIRCUIT 2.6.9 GROUNDING SYSTEM.COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE,AND �'�a '��® u 1 2.1.3 THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS AN COMBINER BOXES AS REQUIRED GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR DIRECT Mj]/ UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. 2.4.4 ALL CONDUCTORS AND OCPD SIZES AND TYPES SPECIFIED ACCORDING TO[NEC 690.8 BURIAL. 2.1.4 THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING,MECHANICAL,OR (A)(1)&(B)(1)],[NEC 2401[NEC 690.71 FOR MULTIPLE CONDUCTORS 2.6.10 GROUNDING AND BONDING CONDUCTORS SHALL BE COPPER,SOLID OR STRANDED, BUILDING ROOF VENTS. 2.4.5 ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE DERATED AND BARE WHEN EXPOSED. 2.1.5 PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ACCORDING TO[NEC TABLE 310.15(13)(2)(C)]BLACK ONLY" 2.6.11 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZE ACCORDING TO[NEC 690.451 ELECT RICAL EDUIPIJiENI WILL BE PROVIDED AS PER SECTION[N[C 110.26] 2.4.6 EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2, 90`C RATED,14'ET AND UV AND BE A MINIMUM OF R10AWG WHEN NOT EXPOSED TO DAMAGE(#6AWG SHALL BE _ 2.1.E ALTERNATE POWER SOURCE PLACARD SHALL BE PLASTIC,ENGRAVED IN A RE' ANT,AND UL LISTED RATED FOR GOOV,UV RATED SPIRAL.WRAP SHALL BE USED USED IMTEN EXPOSED TO DAMAGE). I CONTRACTOR CON 51ASTING COLOR TO THE PLAQUE.THIS PLAQUE WILL BE AITACFIED USING AN 10 PROTECT WIRE FROM SHARP EDGES 2.6.12 GROUNDING A14D BONDING CONDUCTORS, IF INSULAI ED,SHALL BE COLOR CODED APPROVED METHOD.IF EXPOSED TO SUNLIGHT,IT SFALL BE UV RESISTANI.ALL 2 4.7 PHASE A14D NEUTRAL CONDUCTORS SHALL.BE DUAL RATED TFIHNfTHWN-2 INSULATED, GREEN(OR MARKED GREEN IF#4 AWG OR LARGER) PLAQUES AND SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE NEC. 90'0 RATED,WET AND UV RESISTANT,RATED FOR GOOV PER NEC 2008 OR 1000V PER 2.6.I3 ALI.CONDUIT BETWEEN THE Ul II-I fl'AC DISCONNECT AND THE POINT OF CONNECTION VINYASUN CORP 1 2.1.7 THE GROUNDING ELECTRODE CONDUCTOR SHALL DE PROTECTED FROM PHYSICAL NEC 2011 • SHALL HAVE GROUNDED BUSHINGS AT BOTH ENDS. ------ -- - ---HA!AABFUETkJI L14 TkI GRO.LIN( 7G FI Ff TRnDE AND T_HE PAI4EL(OR INVERTER)IF ?A.8 4-WIRE DELTA CONNECTED SYSTEMS HAVE THE.PI LASE WITII THE HIGHER VOLTAGE TO 2.6.14 AC SYSTEM GEC SIZED ACCORDING TO[NEC 090.471,[NEC TABLE 250,66].DC SYSTEM PHONE: 5614409515 SMALLER THAN#6 AWG COPPER WIRE PER NEC 250-64B.fHE GROUNDING FI ECTRODF --GROUND-vlARKED-OIW4GE UIl IDEN IFIED'BY-01'H€H LFFFCI IVE-YiEt�N ----— -GF.-'IZED.AG ORDIN [0-(NE 50.,16E tG41N1141UA7 t8l,NGSLHENJNSULATFII 1L8A_WG CONDUCTOR hdILL BE CONTINUOUS,EXCEPT FOR SPLICES OR JOINTS AT BUSBARS 2 9 ALL SOURCE CIRCUITS SHALL I LAVE iNDIViDUAL SOUPCE CIRCUIT PROTECTION WHEN EXPOSED TO DAMAGE. -- ADDRESS:-3 EST PALM SULTE 101-- -— WITHIN L ISTED EQUIPMENT PER[NEC 250.64C.] 24.10 VOLTAGE DROP LIVil I ED TO 2%FOR DC CIRCUITS AND 1%FOR AC CIRCUITS 2.6.15 EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES,EQUIPMEIN78, 33401 Lh1 BEACH,FLORIDA 2.1.8 ROOF COVERINGS SHALL BE DESIGNED,114S TALLED,AND MAINTAINED IN ACCORDANCE 2.4.11 NEGATIVE GROUNDED SYSTEMS DC CONDUCTORS SHALL BE COLOR CODED AS AND CONDUCTOR OR ENCLOSURES SFIALL BE GROUNDED IN ACCORDANCE WITH 250.134 33401 !ti WITH THIS CODE AND THE APPROVED NAANUFACIURER'S INSTRUCTIONS SUCH IHAI FOLLOik'S:DC POSITIVE-RED(OR MARKED RED),DC ENEGI FIVE-GREY(OR MARKED OR250.136(A)REGARDLESS OFVOLTAGE. LIC.NO.: CVC56967 THE ROOF COVf_RING SHALL SERVE TO PROTECT THE BUILDING OR STRUCTURE.URE. GREY) HIC.NO.: -2i.0 RIGID COWDJ1T(ANDIOR-NIPPLES)`MUST-NAVE-A PU6!BUSHING-TO-°ROTE('TAk''!RES, 2.4.12_P_OSITEVF—GROUNDED SYSTEMS DC CONDUCTORS COLOR CODED:DC_POSLfIVE-GREY 2.7.1 INTERCONNECTION NOTES LE,NO.: _ E ^i.'0 BOLTED CONNECTION REQUIRED IN DC DISCONNECTS ON THE WHITE GROUNDED (OR MARKED GREY),UC NLGAT!VC-BLACK(OR MIARKL-O ISLACK) I v i Ii I L LSA IMF€ED C ti KERS',15si Bi LOCA FD i�T-THE OPPOSITE END OF —— DRAWNGSZEDuseoITR I t. i _ 1 URANANGSLIDUSO F1HIS Lr- CONDUCTOR(USE POLARIS BLOCK OR NEUTRAL BAR) 2.4.13 AC CONDUCTORS>4AWG COLOR 00DED 0R MARICFD:PHASE-A 0R L 1-BLACK,PHASE B THE BUS FROM THE 1AAI4 SERVICE BREAKER OR TRANSFORMER INPUT FEEDER IN PERMISSION FR011 C014TRACTOR IS IN 2.i,!,1 ANY CONINECTION ABOVE LIVE PARTS III US T BE VcATERIIGI-I T.REDUCING VdASHERS OR 1_2-RED,PHASE C OR 1_3-BLUE,NEUTRAL-WHITE/GRAY ACCORDANCE WITI][NEC 690.64(B)(7)] VIOLATION OF U.S.COPYRIGHT LAWS AND W LL BE SUBJECT TO CIVIL 3 DISALLOWED ABOVE LIVE PARTS,MEYERS FLUBS RECOMMENDED 'USE-2 IS 140T INDOOR RATED BUT PV CABLE IS RATED T HWNf(H"IN-2 AND MAY BE 27.3 SUM OF BREAKER RATINGS SUPPLYING THE BUS MAY NOT EXCEED 1209c OF THE THE DIWAGES Atli)PROSECUTIONS. USED INSIDE BUSBAR RATTING PER[NEC 690.64(B)(2)]AND/OR[NEC 705.12(D)(1). 22.1 sou:Rcof,I RAG lor, *'USE-21S AVAILABLE AS UV WHITE 2.7.4 GROUND FAULT PROTECTION IN ACCORDANCE WITH[NEC 215.9]&[NEC 230.95]ALL NEVI PV SYSTEM:11.000 INVI) 2.2.2 MODULE CERTIFICATIONS WILL INCLUDE UI-1703,IEC61646.IEC61730. EQUIPMENT 10 BE RATED FOR BACKFEEDING. p 2.2.3 IF APPLICABLE, MODULE GROUNDING LUGS MUST BE INSTALLED AT THE MARKED 2.5.1 STRUCTURAL.NOTES: 2.7.5 SUPPLY SIDE INTERCONNECTION ACCORDING TO[NEC 690.64(A)]AND/OR[NEC 6VAC KSO M GROUNDING LUG 1 IOLES PER THE fANUFACTURERS'INSTALLATION REQUIREMENTS. 2.5.2 RACKING SYSTEM & PV ARRAY SHALL BE INSTALLED ACCORDING 10 705.12(A)]WITH SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH[NEC 2.2.4 AS INDICATED BY DESIGN,OTHER NRTL LISTED L°ODULE GROUNDING DEVICES MAY'BE CODE-CO1,IPLIANT INSTALLATION MANUAL. 230.42(8)1 r USED IN PLACE OF STANDARD GROUNDING LUGS AS SHOWN IN MANUFACTURER 2.5.3 ROOF MIOUNTED STANDARD RAIL REQUIRES ONE THERMAL EXPANSION: GAP FOR 2.7.6 IvdCROiNVERTER BRANCHES SHALL BE CONNECTED TOA SINGLE BREAKER OCPDIiN ] RESIDENCE DOCUMENTATION AND APPROVED BY THE AHJ. EVERY RUN OF RAIL GREATER THAN 40'. ACCORDANCE WITH[NEC 110.3(B)]. 2.2.5 CONDUIT A14D WIRE SPECIE ICATIONS ARE BASED ON MINIMUMCODE REQUIREMENTS 2.5.4 ARRAY SHALL BE A MIN.HEIGHT OF 3"ABOVE THE COMPOSITION ROOF. 5903 YUCCA DRIVE AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. 2.5.5 JUNCTION BOY, SHALL BE INSTALLED PER MANUFACTURERS' SPECIFICATIONS. IT 2.8A DISCONNECT NOTES FORT PIERCE,FL 34982 2.2.6 CONDUIT POINT OF PENETRATION FROM EXTERIOR TO INTERIOR TO BE INSTALLED SHALL BE FLASHED&SEALED PER LOCAL REQUIREMENTS. 2.8.2 DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS APN:340261002910002 AND SEALED WITH A SUITABLE SEALING COMPOUND. 2.5.6 ROOFTOP PENETRATIONS PERTAINING TO SOLAR RACKING WILL BE COMPLETED AND OPENED THE CONDUCTORS REMAINING LIVE ARE CONNECTED TO THE TERMINALS 4 2.2.7 DC WIRING LIMITED TO MODULE FOOTPRINT WI ENPHASEAC SYSTEM. SEALED W1APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR. MARKED'LINE SIDE'(TYPICALLY THE UPPER TERMINALS) 2.2.8 WIRING SYSTEMIS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/SUITABLE 2.5.7 ALL PV RELATED RACKING ATTACHMENTS WILL BE SPACED NO GREATER THAN THE 2.8.3 AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE jzo q, •NAI WIRING CLIPS. SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. O.C. FINAL LOCKABLE,AND BEAVISIBLE-BREAK SWITCH *IN AI MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT ATTACHMENT LOCATIONS MAY BEADJUSTED IN THE FIELD AS NECESSARY. 2.8.4 DC CURRENT CONDUCTORS ARE TO REMAIN OUTSIDE OF BUILDING PRIOR TO EITHER FOR VOC UNLESS NOT AVAILABLE. 2.5.8 ALL PV RELATED RACKING ATTACHMENTS SHALL BE STAGGERED BY ROW AMONGST A FUSEABLE SOURCE CIRCUIT COMBINER BOX OR A LOAD-BREAK DISCONNECTING 2.2.10 ALL INVERTERS, MOTOR GENERATORS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC THE ROOF FRAMING MEMBERS. DEVICE _ 0 IE PANELS,AC PHOTOVOLTAIC MODULES,SOURCE CIRCUIT COMBINERS,AND CHARGE NCD CONTROLLERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE 2.6.1 GROUNDING NOTES _ (D CVCS 96 o = IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4(D). 2.6.2 A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH[NEC 69047 AND[NEC 2.2.11 ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. 250-501 THROUGH [NEC 60 250.1661 SHALL BE PROVIDED. PER NEC, GROUNDING N r a : . ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND BONDED TO AT THE l' •df �p��•' 2.3.1 EQUIPMENT LOCATIONS SERVICE ENTRANCE.IF EXISTING SYSTEM IS INACCESSIBLE,OR INADEQUATE,OR IS i �/ pf F•.• �� 2.3.2 ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY[NEC 110.26]. ONLY METALLIC WATER PIPING,A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE PA�6Rs�y 5 2.3.3 EQUIPMENT INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED USED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT GROUND ROD �J TrsleJ OPERATING TEMPERATURE AS SPECIFIED BY[NEC 690.31 (A)-(B)]AND [NEC TABLE WITH ACORN CLAMP. 310.15(B)(2)(C)]. 2.6.3 GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN#8 AWG AND NO 2.3.4 ADDITIONAL AC DISCONNECTS SHALL BE PROVIDED WHERE THE INVERTER IS NOT GREATER THAN 96 AWG COPPER AND BONDED TO THE EXISTING GROUNDING ADJACENT TO THE UTILITY AC DISCONNECT,OR NOT WITHIN SIGHT OF THE UTILITY AC ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM. DATE: 10.30.2017 DISCONNECT. 