-F- wrightsoft° Duct System Summary AHU 2 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 0"roject intormation For: JASON MOORE AND KAREN VASSELL, HOMES BYABURTON 7960 PLANTATION LAKES DRIVE, PORT ST LUCIE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/ 100ft 800 cfm Job: Date: Nov 23, 2020 By: Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 800 cfm 137 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk DEN c 3639 148 167 1.000 8.0 Ox 0 VIFx 22.4 115.0 st4 FLEX RM c 2083 38 96 1.000 7.0 Ox 0 VIFx 16.7 115.0 st3 FLEX RM-A C 2083 38 96 1.000 7.0 Ox 0 VIFx 15.2 115.0 st3 M BATH c 1476 67 68 1.000 6.0 Ox 0 VIFx 8.3 115.0 st4 M TOILET h 709 33 28 1.000 5.0 Ox 0 VIFx 16.5 115.0 st4 M W i c h 2132 101 49 1.000 6.0 Ox 0 VIFx 8.1 115.0 st4 MASTER BEDROOM h 3956 187 148 1.000 8.0 Ox 0 VIFx 9.2 115.0 st3 MASTER BEDROOM -A h 3956 187 148 1.000 8.0 Ox 0 VIFx 13.5 115.0 st3 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st4 Peak AVF 349 313 1.000 791 9.0 0 x 0 VinlFlx st3 Peak AVF 451 487 1.000 620 12.0 0 x 0 VinlFlx Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox0 800 800 0 0 0 0 Ox 0 VIFx 1 -�- wrightsoft- •• -•++ •r Right -Suite@ Universal 2019 19.0.08 RSU08101 ...\Wrightsoft HVAC\MOORE AND VASSEL RESIDENCE.rup Calc = MJ8 Front Door faces: E 2020-Nov-23 21:24:06 Page 3 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st6 Peak AVF 268 372 1.000 682 10.0 0 x 0 VinlFlx st5 st5 Peak AVF 657 640 1.000 837 12.0 0 x 0 VinlFlx st2 st2 Peak AVF 888 816 1.000 831 14.0 0 x 0 VinlFlx st1 Peak AVF 468 510 1.000 649 12.0 0 x 0 VinlFlx Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb2 Ox 0 1367 1367 0 0 0 0 Ox 0 VIFx wrightsoft- 2020-Nov-23 21:24:06 A.�*.• M ,..ex M..,• mMry Right -Suite@ Universal 2019 19.0.08 RSU08101 Page 2 ...\Wrightsoft WAMMOORE AND VASSEL RESIDENCE.rup Calc = MJ8 Front Door faces: E -- wrightsoft° Duct System Summary AHU 1 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS ,AOL.COM eLroject intormation For: JASON MOORE AND KAREN VASSELL, HOMES BY ABURTON 7960 PLANTATION LAKES DRIVE, PORT ST LUCIE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/ 100ft 1367 cfm Job: Date: Nov 23, 2020 By: Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 1367 cfm 202 ft Name Design (Btuh) Htg� (cfm) Cig (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH 2 h 1825 82 36 1.000 5.0 Ox 0 VIFx 18.2 115.0 st2 BATH 3 h 940 42 22 1.000 5.0 Ox 0 VIFx 18.8 115.0 st2 BATH 4 h 2192 99 47 1.000 6.0 Ox 0 VIFx 45.8 155.0 st6 BEDROOM 2 c 2554 100 112 1.000 7.0 Ox0 VIFx 13.9 115.0 st2 BEDROOM 3 c 2631 103 116 1.000 7.0 Ox 0 VIFx 31.2 135.0 st5 BEDROOM 4 h 5436 246 134 1.000 7.0 Ox 0 VIFx 37.7 135.0 st5 DINING RM h 3654 165 108 1.000 7.0 Ox 0 VIFx 21.1 115.0 st1 FOYER c 2441 83 107 1.000 7.0 Ox 0 VIFx 17.2 115.0 st1 GREAT RM c 3303 107 145 1.000 8.0 Ox 0 VIFx 20.2 115.0 st1 GREAT RM-A c 3303 107 145 1.000 8.0 Ox 0 VIFx 26.6 115.0 st1 KITCHEN c 2455 18 108 1.000 7.0 Ox 0 VIFx 46.3 155.0 st6 KITCHEN -A c 2455 18 108 1.000 7.0 Ox 0 VIFx 40.7 155.0 st6 LAUNDRY RM c 941 11 41 1.000 6.0 Ox 0 VIFx 3.6 95.0 NOOK h 2954 133 109 1.000 7.0 Ox 0 VIFx 47.2 155.0 st6 PANTRY h 112 5 5 1.000 4.0 Ox 0 VIFx 20.8 115.0 SO POWDER RM h 132 6 5 1.000 4.0 Ox 0 VIFx 13.2 115.0 st2 WIC 3 h 88 4 4 1.000 4.0 Ox 0 VIFx 31.1 135.0 st5 WIC 4 h 810 37 15 1.000 4.0 Ox 0 VIFx 33.7 135.0 st5 * wrightsoft- 'Z�-- Right -Suite® Universal 2019 19.0.08 RSU08101 ...