Loading...
HomeMy WebLinkAboutG STAIR 1TI RADCO, LLP 3220 E.59TH STREET LONG BEACH, CA 90805 Tel (562) 272-7231 Fax (562) 529-7513 www.RADCOinc.com March 23, 2018 Mr. Marty Johnson Style Crest Inc. 600 Hagerty Drive Fremont, OH 43420 RE: Review ATI test report on fiberglass coated plywood steps for compliance with the most recent code versions Dear Mr. Johnson: W e have received the test report you submitted from Architectural Testing (ATI), York, PA. The details are as follows: Report number: 01-37911.04, dated 11/7/03 Title: Step Performance Test Report Products covered:4-Tread, Dura-Grip II, Step Unit [A five riser, four tread step fabricated with pressure treated lumber and fiberglass]. At your request, we have evaluated the test report against the building codes outlined below. CODE 2015 International Building Code (IBC) Stairway Dimension Requirem ent Tested Value (2)Compliance W idth (1)36" minim um 38"Pass (1) Riser H eight 7" maxim um, 4" m inim um 7"Pass Tread Depth 11" minim um 11-1/2"Pass Tread Leading Edge Radius 9/16" maxim um Less than 1/2"Pass CODE 2015 International Residential Code (IRC) Stairway Dimension Requirem ent Tested Value (2)Compliance W idth 36" minim um 38"Pass Riser H eight 7-3/4" maxim um 7"Pass Tread Depth 10" minim um 11-1/2"Pass Tread Leading Edge Radius 9/16" maxim um Less than 1/2"Pass Mr. Marty Johnson March 23, 2018 Style Crest Inc.Page 2 CODE 2017 Florida Building Code (FBC) Stairway Dimension Requirement Tested Value (2)Compliance W idth 36" minim um 38"Pass (1) Riser Height 7" maxim um, 4" m inim um 7"Pass Tread Depth 11" minim um 11-1/2"Pass Tread Leading Edge Radius 9/16" maxim um Less than 1/2"Pass Notes: (1) 44" minimum or 36" if serving an occupant load less than 50. (2) The tested values have been taken from the referenced ATI test report, RADCO has not independently verified any of the actual dimensions, and is not responsible for the accuracy of these dimensions. CONCLUSION: There have either been no changes in the dimensional requirements in the IBC, IRC and the FBC or, as in the case of the Tread Leading Edge Radius, the requirements have been altered minimally, when compared to the requirements listed in the referenced ATI test report number 01-37911.04, dated 11/7/03. The product is therefore in compliance with the dimensional requirements of the editions of the IBC, IRC and the FBC referenced above for the four (4) dimensions shown in the tables. st that this proposal has been responsive to your objectives. Please do not hesitate to call if you have any questions. As always, we look forward to working with Style Crest and to starting this program in the near future. This proposal is valid for 90 days. Sincerely, R A D C O Fernando Ardila, Director Testing Laboratories & Materials Evaluation R:\Test Projects\Stylecrest or RMC\C4160A\style crest code verification5.wpd 1-9-18K.PAINTERBnufacturingžÁMa1(ASTP_RL ASSYM.JOHNSONS.APPLEBYBILL OF MATERIALITEMPART NUMBERQTYDESCRIPTIONSTEP & RAIL ASSEMBLY CONFIGURATIONSTEP/RAIL ASSEMBLYCONFIGURATION1320'-7"3'-2"2'-11"0'-378"0'-1178"3'-212"3'-0"0'-10"2'-10"1-9-181-9-18