2.6.4 PV SYSTEM SHALL BE GROUNDED IN ACCORDANCE TO [NEC 250.211, [NEC TABLE DESIGN BY:O.S. 2.3.5 ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL 250.122],AND ALL METAL PARTS OR MODULE FRAMES ACCORDING TO[NEC 690.431. ACCORDING TO NEC APPLICABLE CODES. 2.6.5 MODULE SOURCE CIRCUITS SHALL BE GROUNDED IN ACCORDANCE TO[NEC 69OA21. CHECKED BY: M.M. 2.3.6 ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR 2.6.6 THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE USAGE WHEN APPROPRIATE. REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDED CONDUCTOR TO REVISIONS 6 ANOTHER MODULE. 2A.1 WIRING&CONDUIT NOTES 2.6.7 EACH MODULE WILL BE GROUNDED USING THE SUPPLIED CONNECTIONS POINTS _oo�.00 2.4.2 ALL CONDUIT SIZES AND TYPES,SHALL BE LISTED FOR ITS PURPOSE AND APPROVED IDENTIFIED IN THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. G A till B 1,31 Q La D LNE F G H (SHEET 2) la A w B o C a—_ D Tp _ E F G H vinyasun CONTRACTOR RACTOR 11000 WATT UTILITY INTERACTIVE RESIDENTIAL PHOTOVOLTAIC SYSTEM VINYASUN CORP 2 NO BATTERY BACK UP LOADS ------- _—_ __— PHONE; 56144095U --- -- -- ---- --- ----- -- — -- — =Ai)DkESS:=a36ATURASTREETSiiFlEi01 — — k The system is a grid-tied photovoltaic system consisting of 40 275 watt Solar PV Modules. Each module is connected to a single DC Power Optimizer which —� 4:ESTPALMBEACH,FLORIDA — are connected in series. The Modules and Optimizer strings are connected to a single inverter Solar Edge Inverter. The PV Supply side of the power 33401 conditioning device is then connected to the building through either a single breaker located within the main distribution panel, a sub panel or through a LIC.NO': CVC56967 Supply Side Service Connection per NEC 690.64(a). Point of connection is diagramed on the electrical diagram. HIC.NO.: —— — — — —-- — — p9 9 ELE.NO.: UNAUTHORIZED USE OF THIS _ DRAVANG SE I WITHOUT W'RITTEIJ -- '-- - -- i FBC 2014 107.3.4.2 Certifications by contactors authorized under the provisions of Section 489.115(4)(b), Florida Statutes, shall be considered PERMISSION FROM CONTRACTOR IS 114 I VIOW ON of U.S.COPYNIGHT LAM equivalent to sealed plans and specifications by a person licensed under Chapter 471, Florida Statutes, or Chapter 481, Florida Statutes, by local AND VJLL BE SUBJECT TO CIVIL 3 enforcement agencies for plans reviewing for permitting purposes relating to compliance with wind-resistance provisions of the code or alternate DAMAGES AND PROSECUTIONS. methodologies approved by the Florida Building Commission for one- and two-family dwellings. Local enforcement agencies may rely upon such NEW PV SYSTEM: 11.000 kWp certification by contractors that the plans and specifications submitted conform to the requirements of the code for wind resistance. Upon good cause � �G" ® shown local government code enforcement agencies may accept or reject plans sealed by persons licensed under Chapter 471, 481 or 489, Florida JACK SON I 6 7 D"- ICE HOW IT WORKS 5903 YUCCA DRIVE FORT PIERJP�,FL 34982 When sunlight is available, The PV array generates DC power which is then fed to the inverters and converted to AC power synchronized with the AC power APVI'�5 0�2 1 (i27 law� 4 supplied by the utility. The inverters meet the requirements of IEEE 1547 and UL 1741. This means that if they detect a loss of utility power, they will �� ati�r oys". automatically disconnect from the utility company. When utility voltage is restored, the inverters automatically reconnect to the utility grid after verifying - t utility voltage and frequency stability. EGf !UE C �+E F RECORD This system, when installed in accordance with the information contained in this package, and as per the installation manuals supplied by the equipment _ � CVC56967 0 = manufacturers, meets all requirements of the latest editions of the National Electric Code Article 690. ,yip The Contractor shall be fully cognizant of the latest edition of the 2014 FBC, 2014 NEC and all local codes, ordinances of the authority having jurisdiction rco Sf and perform all work in accordance with the intent and requirements of these codes, ordinances and authorities ��' od 5 The design of this system is based on information gathered at the site and existing conditions. All measurements and locations should be field verified prior PAPERS Et�TID, to the start of installation. SYSTEM NOTES DATE; 101.2017 DESIGN BY:O.S. Ei CHECKED BY: M.M. REVISIONS 6 G-003.00 ' A L11B LAC D E W F LiG Ld H (SHEET 3) A B C D T E q F GENERAL NOTES 1. FIELD VERIFY ALL MEASUREMENTS 2. ITEMS BELOW MAY NOT BE ON THIS PAGE vinyasun 321-51- PROPERTY LINE CONTRACTOR VINYASUN CORP 2 — PHONE: 5614409515 -ADDRESS-1-ii DhTiTA-STREE-3=SUITfA01-- 'NEST PALM BEACH,FLORIDA 33401 LIC.NO.: CVC 56967 AREA OFWORK HIC.NO.: ELE.NO.: -UNAUTHORIZED USE OF THIS ENTRANCE DftN0l4U3ffWI0UTV7'RITTEN— - - P[RIMSSION FROM CONTRACTOR IS IN VIOLATION OF U.S.COMIGHT LAM' C-) AND WILL BE SUBJECT TO CIVIL 3 METER WAGES AND PROSECUTIONS. AC DISCONNECT INVERTER 0 0 KIEW PV SYSTEM.-11.000 INVP JACK30, r R E E 8�D E N C 5903 YUCCA DRIVE FORT PIERCE,FL 34982 APN.-340261002910002 4 L�l FX)!�R ,kK N E 38'-3" f : -7 CVC56f"k 1 CID - Lo op, 5 FQW ol DATE: 10.30.2017 DESIGN BY:O.S. CHECKED BY: M.M 6 SITE PLAN W N[j]E01 REVISIONS 1/16'=l'-O' 0 81 16' IS A-101.00 A B C D ki E F Ll G Ld H (SHEET4) A B C D F G H GENERAL NOTES FIELD VERIFY ALL MEASUREMENTS 1 i.2. ITEMS BELOW MAY NOT BE ON THIS PAGE vinyasun CONTRACTOR 0 MODULE STRINGING 2 O MODULE STRINGING VINYASUN CORP PHONE: 5614409515 WEST PALM BFACH,FLORIDA 33401 L C.NO.: CVC 56067 HIG.NO.: ELE.NO.: UNAUTHORIZED USE OF THIS DR-WONGSEI 'EIU'ISSII,)K'FP.C%ICONIRACIORIS IN VIOLAI ON OFCOPYRIGHT LAWN' AND AIIE BE SUBJECT TO CIVIL 3 DAMAGES AND PROSECUTIONS. 0 NEW PV SYSTEM: 11.000 kVVI) ARRAY 1 11.000 M (N)MODULES JACKSON TILT:15 DEGREES ROOF PITCH:3:12 REMENCE E AZIMIJTH:270 DEGREES t� 0000000000000 5903 YUCCA DRIVE FORT PIERCE,FL 34982 --------- AP N:340261002910002 4 EH,G,I�T-15q/ ESIGNER -ate /60 EXTERIOR PV EQUIPMENT EXTERIOR PV EQUIPMENT (E)(1)METER (N)(1)INVERTER x CD IN)(1)AG DISCONNECT CD CVC5 9B7 - INTERIOR PV EQUIPMENT (E)(1)MAIN ELECTRICAL M11-11 • (ft RS jAA;I L9 f 10 LE13TR 11/1// ol 39.1 DATE: . R DESIGN BY:O.S. T- MODULE: CHECKED BY: M.M ELECTRICAL PLAN z 6511 CS6K-2 CANAD 75MIAN SOLAR REVISIONS 6 1/8'=V 0 4' 81 -L 275 WATTS A-1 02.00 A B C D Q E Li F G LA H (SHEETS) A -- ra —B C p ___ D _ E — r� F w G H GENERAL NOTES 1 t. FIELD VERIFY LOWMALL MAY BE vinyasun 2. ITEMS BELOW MAY NOT BE ON THIS PAGE ��!! i� ROOF TRUSSES --— CONTRACTOR VINYASUN CORP 2 PHONE: 5614409515 —AiIUP,ES5=3i'MURkS'TREEfiSUtT"01 WEST PALM BEACH,FLORIDA _ 33101 LIC.NO.: CVC 56967 HIC.NO.: ELE.NO.: UNAUTHORIZED USE OF THIS URAW NG GEl WITI IOU I WRII1 LW PERMISSION FROIA CONI RACTOR IS IN VIOLATION OF U.S.COPYRIGHT LAWS __.-T____I_.-._T-_r'_.)�T--f-_T--1-_I�-r-T �-i AND V19LL BE SUBJECT TO CIVIL 3 I _b� - - -o— -_p _ I I DAMAGES AND PROSECUTIONS. I I I I 1 I I I I I I I I I I I I I I I I I I I NEW PV SYSTEM:11.000 lc1AJID I I I I 1 1 1 1 1 1 1 1 I 1 1 1 11 1 I I I 11 I I '�4} 'l�/(`'��� �1p�(�1�t�Yi O N FLUSH MOUNT SOLAR MODULES ' y L ATTACHED TO ROOF SURFACE(SEE hotE 4 E I I I i I I I I I I I I I I I I I I I I I I I I SHEET S-501 FOR MOUNTING DETAILS) I -1 I I 5903 YUCCA DRIVE I 1 1 I r I I I I I 1 1 I 1 1 1 1 1 1 1 1 I 1 1 1 FORT PIERCE,FL 34982 I I I I I I I I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I I I I I I I 1 1 1 1 1 1 APN:340261002910002 a I I I I I I I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 ROOF MATERIAL IS CORRUGATED METAL .`�\ �\t\0 te •, C _ U CVC5 67 o - 46-911 am m 39.1 DATE: 10.30.2017 T I I DESIGN BY:O.S. T MODULE: CHECKED BY: M.M CANAS®LAR ATTACHMENT PLAN z w 6511 CS6K12 5MSOLAR REVISIONS IAN 6 01 ve°=r o a' Bd y � 275 WATTS Am103.00 A B wC LdD UlE F LbG mH (SHEET6) A. a� B r._.� D E �-�o FW_ G H CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS ID TYPICAL C014DUCTOR CONDUIT CURRENT-CARRYING CONDUCTORS OCPD EGC TEMP.CORR.FACTOR CONDUIT FILL FACTOR CONT,CURRENT MAX.CURRE14T(126%) BASE AMP. DERATED AMP. TERM.TEMP.RATING AMP.@ TERMINAL L/ IN CONDUIT 4' 1 0 2 12 AWG PV WIRE,COPPER FREE AIR 2 N/A 6 AWG BARE,COPPER 0.76(54.8•C) 1 15A 18.75A 40A 30.4A 75•C 35A ����� 0' 1 8 AWG THWN-2,COPPER 0.75°DIA EIAT 2 NIA 6 AWG THWN-2,COPPER 0.96(32.8•C) 1 32A 40A 55A 52.8A 75•C 50A sun 199 1 8 AWG THWN-2.,COPPER 0.75'DIA EMT 2 _-L 401, I 6 AWG THWN-2,COPPER 0.96(32.6•C) --_ 1 32A 40A 55A 52.8A 75•C 50A OMODULE STRINGING � Op �—� CONTRACTOR (D MODULE STRINGING ST.LUCt'lECouNTY j4 � O CD - — PLAN jL Q R VINYASUtJ CORP — ._- -- - f' j'- 'v� '!'' PIIONF 5614409515 - -- — _ _—ell? . I�J ---- -'---- ---ADDNtsS:tii�6ATURiiSTREfT=SUtTE=101---WEST _ ELE C-i z 33401 PALM BEACH,FLORIDA — LIC,NO.: CVC 56467 HIC.NO.: / ELE.NO,: _UNAUTHORIZEDUSEOFTHIS DATF I PERMISSION FROM CONTRACTOR IS IN IAOLAI CO A 14D WILL IBE SUBJECTPTO CIALYRIGHT�`� 3 �� Q z C.) I (� UAIAAGES AND PROSECUTIONS. uJ DATEt _ w w Q I NEW PV SYSTEM:11.000 IcWp S z Luo � oQ JACKSO � � z � o cco CD af o :E I r------�—�1 5903 YUCCA DRIVE a o0 I I 0 FORT PIERCE,FL 34982 �— 0 -- o o A'1J:340261002910002 Q ® © � _z g-- i 0 w ENGIWEFR DESIGNER ON m ¢ I W \\\CD CDwH:CN o w ¢ gate ( ' •�p%, ol. `. + ; - N ' :Ci `D CVC569 7 0 - U 5 O o 6®m ¢ 111�••• p�PPER EA N z J v IA9R60 \\�� w cD � z Q '�� Soar N os >O 2) oo DATE: d36.QUi11111 O N w Q w m — w LLJ ° N `� DESIGN BY:O.S. w - w Z X = C) w Lo W 0 w = z0 W Z w W > � W CHECKED BY: M.M. � N � w � o cVn EL o- U) Ujci U)- m mQ REVISIONS g QY o cfl p ww z � z XX < U) 0OM Ow U az or 0 Q Q ¢ o UU U) Wd U) cl) Q wJ w J � Z � N � � N E-601.00 A B C LdD w E LaF G H (SHEET 7) _ A n _ B n -_ C — --� -------_- E re F -� G H SYSTEM SUMMARY MODULES STRING#1 STRING#2 REF. QTY. MAKE AND MODEL PMAX I PTC I ISO IMP VOC VMP TEMP.COEFF.OF VOC FUSE RATING 1 POWERBOX MAX OUTPUT CURRENT 15A 15A P1-40 1 40 CA14ADIAN SOLAR CS6K-275M I 275W 1249.2W I 9.31A I 8.8A I 38.3V 31.3V -0.119VPC(-0.31%/'C) 15A �'��� OPTIMIZERS IN SERIES 20 20 __ POWER OPTIMIZERS sun NOMINAL STRING VOLTAGE 400V 400V _ARRAY OPERATING CURRENT 13.75A 13.75A k�REF. QTY,I hFODEL _ RATED INPUT POWER MAX OUTPUT CURRENT tdAX IIJPUT ISC IdAX DC VOLTAGE WEIGHTED EFFICIENCY ARRAY S'TC POWER 11,DOOVJ 1-40 40 �_ SOLAR EDGE P320 320W 15A L_ 11A 48V 98.8% ARRAY PTO POWER 9,9G8VJ -- - --- ---_- ------ --- -- - - '- --- - '- --------- _--. — INVERTERS - -- - __ 32A ---- -- -- ---- - --- -- _ -- MAY,AC CURRENT _ _ ,.