HomeMy WebLinkAboutConstruction PlansDESIGN CRITERIA: APPLICABLE CODES REGULATIONS & STANDARDS 1. THE 2020 FLORIDA BUILDING CODE, SPECIFICALLY CHAPTER 16 STRUCTURAL DESIGN, CHAPTER 20 ALUMINUM & CH. 23 WOOD. 2. AA'ASM 35 & SPECIFICATIONS FOR ALUMINUM STRUCTURES, PART 1-A OF THE ALUMINUM DESIGN MANUAL PREPARED BY THE ALUMINUM ASSOCIATION, INC. WASHINGTON D.C. 2005 ED. 3. ASCE 7-16 & SE17 4. NDS NATIONAL DESIGN SPECIFICATION FOR WOOD. 5. ACI318 CONCRETE REFERENCE MANUAL. WIND LOADS 1. BUILDING OCCUPANCY CATEGORY, PARAGRAPH 1604.5 & TABLE 1604.5: RISK CATEGORY 1. 2. BASIC WIND SPEED, TABLE 1609C, STATE OF FLORIDA DEBRIS REGION & BASIC WIND SPEED, PARAGRAPH 1609.3.1 & TABLE 1609.3.1 EQUIVALENT BASIC WIND SPEED: 150 MPH EXPOSURE CATEGORY, PARAGRAPH 1609.4.3: B 3. WIND LOADS PER FBC TABLE 2002.4 (MWFRS) VULT = 150 MPH & EXPOSURE = B FOR 20 X 20 X 0.013" MESH SCREEN HORIZONTAL PRESSURES ON WINDWARD SURFACES = 31 PSF HORIZONTAL PRESSURES ON LEEWARD SURFACES = 32 PSF VERTICAL PRESSURES ON SCREEN SURFACES = 9 PSF VERTICAL PRESSURES ON SOLID SURFACES = 25 PSF FOR 18 X 14 X 0.013" MESH SCREEN, APPLIED FACTOR = •88 FOR ALLOWABLE STRESS DESIGN, APPLIED FACTOR = •6 FOUNDATION DESIGN FOOTING SIZE EXISTING CONCRETE SLAB. NO ADDITIONAL FOOTING OR FOUNDATION SYSTEM IS REQUIRED BY THE PROPOSED CONSTRUCTION IF A MINIMUM 4" CONCRETE SLAB IS PROVIDED IN SOUND CONDITION, FREE FROM STRUCTURAL CRACKING, SPALLING & OTHER DETERIORATION. EXISTING FOUNDATION/FOOTING UNDER CONCRETE SLAB MINIMUM 8"x8" W/ (1) #5 BAR TO BE VERIFIED BY CONTRACTOR. SEE TYPICAL FOOTING DETAILS FOR NEW FOOTING DESIGN MINIMUM REQUIREMENTS. MISCELLANEOUS 1. SCREENED ENCLOSURES CONTAINING SWIMMING POOLS SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF FBC R4501.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS. 2. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME. IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPARATE 4TH WALL SUPPORT SYSTEM IS SO TO BE ENGINEERED SO THAT NO ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. FASTENER SPECIFICATIONS 1. FASTENERS ARE REQUIRED TO BE SAE GRADE 2 OR BETTER ZINC PLATED. (CONCRETE ANCHORS ARE TO BE TAPCONS OR BETTER, INSTALLED TO MFG. SPECIFICATIONS) 2. IT IS THE OWNERS RESPONSIBILITY TO MAINTAIN THE SCREENS, FASTENERS AND SCREENS TO MANUFACTURING SPECIFICATIONS. 