\Wrightsoft HVAC\MOORE AND VASSEL RESIDENCE.rup Calc = MJ8 Front Door faces: 2020-Nov-23 21:24:06 Page 1 -1- wrightsoft° Project Summary AHU 1 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM For: Notes: Job: Date: Nov 23, 2020 By: 79 0 PLANT ATTION LAKES DRIVE, POR f STT LUCIE, FLBURTON Weather: Winter Design Conditions Outside db 42 °F Inside db 70 °F Design TD 28 °F Heating Summary Structure 22916 Btuh Ducts 7339 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 30255 Btuh Infiltration Method Construction quality Fireplaces Fort Pierce, FL, US Simplified Average 0 Heating Cooling Area (ftz) 2401 2401 Volume (ft3) 25650 25650 Air changes/hour 0.26 0.14 Equiv. AVF (cfm) 113 61 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 8.3 kW 28346 Btuh 9 0 F 1367 cfm 0.045 cfm/Btuh 1.00 in H2O Summer Design Conditions Outside db 90 °F Inside db 75 °F Design TD 15 °F Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 20754 Btuh Ducts 10337 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 29537 Btuh Latent Cooling Equipment Load Sizing Structure 3530 Btuh Ducts 2860 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 6389 Btuh Equipment Total Load (Sen+Lat) 35926 Btuh Req. total capacity at 0.70 SHR 3.5 ton Cooling Equipment Summary Make Trane Trade TRANE Cond 4TTR6042J 1 Coil TEM4AOC42S41++TDR AHRI ref 8703699 Efficiency 13.0 EER, 16 SEER Sensible cooling 28700 Btuh Latent cooling 12300 Btuh Total cooling 41000 Btuh Actual airflow 1367 cfm Air flow factor 0.044 cfm/Btuh Static pressure 1.00 in H2O Load sensible heat ratio 0.83 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -*- wrightsoft� 2020-Nov-23 21:23:58 Right -Suite® Universal 2019 19.0.08 RSU08101 Page 1 fil. ...\Wrightsoft WAC\MOORE AND VASSEL RESIDENCE.rup Calc = MJ8 Front Door faces: E Pro ect Summa Job: - -F'�- wrightsoft® AiHU 2 � Byte: Nov 23, zozo QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@/\OL.COM Project• • For: 79 0 PLANTATION LAKES DRIVE, PORt STT HOMES BY FLBURTON N otes: Design Information r Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 13893 Btuh Structure 12984 Btuh Ducts 3034 Btuh Ducts 4399 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 16927 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 16514 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3617 Btuh Ducts 1159 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) 4776 Btuh Area (ftZ) 1280 1280 Equipment latent load Volume (ft3) 14058 14058 Air changes/hour 0.31 0.17 Equipment Total Load (Sen+Lat) 21290 Btuh Equiv. AVF (cfm) 72 39 Req. total capacity at 0.70 SHR 2.0 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR40251_1 AHRI ref -Coil TEM6AOB24H21++TDR AH R I ref 7567540 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 4.7 kW Sensible cooling 16800 Btuh Heating output 15914 Btuh Latent cooling 7200 Btuh Temperature rise 18 OF Total cooling 24000 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.047 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.78 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 1 -F�6- !nfwr1oht25oft_ 2020-Nov-23 21:23:58 MCA ^ • ^ Right -Suite® Universal 2019 19.0.08 RSU08101 Page 2 ...Mrightsoft WAC\MOORE AND VASSEL RESIDENCE.rup Calc = MJ8 Front Door faces: E