HomeMy WebLinkAboutBUILDING PLANSGENERAL NOTES: 1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION 2. THE DESIGN & CONSTRUCTION OF THIS STRUCTURE MUST FULLY COMPLY WITH THE 2020 FLORIDA BUILDING CODE (7TH EDITION), LATEST EDITIONS OF ACI 318, NCMA, NATIONAL FOREST PRODUCT ASSOC., NDS, TPI, AND ANY OTHER NATIONALLY RECOGNIZED ORGANIZATIONS THAT GOVERN THIS BODY OF WORK. 3. TRUSS MANUFACTURER SHALL SUBMIT SHOP DRAWINGS FOR BUILDERS APPROVAL. THESE DRAWINGS SHALL BE SEALED BY A FLORIDA REGISTERED ENGINEER AND REVIEWED BY THE ENGINEER OF RECORD. THE ENGINEER OF RECORD RESERVES THE RIGHT TO MAKE ANY NECESSARY CHANGES TO THE LAYOUT AND OR DESIGN OF SAID DRAWINGS, AND SHALL NOTIFY THE TRUSS MANUFACTURER/TRUSS ENGINEER OF SAID CHANGES WITHIN 1 WEEK OF RECEIVING THE SUBMITTED SHOP DRAWINGS. 4. ALL WORK SHALL COMPLY WITH ALL LOCAL AND REGIONAL ORDINANCES. a DESIGN PARAMETERS FOR WIND LOAD COMPLIANCE It 1. RISK CATEGORY: II 77 2. CODE REFERENCE: 2020 FLORIDA BUILDING CODE-R (7TH EDITION) & ASCE 7-16 N 2020 EXISTING FLORIDA BUILDING CODE (7TH EDITION) - LEVEL 3 ALTERATION N 3. BUILDING DESIGN: ENCLOSED 4. MEAN ROOF HEIGHT: 23.3' LLI 5. ROOF PITCH: 6/12 DEGREES 6. GCpi: t 0.18 7. WIDTH OF END ZONE: A = 5.6' 8. WIND SPEED: 160 MPH (Vult) 3-SECOND GUST 124 MPH (Vasd) 3-SECOND GUST *USED FOR ANALYSIS* 9. WIND EXPOSURE: C 10. ADJUSTMENT FACTOR: 1.35 11. SUPERIMPOSED LOADS: FLOOR (DEAD) 20 PSF FLOOR (LIVE) 40 PSF ROOF (TOP CHORD DEAD) 15 PSF ROOF (TOP CHORD LIVE) 20-PSF ROOF (BOT. CHORD DEAD) 5 PSF WALL 55 PSF (REINF. CMU) / 18 PSF (WOOD FRAMED) 12. SHEAR WALLS WERE CONSIDERED 13. A CONTINUOUS LOAD PATH WAS PROVIDED 14. COMPONENT & CLADDING DETAILED 0 15. MINIMUM SOIL BEARING PRESSURE IS 2,000 PSF PRESUMPTIVE N CONCRETE NOTES: co 1. CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE LATEST EDITIONS OF ACI 301 "SPECIFICATION FOR STRUCTURAL CONCRETE FOR H BUILDINGS" AND ACI 318 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE. Q 2. STRUCTURAL CONCRETE SHALL CONFORM TO THE REQUIREMENTS OF ACI 301 AND SHALL ATTAIN A MINIMUM COMPRESSIVE STRENGTH IN 28 DAYS OF 3,000 PSI. UNLESS NOTED OTHERWISE. 3. CONCRETE, WHEN PLACED, SHALL HAVE A SLUMP OF 4 INCHES PLUS OR. MINUS ONE INCH. 4. PROVIDE A MINIMUM OF 6 MIL VAPOR BARRIER AT ALL AIR CONDITIONED SPACES & GARAGES. HOLES IN VAPOR BARRIER ARE NOT PERMITTED. TAPE AROUND ALL SEAMS AND CUT-OUTS. 5. ALL REINFORCING SHALL CONFORM TO ASTM A615 FOR GRADE 60 STEEL/WELDED WIRE MESH TO CONFORM TO ASTM A-185 5.1. PROVIDE CHAIRS AND BOLSTERS 5.1.1. BOLSTERS TO HAVE PLASTIC COATED LEGS AND FEET (IF EXPOSED TO EXTERIOR ELEMENTS) 5.2. ENSURE MESH IS EMBEDDED 1" FROM THE TOP OF THE SLAB. LAP JOINTS AT 8" & TIE. 6. WELDED WIRE FABRIC SHALL BE IN ACCORDANCE WITH ASTM A-185 AND SHALL BE ADEQUATELY