HomeMy WebLinkAboutCONSTRUCTION PLAN & SPECIFICATIONSDESIGN CRITERIA: APPLICABLE CODES, REGULATIONS & STANDARDS 1. THE 2020 FLORIDA BUILDING CODE, SPECIFICALLY CHAPTER 16 STRUCTURAL DESIGN, CHAPTER 20 ALUMINUM & CH. 23 WOOD. 2. AA ASM 35 & SPECIFICATIONS FOR ALUMINUM STRUCTURES, PART 1-A OF THE ALUMINUM DESIGN MANUAL PREPARED BY THE ALUMINUM ASSOCIATION, INC. WASHINGTON D.C. 2005 ED. 3. ASCE 7-16 & SE17 4. NDS NATIONAL DESIGN SPECIFICATION FOR WOOD. 5. ACI318 CONCRETE REFERENCE MANUAL. WIND LOADS 1. BUILDING OCCUPANCY CATEGORY, PARAGRAPH 1604.5 & TABLE 1604.5: RISK CATEGORY 1. 2. BASIC WIND SPEED, TABLE 1609C, STATE OF FLORIDA DEBRIS REGION & BASIC WIND SPEED, PARAGRAPH-1609.3.1 & TABLE 1609.3.1 EQUIVALENT BASIC WIND SPEED: 150 MPH EXPOSURE CATEGORY, PARAGRAPH 1609.4.3: C 3. WIND LOADS PER FBC TABLE 2002.4 (MWFRS) VULT = 150 MPH & EXPOSURE = C FOR 20 X 20 X 0.013" MESH SCREEN HORIZONTAL PRESSURES ON WINDWARD SURFACES = 43 PSF HORIZONTAL PRESSURES ON LEEWARD SURFACES = 34 PSF VERTICAL PRESSURES ON SCREEN SURFACES = 12 PSF VERTICAL PRESSURES ON SOLID SURFACES = 36 PSF FOR 18 X 14 X 0.013" MESH SCREEN, APPLIED FACTOR = •88 FOR ALLOWABLE STRESS DESIGN, APPLIED FACTOR = •6 FOUNDATION DESIGN I.PROPOSED 8"X8" FOOTER W/ (1) #5 REBAR W/ 4" SLAB 3000 PSI W/ FIBERMESH 2. PROPOSED #4 REBAR X I Z 6' EMBEDMENT INTO EXISTING POOL DECK 24" O.C. TYP. MISCELLANEOUS 1. SCREENED ENCLOSURES CONTAINING SWIMMING POOLS SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF FBC R4501.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS. 2. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME. IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPARATE 4TH WALL SUPPORT SYSTEM IS SO TO BE ENGINEERED SO THAT NO ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. FASTENER SPECIFICATIONS 1. FASTENERS ARE REQUIRED TO BE SAE GRADE 2 OR BETTER ZINC PLATED. (CONCRETE ANCHORS ARE TO BE TAPCONS OR BETTER, INSTALLED TO MFG. SPECIFICATIONS) 2. IT IS THE OWNERS RESPONSIBILITY TO MAINTAIN THE SCREENS, FASTENERS AND SCREENS TO MANUFACTURING SPECIFICATIONS. 3. WHERE WOOD DECK IS PRESENT USE 1 /4" X 3-1/2" GALV. LAG SCREWS IN LIEU OF MASONRY ANCHORS. UNLESS OTHERWISE SPECIFIED. 4. 