Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Energy Efficiency Code
FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: MOORE AND VASSEL RESIDENCE Builder Name: Street: 7960 PLANTATION LAKES DRIVE Permit Office: ST LUCIE COUNTY City, State, Zip: PORT ST LUCIE, FL, Permit Number: Owner: JASON MOORE AND KAREN VASSELL Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or ebsting New (From Plans) 9. Wall Types (3238.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Polystyrene Bead AggrER=0.0 2754.00 ft2 b. Frame - Wood, Adjacent R=19.0 484.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 10. Ceiling Types (3681.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 3681.00 ft2 6. Conditioned floor area above grade (ft2) 3681 b. N/A R= ft2 c. R= ft2 Conditioned floor area below grade (ft2) 0 11. Ducts R ft2 7: Windows(541.3 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 175 a. U-Factor: Sgl, U=0.33 293.33 ft2 b. Sup: Attic, Ret: Attic, AH: Attic 6 130 SHGC: SHGC=0.20 b. U-Factor: Sgl, U=0.26 92.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.24 a. Central Unit 41.0 SEER:16.00 b. Central Unit 24.0 SEER:16.00 c. U-Factor: Sgl, U=0.32 84.00 ft2 SHGC: SHGC=0.24 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 72.00 ft2 a. Electric Strip Heat 27.0 COP:1.00 SHGC: other (see details) b. Electric Strip Heat 17.0 COP:1.00 Area Weighted Average Overhang Depth: 8.097 ft. Area Weighted Average SHGC: 0.215 14. Hot water systems a. Natural Gas Tankless Cap: 1 gallonsEF: 8. Floor Types (3681.0 sgft.) Insulation Area 0.800 a. Slab -On -Grade Edge Insulation R=0.0 3681.00 ft2 b. Conservation features b. N/A R= fe None c. N/A R= ft2 15. Credits None Total Proposed Modified Loads: 112.89 Glass/Floor Area: 0.147 PASS Total Baseline Loads: 113.90 I hereby certify that the plans and specifications covered by Review of the plans and 'VIIE'STgr this calculation are,in compliance with the Florida Energy specifications covered by this ti_ 0,�, Code. calculation indicates compliance �O with the Florida Energy Code. rnra• ''� �; �� PREPARE Bxx ��-L4- Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 Q,.rk i`r * �, I hereby certify that this buildi9o, as designed, is in compliance Florida Statutes. COD with the Florida Energy Co W>ry OWNER/AGE N BUILDING OFFICIAL: DATE: Z DATE: - Compliance requires certification by the air handler -unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 11/24/2020 10:36 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 8 FORM R405-2017 INFU I SUMMAKY C HLUKLIJ I Ktt'UK I PROJECT Title: MOORE AND VASSEL RESI Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 3681 Lot # Owner Name: JASON MOORE AND KAREN Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 7960 PLANTATION LA Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: PORT ST LUCIE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 AHU 1 2401 25650 2 AHU 2 1280 14058 