HomeMy WebLinkAboutROOFING PERMIT INFORMATION SHEET�,
ST. LUCIE WORKS
ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET
Florida Building Code 7th Edition (2620)
o a' Based on Section 1525 of the Florida Building Code Building
LU INSTRUCTION PAGE
oo
COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET
APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED -
BELOW:
Roof System
Required Sections of
the Permit Application -
Form
Attachments Required
See List Below
.I
.
low
Low Slope Application
A, B, C
f,29;47
I
Prescriptive BUR-RAS 150
A, B, C
2,4,5,6,7
Asphaltic Shingles
A, B, D
i
Concrete or Clay Tile
A, B, D, E
1-2Z&4A*7
Metal Roofs
A, B, D
-1,2,44AC7
Wood Shingles and
Shakes
A, B,.D
1.,,2;4 I7
Other
As Applicable
1,23 AV
ATTACHMENTS REQUIRED As Applicable):
1.
Fire'Directory Listing Page
2.
From Product Approval:
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
3.
1
Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS
128
4.
Other Component of Product Approval.
5.
i
Municipal Permit Application
6.
Owners Notification for Roofing Considerations (Reroofing Only)
7.
Any Required Roof Testing/Calculation Documentation
Form RooflnfoFeb21 Rev Feb 18, 2021
Sir. t
Mast
Cont
Job A
El Lc
El N
Low
Sketc
Inclu
UCIE WORKS =
Section A (General Information)
er Permit No. U V Process No.
ractors Name: M U \� ��� License #
,ddress_ Q $ �u Jr fort fL 3lY9,Y2
=
ROOF CATEGORY
w Slope E] Mechanically Fastened Tile E] Mortar/Adhesive
phaltic Shingles E] Metal Panel/Shingles Elwood Shingles/Shakes
El Prescriptive BUR-RAS 150
ROOF ROOF TYPE
lew roof El Repair 17 Maintenance 10,1 eroofing El
//�� ROOF SYSTEM INFORMATION j
Slope Roof Area (SF) GOO Steep Sloped Roof Area.(SF) `500
Section B-(Roof Plan)
h Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers
de dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and
Set Tiles
Recovering
Total (SF)
and overflow dr
location of parap
i_
{1
I -
`
I
'f
i
i
I
ains.
ets.
i ST. LuCIE WORKS.,
Section C (Low Slope Roof)
Fill in specific roof assembly components.and identify
manufacturer
(If a component is not used, identify as "NA")
System Manufacturer:
Product Approval No.:
Design Wind Pressures, From RAS 128 Or Calculations:
Zone 1': Zone 1: Zone 2: Zone 3:
Max. Design Pressure, from the specific product approval
system:
Deck:
Type:
Gauge Thickness:
Slope:
Anchor/Base Sheet & No. df Ply(s):
Anchor/Base Sheet Fastener/Bonding Material:
Insulation Base Layer:
Base Insultation Size and Thickness:
Base Insulation Fastener/Bonding Material:
Top Insulation Layer:
Top Insulation Size and Thickness:
Top Insulation Fastener/Bonding Material:
Base Sheet(s) & No. of Ply(s):
Base Sheet Fastener/Bonding Material:
Ply Sheet(s)' & No. of Ply(s):
Ply Sheet Fastener/Bonding Material:
Top Ply:
Top Ply Fastener/Bonding Material:
Surfacing:
Fastener Spacing for Anchor/Base Sheet Attachment:
Zone 1':—" ocl.@ Lap, # Rows `QQ
Zone 1:—." oc @Lap, # Rov.1 ® woo
Zone 2:—" oc @ Lap, # Rows '
Zone 3:—" oc @ Lap, # Rows
I
i
Number of Fasteners Per Insulation Board:
Zone 1': Zone 1: Zo , e 2: Zone I
Illustrate Components Noted al Details as Applicable:
Woodblockin'g, Gutter, Edgel Termination, Stripping,
Flashing, . Continuous Cleat, Cant Strip, Base Flashing,
Counterflashing, (Coping, Etc,
Indicate: Mean Roof Height, Parapet Height, Height of Base
Flashing, Component Material, Material' Thickness, Fastener
Type, FastenerSpbcing or Submit Manufacturers Details that
Comply with RAS 111 and Chapter 16.
