HomeMy WebLinkAboutBuilding Plans (2)INDUSTRIES 1379 SW BILTMORE STREET, POST ST LUCIE, FLORIDA, 34983 CGC 1507642 v w 03 0 a PROJECT NAME: PROPOSED KING RESIDENCE PROJECT ADDRESS 6800 PEACOCK ROAD, PORT ST LUCIE, FLORIDA 34987 SHEET TITLE : FLOOR PLAN DATE: 08-02-2021 SCALE: AS NOTED GARAGE SIDE : RIGHT EXPOSURE: 160-C MODEL- CUSTOM JOB NUMBER: 2020-01 ENGINEER PAUL WELCH INC. MECHANICAL o ELECTRICAL CIVIL ENGINEERING 1984 SW BILTMORE ST., SUITE # 114 PORT SAINT LUCIE, FL 34984 PHONE: (772) 785-9888 EMAIL: PWELCHINC@,AOL.COM PAUL WELCH P.E. FLORIDA REGISTRATION NO. 299,45 i FIREPLACE SPECIFICATIONS �,-6GC� �( PLAN INFORMATION A SINGLE FAMILY RESIDENCE MODEL CUSTOM GARAGE SIDE RIGHT ELECTRICAL SERVICE UNDER GROUND EXPOSURE 160 C PLAN DIMENSIONS 95'--4"X W--4" 1 AREA TABULATIONS LIVING AREA 2902 SQUARE FEET 2 CAR GARAGE 688 SQUARE FEET COVERED ENTRY 466 SQUARE FEET BACK PORCH 320 SQUARE FEET TOTAL FOOTPRINT 4376 SQUARE FEET LIVING AREA VOLUME 26496.0 SQ. FT. ***ANY CHANGES OR MODIFICATIONS MUST *** BE AUTHORIZED THROUGH THE CONTRACTOR, NO CHANGES TO BE MADE ON SITE WITHOUT CONSENT OF K & S INDUSTRIES. w w d:�i i PRE-ENGINEERED ROOF TRUSSES @ 24" O.C. COVERED BY 19/32" 4 PLY CDX PLYWOOD (SEE NAILING DETAIL) HETA 20 HURRICANE ANCHORS EMBEDDED 4" INTO BEAM FOR TRUSSES (PER CONN. SCHEDULE) 5V CRIMP METAL ROOF OVER PEEL & STICK CONT. GALV. MTL DRIP OVER (PT) 1 X 2 3/4" X 5-12" HARDIE BOARD FASCIA 2" X 4" SUB -FASCIA 2411 NON -VENTED OH STUCCO SOFFIT (SEE DETAIL) TEXTURED STUCCO FINISH & STUCCO LAP FINISH, PER PLAN VERTICAL REBAR TIED TO DOWEL & RUNNING INTO BEAM BLOCK IN 3000 PSI CONC. VERTICAL DOWELS - w/ 30" LAP SPLICE FROM FOOTER CSEE FOUNDATION PLAN FOR SIZE & SPACING J NO SCALE (LEVEL RETURN VENTED STUCCO SOFFIT) (PLUMB CUT FASCIA) * NOTE PROVIDE SCREENED VENTS AT GARAGE, COVERED ENTRY, COVERED PORCHES. 2" X 4" SUPPORT (VERT.) @ 8'-0" O.C. MAX. 2" X 4" CONTINUOUS @ ALL LEVEL RETURNS. CONT. GALV. MTL DRIP OVER (PT) 1 X 2 3/4" X 5-12" HARDIE BOARD FASCIA 2" X 4" SUB -FASCIA STUCCO OVER WIRE LATH w/ llga. 2" NAILS WITH 3/8" HEAD DIA. AT 6" O.C. OVER 3/8" RIB LATH @ 6" O.C. WITH (2 LAYERSOF 15 # FELT OVER EACH FRAMING MEMBER) 6" X 22-1/2" VENTS AT 6'-0" O.C. ACTUAL DESIGN PRESSURES FOR ALL EXTERIOR WINDOWS, DOORS, GARAGE DOORS AND SIMILAR ENVELOPE ELEMENTS OPENING MARK DESCRIPTION OPENING AREA IN SQUARE FEET WALL ZONE POSITIVE NEGATIVE B (2) SH-24 16.1 END ZONE + 33.5 PSF - 44.8 PSF C (2) SH-25 16.1 INTERIOR ZONE + 33.5 