HomeMy WebLinkAboutAPPROVED, RaimistTDHrTotal Dynamic Head JAn �tries Calculation Worksheet Company:TOODN.SMI7HPE/INDIANWERPOOLS Job . 2020W1011 Date. 9/2T/2021 Job Name:[RAIMIST Address:[159 0C-EAW- STATE DRIVE Cify/Town:FHUNTCHINSON ISLAND State: FL Zip Code: 929t8-� Instructions: Data can only be added to the yellow cells. Steps 01 & 2 are for calculating Pool Volume in Gallons and for establishing a turnover rate In Gallons Per Minute (GPM). If the turnover rate is already established, click on the GPM cell at the end of Step N2 and input flow rate, then proceed to Step M3. Pressing the RESET button will clear all Inputed Information to start a new worksheet. Worksheet can be saved to a rile or printed for future reference. Caution: Pressing the RESET button will clear all yellow System TDH Calculation Results a L cells tostart anew worksheot File must be saved with .xlsm Total Friction Loss In Ft. of 59.05 Pool Voume Water (TO H) 9 ��. 11) ( 270 f 7.`� Ij 8,583 Total Friction Loss in PSI 25.56 If pool volume is known, enter total gallons hares 0 STEP 2 NOTE: In oni.r b compty with APSP 15, system Htratlon flow rate must Ire an least that whim provides for a Enter Maximum minimum 6 hour turnover rate, or 36 gallons per minute (gpm), iM chever is greater. Auxiliary Flow .-._.-_.. __ Rate Calculate GPM & Turnover Rato in Hours: _ y a,5e3 - 7 - -_ 75 75 Maximum Design WoMr Velocity (tt./aac.i STEP 3 NOTE: While mast ANSOAP8P standards alm maximum velocities of 6 feet per second (fps) on suceon piping and 8 fps on S dron Ski. Velocity 8 -. -- return piping, ANSIIAPSP-7 requires that total system Sow rate does not exceed the madmurn rated flow rate of the Fstetl/ard6etl -- auction outlet (drain and cover), as specified by the auction outlet manufanure. Hourn Side Velocity_ 8 .Male Total ten h / $tion Pipe. I,ec mm ndod valet) 6 f and botow 11.78 0306 _ 0,069 0.83 D.00d" -__-._ ___ 0.00 1.1 TOTAL 2.66- _75 7.95 i `Calcuialo Total Length of Return Pipe: (recommended velocity: 6 -- and below) _ _ 7.20 0_Ut19 _-0.0f3 _- ---- ---_1.88--- 0003 One I lim TOTAL 1 3.55 1 1.54 Calculate Total Numb_ar of .- FMIn (In ���H.�a z ut Total Of each �• .. .c 'u'aS Sae FitRnq n Yellow ate", Calls! '� .zuu ,\m ___ ;e;�M`t�Cil� __-____ ---_____ 0.00 _ ...... .:. : 0.00 --- __-__. - __.___.____ _------- _ 0.00 5 D.00 0.00 0.00 0.00 0.00 0 i 0 7.90 0.00 0.00 0.00 0.38 0.00 ------ - 0.00 0.00 0.00 0.00 O.W 0.110 0.00 0.00 0.00 0.00 0.00 O.W 0-00 O.W r.. 0.00 0.00 0.00 0.00 0.00 0.W -0 0.00 0.00 __-----0.00 0.000.00 0.000.000 0.00 -_ _---- TOTAL 8.37 3.62 Ste#.6:,: 7_77 Step # 8 Step /<7 rnpvtsae otREtaLii jpltKiltM .. Eyebae RMUrn EYttM'!as R � ��'�ir C aiv:A. Enter Number of Suction Outlets and Skimmers i jinpo i.tj of Q-1t s- ratirtg in Y01- Ciro,) i Step 8 WARNING: In order to comply with the Federal VGB Act, when a pool or spa is equipped with any suction outlets (drains), there must 0 0 be a minimum of 2. Refer to ANSIIAPSP-7 for specific details. ALL suction outlets, when used, must be 'VGB Compliant' and must be listed/redified as being compliant with the applicable requirments of ANSI!APSP-16, the standard for"Suction Fittings for use lit Swimming 9.00 Pools, Wading Pools. Spas, and Hot Tubs* 3.50 &50 1 Select Jandy 3-Way Valve Straight Flow Straight 'rough ize: 3 1 4.32 1.97 ---0.00 0-00 0.00 moo 0.00 1100 Select Jandy 3-Way Valve 90" Flow Size: 90* Flow 6 .44 2.79 0.00 ILOO - ------ 0.00 0.00 too Total 3-Way Valve Loss 10.76 4.06 Select Jandy 2-Way Valve Size: 2-Way Valve 0.00 ---- ---0.00 0 0.00 0.00 ll.00 0.00 Total 2-Way Valve Loss 0.00 0.00 Select Jandy Check Valve tratght rough Straight Flow Size: 0 0 0 ILOO 0.00 0.00 0.00 0.00 0.00 Select Jandy Check Vat" Flow 90' Flow Sire: 0.00 0.00 0.00 0.00 0,00 ----- ------ Total Check Volvo Loss Aw 07 0.00 Select Jandy Filter Type and Sive: ndSioc: 77fnter or Heat Pup CS100 2.90 1.26 JX1 111K 15.25 6.60 L - - - Solloa Jan if Backwash Volvo- select Water Sanitizer System: 2:1 Kv Sims Val "Pill 1W IrAtRil go- Instal Friction L ogs in Friction Loss in Norte C. z0 ft. of water, PSI L Truinear Caretaker In-flo" Valve: None 0.0 an <7-J-773_07ProSeries GENERAL DISCLAIMER: This Total Dynamic Head (TDH) calculator is intended only for estimation and illustrative purposes. It is not intended to be used for calculating TDH values to be used for actual design purposes or to demonstrate compliance with any applicable codes and standards. The TDH values for components used herein are estimated values only, based on typical pool equipment. Actual TDH values can be affected by several variables which include, but are not limited to, pipe length, variations in pipe sizes, elevation, elbows, valve design, and other restrictions that may affect flow. For proper pool & circulation system design purposes and to comply with applicable codes and standards, consult a quaiinect Uesign engineer to dot-ine accurate TDH calculations which should be based on actual equipmenticomponent data provided by the equipment/component manufacturer(s). TDH calculatons must be calculated in accordance with applicable standards such as ANSIIAPSP-7 (latest edition). maximum system flow of any system must not exceed the maximum rated flow of the listed/certified (in compliance with ANSUAPSP-16) suction outlet (drain) used on the system. Consult your federal, state and local laws, codes and standards for all applicable pool design requirements. I hereby accept and acknowledge the disclaimers presented: fVj r =cni,= t-i icir, DVA IV 19N A -I.- . 82018 Zodiac Pool Systerrv; LLC. Ail rights reserved. Rev 8 -