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 KITCHEN 289 2890 Yes 0 1 Yes Yes Yes 2 BEDROOM 4 236 2360 No 0 1 1 Yes Yes Yes 3 BATH 4 97 970 No 0 1 Yes Yes Yes 4 NOOK 80 800 No 0 1 Yes Yes Yes 5 HALL 40 400 No 0 1 No Yes Yes 6 WIC 3 35 350 No 0 1 No Yes Yes 7 WIC 4 40 400 No 0 1 Yes Yes Yes 8 BEDROOM 3 220 2200 No 0 1 1 Yes Yes Yes 9 BATH 3 90 900 No 0 1 Yes Yes Yes 10 BATH 2 90 900 No 0 1 Yes Yes Yes 11 HALLWAY 72 720 No 0 1 No Yes Yes 12 POWDER RM 42 420 No 0 1 No Yes Yes 13 CLST 2 16 160 No 0' 1 No Yes Yes 14 BEDROOM 2 172 1720 No 0 1 1 Yes Yes Yes 15 LAUNDRY RM 100 1000 No 0 1 No Yes Yes 16 DINING RM 224 2688 No 0 1 Yes Yes Yes 17 FOYER 80 1120 No 0 1 Yes Yes Yes 18 GREAT RM 436 5232 No 0 1 Yes Yes Yes 19 PANTRY 42 420 No 0 1 No Yes Yes 20 M HALL 65 650 No 0 1 No Yes Yes 21 M BATH 229 2290 No 0 1 Yes Yes Yes 11/24/2020 10:36 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 8 FORM R405-2017 INIJU I SUIVIMAKY (;MLUKLI, I KLVUK I SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 22 M TOILET 20 200 No 0 1 Yes Yes Yes 23 M WIC 169 1690 No 0 1 Yes Yes Yes 24 MASTER BEDROO 473 5676 No 0 1 1 Yes Yes Yes 25 FLEX RM 168 1680 No 0 1 Yes Yes Yes 26 DEN 156 1872 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation KITCHEN 1 ft 0 289 ft2 _-__ 1 0 0 2 Slab -On -Grade Edge Insulation. BEDROOM 4 33 ft 0 236 ft2 ___- 1 0 0 3 Slab -On -Grade Edge Insulation ''BATH 4 13 ft 0 97 W _--_ 1 0 0 4 Slab -On -Grade Edge Insulation NOOK 18 ft 0 80 ft2 ---_ 1 0 0 5 Slab -On -Grade Edge Insulation HALL 1 ft 0 40 ft2 -___ 1 0 0 6 Slab -On -Grade Edge Insulation WIC 3 1 ft 0 35 ft2 ___- 1 0 0 7 Slab -On -Grade Edge Insulation WIC 4 5 ft 0 40 ft2 _--_ 1 0 0 8 Slab -On -Grade Edge Insulation BEDROOM 3 12 ft 0 220 ft2 ____ 1 0 0 9 Slab -On -Grade Edge Insulation BATH 3 5 ft 0 90 W ___- 1 0 0 10SIab-On-Grade Edge Insulation _ BATH 2 11 ft 0 90 ft2 __-- 1 0 0 11SIab-On-Grade Edge Insulation HALLWAY 1 ft 0 72 ft2 ____ 1 0 0 12SIab-On-Grade Edge Insulation POWDER RM 1 ft 0 42 ft2 _--_ 1 0 0 13SIab-On-Grade Edge Insulation CLST 2 1 ft 0 16 ft2 ---- 1 0 0 14SIab-On-Grade Edge Insulation BEDROOM 2 12 ft 0 172 ft2 ___- 1 0 0 15SIab-On-Grade Edge Insulation LAUNDRY RM 1 ft 0 100 ft2 __-_ 1 0 0 16SIab-On-Grade Edge Insulation DINING RM 19 ft 0 224 ft2 ____ 1 0 0 17SIab-On-Grade Edge Insulation FOYER 8 ft 0 80 ft2 -_-- 1 0 0 18SIab-On-Grade Edge Insulation GREAT RM 20 ft 0 436 ft2 ---- 1 0 0 19SIab-On-Grade Edge Insulation PANTRY 1 ft 0 42 ft2 _-__ 1 0 0 20SIab-On-Grade Edge Insulation M HALL 1 ft 0 65 ft2 -__- 1 0 0 21SIab-On-Grade Edge Insulation M BATH 7 ft 0 229 ft2 ____ 1 0 0 22SIab-On-Grade Edge Insulation M TOILET 5 ft 0 20 ft2 -_-_ 1 0 0 23SIab-On-Grade Edge Insulation M W IC 13 ft 0 169 ft2 __-_ 1 0 0 11/24/2020 10:36 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 8 i:nRnn PAns_7n17 INPUT RUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 24SIab-On-Grade Edge Insulation MASTER