Loading...
HomeMy WebLinkAboutKillday Shari - Shawn Signed Building Permit CPSL� 7 ST. LUCIE WORKS ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code - Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: :RjoofSystem Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A, B, C 1,2,3,4,5,6,7 2,4,5,6,7 Prescriptive BUR-RAS 150 A, B, C Asphaltic Shingles A, B, D 1,2,4,5,6,7 A, B, D, E 1,2,3,4,5,6,7 rak' A, B, D A, B, D 1,2,4,5,6,7 As Applicable 1,2A4,5,6,7 nTTArHMENTS REQUIRED As Applicable): 1. Fire Directory Listing Page 2, From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3, Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application Owners Notification for Roofing Considerations (Reroofing Only) Any Required Roof Testing/Calculation Documentation 6. 7, Form Roof1nfoFeb21 Rev Feb 18, 2021 Sao LU I Master Permit No Contractors Name: Shawn Wolfe Section A (General Information) Process No. License # CM 330245 Job Address 909 Jackson Way, Fort Pierce, FL 34949 ROOF CATEGORY XX1,ow Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tiles ❑ Asphaltic Shingles ❑ Metal Panel/Shingles ❑Wood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE. ❑ New roof ❑ Repair ❑ Maintenance Reroofing ❑ Recovering ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) I -I"' Steep Sloped Roof Area (SF) Total (SF) Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. 1v.Vg 1UAM N 00 w 49,9 40*zi VC19 L h.1 ST. LUCIE WORKS Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: CIL J�ca' Product Approval No.: F`- 2 S3 3— dk Z Q Design Wind Pressures, From RAS 128 Or Calculations: Zone 1': �0 Zone 1: 1, W Zone 2: Q W Zone 3: I t <- Max. Design Pressure, from the specific product approval system: 1 Z % ► S Deck: �► I Type. 5% G,(� A, 0 yaa'o d Gauge Thickness: Slope: /q ' Anchor/Base Sheet & No. df Ply(s): Anchor/Base Sheet Fastennelr/B° ding Material: Insulation Base Layer: .E'-r-4 V 3 Base Insultation Size and Thickness ► • S" N ,c 4 o r H-A >i Base Insulation Fastener/Bonding Material: Top Insulation Layer: 7---Yle.r Y J Top Insulation Size and Thickness: TT ,� fvWs Top Insulation Fastener/Bonding Material: =1"1 Z a r t--y I w 7" Base Sheet(s) & No. of Ply(s): Base Sheet Fastener/Bonding 74 ri/VV Ply Sheet(s)' & No. of Ply(s): S 6 S - . Ply Sheet Fastenerr/BondingtMaterial: Top Ply: Top Ply Fastener/Bonding Material: l� Surfacing: Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1':g " oc @ Lap, # Rows �- Is "oc Zone 1: " oc @ Lap, # Rows Z @ g " oc Zone 2: G~ if oc @ Lap, # Rows 3 @ oc Zone 3: " oc @ Lap, # Rows 1-4 @" oc Number of Fasteners Per Insulation Board: Zone 1': Zone 1: L Zone 2: Zone 3: Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterf lashing, Coping, Etc., Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16.. ST. LUCIE WORKS Section D (Steep Slope Roof System) C Roof System Manufacturer: � M J `� Notice of Acceptance Number: _ r 1, l ? 0 2 2� Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): Zone 1: 5 ✓ Zone 2e: Zone 2n: 41 Zone 2r: ! I Zone 3e: � ` Zone 3r: Z-� Deck Type: 1 ' /g " (; b >( P) ove)c' a Type Underlayment: Roof Slope: 12 Insulation: (�- Fire Barrier: 81 Ridge Ve"A, n? Fastener Type &Spacing: �'�� C, ; l Now` -�' �S S Adhesive Type: a Mean Roof Height: �) Z Type Cap Sheet: \ Roof Covering: s V Type & Size Drip ENZE=1 Edge: ST. LUCIE WORKS Section E (Tile Calculations) For Moment based the systems, choose either Method 1 or 2. Compare the values for Mr with the values from Mf. If the Mf values are greater than or equal to the Mrvalues, for each area of the roof, then the the attachment method is acceptable. Method 1'Moment Based Tile Calculations Per RAS 12T (Zone 1: x = ) - Mg: = M', Product Approval M� (Zone 2e: x = _ - Mg' = M,2. Product Approval Mf (Zone 2n: x )L = _� -- Mg: = Mz, Product Approval Mf (Zone 2r: x = —� - Mg: = M& roduct Approval Mf (Zone 3e: x _ —a "' Mg: = M Product Approval Mf (Zone 3r: x _ -----7 - Mg: = Mr Product Approval Mf Method 2 "Simplified Tile Calc ations Per Table Below" r^A! rt �nnrnval Mf iequirea fviornenL vl nCDIJLCIII .0 11 4, . Mr req ed Mom nt sistance* Mean Roof Height Roof Slope 2:12 15' 34.4 20' 36.5 25' 8.2 30' 39.7 40' 42.2 3:12 32.2 4. .0 37.4 39.8 4:12 3 .4 .2 3 .8 35.1 37.3 5:12 28 .1 316 32.8 34.9 6:12 26 280 29. 30.5 32.4 7:12 24. 25. 28.2 30.0 *Must be used in conjunction witn a us, • For Uplift based tile systems use Meth equal to the Fr values, for each area of (Zone 1: x L =x W:=_ (Zone 2e: x L =x W:= n are the III �pf, t en the tileli 3 lU lift Based Ti N; cos r W: Cos r (Zone 2n: x L =x W:= ) - cos r (Zone 2r: x L =x W: ) - cos r (Zone 3e: x L =x W.= ) -W: cos r (Zone 3r: x L =x W :_ ) -W: cos r kF' �ith the values for Fr If the F' values are greater than or ment method is acceptable. ulations Per RAS 12T - r1 Product Approval F' r2e Product Approval F' - r2n Product Approval F' =Fr2r Product Approval F' =Free Product Approval F' =Frar Product Approval F' Where to Obtain Information Description Symbol Where to find From applicable table in RAS 127 or by an engineering analysis Design Pressure Zones 1, 2e, 2n, 2r, 3e, 3r prepared by PE based on ASCE 7 Job Site Mean Roof Height H Roof Slope 6 Job Site Aerodynamic Multiplier A Product Approval Restoring Moment due o Gravity Mg Product Approval Attachment Resistant Mf Product Approval Required Moment Re istance MB Calculated Minimum Attachme t Resistance F' Product Approval Required Uplift Re stance Fr Calculated Average Tile Weight W Product Approval Tile Dimensions L = length W = width Product Approval All calculations must be submitted to the building official at the time of permit application.