SUPPORTED @ T-0" O.C. EACH WAY 7. THE MINIMUM CONCRETE COVERAGE SHALL BE AS FOLLOWS: 7.1. CAST AGAINST EARTH: 3" 7.2. EXPOSED TO EXTERIOR ELEMENTS: 1" 7.3. FORMED SURFACES: 1" 8. CONSTRUCTION JOINTS DESIGN AND LOCATION SHALL CONFORM STRICTLY TO THE REQUIREMENTS OF THE PLANS AND SPECIFICATIONS. ANY CONSTRUCTION OR CONTROL DESIRED OR PREFERRED BY THE CONTRACTOR SHALL BE APPROVED BY THE ENGINEER PRIOR TO CONSTRUCTION OF THOSE AREAS INVOLVED. 9. CHECK ALL DRAWINGS AND APPLICABLE MANUFACTURER'S SHOP DRAWINGS FOR LOCATION OF ALL EMBEDOF"D ITEMS, SUCH AS PIPE SLEEVES, ANCHOR BOLTS, ETC PRIOR TO PLACING CONCRETE. 10. REINFORCEMENT FOR CONTINUOUS FOOTINGS SHALL BE CONTINUOUS AND SPLICED WITH A FULL 0 INCH LAP. PROVIDE CORNER BARS. 11. CONTRACTOR SHALL PROVIDE SAWCUTS IN SLAB @ A MAX. SPACING OF 20 FEET ON CENTER EACH WAY OR 400 S.F. AND AT ALL RE-ENTRANT CORNERS. SAW CUT SHALL BE 1/4 OF THE SLAB DEPTH AND SHALL- BE PERFORMED AS SOON AS THE CONCRETE HAS HARDENED SUFFICIENTLY ENOUGH TO CONTROL THE STRESSES, AN INHERENT PROPERTY OF CONCRETE WHICH SOMETIMES RESULTS IN CRACKS (WHICH IS NOT UNCOMMON) 12. CONCRETE FOR SLABS ON GRADE AND ELEVATED SLABS SHALL HAVE 3/4" LARGE AGGREGATE. "PEAROCK" IS NvOT PERMITTED FOR SLABS. 13. CONCRETE PORCH OUTRIGGERS, EXTERIOR FORMED AND POURED COLUMNS, AND REINFORCED EXTERIOR S!_ABS SHALL CONTAIN W.R.GRACE DCI-S CORROSION INHIBITOR AT THE RATE OF 2-1/2 GALLONS PER YARD. CONCRETE SHALL HAVE A MAX. W/C RATIO OF 0.04 AND A MIN. DESIGN STRENGTH OF 5000 PSI @ 28 DAYS. 13.1. ELEVATED SLABS SHALL BE TEMPORARILY SHORED UNTIL FULLY CURED. 14. ALL CONCRETE THAT IS ALTERED (WATER, ADDITIVES, ETC) SHALL BE TESTED TO ENSURE STRENGTH REQ! iIR:_MENTS ARE MET. 15. TERMINATE ALL VERTICAL REINFORCING AT THE TOP AND BOTTOM WITH 10" ACI HOOKS. 16. SOILS SHALL BE TREATED. FOUNDATION NOTES: 1. SOIL TO BE COMPACTED TO AT LEAST 95% OF MAX. DRY DENSITY AS DETERMINED BY ASTM-1557 (MODIFIED PROCTOR). 2. FOUNDATIONS ARE DESIGNED BASED ON PRESUMPTIVE SAFE MINIMUM SOIL BEARING PRESSURE OF 2,000 PSF. 3. FOOTINGS SHALL BE PLACED ON COMPACTED SOIL FREE OF ORGANIC DEBRIS. WINDOW AND DOOR NOTES: 1. WINDOWS, DOORS, SHUTTERS, AND ALL COMPONENTS SHALL BE DESIGNED ANP INSTALLED PER THE MINIMUM DESIGN PRESSURES AS PRESCRIBED IN THESE PLANS. 2. ALL EXTERIOR GLAZING SHALL BE IMPACT RESISTANT OR HAVE PROTECTION PER SECTION R301 OF THE 2020 FBC RESIDENTIAL CODE. PROTECTION SHALL BE DESIGNED FOR THE SAME WIND DESIGN PRESSURES AS THE WINDOWS OR DOORS THEY ARE COVERING. 3. ALL WINDOWS AND DOORS ARE TO BE INSTALLED ON 1X OR 2X PRESSURE TREATED BUCKS, AND AS PER MANUFACTURERS SPECIFICATIONS UNLESS OTHERWISE NOTED. CONCRETE MASONRY NOTES: 1. ALL MASONRY BLOCK SHALL CONFORM TO THE REQUIREMENTS OF ASTM C90 FOR LOAD BEARING CONCRETE MASONRY. 