3. WHERE WOOD DECK IS PRESENT USE 1 /4" X 3-1/2" GALV. LAG SCREWS IN LIEU OF MASONRY ANCHORS. UNLESS OTHERWISE SPECIFIED. 4. 1'X2" NON STRUCTURAL MEMBERS ATTACHED TO HOST A. FOR MASONRY/CONCRETE APPLICATION USE GALVANIZED 1 /4" X 2-3/4" TAPCONS OR EQUAL AT 24" O.C. AND 6" FROM ENDS B. FOR WOOD APPLICATION USE # 14 X 2-3/4" WOOD SCREW AT 24" O.C. AND 6" FROM ENDS. C. FOR ALUMINUM APPLICATION USE #10 X 1-1 /2" SMS OR TEK SCREW AT 24" O.C. AND 6" FROM ENDS D. WHERE 1"X2" INSTALLED THROUGHOUT AN "OPEN VIEW" SPACING SHALL BE REDUCED TO 18" O.C. AND 6" FROM ENDS RESPONSIBILITIES 1. ALL SITE WORK SHALL BE PERFORMED BY A LICENSED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDANANCES, AND THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES. 2. FOR FASTENERS WHICH ARE NOT VISIBLE AFTER INSTALLATION, THE CONTRACTOR SHALL VERIFY AND ENSURE INSTALLATION HAS BEEN ACCOMPLISHED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS AND IN ACCORDANCE WITH THE ATTACHED DETAILS. 3. FOR "PICTURE WINDOW" MODIFICATION TO EXISTING SCREEN ENCLOSURES, ALL OTHER "EXISTING SCREEN ENCLOSURE" FEATURES ARE TO MEET THE TYPICAL DETAILS AS PROVIDED IN THESE DETAILS. CONTRACTOR IS TO VERIFY & ASSURE EXISTING SCREEN ENCLOSURE IS STRUCTURALLY SOUND. 4. CONTRACTOR TO PROVIDE NOA'S & INSTALL ALL MATERIALS AS PER MANUFACTURER'S SPECIFICATIONS. 5. INTEGRITY OF EXISTING/ HOST STRUCTURE SHALL NOT BE COMPROMISED WITH THE ATTACHMENT OF THE PROPOSED STRUCTURE. SHEET NO. DRAWING INDEX S/01 GENERAL NOTES S/02 PLAN/ ELEVATIONS S/03 DETAILS PROPOSED SCREEN ROOM SEE FOUNDATION DESIGN SHEET-01 ALUMINUM MEMBERS DIMENSIONS HOLLOW SECTIONS 2 x 2: 2x2`4.044" 2 x 3: 25(3"x0.050" 2 x 4: 2'k4"4.050" 2 x 5: n5k0.050" OPEN BACK SECTIONS 1 x 2: 1 "x2"4.044" 1 x 3: 1 "x3"4.045" SNAP SECTIONS 2 x 2 SNAP: 2x2"x0.045" 2 x 3 SNAP: Zlx3"x0.050" 2 x 4 SNAP: 2'k4"x0.045" SELF MATING (SMB) 2 x 4 SMB: 240.044'k0.100" 2 x 5 SMB: 2"x5"x0.050"x0.100" 2 x 7 SMB: n7'k0.0572X EMD FOR 2 x 8 SMB: 2"x8' . . 9„ COMIPLlANCE 2 x 9 SMB: 2'k9' 2 x 10 SMB: W"t " COUNTY BOLO DETAIL A IZED a o O p: C° .Z_ C-) .0 . ' •........•' w r 0 (V � N -I 1" 7'-8 4 16"X.024" KP TYP, ALUMINUM SPECIFICATIONS 1. ALUMINUM EXTRUSIONS SHALL BE 6005 T5 ALLOY UNLESS OTHERWISE NOTED. 