BEDRO 44 ft 0 473 ft2 ____ 1 0 0 25SIab-On-Grade Edge Insulation FLEX RM 8 ft 0 168 ft2 _--- 1 0 0 26SIab-On-Grade Edge Insulation DEN 18 ft 0 156 ft2 _-__ 1 0 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 4117 ft' 0 ft2 Medium N 0.3 No 0.9 No 20 26.6 ATTIC IRCC V # Type Ventilation Vent Ratio (1 in) Area RBS 1 Full attic Unvented 0 3681 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) KITCHEN 0 Blown 289ft2 0.1 Wood 2 Under Attic (Unvented) BEDROOM 4 0 Blown 236 ft2 0.1 Wood 3 Under Attic (Unvented) BATH 4 0 Blown 97 ft2 0.1 Wood 4 Under Attic (Unvented) NOOK 0 Blown 80 W 0.1 Wood 5 Under Attic (Unvented) HALL 0 Blown 40 ft2 0.1 W ood 6 Under Attic (Unvented) WIC 3 0 Blown 35 ft2 0.1 Wood 7 Under Attic (Unvented) WIC 4 0 Blown 40 ft2 0.1 Wood 8 Under Attic (Unvented) BEDROOM 3 0 Blown 220 ft2 0.1 Wood 9 Under Attic (Unvented) BATH 3 0 Blown 90 ft2 0.1 Wood 10 Under Attic (Unvented) BATH 2 0 Blown 90 ft2 0.1 Wood 11 Under Attic (Unvented) HALLWAY 0 Blown 72ft2 0.1 Wood 12 Under Attic (Unvented) POWDER RM 0 Blown 42ft2 0.1 Wood 13 Under Attic (Unvented) CLST 2 0 Blown 16 ft2 0.1 Wood 14 Under Attic (Unvented) BEDROOM 2 0 Blown 172 ft2 0.1 Wood 15 Under Attic (Unvented) LAUNDRY RM 0 Blown 100 ft2 0.1 Wood 16 Under Attic (Unvented) DINING RM 0 Blown 224 112 0.1 Wood 17 Under Attic (Unvented) FOYER 0 Blown 80 ft2 0.1 Wood 18 Under Attic (Unvented) GREAT RM 0 Blown 436 ft2 0.1 Wood 19 Under Attic (Unvented) PANTRY 0 Blown 42 ft2 0.1 Wood 20 Under Attic (Unvented) M HALL 0 Blown 65 ft2 0.1 Wood 21 Under Attic (Unvented) M BATH 0 Blown 229 ft2 0.1 Wood 22 Under Attic (Unvented) M TOILET 0 Blown 20 ft2 0.1 Wood 23 Under Attic (Unvented) M WIC 0 Blown 169 W 0.1 Wood 24 Under Attic (Unvented) MASTER BEDRO -0 Blown 473 ft2 0.1 Wood 25 Under Attic (Unvented) FLEX RM 0 Blown 168 ft2 0.1 Wood 26 Under Attic (Unvented) DEN 0 Blown 156 ft2 0.1 Wood 11/24/2020 10:36 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 8 FnRnn RAnr,_gn17 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 N Exterior Concrete Block - PolystyreKibTCHEN 0 1 0 10 0 10.0 ft2 0 0 0.3 0 2 S Exterior Concrete Block - PolystyMIDROOM 4 0 14 0 10 0 140.0 ft2 0 0 0.3 0 _ 3 W Exterior Concrete Block - PolystyREEDROOM 4 0 19 0 10 1 0 190.0 ft2 0 0 0.3 0 _ 4 N Exterior Concrete Block - PolystyrenBATH 4 0 6 0 10 0 60.0 ft2 0 0 0.3 0 5 W Exterior Concrete Block - PolystyrenBATH 4 0 7 0 10 0 70.0 ft2 0 0 0.3 0 6 N Exterior Concrete Block - Polystyren(NOOK 0 8 0 10 0 80.0 ft2 0 0 0.3 0 _ 7 W Exterior Concrete Block - Polystyren(NOOK 0 10 0 10 0 100.0 ft2 0 0 0.3 0 8 S Exterior Concrete Block - PolystyrendNIC 4 0 5 0 10 0 50.0 ft2 0 0 0.3 0 9 S Exterior Concrete Block - Polysty&El)ROOM 3 0 12 0 10 0 120.0 ft2 0 0 0.3 0 10 S Exterior Concrete Block - PolystyrenBATH 3 0 5 0 10 0 50.0 ft2 0 0 0.3 0 11 E Exterior Concrete Block - PolystyrenBATH 2 0 6 0 10 0 60.0 ft2 0 0 0.3 0 12 S Exterior Concrete Block - PolystyrenBATH 2 