1.1. MIN. PRISM STRENGTH OF 1,900 PSI W/ 3/8" MORTAR JOINTS. 2. ALL MORTAR SHALL BE A MINIMUM TYPE M OR S MORTAR 3 3. UNLESS SPECIFICALLY SHOWN OTHERWISE PROVIDE "DUR-O-WALL" TRUSS TYPE REINFORCING IN EVERY OTHER COURSE (16" O.C.) -p 4. ALL LAP SPLICES MUST BE 48 BAR DIAMETERS. Q 5. WHERE INDEPENDENT CONCRETE COLUMNS ARE ABUTTED BY MASONRY WALLS, PROVIDE DOVETAIL ANCHORS FOR THE FULL HEIGHT OF 0 THE COLUMNS. U) 6. ALL CONCRETE MASONRY CONSTRUCTION SHALL CONFORM WITH ACI 530.1/ASCE 7-10/TMS 602, SPECIFICATION FOR CONCRETE MASONRY ' STRUCTURES AND ACI 530/ASCE 7-10/TMS 402, BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES. ALL CONCRETE MASONRY UNITS SHALL COMPLY WITH ASTM C-90 WITH TYPE M OR S MORTAR COMPLYING TO ASTM C-270. MASONRY UNITS SHALL HAVE A MINIMUM N COMPRESSIVE STRENGTH OF 2,000 PSI ON THE NET AREA. U, 7. ALL 8" EXTERIOR CMU WALL SHALL BE REINFORCED WITH #5 VERTICAL REINFORCING BARS WHERE SHOWN ON ARCHITECTURAL PLANS AT CENTER OF GROUTED CELL. PROVIDE 9 GA. TRUSS TYPE HORIZONTAL JOINT REINFORCING AT 16" O.C. IN ALL NEW WALLS. PROVIDE p) ADDITIONAL REINFORCING ON EACH SIDE OF OPENING GRATER THAN 24" WIDE & AT CORNERS & INTER- SECTIONS OF WALLS. CARE SHALL 1 BE TAKEN DURING THE CMU WALL ERECTION TO ENSURE THAT CELLS TO BE GROUTED LINE UP PROPERLY, PROVIDING A MINIMUM CLEAR AREA OF 10 SQUARE INCHES & MIN. CLEAR DIM. OF 3" PROVIDE SAW -CUT CLEAN -OUT HOLE IN BOTTOM COURSE & REMOVE MORTAR = DROPPINGS FROM CELLS AT END OF EACH DAY. PROVIDE FOOTING DOWELS TO MATCH WALL REINFORCING SIZE & SPACING. LAP SPLICE O REINFORCING 48 BAR DIA. (OR AS SHOWN ON PLANS) & TERMINATE REINFORCING WITH STANDARD ACI HOOKS TO PROVIDE CONTINUOUS CDREINFORCING FROM FOOTING TO UPPERMOST TIEBEAMS. TIE VERTICAL REINFORCING TO INSURE PLACEMENT IS IN CENTER OF WALL. 1 7.1. WHERE 2 VERTICAL BARS ARE SHOWN IN 1 CELL, INSTALL 1 BAR ON THE INTERIOR FACE OF THE WALL & 1 BAR ON THE EXTERIOR FACE Q OF THE WALL, 2" FROM THE EXPOSED FACE OF THE BLOCK. 8. PROVIDE BOND BEAM PER PLANS AROUND PERIMETER OF THE BUILDING @ THE TOP OF ALL WALLS AND AT JOIST BEARING. -� 8.1. BOND BEAM TO HAVE A MINIMUM OF (2) #5 BARS OR (1) #7 BAR TOP AND BOTTOM (UNLESS OTHERWISE NOTED). 8.2. H-BLOCK TIE BEAM STEEL TO STOP 8" FROM CORNERS WITH (1) #5 CORNER BAR (OR 1 #7) TOP & BOTTOM :32" MIN. LAP. 9. VERTICAL REINFORCEMENT STEEL TO HAVE A 1/2" MIN. CLEARANCE FROM MASONRY. m 10. GROUTED CELLS SHALL NOT EXCEED A 12' CONTINUOUS POUR. m 11. PROVIDE "CAST-CRETE" (OR APPROVED EQUAL) PRECAST CONCRETE LINTELS AT ALL MASONRY OPENINGS, UNLESS NOTED OTHERWISE. 