PSF - 44.8 PSF D (2) SH-25 16.1 INTERIOR ZONE + 33.5 PSF - 44.8 PSF E (2) SH-25 16.1 INTERIOR ZONE + 33.5 PSF - 36.3 PSF F 3068 ENTRY DOOR 20.0 INTERIOR ZONE + 33.4 PSF - 36.2 PSF G (2) SH-25 16.1 INTERIOR ZONE + 33.5 PSF - 44.8 PSF H SH-H35 11.6 END ZONE + 33.6 PSF - 44.9 PSF EXPOSURE 160-C DESIGN PRESSURES PER ASCE 7-10 ACTUAL DESIGN PRESSURES FOR ALL EXTERIOR WINDOWS DOORS GARAGE DOORS AND SIMILAR ENVELOPE ELEMENTS OPENING MARK DESCRIPTION OPENING AREA 114 SQUARE FEET WALL ZONE POSITIVE NEGATIVE K (2) SH-25 16.1 END ZONE + 33.5 PSF - 44.8 PSF L (2) SH-25 16.1 INTERIOR ZONE + 33.5 PSF - 36.3 PSF M (2) 3068 PATIO DOORS 20.0 INTERIOR ZONE + 33.4 PSF - 36.2 PSF N (2) SH-25 16.1 INTERIOR ZONE + 33.5 PSF - 36.3 PSF 0 SH-33 14.1 INTERIOR ZONE + 33.6 PSF - 36.4 PSF EXPOSURE 160-C DESIGN PRESSURES PER ASCE 7-10 Mi go 31sh K11491141 12 5 ICYNENNE (R-22) SPRAY FOAM INSULATION 1/2" DRYWALL @ CEILING (TYPICAL) 8" X 8" X 16" BEAM BLK. W/ (1) # 5 BAR IN 3000 PSI CONCRETE FILLED CELL. (2 ROWS) 8" PRECAST LINTELS W/ (1) # 5 BAR FOR ALL DOOR AND WINDOVi,' OPENINGS & FILLED 1N/ 3000 P%c' CONCRETE 1"X 2" P.T. FURRING STRIPS o @ 16" O.C. ON TOP OF 3/4" 00 RIGID FOIL FACE INSULATION 1/2" DRYWALL (TYPICAL) 8" CONCRETE BLOCKS WOOD BASE BOARDS CONCRETE SLAB (SEE FOUNDATION PLAN) �i BEARING 8'-0" 0_�,I■I■I■�■I■�■I■I■I■I■I��■I■I■I■I■I■I■I■I■I■I■I■I■I■I■I■I■I■I�%�I�I■I■I■I�I■I■I■I■I■I■I■��I■I■I■I■I■I■I�I■I■I■I■I■I■I■I■I■I■I■�,�■I■'■I■I■I■I■I■I■�■'�1�\, BEARING 81 ji FINISHED • ' 1 i 1111111111 111111 un, I111111111 1111111111 FINISHED • • 1 1 ;� \% muuuu�i,_ _,� nunnm INDUSTRIES 0 1379 SW BILTMORE STREET, PORT ST LUCIE, FLORIDA, 34983 CGC 1507642 a DATE: 08-02-2021 SCALE: AS NOTED GARAGE SIDE: RIGHT EXPOSURE : 160-C MODEL: CUSTOM JOB NUMBER: 2020-01 ENGINEER PAUL WELCH INC. MECHANICAL o ELECTRICAL CIVIL ENGINEERING 1984 SW BILTMORE ST., SUITE # 114 PORT SAINT LUCIE, FL 34984 PHONE: (772) 785--9888 EMAIL: PWELCHINC@10L.COM PAUL WELCH P. E. FLORIDA REGISTRATION NO.29945 AUG 0 2 2021 I W w I m m QL SCALE: 1/4" = V-0" LAP -STUCCO TRIM RETURN ACTUAL DESIGN PRESSURES FOR ALL EXTERIOR WINDOWS, DOORS, GARAGE DOORS AND SIMILAR ENVELOPE ELEMENTS OPENING MARK DESCRIPTION OPENING AREA IN SQUARE FEET WALL ZONE ' POSITIVE NEGATIVE I FIXED GLASS 5.0 INTERIOR ZONE + 33.6 PSF - 36.4 PSF J SH-H32 4.7 INTERIOR ZONE + 33.6 PSF - 36.4 PSF EXPOSURE 160-C DESIGN PRESSURES PER ASCE 7-10 12" X 12" CMU COLUMN PER DETAIL FINISHED FLOOR 0'-0" INDUS �R/ES 1379 SW EILTMORE