-_- -_ i ----- OCPD h4'J:OUTPUT MAX INPIJI CEC WEIGHTED - /6CGW RPF.OII' NAKE AND FI,ODCL AC VOLTAGt GROUND RATING RATED F'OVJGR _CURREN_I __ CURRENT JJ\X INptl VOL IfiGF EFFICIENCY CONTRACTOR IZA�'T®R DEBATED(CEC)AC POWER - 7,6D0'dJ 11 1 SO! R EDGE SC7600H US(24DV) 24DV FLOATING 40A 760UW 32A - 20A 480V 99.0% -------- —_—DESIGN TEMPERATURES_ I_��-- — ------ —�-- -- _------- L VINYASUNCORP ASHRAE EXTREME LOVJ -3.2.'C(26.2`F),SOURCESTLudE-CO INTL(27.5";-80.38•) ___ DISCONNECTS __ _ � OCPDS REF. QTY. MAKE AND IJODEL RATED CURRENT VAX RATED VOLTAGE QTY. RATED CURRENT MAXVOLTAGE�hS - __ 91"F),SouRCE's1 FUCIE CO INTL(27.5";-8D.38") - - -- --I --- IE: 5614409515 — --- 'Stier-i SC�UAF�D-DU222RB.OIi.CQUIV. 60� 24DVAC 1 40F, 60OVAC PHONE: —_ --- _ ADDhF6S:;r36kTUPJiSTPEET SJhT�-1(}i -- -- - - - -- - - -- - - _ PILL OF_MWERIALS -- __ —_- ^___ - ------- WEST PALMBEACH.FLORIDA CATEGORY MAKE IdiOUELPdUk;t+L'R RE-F PITY UNIT QiYIUNIT DESCRIPTION _. _ 33401 I MODULE---_—__---__- _i____-CANADIAN SOIAR - --CS6K-275M -_-_ PM1-10-�40 PIECES -_- 1 -_�CANADIAI S01_AR,CSGK_275M 2751N 60 CELLS,MONOCRYSTALLINE SILICON _ __ LIC.NO.: CVC 56967 INVERTER SOLAR EDGE j SE7600H US(24DV) I I i 1 I PiCCE 1 SOUtR EDGE SF760OH-US(24DV)76DOW IIVERTER - -' - - - HIE.NO.: MODULE OPTIMIZER SOLAR EDGE _ P320 _ �_ P01-00 QD PIECES _-1 SOLAR GUGC!370 OP11NdZER(REQUIRED PART OF INVERICR'S DISTRIBUTED DC ARCHITECTURE) DISCONNECT SQUARE D- - -DU?T+RP �_.-SWt _I_ l _21CCE i 1..SQUARE D DU222RB,2-POLE,GOA,240VAC OR EQUIVALENT _- _ _ -- _ - _ _ UNAUTHORIZED USE Of THIS WIRING __ -GLty 12-AVUG I VC11RE-Cu _-_--mil 18U I ELT 1 j itf,WG=VVtgRL,COP['[R(POSIIIVI AND IJFWtiTIVLj -__- -_-_ - DRATi�1i ucsri'�riROUTvFrzTtl: - --- - "--- - - GENG-A,INGCh`�F-CU 'NRi "0 FELT SF,VGDARE COPPER(GROUND) PERIAISSION FRO%l CONTRACTOR 15 IN WIRING _ _I_ - -----.-----..�-------'--- ---- _I--=--. _L__-..-.. _ __ -. --- ___.-. _-- --.-._--_---. ----_- -_ ---- VIOLATION OF U.S.COPYRIGHT LAWS I WIRING _ _ GEN 8 AWG-THWN-2 CU-PD— I-WR2-3 50 J FEET-j - 1 8 AWG THLNN-2 COPPER.RED(LINE 1) - - - _ ANDWLLBESUD!ECTTOCIVIL 3 WIRING --_-� GCN 8 AWG-TIi14'6!'L CU BLK_- WR2-3 50 I FEET -` T I 1 8 AWG WN-7 COPPER,BLACK(LINE 2) —— _ --- DAUAGESNID PROSECUTIONS. ---- ------- _ _ -- - GEIJ-B-AVJG=fHUdIJ 2-Cll-Whl Wk2-3 50 FEET 1 8 AWG THWN-2,COPPER,WHITE(NEUTRAL) -------'--'"- - �0 FED I 1 G A1NG TIiWh!7,COPPER,GREEN(GROUND) NEB^u PV vYSTEM: 11.000 IcWh WIRItJG GEtJ 6 AW'G-1 HUJN-2 CU-GR -� VJR2-3 I = `- � - - — WIREWAY -_--- GEN EMT-0,75"DIA NNV2-3 30 _FEET 1 I EMT CONDUIT,0.75"DIA GEN`CB-4OA-24OVAC--_—_,._ CB1 { 1 PIECE �- -_- 1 CIRCUIT BREAKER;40A,240VAC OCPD--- J oY� 4S'II�; !lES60E14C E 5903 YUCCA DRIVE FORT PIERCE,FL 34982 APN:340261002910002 4 \� (�€E>'E(" S} � LD9NER P Caltf :( N CD CVCS 967 CD o - %� •N � •tom L PIT //�777IMai111\�E$ DATE: 10.30.2017 DESIGN BY:O.S. CHECKED BY: M.M. REVISIONS 6 E-602.00 A g C D E L&IF FMG H (SHEET8) A E G H DO 20 GENERAL NOTES 27 50 1. FIELD VERIFY ALL MEASUREMENTS vinyasun i2_95-PRE 23 24 25 1 VINYASUNCORP D TA I NGITUDINAl PHONE: 5614409515 NOT TO SCALE WEST PALM BEACH,FLORIDA I ROOF MATERIAL:CORRUGATED METAL 1 33401 2. ROOF STRUCTURE:TRUSS .1 ATTACHMENT TYPE lRONRIDGE L-FOOT114TH BUTYL SEAL m LIC.NO: CVC 56967 4. 14ODLJLE MANUFACTURER:CANADIAN SOLAR HIC.NO.: 5. MODULE MODEL:CS6K-275M ELE,NO.: 6. MODULE LENGTH.651. UNAUTHORIZED USEOFMIS 8. 1,40DULF WEIGHT:40.1 LBS.LWIDIH.39.1' p [jl-lA?liffG iVRFITEM I PLIMISSION FROM CONTRACTOR IS IN OLATION OF U.S.rOPYRIGHT LAWS NOT TO SCALE 9. SEE Si iEET A-1 U3 FOR DIMENSIDN(S) ViDWILIBE URJECTTOCIVIL 10. TRUSS SPACING:24 IN.O.G DMIJ'AAGES ANS PROSECUTIONS. il. TRUSS SIZE:2X6 N014INIAL (D 12, LAG BOLT DIAMETER:5116 IN. NEW PV SYSTEM: 11.000 kWp 13. LAG BOLT b4BEDMENT:3 IN. 14. TOTAL V OF ATTACHMENTS:75 S. TOTAL AREA:706.97 SQ.F 1. JACKSON 10 G. TOTAL WEIGHT:1837.25 LBS. 17. INSIGHT PER ATTACHMFNT'24.5 LBS. 18. DISTRIBUTED LOAD:2.6 PSF. RESDENCE 1 q. MAX.HORIZONTAL S FANDO FF:48 1 N. 20. MAX.VERTICAL STANDOFF: 5903 YUCCA DRIVE LANDSCAPE:26 IN.,PORTRAIT:33 IN. 21 21. STANDOFF S rAGGERING:YES FORT PIERCE,FL 34982 22. RAIL MANUFACTURER(OR EQUIV.):IRONRIDGE APH:340261002910002 23. RAIL MODEL(OR EQUIVALENT):XR100 4 24. RAIL WEIGHT:0.68 PLF. 25. MAX.TRUSS SPAN:8 FT. 26. MODULE CLEARANCE:3 IN.MIN.,6 IN.MAX. AN RISK CATEGORY:11 EXPOSURE CATEGORY:B 7O - VULT:170 MPH ate • /0-9 3 RACKING DETAIL TOP CVC56 c) NOT TO SCALE 0 (p JlAPEqkEi.1 DATE: 10.30.2017 DESIGN BY:O.S. CHECKED BY: M.M, DETAIL (TRANSVERSE) DETAIL (LONGITUDINAL) REVISIONS NOT TO SCALE ::D5]4OSCALE S-501.00 B C u D w E LA F G Ail H (SHEETIO) --A- r4 ---- 6 E --p----- F -- -- G H faIri" At vinyasun ®� C a n a d i a n So la r ENGINEERING DRAWING(mm) ALL-BLACK CS6K-280M/I-V CURVES S r t . Rear View Frame Cross Section A•A A 0 oa �+ �'�� � -❑ J ! c a s I Es�le i�G7FeGTC�h-- VINYASUN CORP 2 _ — ___ - a a . � r � ... Mounting Hole x x _ s PHONE: 5614409515 sa. � � 1 � �- —..�e_-,- ,— -,', �•S:�'r}kfth?AfiT4�T�U1TEiC1-- 1 In Is 3TG 1 30 35 00 S 1U 5 20 Is so sa CO _----- - INEST PALM BEACH.FLORIDA ? .•= ° j a JA ■ croowm� 6r■ 33401 . ■ aoawmr u<■ -'-' ■ -w— 6•<r LIC.NO.: CVC 55967 — A - - ■ aoomm arrc■ ELE. O. ALL—BLACK ^ QQ �►/� ELE,IdO.: I CS6K-27o 1275 120o IMI --- --- - I -- ---- - - - t U JAUTIIORLEDU1I OF THIS 1 ELECTRICAL DATA STC� MECHANICAL DATA — --- -- I Z/::i'af' s!.r..�fN.`;uTs'„9Tir";:-- E! All-Black CS6K 270M 275M 280M S ecification Data , r[RrvsslolJ rrors cornencloR Is Iw I ............._......................-........_.................._................._........................_..... ....__-.................................................._......................_..................__............. IOLATICN OF(I,S.COPYRIGHT L AWS Canadian Solar's ALL-BLACK C56K-M modules are Nominal Max.Power(Pmax) 270 W 275 W 280 W Cell Type Mono-crystalline,6 inch M ANDWILL BE.SUBJECT TO CIVIL 3' equipped with dark mono-crystalline cells,a dark 4 Opt.Operating.Voltage(Vmp) 31.1.V 31.3 V 31_5 V Cell Arrangement 60(6 x10)_- I DAI:AGES AND PROSECU1IOIJS. colored backsheet and a black frame for enhanced i �.. Opt Operating Current([cop) 8 67 A 8 80 A 8 89 A Dimensions 1650x992 40 mm(65.Ox39.1x1.57ln) ...... ...... .... ... NEVV PV SYSTEM: 11.000 kkN of 38.2 V 38 3 38 5 V ei ht 18.2 k 40.1 Ibs p aesthetics and reliable output This product can �a �.P.enCircuitV_rage(Voc)......._..........................:...V.........•........ W.._4..........................................g.j.............._�....._.........................._....... it ul u r nt Ise 9.19 A 9.31 A 9.43 A Front Cover 3.2 mm tem Bred lass Improve the aesthetic of a rooftop. Short C c t C._r.e.....j_._.)....._...-------...---.---._....._.. ........_.... P g............. .... ' n� y II_..........._......................._ CCCVVUH llu C p Module Efficiency 16.50% 16.80% 17.11% Frame Material Anodized aluminium alloy � r'�,�a j�� Operating Tem erp azure -40°C-+85°C J-Box IP67,3 diodes KEY FEATURES ? linear power output warranty Max.System Voltage 1000 V(IEC)or 1000 V(UL) Cable 4 mma(IEC)or4 mm"&12 AWG F", -, ,� , C, Module Fire Performance TYPE 1(UL 1703)or 10DOV(UL),1000 mm(39.4 in) r F'y•-6• N tl I 1 CLASS C(IEC 61730) Connectors T4 series or PV2 series __ r Excellent module efficiency of __ __g — p_ 9__ 1903YUCCPaDRIVE + Max.Ser{es Fuse Ratin ---15A - - Per Pallet 26 feces 520 k-(114641bs) — r- up to 17.11% 10 product warranty on materials Application Classification Class A Per Container(40 HQ)728 pieces Years and workmanship - ----- - - I FORT PIERCE,FL'34982 _ P Outstanding low irradiance ..........._..._..............................-....................................................................... uwe scawaa ercanaidona(ncleriRolanreer 000wimt�pen�nAM f APN:340261002910002 performance of up to 96.5% Isandoc'Imnperabaeof7S•C 4 MANAGEMENT SYSTEM CERTIFICATES; I509001:2009/Quality management system ELECTRICAL DATA I NMOT- TEMPERATURE CHARACTERISTICS - -f-L IP67 junction box for long-term ISO 14001200d/Standards for environmental management [end All-Black CS6K 285M 290M 295M S edfication Data F`ET.1 e911� F,} IGNER 9 zn ......................