1' X2' NON STRUCTURAL MEMBERS ATTACHED TO HOST A. FOR MASONRY/CONCRETE APPLICATION USE GALVANIZED 1 /4" X 2-3/4" TAPCONS OR EQUAL AT 24" O.C. AND 6" FROM ENDS B. FOR WOOD APPLICATION USE #14 X 2-3/4" WOOD SCREW AT 24" O.C. AND 6" FROM ENDS. C. FOR ALUMINUM APPLICATION USE #10 X 1-1 /2" SMS OR TEK SCREW AT 24" O.C. AND 6" FROM ENDS D. WHERE 1 "X2" INSTALLED THROUGHOUT AN "OPEN VIEW" SPACING SHALL BE REDUCED TO 18" O.C. AND 6" FROM ENDS RESPONSIBILITIES 1. ALL SITE WORK SHALL BE PERFORMED BY A LICENSED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDANANCES, AND THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES. 2. FOR FASTENERS WHICH ARE NOT VISIBLE AFTER INSTALLATION, THE CONTRACTOR SHALL VERIFY AND ENSURE INSTALLATION HAS BEEN ACCOMPLISHED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS AND IN ACCORDANCE WITH THE ATTACHED DETAILS. 3. FOR "PICTURE WINDOW" MODIFICATION TO EXISTING SCREEN ENCLOSURES, ALL OTHER "EXISTING SCREEN ENCLOSURE" FEATURES ARE TO MEET THE TYPICAL DETAILS AS PROVIDED IN THESE DETAILS. CONTRACTOR IS TO VERIFY & ASSURE EXISTING SCREEN ENCLOSURE IS STRUCTURALLY SOUND. 4. CONTRACTOR TO PROVIDE NOA'S & INSTALL ALL MATERIALS AS PER MANUFACTURER'S SPECIFICATIONS. 5. INTEGRITY OF EXISTING/ HOST STRUCTURE SHALL NOT BE COMPROMISED WITH THE ATTACHMENT OF THE PROPOSED STRUCTURE. %tr_oat® 6 v%M SEC meet a� QeCmgL O Go�pt`I st. SHEET NO. DRAWING INDEX S/01 GENERAL NOTES S/02 PLAN/ ELEVATIONS S/03 FOUNDATION PLAN S/04 DETAILS S/05 DETAILS S/06 DETAILS NEW MANSARD SCREEN ENCLOSURE SEE FOUNDATION PLAN SHEET-03 CONTRACTOR COPY NCE ®pCC a N v o O N LLI cn O J= a Lu = U co w � Q z - C� - : U .z 0 m LU '�. ui LLJ //rlllllllll\ U /0 „o 6 p v> ''> zLLJ JGLE E/S BEAM GLE LEG X2 TO SMB (FOR SCREEN .1 FOR ATTACHMENT) =REEN Z---- IT) _ E o o IMB PER PLAN SLOPED OR FLAT �n o p <� o u Ui oo, TABLE SI ' SMB TO CARRIER SIDE VIEW 1/B"1t7XT'XSURFACELENGTHANGLEE/S SCREWS FASTEN ANGLE LEG TO CARRIER BEAM W/#14X9/16' SMS THROUGH ANGLE LEG INTO BEAM -FASTEN ANGLE LEG TO SMB INSIMILARMANNER-SEETABLESA FOR f0 CARRIER BEAM FASTENER OUANTBY. NLE: NTS FOUNDATION DESIGN 1.PROPOSED 8"X8" FOOTER W/ (1) #5 REBAR W/ 4" SLAB 3000 PSI W/ FIBERMESH 2. PROPOSED #4 REBAR X 12", 6" EMBEDMENT INTO EXISTING POOL DECK 24" O.C. TYP. SPECIFICATIONS THE FOLLOWING SPECIFICATIONS ARE APPLICABLE TO THIS PROJECT: 1. WHERE CONCRETE SPECIFICATIONS ARE REQUIRED, WHETHER IN THE SCREEN ENCLOSURE SCOPE OR NOT, BY ONE OR MORE REGULATORY AGENCY, THE FOLLOWING SPECIFICATIONS ARE APPLICABLE: a. CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING COMPONENTS: i. PORTLAND CEMENT TYPE 1 - ASTM C 150 ii AGGREGATES - LARGE AGGREGATE 3/4 MAX. - ASTM C 33 III. AIR ENTRAINING +/- 1 %- ASTM C 260 iv. WATER REDUCING AGENT - ASTM C 494 v. CLEAN POTABLE WATER vi. OTHER ADMIXTURES NOT PERMITTED b. METAL ACCESSORIES SHALL CONFORM TO: i. REINFORCING BARS - ASTM A615, GRADE 60 ii. WELDED WIRE FABRIC - ASTM A185 c. CONCRETE SLUMP AT DISCHARGE CHUTE NOT LESS THAN 3" OR MORE THAN 5". WATER ADDED AFTER BATCHING IS NOT PERMITTED. d. PREPARE & PLACE CONCRETE PER AMERICAN CONCRETE INSTITUTE MANUAL OF STANDARD PRACTICE, PART 1, 2, & 3 INCLUDING HOT WEATHER RECOMMENDATIONS. e. MOIST CURE OR POLYETHYLENE CURING PERMITTED. f. PRIOR TO PLACING CONCRETE, TREAT THE ENTIRE SUBSURFACE AREA FOR TERMITES IN COMPLIANCE WITH THE FBC. FOR RISK CATEGORY II, III, & IV STRUCTURES ONLY. g. CONCRETE SLAB SHALL BE PLACED OVER A POLYETHYLENE VAPOR BARRIER. (SLAB ONLY) 2. WHEN PAVERS ARE UNDER ALUMINUM MEMBERS, CONTRACTOR SHALL EPDXY TO DECK OR GROUT TO DECK w/3000 PSI GROUT WITH BONDING AGENT 3. WHEN APPLICABLE FOR NEW SLAB ADDITION TO ADJACENT DRILL & EPDXY #4 X 8" REBAR INTO EX. FOUNDATION EMBED 4" MIN W/ NON -SHRINKING SIMPSON EPDXY -TIE (OR EQUAL) 48" O.C. TYP. ALL LOCATIONS 4. WHEN APPLICABLE FOR NEW FOOTER TO EXISTING, DRILL & EPDXY NEW STEEL INTO EX. FOUNDATION WITH EMBED 6" MIN W/ NON -SHRINKING SIMPSON EPDXY -TIE (OR EQUAL) TYP. ALL LOCATIONS 5. WHERE PAVERS ARE UNDER ALUMINUM MEMBERS, CONTRACTOR SHALL EPDXY TO DECK OR GROUT TO DECK w/3000 PSI GROUT WITH BONDING AGENT. 6. MINIMUM CONCRETE STRENGTH 3000 PSI UNLESS OTHERWISE NOTED. MASONRY SPECIFICATIONS 1. CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON TYPE M OR S MORTAR. 2. ALL MORTAR SHALL BE TYPE M OR S. 3. ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE MAXIMUM COARSE AGGREGATE SIZE OF 3/8". 4. PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS 5-0" IN HEIGHT. FOOTING NOTES 1. PROVIDE 1-1/2' COVERAGE TOP, SIDES, BOTTOM AND 1" BETWEEN ADJACENT REBAR LAPS. 2. PROVIDE MIN. 3" COVERAGE OF REBAR FOR ALL CONCRETE IN CONTACT WITH THE EARTH. 