12. ANY EPDXY SHOWN SHALL BE EITHER "HILTI HIT RE 500" WITH "HAS-E" THREADED RODS FOR MASONRY OR "SIMPSON XP22" WITH THREADED ROD. CD 12.1. ALL THREADED ROD HOLES TO BE 1/8" DIA. LARGER THAN REINFORCING STEEL OR THREADED ROD FOR EASE OF INSTALLATION. C TIMBER NOTES: 1. PRE-ENGINEERED WOOD TRUSSES SHALL BE DESIGNED BY A FLORIDA REGISTERED ENGINEER FOR ALL LOADS PRESCRIBED. ROOF r- TRUSS ENGINEERING SHOP DRAWINGS SHALL INCLUDE TRUSS LAYOUT, DESIGN LOADS, TRUSS REACTION, (DEAD LOAD & LIVE LOAD AND 0 DEAD LOAD & WIND LOAD), AND ALL OTHER INFORMATION REQUIRED FOR PROPER TRUSS INSTALLATION, ERECTION AND BRACING 0 CRITERIA. DESIGN OF ROOF TRUSSES SHALL INCLUDE THE UPLIFT EFFECTS OF 160 MPH DESIGN WIND LOAD BASED ON THE 2020 FLORIDA BUILDING CODE, 6TH EDITION. 01.1. ROOF TRUSSES SHALL NOT BE DELIVERED TO THE CONSTRUCTION SITE MORE THAN 3 DAYS PRIOR TO INSTALLATION, AND SHALL BE STORED IN ACCORDANCE WITH TPI-95. 1.2. TRUSS ENGINEER SHALL PROVIDE A WEB MEMBER AT ANY AND ALL PITCH CHANGES OF THE TOP AND BOTTOM CHORD, EXTENDING TO PANEL POINT ON OPPOSITE CHORD. MAX. LENGTH OF BOTTOM PANEL SHALL NOT EXCEED 9 FT. EXCEPT @ SHORT TRUSS HEELS J WHERE REQUIRED HURRICANE STRAP WILL BEND OVER TOP CHORD. PROVIDE VERTICAL WEB OVER ALL TRUSS BEARING LOCATIONS. 1.3. ALL MEMBERS SHALL BE A MINIMUM OF 2 X 4 #2 SYP. 1.4. ALL VALLEY SETS SHALL BE FRAMED WITH VALLEY SET TRUSSES AND ATTACHED TO TRUSSES BELOW PER SPECIFIED STRAPPING @ 6' O.C. MAX. ROOF PLYWOOD SHALL EXTEND ON TRUSSES BENEATH ALL OVER FRAMING. OMIT PLYWOOD AND VALLEY SET BOTTOM CHORD BETWEEN TWO TRUSSES FOR ACCESS. 1.5. IN ADDITION TO THE DESIGN LOADS LISTED, THE TRUSSES SHALL BE DESIGNED FOR ADDITIONAL LOADS WHERE APPLICABLE (I.E. A/C EQUIPMENT, ETC.) 1.6. DESIGN BOTTOM CHORDS FOR ATTIC TRUSSES FOR LIVE LOAD PER 2020 FBG R301.5. TRUSSES SUPPORTING MECHANICAL EQUIP. SHALL BE DESIGNED FOR (2) 100 LB POINT LOADS T APART LOCATED ANYWHIERE ON THE TOP CHORD. 1.7. TRUSSES MUST BE CONFIGURED TO PROPERLY ATTACH ALL HANGERS SHOVVN ON PLANS OR IN SHOP DRAWINGS. TRUSS ENGINEER MUST SPECIFY ALL TRUSS TO TRUSS CONNECTIONS. 1.8. ALL ROOF TRUSSES AND RAFTERS SHALL BE ANCHORED WITH A TRUSS CONNECTOR STRAP AS PER PLAN OR SCHEDULE & A VAPOR BARRIER MUST BE PROVIDED BETWEEN TRUSSES AND CONCRETE. 2. ROOF SHEATHING SHALL BE A MIN. OF 5/8" CDX SPAN RATED STRUCTURAL PLYWOOD, INSTALLED WITH FACE GRAIN PERPENDICULAR TO ROOF FRAMING WITH 8d RING SHANK NAILS 6" O.C. AT PANEL EDGES AND 6" O.C. IN THE FIELD (U.N.O.). PROVIDE 2" X 4" BLOCKING AT HIPS AND VALLEYS. SPACE NAILS AT 4" O.C. AT BLOCKING. 3. EXTERIOR FRAME WALL SHEATHING TO BE A MIN. OF 1/2" APA SHEATHING, SPECIES GROUP 1, SPAN RATING OF 24/0 OR BETTER. UNLESS OTHERWISE NOTED, INSTALL WITH FACE GRAIN HORIZONTAL. PLYWOOD SHALL BE 4 PLY MINIMUM. NAIL TO STUDS USING 8d NAILS @ 4" O.C. AT PANEL EDGES AND 8" O.C. IN THE FIELD (U.N.0). DECREASE SPACING PER PLAN. AT SHEAR WALLS, NAIL TO EACH STUD AT THE END OF THE WALLS FOLLOWING THE EDGE SPACING. BACK OUT AND REMOVE ALL NAILS THAT DO NOT FULLY PENETRATE/MISS FRAMING MEMBERS.. 