_.... P.........................._..........................._..........__._...... ..............._......._...... \ / IP6) weather endurance OHSAS 18001:20071Internatiorel standards for occupational health and safety Nominal Max.Power(Pmax) 197 W 201 W 205 W Temperature Coefficient(Pmax) -0.41%/°C \\ \\ en oc -0.31%/aC \ Opt.Operating Voltage(Vmp 28,5 V 28.7 V 28.9_V Temperature Coeffici t[V ) `-� ... . PRODUCT CERTIFICATES- Opt O ep rating Current(Imp) 6.93 A 7.02 A 7.10 A Temperature Coefficient(Isc) 0.053%/°C �5,.•• ate ••••• of * * Heavy snow load up to 6000 Pa, - - - G IEC 61215/IEC 61730:VDE/CE I MCS ICEC AU O en Circuit Volta a(Voc) 35 5 V 35 5 V 35.7 V Nominal Module Operating Temperature(NMOT) 44t2°C \ e C wind load up to 4000 Pa} .P.---- -----9 ---__._..----- -- _------ --- ---- - - -- -----. .. ..- . \ ,`\ 9•• i UL 1703/IEC 61215 perforrnante:CEC llsted(US) Short Circuit Current(Isc) 7.43A 7.52A 7.62A UL 1703:CSA •Under Nominal Module Operating Temperalure(NMOTL irradiance of800 W/ Take-eway m'.spectrum AM 1.5.ambient temperawre m"G wind speed t ms,. = ct� •• ••. O _ CVC5 67 : _ r` ^n,.cEaT PERFORMANCE AT LOW IRRADIANCE PARTNER SECTION rYE c$Pea\ \ rJ BBAV �� E.^.. -- Outstanding performance at low irradiance,with an ............................._.................................................................................i '�••r••. / ate:• I •please contact your local Canadian Solar sales representative rot the specific productaverage relative efficiency of 96.5%from irradiances, ( ( /(ANSI 6 _ifirates appuciblein you,markes, between 200 W/ma and 1000 W/m'(AM 1.5,25°Q. s _ _--_- ..................................................................................................................:............. 0 VkRENT LAR is committed to quali CANADIAN SO solar products,solarIsystem solutions and servicesnto cugstomersry around the world.As a leading PV project developer and DATE: 10.30.2017 manufacturer of solar modules with over 20 GW deployed around The aforesaid darasheet only provides ere general Inrormatmn on Canadian sear products and,due to the on-going Inn ovation and Impravemen4 Please always the world since 2001,Canadian Solar Inc.(NASDAQ:CSIQ)Is one of contatcyour local Canadian Solar sales representative tormeepaarod infom a bn DESIGN BY:O.S. the most bankable solar companies worldwide. omspecificodors key featnresandcw ificai arl.1rementaotc adianSolar prod"inyour regron. CHECKED BY: M.M. plea%be ldndy advised chat w modules should be handled and In tared by •fordetat lnformatlan.pkax refer tolnsiallallon Manual. Qualified peoplewlw lave professkmal ski0s and pkax carefully mad dhu safey i ................................................................................................................................................................-----................................................._....................-. and I-11atbminstruttien before using our w modules. -:..............................................................._..............................................: REVISIONS 6 CANADIAN SOLAR INC. .............................................................................................................................................................................................................._.... 545 Speedvale Avenue West,Guelph,Ontario N7 K I E6,Canada,www.canadiansolar.com,support@canadiansolar.com CANADIAN SOLAR INC.May 2017.All rights reserved,PV Module Product Datasheet V5.54_EN R-001.00 A Lai B U C U D E is F W G H (SHEET 11) ADA__.---_ B ___ -.____._._._�� -__- ----- - ---_.-_._.-�_- _E____ .- _Fa_-___-_..----F-------_-I—__�__-�.— -_ H 1 VIA yasu l �I solar=@oSingle Phase Inverters for North America Sklar . , c: SE3000H-US/SE380OH-US/SE5000H-USISE6000H-US/SE760OH-US CONTRACTOR SolarEdge Single Phase Inverters _.._..__-__.-_- -____.__-- - _ _ ___—__ _ -__----_.__--- ----__- ■ SE3000H-US SE3800H-US SESOOOH-US SE6000H-US Sq 14 US VINYASU14 CORP OUTPUT _ ---,-_ for North America Rated AC power Output l .ili 3800 I 5000 i 5000 76.. ,VA Max AC Power Output a000 3RDo 1 5000 6000 760p vA PhI01JG: 5614409515 SE3000H-US/SE3800H-US/SE5000H-US%`SE6000WUS-/ �copmucyata eM r Nom rrx lis3 R. .... . ---__._' ✓ —vat =_ NV j t SE7600H US nc iutp ivpltaaeMl Nom v1a Izn za0 z6u) ✓ - ,,�.,- ✓ ✓ i vac - - Dkf'iRkSTRtE SUITE? ,- Acrreoucncy(Ngmnal).•...•' 59.3-60-605a - H 'AlESTPAI_MBEACULORIDAu .......... Maximum Continuous Output Current 208V - - 24 - - _ A :... I .... 3401 Maximum Continuous Output Current 240V 12.5 16 21 25 32 A ......... ... ...._..................... GPDI Threshold 1 A I_D.NO.: 0 0 6 7 ...:.y ono o.ng.......ng Pr...... ....... ...... .. .. .. ..............- .... .. Uhlit hlonitorin Is!andinRprotecdon. � NIO.ND.: Yes coy0�ty.coengyat,Ien,_r>nnoia�------_ ._....___._...................----`---------------------------------_---` --------------- ELE.WO.: -_ INPUT ____ ___—________._ UNAUTHORIZED USE OF THIS Maxm,dm DC Powe 4s5D SS n 7750 oleo 71800 w • +� a " � r..' Iransformerless,,un�rounded,• -Y 5 .. .. � 1^:�IssloN reo�a eorllenc rnr,Is pl V[DIAII01,101 U3 COPYR13KI!AN5 3G,,.layy, }„ ' °¢e < y vysan"sn�d A Nom al DC Input Voltage_ _ _ _ 380 400 Vdc AND WILL RE SUBJ[CT TO CIVI! 3 -aa,+N+, 4 y�dJ+" ;h- " `t;,, Man I p tC went 208V - .,.,,,., :. 155 •:. _ Adc D/a.MGESANDPROSECUTIO!JS. �• '° y t "W* ` Maa m n Input Current 240V 8,5 10 5 13 5 16.5 20 Adc -r' 1 r, :.:''' Max,Input ShoN Clrt RC t ... 45... .. ..Adc... €\I�1/V n�/J 1 S I 1.000 MA/€) ` O '�h •. Rev Pol rI[y P [ecnon Yes .. .... ... % " a��'; GroundFault Isolation DeteUwn _ _ _ ,,,. ,. .. _ ,,.................600ku5 ... ...... -,... ,,. {j II/p•GG�(1�}� p w m a.u,,.Ds • ^. @+ai; Max v)invert.Hhoe w .9.......... .. ...�9.:'� ... .. .. I'f(,Sl0li� ... .. ......... -. .. .. .. CEC We'prhted E(n ency 90 °4� 'r 1. ... _ N!Rhro :Power Consumption I 2.5 W II,'- !(,SElF5U5TA1NING POWER OUTLET(OPTIONAL) _ �- __._ V 4� F t k_z 5 • .... .. .... ... J _ u i 'cr Nom l mal Output Voltage 120 � - . Maximum Ou[put Power 151xf' � W - - ` tgrnalourleC With eFDi 5903 YUCCA DRIVE f ADDInoNALFEATUMS —_-- FORT PIERCE,FL 34982 - ': Supported Communiwnon Interfaces R54.95 Eth t Z18Be (opnonary Cellular lopno.... ..,.:. ; Revenue Grade Dat ANSI C32.20 Opt oar" ArPi•3402 4` Rapid Sh tdo m_NEC 2014 690.72 1 Auto n Rapid Shutd n upon AC Grid Disconnect , 61002910002 L_ Q Safety _-UL3741,UL16998 CSA C222r Canadian AFClaccoNln4 to TIL M07I _ -Grid Cennecuon Standards .•. -------_--_ -- IEEE1547 RUI 21 Rula74lH1) —�- _—`_ 1 .... �'� � +, �'r��€�j�ER V Emirs 5 FCC Part 15 Class a \' / -_ 1 -- — _. _...-__ \\ _{ INSTALLATION SDECIFICATIONS \ klY// ____ _7 AC Output Condut Size/AWG Range............................. .... „.,--0.75.1'Condurt/14b AWG..... ... ... ... .......... 11 \\��-`-' .... y� l i'.. .. � DCI p tCond tSl a/Rof Sh ngs/Al4G Range .... Conduit/12st ngs/146AWG 1 0 •• 4 Uim unswhhSaf tyswitch(HxW D) 177x145 A/450x370x174 n/min , ,• •\cafe Weightwith Safcty5 tch • .. Noise ............. .. ....... .. ...-...... .. ..... ................................. Ib/kg ;•�\` t51 i ..... CD OperanngTemperaWre Range ., -13 to�140/-3510.60^{40 F/40'C opnpnJn+ ! 'F/,'C. _ C it _ - ` } ProtecnonP d NEMA 3R(In c rcr th5 f ry5witch) — CVC5 Optimized installation with ND-Wave technology s _ _ 1 O -Specifically designed to work With power optimiters. ( r•m•ay.m«,w •..n;u>artdaPwe«�n - C.1 1 Record-breaking efficiency •r a.r<•�•a•de lmh•,P/N 5c.,..R-mauanna �1—d, SaT -nU�x,I.wn Integrated fault protection for NEC 2011 690.11 and integrated rapid shutdown for NEC 2014 690.12 "'per'='°^Pl"� •irt°"$0L1"'"ua 6 ; ntegrae arc � r� ' .• fIzv JAAsI�'�• Extremely small I - High reliability without any electrolytic capacitors 11111111111 - --- - - ----. - ----. - - - -- - - - -- - - - - - - T Built-in module-level monitoring - - - wavP. Outdoor and indoor installation - DATE: 10.30.2017 Optional:Revenue grade data,ANSI C12.20 Class 0.5(0.5%accuracy) • sunsAtc � DESIGN BY:O.S. USA CANADA-GFRM ANY-I TAT.Y-FRANCE-JAPAN CHINA-AUSTRALIA A HE NETHERI.AN DS-UK-MFAEI'IURxEY-SOUTH AFRICA"MICAHA www.solaredge.us - CHECKED BY: M.M. REVISIONS 6 R"002,00 A B C WD LaE F G 15H (SHEET 12) L A B H %nnyasun • solar=a@ T solar=@ * T SolarEdge Power Optimizer Module Add-On for North America P300 If P320/P370/P400/P405 .................................. ............................................ .......... ................ 00 hlgb-p..e, P370 _�,.r7p 96-11 1, VINYASUN CORP 2 SolarEdge Power Optirnizer P300 P320 60-cell 1. 1 or higher power �4. ules 611,01 rr.dules) 60 and 72-H module,) module,) module, .......... Ifr ........................ ... .............. PHONE: 5614409515 Module Add -For North America__ .405- Rated)Put DC Po er ..... . - ADUMIESS:313 DfATOWS i w-L i SUITF 1 P300 P320 P370 P400 P405 01- • Ab fv�ximum Input Voltage 48 60 i_�i ED 125 'NEST PAW BEACULORIDA ...........ISME6........ ...... ............................... _ I . 2 33401 ' ...... . . .... .... ........A. . .... . .............. J. A'.J.