0 5 0 10 0 50.0 ft2 0 0 0.3 0 13 E Garage Frame - Wood CLST 2 19 2 0 10 0 20.0 ft2 0 0.1 0.3 0 1,4 S Exterior Concrete Block - PolystyMBROOM 2 0 12 0 10 0 120.0 ft2 0 0 0.3 0 15 E Garage Frame - Wood BEDROOM 2 19 13 0 10 0 130.0 ft2 0 0.1 0.3 0 16 E Garage Frame - Wood LAUNDRY R 19 9 0 10 0 90.0 ft2 0 0.1 0.3 0 17 N Exterior Concrete Block - PolystyrOiNING RM 0 6 0 12 0 72.0 ft2 0 0 0.3 0 18 E Exterior Concrete Block - Polystyr@%ING RM 0 13 0 12 0 156.0 ft2 0 0 0.3 0 _ 19 E Garage Frame - Wood DINING RM 19 1 0 12 0 12.0 ft2 0 0.1 0.3 0 20 E Exterior Concrete Block - Polystyren€DYER 0 8 0 14 0 112.0 ft2 0 0 0.3 0 21 W Exterior Concrete Block - PolystyrG-REAT RM 0 20 0 12 0 240.0 ft2 0 0 0.3 0 22 N Exterior Concrete Block - PolystyrerM BATH 0 7 0 10 0 70.0 ft2 0 0 0.3 0 23 E Garage Frame - Wood M BATH 19 16 0 10 0 160.0 ft2 0 0.1 0.3 0 24 S Garage Frame - Wood M BATH 19 1 0 10 0 10.0 ft2 0 0.1 0.3 0 25 N Garage Frame - Wood M BATH 19 1 0 10 0 10.0 ft2 0 0.1 0.3 0 26 N Exterior Concrete Block - Polystyretul TOILET 0 5 0 10 0 50.0 ft2 0 0 0.3 0 27 E Garage Frame - Wood M TOILET 19 4 0 10 0 40.0 ft2 0 0.1 0.3 0 28 N Exterior Concrete Block - PolystyrenM W IC 0 13 0 10 0 130.0 ft2 0 0 0.3 0 29 N Exterior Concrete Block - PolystyTER BE 0 18 0 12 0 216.0 ft2 0 0 0.3 0 30 S Exterior Concrete Block - PolystyTER BE 0 5 0 12 0 60.0 ft2 0 0 0.3 0 31 W Exterior Concrete Block - Polys~TER BE 0 21 0 12 0 252.0 ft2 0 0 0.3 0 32 W Exterior Concrete Block - PolystyreftLEX RM 0 8 0 10 0 80.0 ft2 0 0 0.3 0 33 E Exterior Concrete Block - PolystyreneDEN 0 12 0 12 0 144.0 ft2 0 0 0.3 0 34 S Exterior Concrete Block - PolystyreneDEN 0 6 0 12 0 72.0 ft2 0 0 0.3 0 35 E Garage Frame - Wood DEN 19 1 0 12 0 12.0 ft2 0 0.1 0.3 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Insulated LAUNDRY R None .23 2 8 8 21.3 ft2 11/24/2020 10:36 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 8 GnRnn Rdn1;_'Dn17 IMPI IT Al IMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 2 Vinyl Low-E Single Yes 0.3 0.21 Y 15.0 ftZ 1 ft 4 in 1 ft 4 in None None 2 W 3 Vinyl Low-E Single Yes 0.3 0.21 Y 15.0 ft' 1 ft 4 in 1 ft 4 in None None 3 N 4 Vinyl Low-E Single Yes 0.33 0.2 Y 21.3 ft' 8 ft 4 in 1 ft 4 in None None 4 W 7 Vinyl Low-E Single Yes 0.26 0.24 Y 40.0 ftZ 8 ft 4 in 1 ft 4 in None None 5 S 9 Vinyl Low-E Single Yes 0.3 0.21 Y 15.0 ft' 1 ft 4 in 1 ft 4 in None None 6 S 10 Vinyl Low-E Single Yes 0.26 0.24 Y 6.0 ftZ 1 ft 4 in 1 ft 4 in None None 7 S 12 Vinyl Low-E Single Yes 0.26 0.24 Y 6.0 ftZ 1 ft 4 in 1 ft 4 in None None 8 S 14 Vinyl Low-E Single Yes 0.3 0.21 Y 15.0 ftZ 1 ft 4 in 1 ft 4 in None None 9 E 18 Vinyl Low-E Single Yes 0.32 0.24 Y 42.0 ftZ 1 ft 4 in 1 ft 4 in None None 10 E 20 Vinyl Low-E Single Yes 0.33 0.2 Y 48.0 ftZ 8 ft 4 in 1 ft 4 in None None 11 W 21 Vinyl Low-E Single Yes 0.33 0.2 Y 128.0 ftZ 15 ft 4 in 1 ft 4 in None None 12 N 22 Vinyl Low-E Single Yes 0.26 0.24 Y 8.0 ftZ 1 ft 4 in 1 ft 4 in None