STREET, PORT ST LUCIE, FLORIDA, 34983 CGC 150764 ACTUAL DESIGN PRESSURES FOR ALL EXTERIOR WINDOWS DOORS GARAGE DOORS AND SIMILAR ENVELOPE ELEMENTS OPENING MARK DESCRIPTION OPENING AREA IN SQUARE FEET WALL ZONE POSITIVE NEGATIVE A 16070 OHGD 112.0 END ZONE + 22.3 PSF - 29.0 PSF EXPOSURE 160-C DESIGN PRESSURES PER ASCE 7-10 BEARING HT 8'-0" 12" X 12" CMU COLUMN PER DETAIL FINISHED FLOOR 0'4' _ GARAGE CALCULATE ATTIC VENTILATION CEILING = 688 SQUARE FEET 688 / 150 = 4.58 REQUIRED VENTILATION 84-7" LINEAR FEET OF 6" X 22-1/2" @ 72" O.C. = 13.11 SQ. FT. / 2 = 6.55 SQUARE FEET AVAILABLE FOR CROSS VENTILATION. 6.55 SQUARE FEET > 4.58 SQUARE FEET: SOFFIT VENTILATION OK PROVIDE 7" X 24" VENTS @ 72" O.C. NOTE: OVER ALL VENT SIZE IS 24" X 7" SCREENED AREA = 22-1/2" X 6" FRONT COVERED PORCH CALCULATEATTIC VENTILATION CEILING = 292.0 SQUARE FEET 292 / 150 = 1.95 REQUIRED VENTILATION 63'-4" LINEAR FEET OF 6" X 22-1/2" @ 72" O.C. = 9.81 SQ. FT. 12 = 4.90 SQUARE FEET AVAILABLE FOR CROSS VENTILATION. 4.90 SQUARE FEET > 1.95 SQUARE FEET: SOFFIT VENTILATION OK PROVIDE 7" X 24" VENTS @ 72" 0. C. NOTE: OVER ALL VENT SIZE IS 24" X 7" SCREENED AREA = 22-1/2" X 6" RAW I N G BEAR FEET LEFT SIDE ELEVATION SCALE: 1/4" = l'-0" El W M3 0 a PROJECT NAME: ■ PROPOSED KING RESIDENCE i ■ PROJECT ADDRESS : 6800 PEACOCK ROAD, PORT ST LUCIE, FLORIDA 34987 ■ SHEET TITLE: ® RIGHT ANP LEFT ELEVATIONS, ROOF PLAN DATE: 08-02-2021 SCALE : AS NOTED GARAGE SIDE: RIGHT EXPOSURE: 160-C MODEL: CUSTOM JOB NUMBER: 2020-01 ROOFING ATTACHMENT NOTES PANEL FASTENER: #9 - 15 X 1 ''/2 ' WOODGRIP WITH SEALING WASHER IN THE RIB OF THE PANEL, '/4" MINIMUM PENETRATION THROUGH THE PLYWOOD. ALL FASTENERS TO BE CORROSION RESISTANT. FASTENERS SHALL BE INSTALLED AT 12" PARALLEL TO ROOF SLOPE AND 12" O.C. PERPENDICULAR TO ROOF SLOPE. ROOFING ATTACHMENT nts... PER FL# 11651.1 METAL ROOF PANELS SHALL BE SECURED TO THE SUPPORTS IN ACCORDANCE WITH THE APPROVED MANUFACTURER'S FASTENERS. METAL PANELS SHALL BE ATTACHED PER MANUFACTURER'S SPECIFICATIONS AND DETAIL THIS SHEET. UNDERLAYMENT SHALL BE INSTALLED AS PER MANUFACTURER'S INSTALLATION GUIDELINES UNDERLAYMENT SHALL BE APPROVED 30# ROOFING FELT. UNDERLAYMENT APPLICATION. UNDERLAYMENT SHALL BE ONE LAYER APPLIED IN THE FOLLOWING MANNER. UNDERLAYMENT SHALL BE APPLIED PARALLEL TO AND STARTING FROM THE EAVE AND LAPPED 2 INCHES (51 MM), FASTENED SUFFICIENTLY TO HOLD IN PLACE. DISTORTIONS IN THE UNDERLAYMENT SHALL NOT INTERFERE WITH ROOF