� �� I• 1C NO.: CVC 5696 12,63 �Ma?!t AM Na ..................... ......... %,� . HIE.NO.: ..... ..... .. ..... .... !i. ELE.NO.: 7 . . -erwltP, 'iAgry J—----- UNAUTHORIZED USE OF THIS �- 11 < .e ' OUTPUT DURING OPERATION • [P0WER,9PT! !ZRCON T M L _ P , 1 RVISSION i ROV CON]RAC 1 Olt IS IN ............. ..... ....... .......................... maximum Outpu V.I!RFi_ 85" Vdc VIOLA]014 01 U.S.COPYRIGIII LM'S It O1UTPUT6IyRFNG STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER M—S&AREDGE INVERTER OFF) AND WLI BE SUBJECT TO CM 1 DAIIAGES AND PROSECUTIDIJS 3 VdI: !jl --------------------IT--- NEV1)VS',,STEK/i: 11.000 IcVVI).. ..ty 'to .. .. . AC IG01IMyetR.HS3 _--------- ------------------- INSTALLATION J .. . ......................1000....... .......... F ............ . ...... dge Single..................Three p.ha,e Marl— ............. 12R..152.27.S/Sx5.97x1.0S ._1:96. 1,77.......... ........ 7SO 5903 YUCCA DRIVE NAL4 I, roRT PIERCE,FL 34982 Input curine'Wr MC4 Compatible "C"C'mta"'a I bauble "plens,.I.Al� APN-340261002910002 -t.r Double Insulated;M 7-, Output Wire Type Con— 424C.mp.nble MC4 1 Double Insulated;IVIC4 Compatible I Arnphl AH4 W 4 ........... ...... ......... _g ............ .......... i ........Operann Temperature Ran a ................ ................... IEEP IPG8 j NEMA6P E1,3GIN Z I DESIGNER ........... .... ............... ..... ....... ............R:.�Pp... ........... ............... 777! -7. .................................... ...... /7Sra , - PV SYSTEM DESIGN SING SINGLE PHASE ........ SINGLE PHASE THREE PHASE 208V THREE PHASE 480V • A SOLAREDGE INVERTER— HID-WAVE String LL�rgth 8 10 is I 71 ............- ............. ............ Maximum String Length (P 1 25 25 so lD PV power optimization at the module-level ........ I..........................................I.........................I..-.. . ............................... X CVC56k67 1 5700(GOW I _��Bpkl"It' 5 50 (SIM 12750 ma.mum P.—I per String 2 CD - Up to 251A more energy ... ... ................ .............. Parallel S[rings of DitTerent Lengths - Superior efficiency(99.59.) ye, .......................................................................... ........... ..................... - Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading tp - Flexible system design for maximum space utilization k bye - Fast installation with a single bolt ow— Next generation maintenance with module-level monitoring S 0S, - Module-level voltage shutdown for installer and firefighter safety DATE: '11001F I I I I CE GRP DESIGN BY:O.S. USA-CANADA GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLAND', UK-ISRAEL-TURKEY-SOUTH AFRICA BULGARIA.,INDIA wY.solaredge.us CHECKED BY: M.M. i ol REVISIONS 6 R-003.00 A 8 113 C LA D LQ E Li F Ed G U H (SHEET 13) A B —r'— C - -�------ --——�-------E-- -- p----F-------—'a—_ G H vinyasun ,®,�. IRONRI®GE Roof Mount System ____ XR Rails --- - -- XR10 Rail XR100 Rail XR1000 Rail Internal Splices O —16 're A GOO TRACTOR u• r- - VINIA UNCORP A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices PHONE: 5614409515 - —for forregions'wittfllght snow.-=solar mounting rail= -=rail-for-commercial•projects,--for=seamless•connections—__ A } S, }3 ATl RA STPLMUITI 101 - 6'spanning capability 8'spanning capability 12'spanning capability Self-tapping screws WEST PALM DEACH,FLORIDA Moderate load capability Heavy load capability Extreme load capability Varying versions for rails 33401 Clear anodized finish Clear&black anod.finish Clear anodized finish Grounding Straps offered LIC.NO.: CVC 56967 HIC.NO.: — Attachments —— — --— - — ELE,NO.: UNnUTHORI7FU USF OF THIS — - - "- — FlashFoot Slotted L-Feet Standoffs Tilt Legs I ry issiv ill M courarL roa r iN 3 » DAMAG' fo es o n No S.COFYRICH in N HE JECT TOCIVIL -t _ IvELV?V SYSTEM: 11.000 IMP ___ Anchor,flash,and mount Drop-in design for rapid rail Raise flush or tilted Tilt assembly to desired J6 "'K "M with all-in-one attachments. attachment. systems to various heights. angle,up to 45 degrees. Ships with all hardware High-friction serrated face Works with vent flashing Attaches direct) to rail "a J� [I } rh�N P 9 9 Y I a@�Ju0,E "E IBC&IRC compliant Heavy-duty profile shape Ships pre-assembled Ships with all hardware gg03 YUCCA DRIVE Certified with XR Rails Clear&black anod.finish Lengths from 3"to 9" Fixed and adjustable Built for solar's toughest roofs. FORT PIERCE,FL 34982 — -- - IronRidge builds the strongest roof mounting system in solar.Every component has been tested to the limit Clamps&Grounding APN:340261007.9i0002 4 and proven in extreme environments. End Clamps Grounding Mid Clamps Q T Bolt Grounding Lugs a Accessories Our rigorous approach has led to unique structural features,such as curved rails and reinforced[lashings,and t E€,tCl1 I CSIvhER is also why our products are fully certified,code compliant and backed by a 20-year warranty. �` ;, r i f Iq ¢r09ESIG iPLI _ . '� It 12 Strength Tested PE Certified — r � • ate ( c All components evaluated for superior Pre-stamped engineering letters Slide in clamps and secure Attach and ground modules Ground system using the Provide a finished and structural performance. available in most states. modules at ends of rails. in the middle of the rail, rail's top slot. organized look for rails. _ :V CD r. Mill finish&black anod. Parallel bonding T-bolt Easy top-slot mounting Snap-in Wire Clips = CVC5B G - Sizes from 1.22"to 2.3" Reusable up to 10 times Eliminates pre-drilling Perfected End Caps Class A Fire Rating Design Software Optional Under Clamps Mill&black stainless Swivels in any direction UV-protected polymer (St 5 Certified to maintain the fire resistance f� Online tool generates a complete bill of _ J r o'f WE ¢ sl rating of the existing roof. materials in minutes. Free Resources to .�� abk7ITE R i T Design Assistant P A NABCEP Certified Training �i r O 11 a Integrated Grounding 20 Year Warranty - - - Go from rough layout to fully vl V Earn free continuing education credits, PATE: engineered system.For free. , > while learning more about our systems. UL 2703 system eliminates separate Twice the protection offered by - D a Go to IronRidge.com/rm � Go to IronRidge.com/training DESIGN BY:O.S. module grounding components. M competitors. _ � CHECKED BY: M.M. REVISIONS na R-004.00 A B C L11D isE uF LdG H (SHEET 14) A r' ---- B �r__ °' __ -----C -- n' 0 --- a E— _ F p —-- G H ,✓i,, IRONRIDGE Susan Marie Jackson 1495 ZEPHYR AVE.HAYWARD.CA 94544 vinyasun PITCHED ROOF e Project Details -- CONTRACTOR NAME Susan Marie Jackson DATE 2017-10-29 -- LOCATION Fort Pierce,FL,34982 TOTAL MODULES 40 I VINYASUN CORP 2 MODULE Canadian Solar:CS6K-275M(40mm) TOTAL WATTS 11,000 DIMENSIONS 65.0"x 39.1"x 1.6"(1 mm x 992mm x 40mm) ATTACHMENT PTS 72 PHONE: 5614409515 — ----- —- - - — —- --- ---- - -- —--. _17"vl�ES3:"F3i)IdURA-GTft€€1=5V. —i 1---_...--- PdEST PALM BEACH,FLORIDA 33401 Load Assumptions Building Details LIC.NO.: CVC56967 WIND EXPOSURE B ROOFSLOPE Odeg HIC.NO.: ELE.NO.: - - - —- -WIND SPEED - 170 mph.__ - BUILDING HEIGHT 30 ft _ _ _ _ _ —_ _ _ _ UNAUTHORIZED USE OF THIS _ - GROUND SNOW LOAD 0 psf RISK CATEGORY II 4 P[QKUSSION FROM CorTRACTOR is ua ATTACHMENT SPACING 4.0ft `E A;4DWILGLATIOLBE UBJECTT CM Inws NJD iMLI DE SUBJECT TO cMt 3 DAMAGES AND PROSECUTIONS. IJE vj PV S,'s'rEM:11.000 IMP Engineering jIA I,K,S,0 , XR100 SPAN DETAILS(Portrait) MAXIt,AU M REACTION FORCES(Portrait) c� l I6e��gPt.$P 1r� Roof Zone Max Span Max Cantilever Roof Zone Down Uplift Lateral �( �DENC", R ES 1 7'2" 2'10'• 1 142.00 -277.00 0.00 5903 YUCCA DRIVE 2 5'4" 2'2" 2 142.00 -515.00 0.00 FORT PIERCE,FL 34982 3 4'3" 1181, 3 142.00 -812.00 0.00 APH'.340261002910002 4 ENGINEER r DESIGNER System Weight �F RECOPIP, TOTALWEIGHT 1830lbs WEIGHTIATTACHMENT 25.4lbs a,, �� ate DISTRIBUTED WEIGHT 2.6 psf RACKING WEIGHT 224.9lbs NCD r CVC56 67 0 _ • ER I� 5 � DAT�/Iy.�012 171I110\\\ DESIGN BY:O.S. CHECKED BY: M.M. REVISIONS 6 Last updated by Justin Hoysradt on 2017-10-29 13:10:53-0700 Page 1 of 6 R_005 r00 A B WC tdD E F LAG H (SHEET 15) A rD------B..—---.._.�r. -- - ----��1. _.._� ---p- - E _---_—a,.___— -F-----c'— G H 495 Phi IRONRIDGE 1495 Zephyr Avenue (1-80ZephyrAvenue vinyasun Hayward.CA 94544 �,� I RON RI DGE Hayward,CA 94544 1-800.227-9523 lronRi ge.cor27 23 IronRidge.com IronRidge.com 9 Attn:David F.Taggart,VP Products,IronRidge Inc. The span tables provided in this letter are certified based on the structural performance of IronRidge XR Rails only with no CONTRACTOR Date:March 281h,2017 consideration of the structural adequacy of the chosen roof attachments,PV modules,or the underlying roof supporting members. It Is the responsibility of the installer or system designer to verify the structural capacity and adequacy of the 2 Re:Structural Certification and Span Tables for IronRidge Flush Mount System aforementioned system components in regards to the applied or resultant loads of any chosen array configuration. 1IIJYASUIJ CORP This code ance of e's Flush Mount System. he Flush - Mount 5 letter temaddr ssae ro rieta s the structural pool operformance fl mountir es stem=usedmo support photovlollttaic-(PV)modulesinstal ed-in-portra t=or-----=--S ncerel ---- �•`�,``GP�,C�', ,4t��e, -_ - - - PHONE 56�44D55 R ;;E! }1'F i3f---.