3. FOOTING CONCRETE SHALL BE MIN. 3000 PSI AT 28 DAYS 4. FOOTING REINFORCEMENT SHALL BE MIN. GRADE 60 5. PROVIDE POSITIVE DRAINAGE AWAY FROM STRUCTURE TO CITY / CO. REQUIREMENTS 6. PROVIDE 2500 PSF BEARING (TYPICAL) UNDER FOUNDATION 7. SEE GENERAL NOTES ABOVE FOR TYING INTO EXISTING FOUNDATIONS 8. SEE GENERAL NOTES ABOVE FOR ADDITIONAL CONCRETE INFORMATION & SPECS. O SODDED GRADE 8"x8„ 6" EM EXIST NEW 4" SLAB 3000 PSI /� EXISTING POOL DECK W/FIBERMESH , / j " f/\ 45` #4 REBAR X 17' #' EMBEDMENT INTO EXISTING POOL DECK 24"O.C.TYP. (1) #5 BAR v N =�.dj CD0 Z L L d -0:w (D H y z c 111111111111\0\\\ NCRETE LEGEND BATCH INDICATES HOST/ EXIST. NEW FOOTING NEW SLAB AREA iTE: ALL MAY NOT APPLY MONOLITHIC VG N 0 N Lu FOUNDATION PLAN : NTS 1'V' FASTEN TO COL. (INTERNAL) w/(2) # 10xl-1/Z' SMS, FASTEN TO EAVE RAILS ABOVE w/# 10 1-1 /2" SMS 24" O.C. AND 6" WITHIN COL. TABLE "D" BEAM QTY/ SIZE EACH SIDE 2x3 (4)/ #12 2x4 (5)/#12 2x5 (5)/#12 2x6 (6)/#12 2x7 (7)/#12 2x8 (8)/#14 2x9 (9)/#14 2x10 (9)/#14 MAINTAIN MIN, OF 5/8" SEPERATION FROM EDGE OF BEAM SMS O.C. D 0 BEAM PER PLAN o 0 0 (SLOPED OR FLAT) 0 0 MER PLAN NOTCHED TO RECEIVE COLUMN WITHIN SMS, (EACH SIDE) QTY/ SIZE PER TABLE "D" NOTCH PROFILE MAY VARY TO PERMIT CORRECT # SMS COLUMN PER PLAN DETAIL E - UPRIGHT TO BEAM CONNECTION SCALE: NTS MINIMUM NUMBER OF TAPCONS INTO CONCRETE & # 12 X 3/4" S.M.S. INTO UPRIGHT / EACH SIDE OF BEAM THROUGH SECONDARY 2" X 2" X 0.125" ANGLES (SEE BELOW) 2X4 S.M.B. (1) 1 /4" X 2-1 /4" S.S. TAPCON & (2) # 12 X 3/4" S.M.S. 2X5 S.M.B. (1) 1 /4" X 2-1 /4" S.S. TAPCON & (2) # 12 X 3/4" S.M.S. 2X6 S.M.B. (2) 1 /4" X 2-1/4" S.S. TAPCON & (3) # 12 X 3/4" S.M.S. 2X7 S.M.B. (2) 1 /4" X 2-1 /4" S.S. TAPCON & (4) # 12 X 3/4" S.M.S. 2X8 S.M.B. (3) 1 /4" X 2-1/4" S.S. TAPCON & (5) # 12 X 3/4" S.M.S. 2X9 S.M.B. (4) 1 /4" X 2-1/4" S.S. TAPCON & (6) # 12 X 3/4" S.M.S. 2X10 S.M.B. (5) 1 /4" X 2-1/4" S.S. TAPCON & (7) # 12 X 3/4" S.M.S. 1/9'xZkK' ANGLE 5032 H-32 ANGLE (2) - # 12 SMS INTO COLUMN 1 /4" MASONRY ANCHOR EACH ANGLE - EACH SIDE COL. 2-1 /4" MIN. CONC. ANCHOR EMBEDMENT @ SECONDARY ANGLE • e e 3000 PSI CONC. SLAB/FTG. 6x6-10x10 WWM OR FIBERMESH 1/4" MASONRY ANCHOR AT EACH ANGLE SELF -MATING OR SNAP SECTION TYP. 1'k2' O.B. BASE PLATE-TYP. 0 0 0 e N ° SIDE VIEW 2" REVEAL TYP. 1-114" MIN. CONC. ANCHOR EMBEDMENT @ 1'k2" O.B. LOCATION TYP. Z' MIN. INCREASE DISTANCE WHEN GREATER THAN 2x4 UPRIGHT IS USED NOTE WHERE PAVERS ARE PRESENT USE 5/16" TAPCON XL (RED HEAD MFG.) MASONRY ANCHORS TO PENETRATE UNDERLYING CONCRETE FOOTING 2-1 /4" (MIN.) (2) - #12 SMS 1 /4" TAPCON XL (RED HEAD MFG. OR EQUAL) 2 @ 1x2 BASE 2 @ SLAB (BEYOND) n e e 3000 PSI CONC. SLAB/FTG. 6x6-10x10 WWM FRONT VIEW OR FIBERMESH DETAIL "B" - 2"x4" OR LARGER SELF MATING UPRIGHT TO DECK DETAILS SCALE: NTS 2 INT( INSTAI TO (2) #10x3" SMS INTO SCREW BOSSES FOR EDGE MEMBER EDGE MEMBER o OR PURLIN 00 -E EDGE MEMBER OR PURLIN 0.0625" 6063-T6 FLAT PLATE w/(8) #10x.75' SMS, MIN..5' EDGE DISTANCE, PLATE MAY BE FASTENED INTERNALLY TO BRACE DETAIL "D" - ROOF BRACING CONNECTION SCALE: NTS FASTEN TOP OF HEADER TO INTERSECTING Z'x2" MEMBER w/(2) # 10 SMS w/1" PENETRATION INTO SCREW BOSS OF Z'x2" MEMBER - TYP. BOTH SIDES ZS<Z' DOOR JAMB 74� FASTEN HEADER w/(2) #lOx3" INTO SCREW BOSS OF HEADER ALTERNATE HEADER CONNECTION WHEN Z-BAR IS USED - FASTEN Z-BAR TO COL/HEADER AT EACH CORNER AND 18" O/C ALTERNATE BASE PLATE CONNECTION ATTACH Z'xZ' TO BASE PLATE (INTERNAL) w/(2) #IOxZ' SMS ATTACH BASE PLATE TO 2k2" w/(2) #1Ox3" SMS INTO SCREW BOSS OF BASE PLATE 1"xZ'BASE PLATE ANCHORED TO CONC w/ 1 /4" MASONRY ANCHOR 6" MAX EACH SIDE a .. • ° . > e OF POST AND 24" O.C. MAX a • e e n a e n 1-1 /4" CONC. EMBEDMENT TYP. •e , e . e 1/4" TAPCON (RED HEAD MFG. OR EQUAL) WITHIN 6" OF COLUMN 1-1/4" PENETRATION INTO UNDERLYING FOOTING DETAIL " F" - DOOR JAMB & HEADER CONNECTION SCALE: NTS ALUMINUM MEMBERS DIMENSIONS HOLLOW SECTIONS 2x2:2"x2"x0.050" 2x3:2"x3"x0.050" 2x4:2"x4"x0.050" 2 x 5: 2" x 5" x 0.050" OPEN BACK SECTIONS 1 x2: 1"x2"x0.044" 1 x3: 1"x3"x0.045" SNAP SECTIONS 2X2SNAP: 2"x2"x0.045" 2 x 3 SNAP: 2"x3"x0.050" 2x4SNAP: 2"x4"x0.045" SELF MATING (SMB) 2X4SMB: 2"x4"x0.046"x0.100" 2 x 5 SMB: 2" x 5" x 0.050" x 0. 116" 2 x 6 SM B: 2" x 6" x 0.050" x 0. 120" 2X7SMB:2"x7"x0.055"x0.129' 2 x 8 SMB: 2"x8"x0.072"x0.224" 2 x 9 SMB: 2" x 9" x 0.072" x 0.224" 2 x 9(H) SMB: 2" x 9" x 0.082" x 0.306" 2 x 10 SMB: 2" x 10" x 0.092" x 0.374" DETAIL A ALUMINUM INTERNAL OR EXTERNAL RECEIVING CHANNELw/(4) #10x.75" INTO GIRT OR PURLIN 8. (2) #14x.75" INTO BEAM OR UPRIGHT 0.062 ANGLE CLIPS MAYBE USED UPRIGHT, BEAM -SNAP, SELF MATING, OR HOLLOW \o\ 111111 I I I I///////// (� ��•� ••N• •LL _� w oo O O H- v> ' z U) �c . �L (4) # 1 0xl-1 /2" SMS INTO SCREW BOSSES PURLIN MEMBER DETAIL "C" - GIRT OR PURLIN TO BEAM OR POST DETAIL SCALE: NTS 2'k2'k.063"- DIM. TO MATCH PURLIN SIZE RECEIVING CHANNEL (2) # (3) # 12 EACH SIDE INTO PURLIN y o Z P�RUN '7i o EAVE RAIL- SEE