4. FLOOR SHEATHING TO BE 3/4" T & G CDX SPAN RATED STRUCTURAL PLYWOOD, INSTALLED WITH FACE GRAIN PERPENDICULAR TO FLOOR FRAMING GLUED & NAILED WITH 10d NAILS 6" O.C. AT PANEL EDGES AND 12" O.C. IN THE FIELD. 5. THE MINIMUM LUMBER GRADES SHALL BE AS SUCH: INT. & EXT. BEARING WALLS, TOP PLATES, WINDOW BUCKS, & HEADERS: SOUTHERN YELLOW PINE #2 OR BETTER BOTTOM PLATES AGAINST CONCRETE: PRESSURE TREATED SOUTHERN YELLOW PINE #2 OR BETTER 6. ALL TIMBER IN CONTACT WITH MASONRY OR CONCRETE SHALL BE PRESSURE TREATED OR HAVE AN APPROVED SEPARATING MATERIAL. 7. ALL NAILS AND METAL HARDWARE EXPOSED TO THE ELEMENTS SHALL BE GALVANIZED. ALL NAILS SHALL BE COMMON WIRE NAILS. SPACE NAILS AT STRAPS AS TO NOT SPLIT THE WOOD. WIND LOAD DESIGN CRITERIA: 1. DESIGN WIND LOAD ON INDIVIDUAL ROOF TRUSSES BASE UPON TRIBUTARY AREA SHALL BE AS FOLLOWS. 2. SEE ROOF PLAN FOR ZONE LOCATIONS. 3. OVERHANGS SHALL INCLUDE PORCHES, BALCONY ROOFS, ETC. 4. MAXIMUM DEADLOAD RESISTING UPLIFT SHOWN BELOW SHALL BE 8 PSF. FOR 6:12 AND LESS ROOF PITCH ZONE AREA ---PRESS[ IRE OVERHANG 1 10 53 _PRESSURE 28 N.A. 1 20 47 24 N.A. 1 50 39 19 N.A. 1 100 34 15 N.A. 2E 10 67 28 91 2E 20 51 24 76 2E 50 31 19 56 2E 100 31 15 56 2R 10 83 28 N.A. 2R 20 69 24 N.A. 2R 50 51 19 N.A. 2R 100 37 15 N.A. 3 10 94 28 119 3 20 69 24 94 3 50 37 19 62 3 100 37 15 62 EXTERIOR COMPONENTS ATTACHED TO THE WALL (SIDING, ETC): 1. EXTERIOR WALL COMPONENTS SHALL BE ATTACHED PER MANUFACTURERS REQUIREMENTS TO MEET THE WIND PRESSURES SHOWN. 2. END ZONE IS AT EXTERIOR CORNER, UNDER ROOF ZONE 3. INTERIOR ZONE IS REMAINDER. WALL ZONENEGATIVE POSITIVE END -PRESSURE 39 PSF ____PJRE5.SURE 32 PSF INTERIOR 35 PSF 32 PSF I ROOFING NOTES: 1. ROOFING MATERIALS SHALL BE ATTACHED PER MANUFACTURES SPECIFICATIONS TO MEET THE DESIGN CRITERIA IN THESE PLANS. 2. ASPHALT SHINGLES SHALL CONFORM TO ASTM D-3161 CLASS "F", ASTM D-7158 CLASS "H" OR TAS 107. OVER ENCLOSED AREAS ROOF ZONE ROOF SLOPE 6:12 OR LESS ROOF SLOPE: 7:12 OR MORE 2E 93 PSF N.A. 2R 110 PSF N.A. 3 114 PSF N.A. M SOFFITS: ZONE DESIGN PRESSURE 2 +32 / -35 PSF 3 +32 / -39 PSF ROOF ZONES SCALE: N.T.S. G G - ° e •� a �•^ •. .• .° � •°- a :p.ed.. %.e.• °e TRUSS BEARING -� DOUBLE BOND BEAM OVER PORCH OPENING 10" ACI HOOKS @ EACH BAR 16" X 8" OR 8" X 8" CMU BLOCK �COLUMN AT PORCH #5 BARS IN FILLED COLUMN (SEE PLAN FOR SPACING) --`- (1) #5 VERT. DOWN ROD �- (REF. PLAN) 10" ACI HOOKS @ EACH BAR SECURE UNDERNEATH BOTTOM CO,NT. STEEL 6" CONCRETE SLAB W/6X6 - W1A/W1.4 WWM OR FIBERMESH ON 6 MIL. VAPOR BARRIER ON WELL COMPACTED, TREATED FILL \R FOUNDATION PER FOUNDATION PLAN J t 3 PORCH BEAM TIE-IN DETAIL S_1 SCALE: 3/4" V-0" J w w z 2 w U m a d O i w U J a En J 441 TIE -BEAM OR DOUBLE BOND BEAM 10" ACI HOOKS @ EACH BAR #5 VERTICAL BAR IN FULLY GROUTED CELL (EA. SIDE OF OPENING) 2X P.T. BUCK CONTINUOUS BEAD OF POLYURETHANE SEALANT (INSTALLED BY WINDOW INSTALLER) SOLID INFILL OF STUCCO POLYURETHANE SEALANT (3Y CONTRACTOR) CONTINUOUS BEAD 0.