- --�-- Ys P P rY P 9 Y Y gt Dry DAI UR A-S"2 T� landscape orientation and set parallel to the underlying roof surface. PV modules are supported by extruded aluminum :'��C3F•. �% NIEST PALM BEACH,FLORIDA f XR Rails and secured to the rails with IronRidge mounting clamps. The XR Rails are side mounted to a selected roof No 8059933401 -sue; CVC attachment with 3/8"stainless steel bonding hardware and then attached directly to the roof structure or to a stanchion (��"�, that is fastened to the underlying roof structure. Assembly details of a typical Flush Mount installation and its core LIC.NO.: C1+C 56967 =�: ATE OF 'W: RIC.NO.: components are shown in Exhibit FCC-0015. �0� ELE.NO,: 0 1 / UNAUTHDRIZED USE OF THIS The IronRidge Flush Mount System is designed and certified to the structural requirements of the following reference �ONA�r�NO` F Ek:Iss oN ROM eoNlaA oR Is!N standards for the load conditions and configurations tabulated in the attached span tables: Gang Xuan,PE,LEED AP VIOLATION Or U.S.COPYRIGHT LAWS Senior Structural Engineer DAD GESANDPHOSECUTIORS. S I ASCE/SEI 7-10 Minimum Design Loads for Buildings and Other Structures(ASCE 7-10) 2012 International Building Code (IBC-2012) NEW PV SYSTEM: 11.000 I(WI) Florida Building Code 5th Edition(2014)Building 2010 Aluminum Design Manual(ADM-2010) J A C KS SON, The tables included in this letter provide the maximum allowable spans of XR Rails in the Flush Mount System for the respective loads and configurations listed,covering wind exposure categories B,C,&D,roof zones 1,2&3,and roof R E(�a S M E���Cf E slopes from 00 to 450. The span tables are applicable provided that the following conditions are met: 5903 YUCCA DRIVE 1. Span is the distance between two adjacent roof attachment points(measured at the center of the attachment FORT PIERCE,FL 34982 fastener) AM:340261002910002 4 2. The underlying roof pitch,measured between roof surface and horizontal plane,is 45°or less. ENGINEER 1 DESIGNER 3. The mean roof height,defined as the average of the roof eave height and the roof ridge height measured from Of( grade,does not exceed 30 feet. t t t oy D 4. Module length shall not exceed the listed maximum dimension provided for the respective span table and module 5 i� width shall not exceed 40'. ` �\r,ate 5. All Flush Mount components shall be installed in a professional workmanlike manner per IronRidge's Flush Mount m - installation manual and other applicable standards for general roof construction practice. _ N CVC569 7to �o — E-D T dPVTJ-1 l : )211 DESIGN BY:O.S. ®2017 IronRidge,Ina FL Flush Mount System Certification Letter-1 ®2017 IronRidge,Ina FL Flush Mount System Certification Letter-3 CHECKED BY: M.M. REVISIONS 6 R-006.00 qfilB C UD E INF taG LAH (SHEET 16) D -------'E--- -�'---- F-'-- --- -- G H Flush iVlountSystem Span Table(inches) - �/I r1 aSIJ r1 1 * ' Portrait:ln9tallation(Maximum(Module Length 67.5 ) a xi��.. r , 11 »�5, ;� u, •,�saxz�^. �,,.,,,� ;� ..,�°�„".;'. �'' : ,Exposure,B _ Wind Roof Ground Snow:0 psf 10 psf 20 psf 30 psf 40 psf 50 psf 60 psf 70 psf 80 psf s 90 psf Speed Slope LI 2one 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 (mph) (degs.) Zone 1 Zone 2 Zone 3 Zone 1 Zane 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 2one 3 Zone 1 I 104 63 96 98 83 83 I 83 _83 B1 81 81 .73_ __73 f 73 67 ; 67 67 61 I 61 61 57 57 ; 57 54 54 j S4 51_ 51 _ 51 _ : _- 10 ...11fi.,1.104. .....&i._.^ .__96_"...._96_ 84 8i..._r 81, T81. _..80..._L _80 } BO� 70 70 I_ 70"_-. 63 I 63„_-I.^fi3_ .-57_�_ 57..^...__s7T....._�_ f..-..54 ....1 .54 51._. 51 i.._51 _..-.47..i '47.._.�...47 .. __..._. { �_ l 15 135 I 103 83 95 95 83 80 _ __80_"� 80 _ _76 7G 76 67_ _ 67_1_E7__ GO ! 60 GO - 54 54 54 51 51 51 47_�-47 _ 47 __ 45 _ 45 45 --"- -_. -.- _._-.._ ___. _._.-_-i I tt +�--` 1 82 60 { 80 $0 76 76 76 67 67 67 fi0 60 60 95 } 55 1 SS 51- I 51 51 _ 47 47 4745 45 45 (sEl'!li�: fel•o 20 113 101 62 95 ! 95 - _ _-. --_ ,_ , _-_ .. ._ -.- 1 ! - - 110 25 112 _100 82 95 95 ' B2 81 81 81 _ 77 I 77 77_ 66 6$ l 68 61 61 61 56 `_56 - 1 56 52 52 _ 52 _ 48_ 48_ 48 46 46 L 46 ----- 30 110 I10 110 96 96�_96 -62. 82 82___79 79 _ 79 _ 70 JO 70 63- 63 _ 63 _57 J 57 57 - 54 - _ SA - 56- 51 51 51 - 47 -47_ 47 ` 35 _109 109 _ 109 97 97 _ 97 _85 II 85 85 83_ 83 I_ 83 _74_� 74 ! 74 67 _ 67_ 67 61 , 61 61 56 56 56 _ 53 53 -53 s1 Sf sl___ M14YASUN CORP 2 40 108 4 108 108 _ 99..--.i 99 V 59 88 88 -t 88�__87 87 87 78 78 78 _ 71 71 _ 71 _-_66 __66 66 61 __ 61 63_ 57 57 57 _54 7_ 54 54_- L-_. _ -"- 77 85-� -78 I 78 - 78 72 I 66 -66 68 68 68 63- 63 I 63 60-I 60 60 107 j 107 ! 107 102 ; 302 102 B2 92 92 91 91 93 85_.."I- 85fy S I76 99 79 96 98 _ _79 _93 f 83 79_ ,81 j 81 ! 79._ 73__ff-73 _ 73 67- 67 67- __61 61 61 _ 57 __ 57 _ 57 _5A__ 54 54 _ _47 f. 51__-'__51 10 116 .�- 100 -80"" - 96 -96 _ 80 81 Bl 80 $0 ! BO _ 80 70 I- ZO I 607 60- ` 63__, 63 57 57 _I 57_ 54 54 _54 51 51 _I 51 47 -47 47 PHONE: 5614409515 -- 54 s1 51 si 4J a7 ( 47 as a5'" ( as_ -98 _80=_ =95-:_95._._80 -80 806U__ 76_-1 76 - 76 67 67 60 - 60 54 54 _ _ - 20 313 - ...`_B7_ .- 7995 i 95 T 79 80 80_---_ _ .79. ... 76 .. _76 76,..-_, .. 67.__..._67_. 67 60,...{. 60 ._ 60_.�5 _55 5�-51- - sl SI 47_ 49- iv7-..-a5. �45-. ._45 _ _=;0','c.'v`c:..;i3(,.4T<;R�,.o:}:iLl+z LA 1_161_ -- - """ `. 7g 7j j7 77 68_ 68__L 68_ 61_ I 61 _ 61 56 56 - 'S6 ___ 52 � 52 _52 48 48 48 -46 46�46 v�[ST PALM BEACH,FLORIDA 25 112 9G 78 . 95 95 - 78 _ 81 -I ,,81-_. .._._. .. _ _ _ _ _ - - III -_-. ... _....._ .. -- _..-..115 30 107 _I 107 i 107 94 L 94 ( 94 62 +- 62 82 79 I 79 79 70 70 70 63 f 63 63 57 _57 57__ 54 54 54 Si 51 _ 51 _ 47 I 47 47 _ ,_106 T 306 96 9. ! 96 84 1 84 64 _ 83__' 83 83 - 74_ 1 74 74 '_'" 67 ' 67 67 -_ 61 _ _ 61 61_ 56 _56 56 53 53 53 51 51 ! 51 33401 I 86 86 78 76 1 78 71 -_71 - 61 -__66� 66 66 61 61 61 57 57 57 54 i 54 54 - " 40 ]0 305-T 305 98 • 98 - 98 _87 - 87 87 86 - - 105 'i- f04iY04 f00- i 100 -I_-100 90 1 §0 1 90 90 } 90 96-- 84'- I $4 I---"84 5$ 76'- 78 72` ': 72 72--' `68 6'8' -68 63- "" 63 �. fi3 "- "60 60 - "fi0 LIC.NO.: CVC 56967 I S-- 5 118-f_ 95 _76 98 95 76 63 83_ 76 81 ( el 76 73 73 I 73 E7_ G7-I 67 _ fil _ 61 61 57 57 _ 57 _54___ 54 54 51 51 51 10 ^116 I_96 _77-_ 96 _L.. 96-1,77 81.-_1 81___ 77 __ BO_ 80 77 70 _ 70_�" 70 63 ! 63 _ 63 -57 ,_'S7 57 _54 54 _ 54-_- 51 51 _ 51 _ 47 47 47 _ _ 35 _115�i 94 76 _95 94 I 76 80 80 76_ -7- 76 r`76-_ _ 67 67_ 67 60 60 60 54 54 _i 54 _ 51 _51_ 51 47_ 47 47 45 1_ qs as E E,NO.: ---- -- -L` -2U - 113 93 -76=---95 93 - -76-- 80 60-- --76 76 _.!--Z6 76 67_ 67 I 67 60__.;_-.60 60 -55 55 SS 55 51 i_51 51 47_ A7 C7_ 45 45 I 49 UNAUTIIORIZFDUSEOF THIS 120 25 112 92 .75_ _ ___95 92 75._-. Bl _81_ _75_,.._ ??_ .L__77 ..75_ 68 68 { 68 61 61 61 56 56 56-- 52 52 -S2 48 _.. 48 - 48 46 46 -46 b`:,�t T -!'K'I- TT''. - - - ! 79 70 70 70 63 63 63 57 -i 57 - 57 54 !, 54 S4 51 51 51 41 1 47 47 PFk AISoIJN FRO,d GON1LACli HI51�: 30 104 : 104 304 93 93 93 __. 81 ._ 61-: 81_-79 I ],__ 9 ��,. ___.__-,. __.__._ -__ _.-_- -.--------- - _ - �__ 35 _103 303 103 9d 94 _-,-___94„ ___-63 -- ---_83__,- -83_____,B2_-{-_82_ ,82,- 74 --"- 74 74, .. _67, 67, "_ .67 „- __,61,_ �___"61 _ 61 56 - S6 56 SS 53 _ _ 53 _ S3 6]_ 51 VIOLn11JN 0f U.S.CO°YRIGtII LgNp - ---'-- "-"' 85 78 78 _ 78 ",-_71_ _ 71 .__71` _66 6666 _ 61 "--61_ 61 57 _ 57_ 57 _ 9d }__34 54 ANDIMLL BE SUBJECT TO CIVIL i 302 102 _ 96 1 96 4 96 86 B6 86 85 ( BS - _ 40 303 j J 102 i 301 16i 98""I 93 I 96 89'��- _ 8�- f 83 7$� -78 T 78 72 ';---J2 -'!---72 68 68 6$ 63 63 163- --60� 60� DAF'�P,GE6 AND PROSECUTIONS. 7 98 70 83 83 70 81 81 70 73 73 1 70 -67_ i 67 67 63 ; 61 61 57 57 57 54_ 54 I 54 _ 51 51 I 51 5 _ 115 1 87 0 .. 87. .. .. I .. .- ,... .... .. 1._..... - _ _ _ I 10 136 �_. -SS_-Ij71 ... 96 7. 88 - 71 - B1 r 81 ! 71 8- l 80 .__ 71 70 70 _`_ 70 fi3 _ 63 -- 53 __V. i 57 -- 57 _ _ 54 54 _ _ 54 51__ _ 51 51 47 _ 47 ! 47- p C i 15 _ 115 _L 87_.!_ 71_ _95 _87._�_71_-R80 - BO 71 _-_ 76I. J6 71 - 67 -"--67 I' 67 60 j 50 "_ _60 54 I 54 54_ 51 51 51 47_-, 47 � 47 -45 45�_ 45 I�EI�I!17 SYSTEM:EM:11.000 Id�(p 20 113_ I 86 ( _70 95 86 70 _ BO 1 80_� 70_ 76 76 70 _67 _ 6 7 _I_ 67_ 66 __ 60 _ 60 _ 55_ 55 55" 51 _ 61 _ _51 47 47 47 45 _45 45 130 ZS 112 85 70 95 85 70- 81 81 70 77 77 70 68 68 68 61 Cl 61 56 - 56- 56 52 52 ; 52 48 48 48 46 rt 46 46 A ._.. ..... ... ..... .. 79..... .._.79 _ ." 77 7.- ..77 ! 77.... .70 70...f....70 ..fi3. 1 63... ..63... .57 57 .. ...-57.. 54 .. 54.. .54 51... .-.51 $1 ...-.47 47_ _47- -}j I1 n.- 30 _ 99 9$ 98 90 _ 90 90 79 I .__...._._......._._...............L....."."_ _.._"""_._"._.__""-_..._,_....____...._.-_.."__..-.._....-.-......_.._.._.."."._"_._.__._'._....._.._..-...__________"_._..._.+.......""_...__I"._.._-_._"....-._._...._(.""_._.___.....__ _ _ (JA K C,0 B U 33 98 97 _ 97 91 -I 91 - 91 81 81' 81 80 BO ' -BO 76__ 74 -74___ 67 _67 67 _ 61 1__6i _61 56_ _ 56 __ 56 53 53 _ S351 51 51 4U zs_ 97-" I 96_ 96 93 -} 93 -_,_83_ _ 83 � 83 62 ` --82�_82„ 77 _ _ 77 f _77 71 71 _-_71 -66 __66 65_'"-61 61- 61 57-�-I� -a- 57 'S4 -54 11 97�i 95 '�93 95 95 B3 86 _66.._ 65 -$783 B6 91 61- 93 7G.- . 7fi-. _72 T 73 ,._'72."�_ 68-. 68 5$' S4 .'1._-._54 63 7i0 6d- 0 I_ f1�71;1� �l,f L ' s 107 81_ 65 98 81 65 83 !