HomeMy WebLinkAboutENERGY LOT 25FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: KHOV-EDEN
Builder Name: KHOVNANAIN HOMES
Street: 5126 ARMINA PLACE
Permit Office:
City, State, Zip: FT PIERCE, FL,
Permit Number:
Owner: EDEN MODEL LOT 25 @ WATERSTONE
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type$1796.7 sqft)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1516.70 ft2
b. Frame - Wood, Adjacent
R=11.0 280.00 ft2
3. Number of units, if multiple family 1
c. NIA
R_ ft2
4. Number of Bedrooms 4
d. NIA
R= ft2
5. Is this a worst case? No
11. Ceiling Types (1618.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1618.00 ft2
6. Conditioned floor area above grade (ft2) 1616
b. NIA
R= ft2
Conditioned floor area below grade (ft2) 0
c. NIA
R= ft2
7. Windows(154.9 sqft.) Description Area
12. Ducts
R ft2
a. Sup: Attic, Ret: HALL BATH, AH: HALL BATH 6 300
a. U-Factor: Dbl, U=0.28 113.92 ft2
SHGC: SHGC=0.30
b. U-Factor: Dbl, U=0.55 41.00 ft2
13. Cooling systems
kBtulhr Efficiency
SHGC SHGC=0.34
a. Central Unit
29.4 SEER:16.00
c. U-Factor: NIA ft2
SHGC:
Area Weighted Average Overhang Depth: 4.909 ft.
14. Heating systems
kBtulhr Efficiency
Area Weighted Average SHGC: 0.311
a. Electric Strip Heat
23.0 COPA.00
8. Skylights Area
c. U-Factor:(AVG) NIA ft2
15. Hot water systems
SHGC(AVG): NIA
a. Electric
Cap: 40 gallons
9. Floor Types (1616.0 sqft.) Insulation Area
EF:0.950
a. Siab-On-Grade Edge Insulation R=0.0 1616.00 ft2
b. Conservation features
b. NIA R= ft2
None
c. NIA R= ft2
16. Credits
Pstat
Glass/Floor Area: 0.096 Total Proposed Modified Loads: 54.01
PASS
Total Baseline Loads: 55.24
1 hereby certify that the plans and sp cifications covered by
Review of the plans and
-CJ' LE S7
this calculation are in compliance wi the Florida Energy
specifications covered by this,
Code.
calculation indicates compliance
ii
with the Florida Energy Code.
Melt hi' -; :€ � :�,•*'`�„ O
PREPARED BY: , "
Before construction is completed
DATE: `
this building will be inspected for,
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes..
with the Florida Energy Cade.
'0 �
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insu[ation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
6116/2021 8:18 AM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: KHOV-EDEN
Bedrooms: 4
Address Type:
Street Address
Building Type: User
Conditioned Area: 1616
Lot #
Owner Name: EDEN MODEL LOT 25 @ W Total Stories: 1
BlocWSubdivision:
# of Units: 1
Worst Case: No
PlatBook:
Builder Name: KHOVNANAIN HOMES
Rotate Angle: 0
Street:
5126 ARMINA PLACE
Permit Office:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State, Zip:
FT PIERCE,
Family Type: Detached
FL ,
New/Existing: New (From Plans)
Comment,
CLIMATE
/
Design Temp
Int Design Temp Heating
Design Daily Temp
1/ Design Location
TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL; Fort Pierce FL_VERO_BEACH^MUNI 39 90
70
75 299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1616 14220.8
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1 BED 3
161 1416.8 No 1
4
1 No
Yes
Yes
2 HALL BATH
77 678 No 0
1 No
Yes
Yes
3 FOYER
172 1514 No 0
1 No
Yes
Yes
4 BED 4
149 1307 No 1
1 No
Yes
Yes
5 LAUNDRY
52 458 No 0
1 No
Yes
Yes
6 BED 2
149 1307 No 1
1 No
Yes
Yes
7 GIRT DIN KITCHEN
550 4840 No 0
1 No
Yes
Yes
8 MASTER SUITE
176 1544 No 2
1 No
Yes
Yes
9 MAST WIC
58 506 No 0
1 No
Yes
Yes
10 M BATH
72 634 No 0
1 No
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
BED 3 38 ft 0
163 ft2
----
0 1
0
2 Siab-On-Grade Edge Insulatio
HALL BATH 11 ft 0