` POLYURETHANE SEALANT (INSTALLED BY WINDOW INSTALLER) SOLID INFILL OF STUCCO 2X P.T. BUCK (2) 3/8" THICK BEADS OF POLYURETHANE SEALANT BEHIND BUCKS (BY BUCK INSTALLER) CONTINUOUS BEAD OF WATER RESISTANT SEALANT AT MASONRY/BUCK JOINT AT INTERIOR/EXTERIOR AND CORNER JOINTS (BY BUCK INSTALLER) CMU WATER RESISTANT COATING ON MASONRY OPENING JAMBS (BY CONTRACTOR) CONTINUOUS BEAD OF SEALANT AIR/WATER DAM @ SHIM GAP (BY CONTRACTOR) CONTINUOUS BEAD OF WATER RESISTANT SEALANT AT MASONRY/BUCK JOINT AT INTERIOR/EXTERIOR AND CORNER JOINTS (BY BUCK INSTALLER) (2) 3/8" THICK BEADS OF POLYURETHANE SEALANT BEHIND BUCKS (BY BUCK INSTALLER) NOTES: • WATER RESISITANT SEALANT AT MASONRY & WOOD BUCKS TO BE "TYVEK FLUID APPLIED FLASHING & JOINT COMPOUND" OR EQUAL • POLYURETHANE SEALANT UNDER BUCKS & AT WINDOW FRAME TO BE "DYNOMIC 100" BY TREMCO OR EQUAL • INTERIOR AIR/WATER SEALANT AT WINDOW FRAME IS TO BE "TREMFLEX 834" SILICONIZED ACRYLIC LATEX BY TREMCO OR EQUAL WINDOW WATERPROOFING DETAIL SCALE: 1" = V-0" 2X P.T. BUCK CONTINUOUS BEAD OF POLYURETHANE SEALANT (INSTALLED BY WINDOW INSTALLER) SOLID INFILL OF STUCCO POLYURETHANE SEALANT (BY CONTRACTOR) POLYURETHANE SEALANT (BY CONTRACTOR) EXTERIOR SILL NOSING FINISH MATERIAL, PITCH SILL A' SAY FROM DOOR CMU WATER RESISTANT COATING ON MASONRY OPENING JAMBS (BY CONTRACTOR) (2) 3/8" THICK BEADS OF POLYURETHANE SEALANT BEHIND BUCKS (BY BUCK INSTALLER)' CONTINUOUS BEAD OF WATER RESISTANT SEALANT AT MASONRY/BUCK JOINT AT INTERIOR/EXTERIOR AND CORNER JOINTS (BY BUCK INSTALLER) CMU WATER RESISTANT COATING ON MASONRY OPENING JAMBS (BY CONTRACTOR) CONTINUOUS BEAD OF SEALANT AIRIWATER DAM @ SHIM GAP (BY CONTRACTOR) FINISH FLOOR SLAB RECESS CMU WATER RESISTANT COATING ON MASONRY OPENING JAMBS (BY CONTRACTOR) NOTES: • WATER F-, ASITANT SEALANT AT MASONRY & WOOD BUCKS TO BE "TYVEK FLUID APPLIED FLASHING & JOINT COMPOUND" OR EQUAL • POLYURE : 'ANE SEALANT UNDER BUCKS & AT WINDOW FRAME TO BE "DYNOMIC 100" BY TREMCO OR EQUAL • INTERIOR AiR/WATER SEALANT AT WINDOW FRAME IS TO BE "TREMFLEX 834" SILICONIZED ACRYLIC LATEX BY TREMCO OR EQUAL • CONSULT WITH WINDOW MANUFACTURER TO DETERMINE ACTUAL SILL RECESS DIMENSIONS AND RESULTING BEAM HEIGHTS • ALL EXTERIOR DOORS MUST BE SET IN A RECESS. • VERIFY FINISH FLOOR MATERIAL AND RECESS DEPTH AND BEAM HEIGHT ELEVATIONS PRIOR TO POURING SLAB DUUR WATERPROOFING DETAIL SCALE: 1" = V-0" SILL REINFORCING SCHEDULE OPENING WIDTH SILL DEPTH REINFORCING STEEL_ WIDTH TO LESS THAN 7' 8" (1) #5 WIDTHS 7' TO LESS THAN 10' 8" (2) #3 SIDE BY