_ 65 73 73 _ 65 _67 ' 67 65 61 61 61 _57_1 57 _ _ 54 51 _ 51 _� 51 f \, �j L FFL�11 @@ E ' --__� -- 8 -- _^66"-"--BO 80 f 66 70 70 66 63 63 _"_fi3__- 57 57'-�-_57 54 _ 54__-; 54 51 si 51 -""49 47 47 10 111 ! 82 66 96 82 ; 66 81 I 81 -- --- -- --.... �._-..� .-�_.._._- ---.-.- 81 66 80 80 _! 66 76 76 ! 66 67 I 67 , 66 60�. _60 60 54 __SA- 54__ 51,._ 51 j 51 _ 47 47 1 47__ _45 45_ 45 15 309 81 95 _ _. _I - "- 55 _'_ 67 I 57 _) 65 -50 60___ -60 55 55 55 K-7 _- 51_I_ 'S3 47- j '47 47 _45 45__ t- d5- 5003 YUCCA DRIVE 20 107 _$0--� 65 95 _ 80_ I 65 80..,,_I .80 _ _65. ..76.- -77 -__65. - -68-I 68 _-_ _ __ _ _ _ _ _ _ __ _- _ 1 _(}n-' - ,p 140 25 306 -86 __ 65 _ 95 _IBD I65 81 BO 65 77 i 65 61 61 61 56 56 56 52 t4 52 52 48 i 46 T 48 46 46 �- 46 0 94 .-, 92 -92 - ,_87 ,-87 �I_ 87 --77_ ,-I-7l___ ?_ 77 76 _-i_76 i_ 76_ 69 69 , 69 63 63 _ 63 S7 - -57_ _57 54 50 r 54 -'S1 51 T 51 _ 47 47 47 - FORT PIERCE,FL 3��82 35 93 91 91 88 88 88. 19 1 79 -t 79 _ 78- 78 ,- 78 _72� 72 I- 72 �--�-67 67._ 67 61 61 61 56 � 56 56-- . 53 .1. 53 53 - _ 51� 51 i A,-' I.3402610O.Lnn ._. ..... _.. .._ .. ....... ..._.. ... 9 I0002 - 4. I 7 57 54 64 54 40 93 t 90 ..-.._90.---'---90...,_.__.90._....'...._90.-......_._81 ...-_._81.".__r...._81..._......_eR...._!-..-_80.....;.._._BU._...__-76.......L."_.76............_76..._....__.7�._._�-._-_ZP.."."_._....��--...._ �__.".._."_G6..-. ._71 61 I '61 t-61 57 ..5 __.. -.. _. ...._-_I.._ -`'__........-"""`` + $4 84 I 84 $3 83 $8 79 79 Y9 75 I 75 75 71 71 71 68 I 66 68 63 " 45 92 T 69 I $9 91 $9 I $9 63 1 63 60 60 I 60 ' 75 ' 60 73 73 60 _ 67 67 60 61 61 60 57 57 -57 54 I 54 54 51 53 I 51 60 81 _ 4 5 300 j 75 L 60 96 75 60 83 75 51 47 47 I 47 ' 2 96 76 •-62 81 76 �66 -� 79 76 ! 62 _70__ _.70.--_--„_-„b2_- 63. 63 62 57 57 57 54 54 I 54 51 I_ -51 __ - 30 104 t 76 1 6 1 02 1 76 62 95 76 62 80 76 62 _76 _y _76 _j-__-_62 -67- .-67 -_-_62_-_ -60 60 60 54 54 54 51 51 51 4T 1 47 47 _ 45 45 ENC,-INFER r DE ���v�R 1 .___...__......-..._. 20 101 75 61 95 75 61 80 I__75 61 76 ' JS ' 61 67 67 1 61 60 GO 60 _ _ _ _ _- - --tt ' _..._.__....____5-------------- 55 55 55 51 53 51 47 47 47 45"- -45 J 45"" 1S0 25 99 IS 61 95 I 75 61 81 75 61 n f 75 i 61 68 68 61_ 61 61 Gl 56 56 56 52 52_I_52 48 � 48 h 46 -4G 46 j �� _ `\k\�,� 30 89 86 _ 86 __84�_ 64,_. 75- 75 1 75 74�_ 74 74_ _ 68 _66 _-_68 63 63 _63 _ 57 57_ 57 _54 _=54 -( _54 51 51-I 51 47 47 _ _ Y-\- 35 -89 85 t{ 85 85 .85- 1- 85 77 77 1 77 _76 76 -76 70 _ 70 1 _70 fi6 66 66 _61 61 6i _ 56� Sfi 96 53 53 53 51 40 ".BS I 85_ 87 1_-__85 �85 79 79 l 79 78 __-_78 „_..78 74 74 T-""_74 -..69 69 .__ 69 -_.66-- - fi6 66 61 61 61 57 57 j -57 54 54 54__ \\�c •• �,a 0 - t i � . -'g6 f Bd- i 84 88 } 84-- 84 BS -61'"`1 $1 - 91' ! 91 8i' 77 7J i 17'- 74 14 74 -70 70 ]0- 67 67 ---67, f;3'- - 63-'9 63 "' 60 '60 ( 60' - 5 93 I 70 57 93 57 83 _` 70 57 _ 81 1 70- 57 73 70 57 67 67 57 61 _61 57 _57 57 I 57 54 I _54 1 54 _ 51 51 + 51- '\fiat 10 97 72 _,,58_-___ 94. -1_--72 ) 58 79 72 1 58__ _,78- 72 58_ 70_ _70 S8 LL - 63_ 63____._58 57 57 57' S4 _54 -56 51_ 51 51 _47 _ 47 y 47__ •\� 35 96 r 71 58_ 93__I 71 58 79 71 58 ]6 �-71 T 58 67 67� 58 60 GO __ 58__ 54 54 58 51 51 51-_ 47_ 47 _ 47_ 45 45-_ ` 45 t� 7•• 20 _95 I 71 -` _58 93 µ.-71 58 79 I 71__ 58 76_ _71 ! 58 67 67 I 58 60 60 58 `- 55 55�_ 55 51 5151 _ 47 47 47 Y�45 _ _45 45 �1 •• 25 94 ' 70 57 93 _70 I 57 79 I 70 57 77 I_ 70 _Si 68_ 68 I 57 _61 61 57 56 56 56 52 __ 5252 46_ 48_ 1 48 -46 46 46 V ' 160 -- ----__-`- -- }_- 81 _ -73 73'T-73-- 72 1 72 72 67 67 67 62 62 62 57 57 57 56 54 1 56 51 _ 51 51 47 47"� 47 `' - 30 85-L_ 81 81 82 I el _ - ..__,�__._ --_..-._._-,�___ ._._-__- __�-�t1 .-. -_....-_-.._- .}-._-_ _I- -�- _ .1.-.---_ - _ "-`- 1 75 5 75 74 74 74 69 69 I 69 64-{ 64 64 61 61 61 56 56 56 53 uJ 56 53 5_1 51_ _51_ 35 85 81 81 83 81 81_ ..""_75- .T. -... ..."_."" 4._...-___. ___....___-:.-.._....". 1...."..."."_._._. __ -_ _ _..1_."....__-.-_""___......_...__._..__.._.___.._ __ -_ _ _ __ _ __ _- 80 80 84 , 80 80 77 77 ! 77 76 76._ _-_."__16."......,--7Z..._..___ZZ_.._1....-.7Z...""...-68_.........._1"..."....._66 64 _64 64 61 61 61 '..57 ! 57 57 54 54 54 V t -t{' CV 5 40 --- ..._-......19. .....7§._._........�..... 10 L_...-79....... 75 7f I >2 72 Eg._i Eg.......{......_6.9..._....--66..._..I_...... I_- -L . ...... t.-_...7§_-........78_-l...__78 i 78 15 7E d6....._�...--- -- 62.......T.-..--63---1 62 EO d0---1 45 __'___66_ l_ 53 ___88 66_ ! 53 B3 6 53 Bl II1 66 i 53 73 66 1__53 67 66 _._53 __61__ 61 53 57 57 53 54 54 53 .51 _ __51 _ 51 j N f 17j)• ` \ 5 _... ...._l - - - --- .. . .. - t 54 51... si-'� 51 47 47 47 10 92 67 I -"55 92 ^1 67 - 55 78 '67 55 77 67 I 55 70 67 55- 63 63 55 57 57 55 5a 54 15 91 67 54 91 t 67 54 - �77 67 I 54 76 67 _ 54 -67 67__ f 54 60 60 54 54 54 54 51 51_ I 51 47 47 47 _45 _45 45 r3�'1tt;;G C�,I 20 ._..._67 _.....54_ - 90-_ -67 .+- 54 --... 77' '--67 I". S4........ 76 _.67.._... 54 ...61__._ 67 _(E(...-54-_ 60- - ..54...._ 55 55 54 . 51 51 -1-51 47.. ( 47� 47 45 45 45 �j •RCE•D R�I 1 10 25 ._-88 _Jf.__66...__.___ __:..- _.._.Jf4-__66.f___ ___...78__.....__66..__ 71__-._��___I•.._70_...,-__ _-.- ..-_66-_f. 54_-._61.._...-61......_54.__..__56.__ __56.._ .. 54 ...-52... . .52-�_52 48 48 1_ 48 _ _4fi.... q5 U(� 30 8-1 I 77 77 79 I-77 I 77 71 71 ! 70 _ 66 66 : 66 61 61 61 57 57 57 -54-- -'-54 54- 51---i''S1 S1 47 47 47 35 81 1 76 76 80 1 76 ' 76 73 73 73 72 72 ! 72 _68__ 68_ _____6f3 _ 63 63 53 60 60 60 _56_ 56 56__ 53 53� 53 51 51 , 51 _ )) 40 81 I_ 76 76 81 76�-76 _74 74 {� 74 �74I_ 74 i 74 70_ 70- _70__ 67 67 _67- 63 63 63- 60 60 }- _60 _57 y 57 57 54 54 sa_ GATE: 1E.�D120101 80 } 75 75 BO 75 75 7J 1 75 1 75 76 I 75 i 75 73 73 73 70 70 70 67 67 67 54 64 64 62 62 62 60 60 60 - 62 1 50 63 �62 �50 83 I 62 I 50 81 ! 62 50 73 I 62 50 67 62 50 61 61 50 57 57 50 54 54 s0 51 51 w DESIGN BY:O.S. 83 10 87 I 66 s2 87 -------------_--$--_._ _ 76_-__63__�_-52_--75,_ _63_._:_"_52_. _.67 _. _63.-...__.•'..2. .__60 60 52 54 54 _52_ ._._51-.__51--{_.51.___v47__�- 87-.__I�-47 _45 45 I 45 -- - ).... - �- - - - -- --- - --- CHECKED BY: M.M. 20 ___85 I63 S3 _85.. {63 _...51 7fi 63 51 _75_�.__.63_ S1 ..._67."_.. 63._._.__51.___.._ _._."_.._ .__.._._..51.........__.`ts_.._._._55......_..._.rtl...__...._51- _ 51__ ___51__ _47 I____47 47 45 45 45 180 25 Bd 63 51 64 63 1 51 77 63 51 75 63 51 68 63 51 61 61 51 56 56 51 52 --52 --• 51 -- -48-'-1 48 48 46 46 46 30 78 __73 _ 73- 77-_--_--"73_--_-------73"___-,_,69 1 69___ ___69 69 69r 69 64 64 6d 61 -61 _ _61 ._56 _- 56_ -- 56 _-54 ,_- 54 _ 54_ 51 _51 1 _51 47 47 -_d7__ _-- -- - - -- - REVISIONS 6 35 77 -73 _ 73 77 73 73 71 71�I 71 70 70 70 66 66 I 66 62 62- _ 62 59 59_ 59 _ 56__-56_ __56 _ 53 "} 53�- 53 _51 51 51 -_- 40 77_ 1, 72 72 _72 77_ 72_-1-_72 -_ 1; I- 72__-I 72...._--_-72 I 72 _ _72 _ 68-_ 68 68 66 _66___-_ 66__ __ 62, ,"_62 -_62__.._.59 59 �___,59 56 56 _I 5G 54 54 Sa__ 75- 77 - 72 72-" 77��72 1 72 74 T -"72' r 72 74 I 72 72 71 71 -71-' '68 68 6$ 6$" 6E 66 63 63 63 _ dl 1 61� 61'-- ""59....., 59_ 59 R-007.00 A ' D UllC D L3E F G LAH (SHEET 17) 1. NEC CODE COMPLIANCE REPORT 1.2.WIRE,CONDUIT,AND OCPD CODE COMPLIANCE VALIDATION 1.1.MAXIMUM SYSTEM VOLTAGE TEST 1.2.1.#1:DC CIRCUIT CIRCUIT:SERIES STRING OUTPUT TO INVERTER 1.1.1.SOLAR EDGE INVERTER W140 CANADIAN SOLAR C86K-275M(275W)S CIRCUIT SECTION PROPERTIES E.MINIMUM REQUIRED EGC SIZE 12 AWG SEETABLE250.122ANDARTlCLE690.45(A) I -- ARRAY PROPERTIES NEC CODE VALIDATION TESTS CONDUCTOR 12 AWG PV WIRE COPPER EQUIPMENT GROUND 6 AWG BARE,COPPER THE SMALLEST EGC SIZE ALLOWED BY TABLE 250.122 IS 12 AWG. VIIJYkSUN CORP 2 CONDUCTOR EGC ACCORDING TO ARTICLE 69OA5(A),IT IS NOT NECESSARY TO ARRAY TYPE DISTRIBUTED MPPT SYSTEM PV SOURCE CIRCUIT MAXIMUM VOC MUST PASS OCPD S NIA INCREASE EGC WHEN CONDUCTORS ARE OVERSIZED FOR INVERTER ARRAY NOT EXCEED 600V VOLTAGE DROP CONSIDERATIONS IF THE CIRCUITS ARE PV PHONE: 55i44D3 15 SYSTEMDESCBI2IlON -_-SOLAR-EDGE-INVERTER W/40 RACEWAY FREE AIR SOURCE CIRCUITS. CANADIAN SOLAR CS6K-2754—— 41:66V<600V=TRUE-- --- —- _ - LOWESTTERMINAL- _ 275W DC OUTPUT CIRCUIT VOLTAGE MUST NOT. PASS TEMPERATURE RATING ! --niivitE ,ivATUitnSfleEL �ulT�i��— NEC CODE VALIDATION TESTS I WEST PALM DEACI I FLORI A MODULE CS6K-275M 275W MAXIMUM WIRE TEMPERATURE 54.8°C 33401 EXCEED 600V CJI HIGHEST NUMBER OF MODULES 1 POWER SOURCE DESCRIPTION STRING OF 20 SOLAR EDGE P320 400V<600V=TRUE POWER OPTIMIZERS,EACH SYSTEM MUST MEET REQUIREMENTS FOR PASS LIC.NO.: CUC 56967 IN SERIES IN A PV SOURCE CIRCUIT CONNECTED TO A CS6K-275M NOT HAVING SERIES FUSE(ARTICLE IIIC.NO.: DESIGN LOW TEMP. 3.2°C 275 PV MODULE 690.6(B)(2)) ELE,NO.: -- - MODULE VOC - - 38.3V - - ________ POWER SOURCE RATED 15A __ THIS DC SOURCE CIRCUIT UTILIZES MODULE- UNAUTHORiZEU USE OF TH!s TEMP.COEFFICIENT VOC 0.119V/C -CURRENT — - LEVEL POWEROPTIMIZERS-THATPROVIDE :" rvrir�iti irrit POWER SOURCE RATED 400V INTERNAL CURRENT LIMITATION AS DESCRIBED IN k I i K e ISSION FROM CONTPACI OR is IN VOLTAGE NEC ARTICLE 690.8(B)(2).THESE DEVICES HAVE I Vi01A1101J aF Us.cOPYmci n uws NEC Code Calculations MODULE SERIES FUSE RATING 15A BEEN CERTIFIED TO PROVIDE ZERO BACKFEED 1 DAM GE BE SUBJECT U 01S 3 CURRENT TO THE PV SOURCE CIRCUIT,AND ZERO UAiaaces ruU PROsecunews. TOTAL NUMBER OF SERIES 2 A.MAXIMUM