77 ft2
_---
1 0
0
3 Slab -On -Grade Edge Insulatio
FOYER 25 ft 0
172 ft2
__-_
1 0
0
4 Slab -On -Grade Edge Insulatio
BED 4 14 ft 0
148.5 ft2
_---
0 1
0
5 Slab -On -Grade Edge Insulatio
LAUNDRY 1 ft 0
52 ft2
----
1 0
0
6 Slab -On -Grade Edge Insulatio
BED 2 13.5 ft 0
148.5 ft2
__--
0 1
0
7 Slab -On -Grade Edge Insulatio
GRT DIN KITCHE 49 ft 0
550 ft2
----
0.5 0.5
0
6/16/2021 8:18 AM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
#
Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
8 Slab -On -Grade Edge Insulatio MASTER SUITE 26.5
ft 0
175.5 ft2
----
0
1
0
98Iab-On-Grade Edge Insulatio MAST WIC 11.5
ft 0
57.5 ft'
----
0
1
0
10SIab-On-Grade Edge Insulatio M BATH 1 ft
0
72 ft2
__-_
1
0
0
ROOF
/
Roof
Gable
Roof
Rad
Solar
SA Em€tt
Emitt Deck
Pitch
1/
#
Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1
Hip Composition shingles 1750 ft2
0 ft2 Medium
N
0.9
No 0.9
No 0
22.6
ATTIC
V
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Vented
150
1616 ft2
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented) BED 3
30
Blown
163 ft2
0.1
Wood
2
Under Attic (Vented) HALL BATH
30
Blown
77 ft2
0.1
Wood
3
Under Attic (Vented) FOYER
30
Blown
172 ft2
0.1
Wood
4
Under Attic (Vented) BED 4
30
Blown
149 ft2
0.1
Wood
5
Under Attic (Vented) LAUNDRY
30
Blown
52 ft2
0.1
Wood
6
Under Attic (Vented) BED 2
30
Blown
149 ft2
0.1
Wood
7
Under Attic (Vented) GIRT DIN KITCHE 30
Blown
550 ft2
0.1
Wood
8
Under Attic (Vented) MASTER SUITE
30
Blown
176 ft2
0.1
Wood
9
Under Attic (Vented) MAST WIC
30
Blown
58 ft2
0.1
Wood
10
Under Attic (Vented) M BATH
30
Blown
72 ft2
0.1
Wood
WALLS
Adjacent S ace Cavity Width
P
Height
reaSheathing
Framing Solar
Below
o
1
NE
Exterior Concrete Block - Int InsuI BED 3
4.1 13
1 9
4
122.1 ft2
0
0
0.5
0
2
SE
Exterior Concrete Block - Int InsuI BED 3
4.1 10
8 9
4
99.6 fie
0
0
0.5
0
3
SW
Exterior Concrete Block - Int Insul BED 3
4.1 12
2 10
0
121.7 ft2
0
0
0.5
0
4
SW
Exterior Concrete Block - Int InsLFHALL BATH
4.1 9
11 10
0
99.2 ft2
0
0
0.5
0
5
SE
Exterior Concrete Block- Int InsuI FOYER
4.1 4
10 9
4
45.1 ft2
0
0
0.5
0
6
SW
Exterior Concrete Block- Int Insul BED 4
4.1 12
7 10
0
125.8 ft2
0
0
0.5
0
7
NE
Exterior Concrete Block- Int Insul BED 2
4.1 13
1 9
4
122.1 ft2
0
0
0.5
0
8
SW
Exterior Concrete Block - Int InsfORT DIN KIT
4.1 22
6 10
0
225.0 ft2
0
0
0.5
0
9
NW
Exterior Concrete Block - Int InsORT DIN KIT
4.1 23
3 9
4
217.0 ft2
0
0
0.5
0
10
NE
Exterior Concrete Block - Int InsMASTER SUI
4.1 12
7 9
4
117.4 ft2
0
0
0.5
0
11
NW
Exterior Concrete Block - Int InsMASTER SUI
4.1 12
7 9
4
117.4 ft2
0
0
0.5
0
12
NE
Exterior Concrete Block - Int InsuMAST WIC
4.1 11
2 9
4
104.2 ft2
0
0
0.5
0
6/16/2021 8:18 AM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 5
FORM R405-2020 INPUT RIJMMARY r..HFrKI IAT RFPC]RT
WALLS
V it Ornt
To �Alall
TypeAdjacent Space Cavity Width Height
Sheathing Framing Solar
Below
0
13 NW
Garage Frame - Wood GRT DIN KIT 11 30 0 9 4 280.0 ft2
0 0 0.5
0
DOORS
#
Ornt
Door Type Space
Storms U-Value Width Height
Ft In Ft In
Area
1
2
NW
NW
Insulated GIRT DIN KIT None .46 3 8 24 ft2
Wood GIRT DIN KIT None .46 2.8 8 22.4 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
1/ #
Wall
Ornt ID Frame
Panes NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation Int Shade
Screening
1
2
3
4
5
6
7
SE 2 Metal
SW 6 Metal
NE 7 Metal
SW 8 Metal
NW 9 Metal
NW 9 Metal
NW 11 Metal
Double (Tinted) Yes
Double (Tinted) Yes
Double (Tinted) Yes
Double (Tinted) Yes
Double (Tinted) Yes
Double (Tinted) Yes
Double (Tinted) Yes
0.28 0.3 N 15.0 ft2 1 ftO in