None 13 N 28 Vinyl Low-E Single Yes 0.26 0.24 Y 16.0 ftZ 1 ft 4 in 1 ft 4 in None None 14 N 29 Vinyl Low-E Single Yes 0.28 0.24 Y 12.0 ftZ 1 ft 4 in 1 ft 4 in None None 15 N 29 Vinyl Low-E Single Yes 0.26 0.24 Y 16.0 ftZ 1 ft 4 in 1 ft 4 in None None 16 W 31 Vinyl Low-E Single Yes 0.33 0.2 Y 48.0 ftZ 10 ft 4 in 1 ft 4 in None None 17 W 32 Vinyl Low-E Single Yes 0.33 0.2 Y 48.0 ftZ 15 ft 4 in 1 ft 4 in None None 18 E 33 Vinyl Low-E Single Yes 0.32 0.24 Y 42.0 ftZ 1 ft 4 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 2500 ftZ 2500 ftZ 48 ft - loft 19 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) 00048 4632.6 254.32 478.29 .1874 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1 2 Electric Strip Heat/ None COP:1 17 kBtu/hr 2 sys#2 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 16 41 kBtu/hr 1230 cfm 0.8 1 sys#1 2 Central Unit/ Split Single SEER: 16 24 kBtu/hr 720 cfm 0.8 2 sys#2 11/24/2020 10:36 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 8 FORM R4t15-gn17 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Natural Gas Tankless Exterior 0.8 1 gal 55.1 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ftZ DUCTS --- Supply -- -- Return --- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 175 ftZ Attic 18 ftZ Default Leakage Attic (Default) c(Default) c 1 1 2 Attic 6 130 ftZ Attic 13 ftZ Default Leakage Attic (Default) c(Default) c 2 2 TEMPERATURES Programable Thermostat: N Ceiling Fans: CoolingJan Feb HeatinJan Feb Mar Mar Apr f Apr May f May [ ] Jun Jul J1 Jun Jul [X] AugX] [ ] Au[ Se ] Sep Oct f Oct Nov Nov Dec Dec Ventin Jan Feb Mar [X] Apr [ may [ ] Jun Jul [ ] Aug [ ] Se X [X] Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (W D) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ftZ ft 0.3 BEDROOM 4 Default(8 Ibs/sq.ft. ftZ ft 0.3 BATH 4 Default(8 Ibs/sq.ft. ftZ ft 0.3 NOOK Default(8 Ibs/sq.ft. ftZ ft 0.3 HALL Default(8 Ibs/sq.ft. ftZ ft 0.3 WIC 3 Default(8 Ibs/sq.ft. ft, ft 0.3 WIC 4 Default(8 Ibs/sq.ft. ftZ ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ftZ ft 0.3 BATH 3 Default(8 Ibs/sq.ft. ftZ ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ftZ ft 0.3 HALLWAY Default(8 Ibs/sq.ft. ftZ ft 0.3 POWDER RM Default(8 Ibs/sq.ft. ftZ ft 0.3 CLST 2 - Default(8 Ibs/sq.ft. ftZ ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ftZ ft 0.3 LAUNDRY RM 11/24/2020 10:36 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. ft2 ft 0.3 DINING RM Default(8 Ibs/sq.ft. ft2 ft 0.3 FOYER Default(8 Ibs/sq.ft. ft2 ft 0.3 GREAT RM Default(8 Ibs/sq.ft. ft2 ft 0.3 PANTRY Default(8 Ibs/sq.ft. ft2 ft 0.3 M HALL Default(8 Ibs/sq.ft. ft2 ft 0.3 M BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 M TOILET Default(8lbs/sq.ft. ft2 ft 0.3 M WIC Default(B Ibs/sq.ft. ft2 ft 0.3 MASTER BEDR00 Default(8 Ibs/sq.ft. ft2 ft 0.3 FLEX RM Default(8 Ibs/s .ft. ft2 ft 0.3 DEN 11/24/2020 10:36 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 8 of 8