VOLTAGE OF PV 41.66V STRINGS BACKFEED CURRENT TO THE REST OF THE STRING. NIBN PVSYN• STEM: 11.000 I;Wj) SOURCE CIRCUIT SEEARTICLE690.7(A)AND ARTICLE6907(AJ NEC Code Calculations CONDITIONS OF USE AMPACITY MUST BE PASS JAC KSO N NEC ARTICLE 690.7 REQUIRES THAT IF THE PV MODULE A.CONTINUOUS CURRENT 15A GREATER THAN OR EQUAL TO THE �k MANUFACTURER PROVIDES A TEMPERATURE COEFFICIENT OF CONTINUOUS CURRENT(ARTICLE 100) � OPEN-CIRCUIT VOLTAGE,IT MUST BE USED TO CALCULATE THE SEEARTlCLE 100 I I EE S�0 P I`1 C° 30.4A>=15A=TRUE gtt_-�� k 1! vim'� PV ARRAYS MAXIMUM SYSTEM VOLTAGE.IT INCLUDES AN THE CONTINUOUS CURRENT OF THIS SERIES STRING OF POWER BASE AMPACITY MUST BE AT LEAST 125%OF PASS INFORMATION NOTE RECOMMENDING THE USE OF THE ASHRAE OPTIMIZERS IS EQUAL TO THE RATED MAXIMUM OUTPUT 5903 YUCCA DRIVE 'EXTREME ANNUAL MEAN MINIMUM DESIGN DRY BULB CURRENT OF THE OPTIMIZER. CONTINUOUS CURRENT(ARTICLE 215.2(A)(1)) n TEMPERATURE'ASTHE DESIGN LOWTEMPERATURE.USING RATED MAX.OUTPUT CURRENT OF OPTIMIZER ISI5A 40A>18,75A=TRUE P�iN1 PIERCE,FL34o 82 THESE VALUES,THE MODULE VOC(36.3V)WILL INCREASE TO BASE CONDUCTOR AMPACITY AT THE PASS AP N:340261002910002 41.27V AT THE DESIGN LOW TEMPERATURE(-3.2°C). B.BASE AMPACITY 40A TERMINAL TEMPERATURE RATING MUST 4 (-3.2°C-25°C)X-0.119VIC+38.3V=41.66V SEE TABLE 3f0.17 EXCEED 125%OF THE CONTINUOUS THE TOTAL VOC FOR THE STRING IS 41.66V. BASE AMPACITY(30°C)FOR A COPPER CONDUCTOR WITH 90°C CURRENT.(ARTICLE 110.114(C)) %IdGINEERlDESIGNER 41.66V X 1=41.66V INSULATION IN FREE AIR IS 40A. 40A>=15A X 1.25=TRUE 11111II �(�(A���,.PRD B.MAXIMUM VOLTAGE OF DC OUTPUT 400V EGC MUST MEET NEC REQUIREMENTS FOR PAS \ n Oy 7 CIRCUIT C.CONDITIONS OF USE AMPACITY 30.4A MINIMUM SIZE(TABLE 250.122) \�� ��..• SEEAR7lCLE690.7(CJ SEE TABLE31015(BJ(2)(A),TABLE310.15(B)(3)(AJ,ANDARTICLEf00 6 AWG>=12 AWG=TRUE k�(,ate �jC THE TEMPERATURE FACTOR FOR 90°C INSULATION AT 55°C IS �� l0�•• NEC ARTICLE 690.7(B)REQUIRES THAT ALL PV CIRCUITS HAVE A 0.76. , EGC MUST MEET NEC REQUIREMENTS FOR -PASS VOLTAGE THAT DOES NOT EXCEED 60OV.THIS SYSTEMS DC PHYSICAL PROTECTION(ARTICLE 690.46) OUTPUT CIRCUITS ARE FED BY SOLAR EDGE P320 DC-TO-DC THE FILL FACTOR FOR CONDUCTORS IN FREE AIR IS 1. _ X (D THE AMPACITY DERATED FOR CONDITIONS OF USE IS THE 6 AWG>=6 AWG=TRUE CVC56 67 o - CONVERTER OPTIMIZATION DEVICES.EACH DEVICE IS PRODUCT OF THE BASE AMPACITY(40A)MULTIPLIED BY THE - CONNECTED TO A SINGLE CS6K-275M1(275W)PV MODULE.THE TEMPERATURE FACTOR(0.76)AND BY THE CONDUIT FILL - 5 VOLTAGE OF THIS CIRCUIT IS REGULATED BY THE INVERTER AT FACTOR(1). IJI� f�f P S c,fl'19 IC: A CONSTANT 40OV. 40A X 0.76 X 1=30AA % f � 0, ES RC ENT D.AMPACITY AT TERMINAL RATING 35A i SEEARTICLE 110.114(C) 1 D#T)11p.JA20171 i THE LOWEST TERMINAL TEMPERATURE RATING FOR THIS DESIGN BY:O.S. SEGMENT IS 75°C. THE BASE AMPACITY OF THIS CONDUCTOR AT 75°C IS 35K CHECKED BY: M.M. REVISIONS 6 R-oOVQ .00 A B C D uE L3F G H (SHEET 18) A 1a B C 0 H 1.2.2.92:INVERTER OUTPUT:INVERTER TO UTILITY DISCONNECT 1.2.3.#3:UTILITY DISCONNECT OUTPUT:UTILITY DISCONNECT TO POINT OF CONNECTION I CIRCUIT SECTION PROPERTIES G.MINIMUM RECOMMENDED 0,75"dia. CIRCUIT SECTION PROPERTIES G.MINIMUM RECOMMENDED 0.75"dia. CONDUIT SIZE CONDUCTOR BAWGTHWN-2 COPPER CONDUCTOR 8AWG THWN-2 CONDUIT SIZE COPPER _ EQUIPMENT GROUND 6 AWG THWN-2,COPPER SEEARTlCLE300 f7 SEEART/CLE300>7 �- EQUIPMENT GROUND 6AWG THWN-2,COPPER � C,O>�f'I'IL'�CT®�` CONDUCTOR EGC THE TOTAL AREA OF ALL CONDUCTORS IS 0.16051N2.WITH A CONDUCTOR EGC WITH A THE TOTAL AREA OF ALL CONDUCTORS IS 0.1605IN'. _ OCPD S NIA MAXIMUM FILL RATE OF 0.4,THE RECOMMENDED CONDUIT OCPD S 40A MAXIMUM FILL RATE OF 0.4,THE RECOMMENDED CONDUIT RACEWAY 0.75"DIA.EMT DIAMETER IS 0.75. RACEWAY 0.75"DIA EMT DIAMETER IS 0.75. _ _ VINYASUN CORP 2 LOWEST TERMINAL 75°C pT DESCRIPTION SIZE TYPE AREA TOTAL LOWEST TERMINAL 75°C pT DESCRIPTION SIZE TYPE AREA TOTAL TEMPERATURE RATING TEMPERATURE RATING MAXIMUM WIRE TEMPERATURE 32.8°C Y AREA MAXIMUM WIRE TEMPERATURE 32.8°C Y AREA PHONE: 5614409515 POWER-SOURCE DESCRIPTION`SOL-AR'EDGE'SE760aH=US -2=CONDUCTOR-BAWG-THWN-r-11Y)3661N'OW7321N'= POWERSOURCE DESCRIPTION=SOLAREDGESE7600H-US -2=CONDUCTOR&AWG-THWN-2=0.0366110-OA7321N'- 760OW INVERTER 1 0UF t5 3UATUKA �IiE 5U1T�1fY 760OW INVERTER 1 NEUTRAL 8AWG THWN-2 0.03661N' 0.03661N' 1 NEUTRAL 8AWG THWN-2 0.03661W 0.03661N' 'NEST PALM BEACH,FLORIDA j POWER SOURCE RATED 32A POWER SOURCE RATED 32A 1 EQUIPMENT 6AWG THWN-2 0.05071N' 0.06071N' 33401 CURRENT 1 EQUIPMENT 6AWG THWN-2 0.05071W 0.05071N' CURRENT POWER SOURCE RATED 240V GROUND POWER SOURCE RATED 240V GROUND LIC.NO.: CVC 56967 VOLTAGE 14 1 0.1mm VOLTAGE q 1 10.1605IN' HIC.NO.: INVERTER MAX OCPD RATING 140A s 0.16051N'!0.4=0.401251N'(CORRESPONDING TO A DIAMETER ELE.NO.: 0.16051N'10.4-0.401251N CORRESPONDING TO A DIAMETER u A _ _ _ (_ NEC Cod_e_Calcule_tlon_e_ _- - OF - --- ---- - -- - - - - - Nun INFO USE OF THIS ioR NEC Code Calculatlons OF 0.75') 6" ulajuvn IiWlilualWRIT1l:N A.CONTINUOUS CURRENT 32A rEPIAISSION FROid CONTIIAOTOR IS IN NEC CODE VALIDATION TESTS I ViOLATIONOFU.5.COPYRIGHTLAWS A.CONTINUOUS CURRENT - 32A NEC CODE VALIDATION TESTS SEEARTICLEWO. ANOWuOE SUBJECT TocML 3 SEEART/CLE J00 a UAVAGES AND PROSECUTIONS. ` OCPD RATING MUST BEAT LEAST 125/o OF PASS EQUIPMENT MAXIMUM RATED OUTPUT CURRENT IS 32A OCPD RATING MUST BEAT LEAST 125%OF PASS EQUIPMENT MAXIMUM RATED OUTPUT CURRENT IS 32A CONTINUOUS CURRENT(ARTICLE 215.3) CONTINUOUS CURRENT(ARTICLE 215.3) N E1N PV SYSTEM: 11.000 kVVp 40A>=32AX125=TRUE B.BASE AMPACITY 55A 40A>=32A X 1.25=TRUE B.BASE AMPACITY 55A CONDITIONS OF USE AMPACITY MUST BE PASS SEETABLE310.16 CONDITIONS OF USE AMPACITY MUST BE PASS JAC���. O l SEE TABLE310.16 BASE AMPACITY(30°C)FOR A COPPER CONDUCTOR WITH 90°C BASE AMPACITY(30°C)FOR A COPPER CONDUCTOR WITH 90°C GREATER THAN OCPD RATING,OR RATING GREATER THAN OCPD RATING,OR RATING INSULATION IN CONDUIT IS 55A. OF NEXT SMALLER OCPD(ARTICLE 240.3) e� INSULATION IN CONDUIT IS 55A. OF NEXT SMALLER OCPD(ARTICLE 240.3) 52.SA>=40A(OCPD RATING)=TRUE 52.8A>=40A(OCPD RAT€NG)=TRUE R 1' %P[ I 4 C.CONDITIONS OF USE AMPACITY 52.8A C.CONDITIONS OF USE AMPACITY 52.8A162.8A>=32A=TRUE CONDITIONS OF USE AMPACITY MUST BE PASS SEE TABLE310.f5(B)(2)(AJ,TABLE310.15(BJ(3J(AJ,AAIDAR77CLE 100 CONDITIONS OF USE AMPACITY MUST BE PASS 5903 YUCCA DRIVE ` SEE TABLE31015(8)(2)(A),TABLE3f0.f5(BJ(3)(A),AND ARTICLE 100GREATER THAN OR EQUAL TO THE THE TEMPERATURE FACTOR FOR 90°C INSULATION AT 32.8°C GREATER THAN OR EQUAL TO THE FORT PIERCE,FL 34982 THE TEMPERATURE FACTOR FOR 90°C INSULATION AT 32.8°C CONTINUOUS CURRENT(ARTICLE 100) IS 0.96. CONTINUOUS CURRENT(ARTICLE 100) 0 IS 0.96. THE FILL FACTOR FOR A CONDUIT THAT HAS 2 WIRES IS 1. 52.8A-32A=TRUE AlI N:3402.61002910002 4 THE FILL FACTOR FOR A CONDUIT THAT HAS 2 WIRES IS 1. BASE AMPACITY MUST BE AT LEAST 125°/a OF PASS THE AMPACITY DERATED FOR CONDITIONS OF USE IS THE BASE AMPACITY MUST BE AT LEAST 125%OF PASS THE AMPACITY DEBATED FOR CONDITIONS OF USE IS THE PRODUCT OF THE BASE AMPACITY(55A)MULTIPLIED BY THE CONTINUOUS CURRENT(ARTICLE 215.2(A)(1}) PRODUCT OF THE BASEAMPACITY(55A)MULTIPLIEDBYTHE 50 TINUOUSCURRENT(ARTICLE215.2(A)(1)) TEMPERATUREFACTOR(0.96)ANDBYTHECONDUITFILL rENIGINEERIDESIGNER TEMPERATURE FACTOR(0.96)AND BY THE CONDUIT FILL 55A>40A=TRUE FACTOR(1). 55A>40A=TRUE FACTOR(1). BASE CONDUCTOR AMPACITY AT THE PASS 55A X 0.96 X t=52.BA BASE CONDUCTOR AMPACITY AT THE PASS L�t`_� ��s 55A X 0.96 X 1=523A TERMINAL TEMPERATURE RATING MUST TERMINAL TEMPERATURE RATING MUST S/. i - EXCEED 125%OF THE CONTINUOUS D.AMPACITY AT TERMINAL RATING 50A EXCEED 125%OF THE CONTINUOUS GJ d i SEEAR77CLE1/0.114(CJ CURRENT.(ARTICLE110.1t4(Cj) J•:I`�ate D.AMPACITY AT TERMINAL RATING 50A CURRENT.(ARTICLE 110.114(C)) �� SEEAR77CLE 110.114(C) 50A>=32A X 1.25=TRUE THE LOWEST TERMINAL TEMPERATURE RATING FOR THIS 50A>=32A X 125=TRUE t�- 7 THE LOWEST TERMINAL TEMPERATURE RATING FOR THIS EGC MUST MEET NEC REQUIREMENTS FOR PASS SEGMENT IS 75°C. EGC MUST MEET NEC REQUIREMENTS FOR PASS :V N �- SEGMENT IS 75°C. MINIMUM SIZE(TABLE 250.122) THE BASE AMPACITY OF THIS CONDUCTOR AT 75°C IS 50A. ) - C C5 967 ° - THE BASE AMPACITY OF THIS CONDUCTOR AT 75°C IS SOA. MINIMUM SIZE(TABLE 250.122 _ 16AWG>=8AWG=TRUE E.MINIMUM ALLOWED OCPD RATING 40A 6AWG>=8AWG=TRUE V - E.MINIMUM ALLOWED OCPD RATING 40A CONDUIT MUST MEET NEC PASS SEEARTICLE215.3 CONDUIT MUST MEET NEC PASS /' ER SIZE:11'x FLai DAL 5 SEEART/CLE2f5.3 RECOMMENDATION FOR MINIMUM SIZE NEC CODE REQUIRES THAT THE OCPD BE RATED FOR NO LESS RECOMMENDATION FOR MINIMUM SIZE �� d O NEC CODE REQUIRES THAT THE OCPD BERATED FOR NO LESS (ARTICLE 390.17) THAN 1.25 TIMES THE CONTINUOUS CURRENT OF THE CIRCUIT. (ARTICLE 300.17) THAN 1.25 TIMES THE CONTINUOUS CURRENT OF THE CIRCUIT. 0.751N.>=0.751N.=TRUE 32A X 1.25=40A ROUNDED DOWN To 40A 0.751N.>=0.751N.=TRUE �i S URV n \` NT 32A X 1.25=40A ROUNDED DOWN TO 40A F.MINIMUM REQUIRED EGC SIZE 8 AWG DATA I na.3al2p1�1 t jl F.MINIMUM REQUIRED EGC SIZE 8AWG SEE TABLE250.122 DESIGN BY:O.S. L SEE TABLE 250.f22 THE SMALLEST EGG SIZE ALLOWED BY TABLE 250.122IS 8 AWG. CHECKED BY: M.M. THE SMALLEST EGC SIZE ALLOWED BY TABLE 250.122 IS 8 AWG. REVISIONS 6 R-009x00 A�' B C D LWE F EllC H (SHEET 19)