PANNEL INSTALLATION. FLASHING SHALL BE INSTALLED IN SUCH A MANNER SO AS TO PREVENT MOISTURE ENTERING THE WALL AND ROOF THROUGH JOINTS IN COPINGS, THROUGH MOISTURE -PERMEABLE MATERIALS AND AT INTERSECTIONS WITH PARAPET WALLS AND OTHER PENETRATIONS THROUGH THE ROOF PLANE. ALL FLASHING SHALL BE IN ACCORDANCE WITH FLORIDA BUILDING CODE FLASHING SHALL BE INSTALLED AT WALL AND ROOF INTERSECTIONS, AT GUTTERS, WHEREVER THERE IS A CHANGE IN ROOF SLOPE OR DIRECTION AND AROUND ROOF OPENINGS. WHERE FLASHING IS OF METAL, THE METAL SHALL BE CORROSION RESISTANT WITH A THICKNESS NOT LESS THAN PROVIDED IN FBC TABLE 1503.2. THIS REQUIREMENT DOES NOT APPLY TO HIP AND RIDGE JUNCTIONS. ALL ROOFING INSTALLATIONS SHALL BE IN ACCORANNCE WITH FBC 2017. LAP -STUCCO TRIM RETURN ENGINEER PAUL WELCH INC. MECHANICAL o ELECTRICAL CIVIL ENGINEERING 1984 SW BILTMORE ST., SUITE, # 114 PORT SAINT LUCIE, FL 34�84 PHONE : (772) 785-98813 EMAIL: PWELCHINC@AOL.C:OM PAUL WELCH P.E. FLORIDA REGISTRATION NO. 29945 FINISHED FLOOR 0'-0" W W I m 103 Iml A110 - ' --- FLOOD LIGHT PREWIRE FLOOD LIGHT ■ ■ — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — ■ ■ i / I I FLOOD LIGHT PREWIRE CL FAN ONLY PREWIRE FAN ONLY PREWIREdb \ I v \ FLOOD LIGHT PREWIRE WP/GFI : - \ AT SOFFIT WP/GFI ZQ AT SOFFIT ELECTRICAL PLAN - SCALE: 1/4" = 1'-0" TV & PHONE OUTLET LOCATIONS BY BUILDER �SD =SMOKE DETECTOR CO =CARBON MONOXIDE DETECTOR & ��0 INDUSTRIES 1379 SW BILTMORE STREET, PORT ST LUCIE, FLORIDA, 349$3 CGC 1507642 WP/GFI AT SOFFIT FLOOD LIGHT PREWIRE / PROJECT NAME: A/C COND. # 1 A/C COND. # 2 �. w FLOOD LIGHT PREWIRE J \ a QD WP/GFI DQ AT SOFFIT 1 I I I I I I FLOODLIGHT PREWIRE / WP/GFI DQ AT SOFFIT ELECTRICAL SYMBOL LIEGEND/ SWITCH $ THERMOSTAT TO GFIOUTLE; 3-WAY SWITCH $3 SD/CO DETECTOR © � ��; FL 4-WAY SWITCH $4 EXHAUST FAN UORESCENT LIGHT DIMMER SWITCH $o DOOR CHIMES GARAGE DOOR OPENER PUSH BUTTON [0 ALARM PAD �o WP-GFI OUTLET DPi) � SERVICE PANEL/ N® CEILING FAN 110V OUTLET (p SERVICEMlfTER 220V OUTLET 9 LIGH FIXTURE / 1 �J 4-PLEX OUTLET WALL MOUNTED / O SWITCHED OUTL� LIGHT FIXTURE LIGHT FIXTURE �PJ CEILING FAN w/LIGHT SPECIAL RURPOSE ® w/PULL SWITCH J NOTION BOX RECESSED LIGHT A/C DISCONNECT =' VAPOR PROOF 0 PHONE OUTLET RECESSED LIGHT TV OUTLET FLOOD LIGHT PENDANT PREWIRE 0 FLOOR OUTLET c E. FAN LIGHT SC0NCE PREWIRE �7_) NOTE TO BUILDER: ALL BEDROOM OUTLETS MUST BE ARC FAULT PROTECTION OUTLETS PER NEC 210-12(b) SMOKE DETECTORS SHALL BE WIRED TO COMPLY WITH NFPA 72 