,
1 FT.
7--
Parapet
Height
I
FT.
j Mean
Roof
Height
Section D (Steep Slope Roof System)
i
Roof System Manufacturer:
Notice of Acceptance Number:
Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations):
Zone 1: Zone 2e: Zone 2n:_Zone 2r: Zone 3e: Zone 3r.
i
Deck Tjrpe: 5�2 �C,
FEoof TyWUededaycneii Inguiatibm
�dATz
Firs Barrier: All A
Ridge Verda.' ? Fastener Type & Spacing: .
�z i.
Adhesive Type:
. Type-Caa Sheet � �--
i
MeanRddfHeight: 'ZO R Coxeclilg: 'L100
Type S.Srze Drip
Ii
I
I.
I
2a,
ST LUCIE WORK
Section E (Tile Calculations)
For Moment based tile systems, choose either Method 1 or 2. Compare the values for M, with the
are greater than or equal to.the Mrvalues, for each area of the roof,'then the the attachment me
Method 1'Moment Based Tile Calculations Per RAS 12T
(Zone 1: _ Product Approval Mu
_.._. _;Nd
(Zone 2e: - _ _j_-Ii cl Product Approval M
Zone 2n: Xil = Product Approval M
(Zone2r: Xk = -,Ii Product ApprovalMf
(Zone 3e: MM Product Approval M
X;
(Zone 3r. = .-=.�- '.M$ Product Approval Mi
Method 2 "Simplified Tile Calculations Per Table'iBelow"
Required Moment of Resistance (Mr) From Table Below Product Approval Mf
uesfrom Mr. If the Mr values
id is acceptable.
Mr required Moment Resistance*
Mean Roof Height Roof Slope
15'
20'
25'
i. 30'
40'
2'.12
34.4
36.5
38.2
j 39.7
42.2
3:12
32.2
34.4
36.0
37.4
39.8
4:12
30.4
32.2
33.8
j35.1
37.3
5:12
28.4
30.1
31.6
32.8
34.9
6:12
26.4
28.0
29.4
30.5
32.4
7:12
24.4
25.9
27.1
28.2
30.0
*Must be used in conjunction with a list of moment based tile systems
For Uplift based tile systems use Method 3. Compare the values for F' with the values for Fr If the F' values are greater than or
equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable.
Method 3."Uplift Based Tile Calculations Per RAS 12T
(Zone 1: x L =x W:= ) -W: cos r =Fri Product Approval F'
(Zone 2e: x L =x W:= ) -W: cos r =Fr2e ProductApproval F'I
(Zone 2n:-x L =x W:= ) -W cos r =Fr2n Prod uctApproval Fd
(Zone 2r x L =x W:=. ) -W: cos r =Fr2r Product Approval F'I
(Zone 3e: x L =x W:= ) -W: cos r =Fr3e Prod uctApproval F'1
(Zone 3r: x L =x W:= ) -W: cos r =Fr3r ProductApproval F'1
Where to Obtain Information
Description
Symbol
!. Where to find
Design Pressure
Zones 1, 2e, 2n, 2r, 3e, 3r
From applicable table i RAS 127 or by in
prepared by PE based on ASCE 7
engineering analysis
Mean Roof Height
H
Job Site
Roof Slope
6
Job Site
Aerodynamic Multiplier
a
Product Approval j
Restoring Moment due to Gravity
Mg
Product Approval
Attachment Resistance
Mf
Product Approval
Required Moment Resistance
Mg
Calculated
Minimum Attachment Resistance
F'
Product Approval
Required Uplift Resistance
Fr
Calculated
Average Tile Weight
W
Product Approval
Tile Dimensions
L = length W = width
Product Approval
1
All calculations must be submitted to the building official at the time of
permit application.
1