SIDE WIDTHS 10' TO LESS THAN 15' 12" (4) #3 SIDE BY SIDE CMU W/ 9GA. LADDER BLOCKING @ EVERY OTHER COURSE 10" ACI HOOKS @ EACH BAR SECURE UNDERNEATH BOTTOM CONT. STEEL SLAB/FOUNDATION -SEE DETAILS TYPICAL CMU (BLO(K) OPENING REINFORCEMENT SCALE: 3/4" = V-0" TIE-BEAM.OR DOUBLE BOND "BEAM 4" 12" O.C. MAX. �MAX; 1 "z i 1' � • ROWS OF (2) 1/4" TAPCONS INTO GROUTED MASONRY W/ 2" EMBED (TYP.) - MIN. (3) ALL SIDES P.T. BUCK AS REQ. BY MANUFACTURER CMU 2 MA:ONRY DOOR BUCK ATTACHMENT S-1 SCALE: 3/4' = V-0" *NOTE: DOORS & WINDOWS SHALL BE INSTALLED PER MANUFACTURERS SPECIFICATIONS TO WITHSTAND THE MINIMUM DESIGN PRESSURES REQUIF�ED (AS NOTED IN THESE PLANS). U co N 0') (D M co U) :a co r� U N m N Ln O 2 cam- > 0ico 0 0 M 0 Q co U 0 cn N 0 ti U) co C4 cv N ti w di F= >: :r zm OW d v ��c o a Is o 0 v o w� a m L G m N W N I__ co 0 W ~ U) ry U1 Wd as W W U) W U W � U) N Lo J m > 0 L~ �IY- 0 O 06 w W \ U W OJ in �/) 0 U cn V I- v 1 O 0- Z (� Ld 0 W � 0 -0 of 0 06 .(n Y U) W (1) O il�F- z W J J .� U) W W m z � I- PROJ. NO. 21-690 DATE 03/03/2021 SHEET NO. S.1 SHEET OF 4 rn N N N W 5 T- N O N W LL c V_ N O N CD W U- REAR ELEVATION SCALE: 1/8" = 1'-0" LEFT ELEVATION SCALE: 1/8" = 1'-0" FRONT ELEVATION SCALE: 1/8" = 1'-0" RIGHT ELEVATION SCALE: 1/8" = 1'-0" METAL ROOF (SEE PRODUCT APPROVAL) OVER 15# UNDERLAYMENT OVER 5/8" CDX SHEATHING, 8d RINK SHANK NAILS @ 4" O.C. 12 12 AT SEAMS & 8" O.C. IN FIELD 5 5 PRE-ENGINEERED WOOD TRUSSES @ 24" O.C. F HURRICANE STRAP @ EA. TRUSS - PER 1 J SCHEDULE & LAYOUT j ICYNENE R-30 ICYNENE R-30 I I INSULATION PER INSULATION PER REPORT #ESR 1826 REPORT #ESR-1826 I I ALUM. DRIP EDGE OVER I 2 X 8 CEDAR FASCIA x 2'-0" O.H. TYP. ATTACHED TO TRUSSES W/ (3) 16d NAILS EA. TRUSS ^J NON -VENTED (SOFFIT) STUCCO OVER 3/8" HIGH -RIB LATH ATTACHED W/ 11 GA. X 1" EMBDED. NAILS W/ 7/16" HEAD (MIN.) @ 4" O.C. THROUGHOUT i STD. OR RECESSED PRE -CAST LINTELS ABOVE WINDOWS, DOORS &LARGER SPANNING (1):5 VERT. BAR IN GROUT FILLED OPENINGS W/ (1) #7 BAR TOP CELL LOCATED PER PLAN — COURSE & #5 BAR IN PRE -CAST LINTEL POURED WITH BEAM (CAST-CRETE OR EQ.) INSTALL ALL WINDOWS & DOORS PER FMA/AAMA 200-12 SPECIFICATIONS FOR WATER TIGHT INSTALLATION 8" X 16" CMU BLOCK W/ 9 GA. LADDER BLOCKING @ EVERY OTHER COURSE (2) COURSE "H" BLOCK AT MID -HEIGHT, (2) #5 CONT. OR (1) #7 EA. COURSE, CONT. POUR w D i x w � x r ❑ w ¢ m w o io O O ❑ w V J U , � E FL v E E OVERHEAD IMPACT DOOR I E I #5 ROD W/ 10" ACI HOOK INTO FOUNDATION, TIED TO BOTTOM I STEEL. SEE STRUCTURAL ENGINEERING LAYOUT FOR LOCATION AND SPACING (WHERE i SPLICE OCCURS 30" LAP. MIN) i i 6" CONCRETE SLAB W/6X6 - W1.4/WlA WWM OR FIBERMESH ON 6 MIL. VAPOR BARRIER ON WELL ' COMPACTED, TREATED FILL 6" CONCRETE SLAB W/6X6 - W1.4/W1.4.W'WM OR FIBERMESH ON 6 MIL. VAPOR BARRIER ON WELL COMPACTED, TREATED FILL 0 0o M■ METAL ROOF (SEE PRODUCT APPROVAL) OVER 15# UNDERLAYMENT OVER 5/8" CDX SHEATHING, 8d RINK SHANK NAILS @ 4" O.C. 12 AT SEAMS & 8" O.C. IN FIELD .