Loading...
HomeMy WebLinkAboutROOFING PERMIT INFORMATION SHEET�, ST. LUCIE WORKS ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2620) o a' Based on Section 1525 of the Florida Building Code Building LU INSTRUCTION PAGE oo COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED - BELOW: Roof System Required Sections of the Permit Application - Form Attachments Required See List Below .I . low Low Slope Application A, B, C f,29;47 I Prescriptive BUR-RAS 150 A, B, C 2,4,5,6,7 Asphaltic Shingles A, B, D i Concrete or Clay Tile A, B, D, E 1-2Z&4A*7 Metal Roofs A, B, D -1,2,44AC7 Wood Shingles and Shakes A, B,.D 1.,,2;4 I7 Other As Applicable 1,23 AV ATTACHMENTS REQUIRED As Applicable): 1. Fire'Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. 1 Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval. 5. i Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Form RooflnfoFeb21 Rev Feb 18, 2021 Sir. t Mast Cont Job A El Lc El N Low Sketc Inclu UCIE WORKS = Section A (General Information) er Permit No. U V Process No. ractors Name: M U \� ��� License # ,ddress_ Q $ �u Jr fort fL 3lY9,Y2 = ROOF CATEGORY w Slope E] Mechanically Fastened Tile E] Mortar/Adhesive phaltic Shingles E] Metal Panel/Shingles Elwood Shingles/Shakes El Prescriptive BUR-RAS 150 ROOF ROOF TYPE lew roof El Repair 17 Maintenance 10,1 eroofing El //�� ROOF SYSTEM INFORMATION j Slope Roof Area (SF) GOO Steep Sloped Roof Area.(SF) `500 Section B-(Roof Plan) h Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers de dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and Set Tiles Recovering Total (SF) and overflow dr location of parap i_ {1 I - ` I 'f i i I ains. ets. i ST. LuCIE WORKS., Section C (Low Slope Roof) Fill in specific roof assembly components.and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: Product Approval No.: Design Wind Pressures, From RAS 128 Or Calculations: Zone 1': Zone 1: Zone 2: Zone 3: Max. Design Pressure, from the specific product approval system: Deck: Type: Gauge Thickness: Slope: Anchor/Base Sheet & No. df Ply(s): Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer: Base Insultation Size and Thickness: Base Insulation Fastener/Bonding Material: Top Insulation Layer: Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): Base Sheet Fastener/Bonding Material: Ply Sheet(s)' & No. of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: Top Ply Fastener/Bonding Material: Surfacing: Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1':—" ocl.@ Lap, # Rows `QQ Zone 1:—." oc @Lap, # Rov.1 ® woo Zone 2:—" oc @ Lap, # Rows ' Zone 3:—" oc @ Lap, # Rows I i Number of Fasteners Per Insulation Board: Zone 1': Zone 1: Zo , e 2: Zone I Illustrate Components Noted al Details as Applicable: Woodblockin'g, Gutter, Edgel Termination, Stripping, Flashing, . Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, (Coping, Etc, Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, FastenerSpbcing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16. , 1 FT. 7-- Parapet Height I FT. j Mean Roof Height Section D (Steep Slope Roof System) i Roof System Manufacturer: Notice of Acceptance Number: Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): Zone 1: Zone 2e: Zone 2n:_Zone 2r: Zone 3e: Zone 3r. i Deck Tjrpe: 5�2 �C, FEoof TyWUededaycneii Inguiatibm �dATz Firs Barrier: All A Ridge Verda.' ? Fastener Type & Spacing: . �z i. Adhesive Type: . Type-Caa Sheet � �-- i MeanRddfHeight: 'ZO R Coxeclilg: 'L100 Type S.Srze Drip Ii I I. I 2a, ST LUCIE WORK Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values for M, with the are greater than or equal to.the Mrvalues, for each area of the roof,'then the the attachment me Method 1'Moment Based Tile Calculations Per RAS 12T (Zone 1: _ Product Approval Mu _.._. _;Nd (Zone 2e: - _ _j_-Ii cl Product Approval M Zone 2n: Xil = Product Approval M (Zone2r: Xk = -,Ii Product ApprovalMf (Zone 3e: MM Product Approval M X; (Zone 3r. = .-=.�- '.M$ Product Approval Mi Method 2 "Simplified Tile Calculations Per Table'iBelow" Required Moment of Resistance (Mr) From Table Below Product Approval Mf uesfrom Mr. If the Mr values id is acceptable. Mr required Moment Resistance* Mean Roof Height Roof Slope 15' 20' 25' i. 30' 40' 2'.12 34.4 36.5 38.2 j 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 j35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 27.1 28.2 30.0 *Must be used in conjunction with a list of moment based tile systems For Uplift based tile systems use Method 3. Compare the values for F' with the values for Fr If the F' values are greater than or equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable. Method 3."Uplift Based Tile Calculations Per RAS 12T (Zone 1: x L =x W:= ) -W: cos r =Fri Product Approval F' (Zone 2e: x L =x W:= ) -W: cos r =Fr2e ProductApproval F'I (Zone 2n:-x L =x W:= ) -W cos r =Fr2n Prod uctApproval Fd (Zone 2r x L =x W:=. ) -W: cos r =Fr2r Product Approval F'I (Zone 3e: x L =x W:= ) -W: cos r =Fr3e Prod uctApproval F'1 (Zone 3r: x L =x W:= ) -W: cos r =Fr3r ProductApproval F'1 Where to Obtain Information Description Symbol !. Where to find Design Pressure Zones 1, 2e, 2n, 2r, 3e, 3r From applicable table i RAS 127 or by in prepared by PE based on ASCE 7 engineering analysis Mean Roof Height H Job Site Roof Slope 6 Job Site Aerodynamic Multiplier a Product Approval j Restoring Moment due to Gravity Mg Product Approval Attachment Resistance Mf Product Approval Required Moment Resistance Mg Calculated Minimum Attachment Resistance F' Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval Tile Dimensions L = length W = width Product Approval 1 All calculations must be submitted to the building official at the time of permit application. 1