2. ALL SELF MATING BEAM SECTIONS ARE TO BE STITCHED WITH #12 SCREWS 6" FROM ENDS & 24" CENTER TO CENTER. #10 SCREW 6" FROM ENDS & 12" CENTER TO CENETER. 3. ROOF BRACING SHALL BE A MINIMUM 2X2"X.050". 4. THE MINIMUM NORMAL THICKNESS OF PROTECTOR PANELS (KICKPLATES) SHALL BE AN INDUSTRY STANDARD OF 0.024 INCHES. 5. VINYL AND ACRYLIC PANELS SHALL BE REMOVED WHEN WIND SPEEDS EXCEED 75 MPH PER FBC. 6. SCREEN MATERIAL SHALL BE 18/14 SCREEN UNLESS APPROVED BY FLORIDA ENGINEERING LLC. 7. 1 "X2" & 1 "X3" NON STRUCTURAL MEMBERS MAY BE USED INTERCHANGEABLY. 8. DOOR LOCATION MAY BE RELOCATED BY CONTRACTOR IN THE FIELD. 9.NOTE: 36" (MAX.) O/H AT FRONT, 25% OF LAST PANEL WIDTH ALONG SIDES, TYP. HOST 24" O/H (FASCIA MOUNT) 'I I I 3" X .03I2" X 11-13 w COMPOSITE PANELS of 3003-H154 Lu I I 1/4"-1' SL PE (MIN.) N (FL.# 7561.1-115) I I I I I I I I I I I I I I I I 2X X.050 EDGE BEAMX2 '-0" ------------------------------�� - --------------------------- 29'-0" ?YAY nSn FnrF RFAMX?q'-n" m N d N CV [V X N r-11 , _ X N 2X2 TYP. � 1X2 TYP. 7'-3" 71-31�'1 1X2 2X2 DJ 0 00 N N N X cI 2X4 0 0o 1X2 1" 7'-8 4 \\\\OIIlllllli;������// / Z co � 0O =DLU � Lu 'Z ;v v> z Q ////1111111111111\\\\\\ U v- CV J C) Lo J � � I— co zzo 0 p U W O co J CA n ~W ~ Ch C= cm w Q -gy m 0 Q = L.L 0 O J 0- LL w rn W.. U \0 N 00 I- C) cQ W U Q U N co N_ N O z W 0 Z 0 0 J Z w O LL W E W U Y�� � Z O O J W U Q Z)00a Y F W � IL o w 0 1 a DESIGN DATE: 10/14/2021 REVISION 1: DATE REVISION 2: DATE SHEET: O DRAWN BY: ST SCALE: NTS 4 \\�1111111111,,111I//////// a�>^ '�i J'vz o N "NOTE: �� o ALTERNATELY SEE �� 4.Q - N "ROOF PANEL TO BEAM" ROOF PANELS ATTACH TO DETAIL THIS PAGE C .'!�j �y LL Q�V% w ROOF PER PLAN EDGE BEAM PER PLAN _ co O O 0_ HOST 6" FROM ENDS (SEE NOTE) ' W O {c (1" PENETRATION (MIN.)) - y z U) ALTERNATES FOR COL TO 2°X2°AT HEADER: CARRIER BEAM �� \� / �� ! . '•"•"' U` LLj 1-DETAIL"C"SHT3 SEE ROOF PANEL i 2- 4 # 10 X 3° SMS THROUGH MEMBER ABOVE TO BEAM ONNECTION /////11111 THIS PAGE INTO COL SCREW BOSS 3- NOTCH COL. TO RECEIVE ADJOINING BEARING WALL BEAM FASTEN W/ COL. PER PLAN (2)11W THRU-BOLT cq co j� 1" X 2" FASTEN TO � ) 1"X2" FASTEN TO ADJOINING WALL J r CHAIR RAIL PER PLAN ADJOINING WALL W/#12 X 1-1IT SMS (Y) W/#12 