ASCE 7 Components & Cladding Wall Pressure Calculator
Prepared For:
WRIGHTS IMPACT WINDOW & DOOR
7816 S DIXIE HWY
WEST PALM BEACH FL
Project: JOHN FLEMING
Project Address:
9490 S OCEAN DR 610
JENSEN BEACH Florida 11/11/2021
Box for Engineer Seal Only-Original Rqd for Permit & Use
** See below for sealing engineer.
** This document has been signed by one of the following engineers. Refer to name in stamp for applicable engineer.
C/A 9885 | Frank Bennardo PE 0046549 | Richard Neet, PE 86488 | Andrew McCann PE 92471
The following has been considered in determining allowable stress design (ASD) wall opening pressures for the above-referenced
location.
ASCE: ASCE 7-16 (2020 FBC 7th ED, 2018 IBC)
Wind Velocity: 170 MPH
Exposure Category: D
Kd: 0.85
Kzt: 1
Minimum Building Dimension: 50FT
Mean Roof Height: 120FT
Lowest Installation Elevation: 0FT
ROOF SLOPE: FLAT (<10°)
Number Of Openings: 3
Shutter: NO
Mark: 1
Height Of Opening: 39 IN
Width Of Opening: 37 IN
Zone: 4
Mark: 2
Height Of Opening: 51 IN
Width Of Opening: 111 IN
Zone: 4
Mark: 3
Height Of Opening: 39 IN
Width Of Opening: 74 IN
Zone: 4
Based on the above, the following ASD design pressures apply for the opening
marks which shall correspond with contractor-supplied building layout:
a: 5 FT
Mark: 1
Wall Positive Pressure: 60.3PSF
Wall Negative Pressure: -60.3PSF
Mark: 2
Wall Positive Pressure: 56.8PSF
Wall Negative Pressure: -58.1PSF
Mark: 3
Wall Positive Pressure: 60.3PSF
401 West Atlantic Avenue, R10 Unit #219, Delray Beach, FL 33444
(954) 354-0660 | (866) 396-9999 Team@EngineeringExpress.com | EngineeringExpress.com
95919 | 44511-5011111111 | Page 2/2
Wall Negative Pressure: -60.4PSF
Design pressure results are in accordance with the Building & ASCE 7 codes listed above for an ENCLOSED structure only
(Gcpi=+-0.18). Results are based on contractor-supplied data and are not field verified by this office. Input shall be verified by others prior
to permit & use. Selection of all components & their respective approvals shall be by others and are to be within the ASD design pressure
limitations stated herein. Results only valid with original or verifiable digital seal by a licensed PE of this firm. For more information on any
of the terms listed herein, or to use a design tool to evaluate your openings, visit EngineeringExpress.com/Wind.
Powered by TCPDF (www.tcpdf.org)
401 West Atlantic Avenue, R10 Unit #219, Delray Beach, FL 33444
(954) 354-0660 | (866) 396-9999 Team@EngineeringExpress.com | EngineeringExpress.com