200 M 2 MBR UG SERVICE BY FPL (3)-#3/0THW IN2"C "EP"' "EP" 20/240V 120/240V I I 100A 100A MLO MLO I— L (3) 3/0, # 4, 2" C (3) 3/0, # 4, 2" C # 4 CU GROUND TIED TO BUILDING STEEL, CWP AND DRIVEN GROUND ROUND ELECTRICAL RISER NOTE: USE ALL COPPER WIRE NO SCALE ■ PROPOSED KING RESIDENCE ■ PROJECT ADDRESS : 6800 PEACOCK ROAD, PORT ST LUCIE, FLORIDA 34987 ■ SHEET TITLE : ELECTRICAL PLAN, ELECTRICAL RISERS, ELECTRICAL NOTES, CALCS. DATE: 08-06-2021 SCALE: AS NOTED GARAGE>IDE : RIGHT EXPOSURE: 160-C MODEL: CUSTOM JOB NUMBER: 2020-01 ELECTRICAL NOTES 1) ALL ELECTRICAL WORK SHAL BE IN ACCORDANCE WITH THE NEC (NFPA 70) 2014 EDITION. 2) A MINIMUM OF 75% OF THE LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE HIGH-EFFACY LAMPS OR A MINIMUM OF 75% OF THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL CONTAIN ONLY HIGH-EFFACY LAMPS. (LOW VOLTAGE LIGHTING SHALL NOT BE REQUIRED TO BE HIGH-EFFACY LAMPS) 3) RECESSED LIGHTING SHALL BE SEALED TO LIMIT AIR LEAKAGE BETWEEN CONDITIONED AND UNCONDITIONED SPACES. 4)SMOKE DETECTORS TO BE 110V W/ BATTERY BACK UP -ARC FAULT CIRCUIT 5) SMOKE DETECTORS TO BE INTERCONNECTED SO THAT ONE SMOKE DETECTOR ACTIVATES ALL SMOKE DETECTORS IN THE RESIDENCE 6) PROVIDE BRANCH CIRCUIT ARC -FAULT PROTECTION FOR ALL CIRCUITS SERVING: FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS PER FBC AND NEC REQUIREMENTS. 7) PROVIDE GROUND -FAULT CIRCUIT INTERRUPTER PROTECTION FOR ALL 125-VOLT, SINGLE-PHASE 15 AND 20 AMP CIRCUITS SREVING: BATHROOMS, GARAGES, KITCHENS, ACCESORY BUILDINGS, OUTDOORS, OR WITHIN 72" OF EDGE OF ANY SINK. 8) CARBON MENOXIDE DETECTORS TO BE INSTALLED WITHIN 10' OF ALL BEDROOMS. 9) EXHAUST FANS TO BE VENTED THRU ROOF OR SOFFIT. 10) PROVIDE TAMPER RESISTANT RECPTICLES PER NEC REQUIREMENTS. FIREPLACE SPECIFICATIONS TOUCHSTONE 50.4 INCH. BLACK FAN FORCED, FIREPLACE. MODEL: 8004 HARDWIRED 120 VOLTS MAXIMUM BTU'S 5118 MAXIMUM WATTAGE 1500 TYPE: WALL MOUNT COLLECTION: SIDELINE SAFETY LISTING: CSA SAFETY LISTING PRIMARY MATERIAL: METAL ASSEMBLED HEIGHT: 20.5 INCHES ASSEMBLED WIDTH : 50.4 INCHES WEIGHT: 59 LBS COLOR / FINISH: BLACK SCREEN TYPE: GLASS MAX SUPPLEMEMENTAL HEATING AREA: 440 SQUARE FEET ENGINEER PAUL WELCH INC. MECHANICAL o ELECTRICAL CIVIL ENGINEERING 1984 SW BILTMORE ST., SUITE # 114 PORT SAINT LUCIE, FL 34984 PHONE: (772) 785-9888 EMAIL: PWELCHINC@AOL.CCM PAUL WELCH P.E. FLORIDA REGISTRATION NO, 29945 SEF 0 9 2021 i W w I M }DECEIVED St. Lucie County Permitting ML '0a" o618