X 1-1/2" @ 18" O.C. r n co~ Of 1/4"X2-3/4"TAPCONS SMS @ 18" O.C. `,J Z Q U OR EQUAL AT 24" O.C. Z ::) 0 (i V AND 6" FROM ENDS KICK PLATE IS INDICATED WHERE FASTEN W/ #10 X 9/1W SMS WHERE SMB USED FOR COL. ATTACH PER W J O cc)8" O/C AT PERIMETER DETAIL "B" , , , J (3) � EXISTING CONCRETE TYPICAL SIDE WALL 1/4" TAPCON (RED HEAD MFG. OR EQUAL) 6" FROM ENDS 24" O.C. COLUMN 1-1/2" PENETRATION INTO UNDERLYING FOOTING SCREEN ROOM END WALL SCALE: NTS #14 X 4" TEK SCREW W/ 1-1/2" NEO-PRENE WASHER @ 12" O.C. (4) PER PANEL 3" COMPOSITE ROOF PANEL BEAM QTY/ SIZE EACH SIDE ANGLE 2x3 (3)/#14TEKS 1x2x1/8'' 2x4 (5)/#14TEKS 2x2x1/8" 2x5 (5)/#14TEKS 2x2x1/9' 2) #12 TEKS EACH CLIP RECEIVER CHANNEL ------- -----------_ --:- =- ------------- - -SUPPORT BEAM �-3'-0" MAX. (CARRIER BEAM CONNECTION SIMILAR) ROOF BEAM TYPICAL RAIL IT 2X2X125" ANGLE 14 TEKS EA. SIDE 2X3X05" (2) #14 TEKS PER SCHEDULE W/(3)# #14 TEKS DETAIL "C" CHAIR RAIL TO POST BEAM TO BEAM CONNECTION W/ (3) #14 TEKS EA. SIDE SCALE: N.T.S. SCALE: N.T.S. ALTERNATELY: FOR COMPOSITE ROOFS 1/4" LAG BOLT W/ 1-1/4"FENDER WASHER @12" O.C. BEARING AND 24" O.C. @\ NON BEARING FOR PAN ROOF (3) EA. #SX1/2" LONG SMS PER 12" PANEL W/ 3/4" ALUMINUM PAN WASHER CAULK ALL EXPOSED SCREW HEAD AND WASHERS OR USE NEOPRENE WASHERS WITH RUBBER GROMMETS ROOF PANEL TO BEAM SCALE: N.T.S. RECEIVING CHANNEL W/ #12SMS @ 10— "O.C. TOPP AN AND BOTTOM -------------- - XISTING ROOF L-1/4"X2-1/2" LAG 3" COMPOSITE @ 12" O.C. ROOF PANEL ROVIDE SHIM IF FASCIA SQUARE CUT ROOF PANEL TO FASCIA SCALE: N.T.S. NOTE: WHERE 2X3 UPRIGHT INSTALLED NO SECONDARY ANGLE REQUIRED USE 3/8" DIA ANCHOR IN LIEU OF 1/4" DIA 1X O.B. SCREEN CHANNEL W/ 1/4" DIA. TAPCONS @24" O.C. 2X2X3 CLIP ANGLE (4) #14 EACH SIDE & (1)1/4"X2" EMBED TAPCON EA. SIDE L2X2X2X1/4 ANGLE CLIP W/ (4) #14 TEKS EACH SIDE OF POST 3/8" DIA.X3" MIN. EMBED TAPCON EACH SIDE 4" CONCRETE SLAB X X /O #5CONT. X UPRIGHT TO THICKENED SLAB EDGE SCALE: N.T.S. 1X_O.B. SCREEN CHANNEL W/ 1/4" DIA. TAPCONS 24" O.C. 2X2X3 CLIP ANGLE (4) #14 EACH SIDE & (1)1/4"X2" EMBED TAPCON EA. SIDE t2X2X2X1/4 ANGLE CLIP W/ (4) #14 TEKS EACH SIDE OF POST 3/8" DIA.X3" MIN. EMBED TAPCON EACH SIDE BRICK PAVERS-1 0 j OR 9"X16" W/ (2) #5 CONT. UPRIGHT TO DECK W/ PAVERS PRESENT SCALE: N.T.S. -