0.28 0.3 N 15.0 ft2 1 ft O in
0.28 0.3 N 15.0 ft2 1 ft O in
0.55 0.34 N 41.0 ft2 11 ft 0 in
0.28 0.3 N 23.0 ft2 1 ft 0 in
0.28 0.3 N 23.0 ft2 9 ft 6 in
0.28 0.3 N 22.9 ft2 1 ft 0 in
1 ft 0 in None
1 ft 0 in None
1 ft 0 in None
1 ft 0 in None
1 ft 0 in None
1 ft 0 in None
1 ft 0 in None
None
None
None
None
None
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height
Exposed Wall Insulation
1
380 ft2
380 ft2
64 ft 8 ft
1
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000391
1657.2 90.92 170.69 .1312
7
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency Capacity
Block
Ducts
1
Electric Strip Heat/ None
COP:1 23 kBtulhr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit)
Split
Singl SEER: 16 29.4 kBtulhr
cfm 0.71 1
sys#1
6/16/2021 8:18 AM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5
FORM R405-2020
# System Type SubT
1 Electric None
FSEC
Cert # Company Name
None None
SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
Location EF Cap Use SetPnt Conservation
Garage 0.95 40 gal 60.9 gal 120 deg None
SOLAR HOT WATER SYSTEM
Collector Storage
System Model # Collector Model # Area Volume FEF
ft2
DUCTS
/ ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC #
1/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool
1 Attic 6 300 ft2 HALL BATH 1 W Default Leakage HALL BAT (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan
Heatinf X�
Jan f
]Feb
X] Feb
f
Mar
Mar
f
Apr
Apr
I
May
May
ri
Jun
Jun
Jul
Jul
rl
AuSep
rj Aug
Se
Oct
Oct ki
�xl
Nov
Nov
Dec
Dec
H
Venting [
Jan [
j Feb
Xj
[X
Mar
[7C
A r
May
Jun
Jul
Aug
Se
Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
Oft
0.3
BED 3
Default(8 lbs/sq.ft.
ft2
ft
0.3
HALL BATH
Default(8 [bs/sq.ft.
ft2
ft
0.3
FOYER
Default(8 [bs/sq.ft.
ft2
ft
0.3
BED 4
Default(8 lbs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default(8 [bs/sq.ft,
ft2
ft
0.3
BED 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
GRT DIN KITCHEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
MASTER SUITE
Default(8 [bs/sq.ft.
ft2
ft
0.3
MAST WIC
Default 8 Ibs/s .ft.
ft2
ft
0.3
M BATH
6/16/2021 8:18 AM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 5
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows- Description
a. U-Factor: Dbl, U=0.28
SHGC: SHGC=0.30
b. U-Factor. Dbl, U=0.55
SHGC: SHGC=0.34
c. U-Factor: NIA
SHGC:
d. U-Factor. NIA
SHGC:
Area Weighted Average Overhang Depth
Area Weighted Average SHGC:
8. Skylights Description
a. U-Factor(AVG): N/A
SHGC(AVG): NIA
9. Floor Types
a. Slab -On -Grade Edge Insulation
b. NIA
c. NIA
5126 ARMINA PLACE, FT PIERCE, FL,
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
Detached
a. Concrete Block - int Insul, Exterior
R=4.1
1516.70 ft2
b. Frame - Wood, Adjacent
R=11.0
280.00 ftz
1
c. NIA
R=
ftz
4
d. NIA
R=
ft2
No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
1618.00 ftz
1616
b. NIA
R=
ft2
Area
c. NIA
R=
ft2
113.92 ftz
12. Ducts, location & insulation level
R ft2
a. Sup: Attic, Ret: HALL BATH, AH: HALL
BATH
6 300
41.00 ft2
13. Cooling systems
kBtulhr
Efficiency
ftz
a. Central Unit
29.4
SEER:16.00
ft2
4.909 ft.
0.311
Area
ft2
Insulation Area
R=0.0 1616.00 ft2
R= ft2
R= ftz
14. Heating systems
a. Electric Strip Heat
15. Hot water systems
a. Electric
b. Conservation features
None
Credits (Performance method)
certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
kBtulhr Efficiency
23.0 COPA.00
Cap: 40 gallons
EF: 0.95
Pstat
Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
611612021 8:1 a AM EnergyGaugeV USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1