��� 5 PRE-ENGINEERED WOOD TRUSSES @ 24" O.C. HURRICANE STRAP @ EA. TRUSS -PER SCHEDULE & LAYOUT ICYNENE R-30 INSULATION PER REPORT #ESR-1826 �- ALUM. DRIP EDGE OVER 2 X 8 CEDAR FASCIA DOUBLE BOND BEAM W/ (2) 2' 0" O.H. TYP. ATTACHED TO TRUSSES COURSES H-BLOCK WITH (1) #5 W/ (3) 16d NAILS EA. TRUSS BARS CONT. EACH COURSE NON VENTED (SOFFIT) STUCCO OVER 3/8" HIGH -RIB LATH ATTACHED W/ 11 GA. X 1" EMBDED. NAILS W/ 7/16" HEAD (MIN.) @ 4" O.C. THROUGHOUT DOUBLE BOND BEAM W/ (2) COURSES H-BLOCK WITH (1) #5 BARS CONT. EACH COURSE (1) #5 VERT. BAR IN GROU f FILLED CELL LOCATED PF-t PLAN z 8" X 16" CMU BLOCK W/ 9 GA. LADDER BLOCKING @ EVERY w U OTHER COURSE - J a U) g ALL GYPSUM BOARD TO CONFORM TO ASTM C5, C22, C28, C35, C59, C61, C587, C631, C847, C933, C1032 AND C1047 AND SHALL BE INSTALLED IN COMPLIANCE WITH ASTM C843/44 STD. OR RECESSED PRE -CAST LINTELS ABOVE WINDOWS, DOORS & LARGER SPANNING OPENINGS W/ (1) #7 BAR TOP COURSE & #5 BAR IN PRE -CAST LINTEL POURED WITH BEAM (CAST-CRETE OR EQ.) 2 TYPICAL WALL SECTION S-3 SCALE: 3/4" = V-0" STUCCO FINISH EXETRIOR STUCCO INSTALLED IN COMPLIANCE WITH ASTM C 926 & C 1063. 6" TERMITE INSPECTION STRIP REQUIRED I NON J INSTALL ALL WINDOWS & DOORS PER FMA/AAMA 200-12 SPECIFICATIONS FOR WATER TIGHT INSTALLATION 6" CONCRETE SLAB W/6X6 - W1.4/W1.4 WWM OR FIBERMESH ON 6 MIL. VAPOR BARRIER ON WELL COMPACTED, TREATED FILL -X \+ METAL ROOF (SEE PRODUCT APPROVAL) OVER 15# UNDERLAYMENT OVER 5/8" CDX SHEATHING, 8d RINK SHANK NAILS @ 4" O.0 AT SEAMS & 8" O.C. IN FIELD PRE-ENGINEERED WOOD TRUSSES @ 24" O.C. HURRICANE STRAP @ EA. TRUSS - PER SCHEDULE & LAYOUT �-- ALUM. DRIP EDGE OVER 2'-0" O.H. TYP. 2 X 8 CEDAR FASCIA ATTACHED TO TRUSSES W/ (3) 16d NAILS EA. TRUSS NON -VENTED (SOFFIT) STUCCO OVER 3/8" HIGH -RIB LATH ATTACHED W/ 11 GA. X 1" EMBDED. NAILS W/ 7/16" HEAD (MIN.) @ 4" O.C. THROUGHOUT ,,— STUCCO FINISH EXETRIOR STUCCO INSTALLED IN COMPLIANCE WITH ASTM C 926 & C 1063. IMPACT DOOR ' v ( (1) #5 HORIZ. BAR CONT. FOOTING REBAR (3) #5 BARS CONT. I WALL SECTION @ MAN DOOR Cv_3 SCALE: 3/4" = l'-0" UCD o N O M O co O ° U LL RS d = U N m N O O L' O oj00 0 0 M U N Q co U 0 U) w CV O co t ti N w N N N ti ti a W W f- Z om w d 'S e%....°I sw //" !' N O �. L••jVVJ11 Z '. 7 Ir-c v) Z o 0 . �• � ° b E�v�ww �a `.0 ��ab°vb �� V A z m N W O N (o O w ~ co 0� U) d ui as W W LLJ ¢ W W N 0) m M Lli 0 IL W ¢ co O ZO LL LLI Q Q.J U W J O L LI m V) f- Z m O L)o n E- U Lei w > cn � J � Q Y O �N/ LL fy- () J D �— _W .� U)w m .0 O U F— J T 1 tid) r=U) ❑ H PROJ. NO. 21-690 DATE 03/03/2021 SHEET NO. S-3 SHEET 3 OF 4 2 n rn N N N N W F- W Is LL.