PLAN _/ 0 EXTRUSION lx2 OPEN BACK UPRIGHT EXTRUSION (2) #IOxZ'SMS THRU 1x21NTO EAVE RAIL EACH SIDE OF COLUMN DETAIL "G" - SLOPED PURLIN CONNECTION SCALE: NTS V N J 0 Lf) J M co I— z co Z Z Q E o 0 U WJOoo� W J � u. •� � � W I" M C Z W Oc' � Q� 0 Q = Or elf J D_ L O N o C= c N w c" ri C N L-) m Lu acm c O Al N 00 r- 0 fM W U U N Tr9 Lid 00 N_ N J Q Z U o~o W cM Q LL w = U Z � w W > pd o V o 6I— o H ZOO QMLL O � O a DESIGN DATE: 11/16/2021 REVISION 1: 12/01/2021 REVISION 2: DATE SHEET: 04 DRAWN BY: ST SCALE: NTS GIRT FASTENED INTERNALLY AT EACH END w/ #IOxl.5" EACH SCREW GROOVE. FASTEN TO BEAM w/ 2'59" SKl /&' ANGLE (2) #12 SMS INTO BEAM & (2) #10xl.5 THRU ANGLE INTO GUTTER WHERE NO GIRT IS PRESENT, ATTACH ANGLE DIRECTLY TO GUTTER Z5a2 fl /8" ANGLE w/(2) # 12 SMS EACH LEG BEAM I o 1`xS'x2" WIDTH EXTRUDED GUTTER BRACKET (THICKNESS OF LEG @ WOOD SCREW SHALL BE 0.125" MIN., LONG LEG SHALL BE 0.072' MIN.) @ EACH BEAM w/(2) #12x3/4" SMS @ 1" SPACING INTO GUTTER LIP. FOR BEAMS ABOVE 2x8 INSTALL GUTTER BRACE AT MIDPOINT BETWEEN BEAMS & INCLUDE 2" GUTTER BRACE AT EACH BEAM LOCATION. EXISTING HOST STRUCTURE (DESIGNED BY OTHERS) —(2) #12 SMS -WOOD SCREWS @ SPACING SPACICI BRACKET @EACH GUTTER BRACKET & (1) @ 18" O.C. MAX. 0 0 o MIN. EMBEDMENT SHALL BE 2' CLOSE BOTTOM OF BEAM WHEN TRIMMED .044 RECEIVING CHANNEL, FASTEN w/(2) # 12 SMS EACH SIDE OF BEAM OPTIONAL GIRT #10SMS WITHIN 6" & @ 24" O.C. MAX. -\ 2x2xl /8" ANGLE EA. SIDE OF BEAM w/(2) # 12 SMS EACH LEG EACH SIDE FOR BEAM OVER 2x5 .044 RECEIVING CHANNEL FASTEN TO STRUCTURAL GUTTER INTERNALLY w/(2) # 12 SMS ALTERNATELY W-xl /&' ANGLE BELOW GIRT, (2) # 14 SMS INTO BEAM & (2) # 12 SMS INTO STRUCTURAL GUTTER SIDE VIEW TOP VIEW DETAIL "H" BEAM TO GUTTER CONNECTION SCALE: NTS FASTEN GUTTER TO FASCIA w/ # 14x2' WOOD SCREW 18" O.C. (2) #12SMS (2) #14x2' WOOD SCREW @ 1" SPACING =ASCIA (2)&' MIN. EXISTING) STRUCTURAL GUTTER — F o o 0 0 0 ° IF 0 0 o ° 0 0 jo o°o 0 0 0 0 0 10 0o F F 3/16-5052-H32 GUSSET °i ° F INTERNAL OR EXTERNAL 2 x 10 SMB ILLUSTRATED F NOTE F INSTALL FASTENERS ALONG PERIMETER OF GUSSET -BEAM JOINT 3/8" MIN, FROM EDGE. FASTENERS MAY BE STAGGERED TO INSURE PROPER QUANTITY PER TABLE B-1 FASTENER PATTERN MAY APPEAR DIFFERENT FROM ILLUSTRATION. MAINTAIN 1/2"SEPARATION BETWEEN FASTENERS. MAINTAIN 3/8" MIN, FASTENER SEPARATION FROM BEAM JOINT OR EDGE OF BEAM LAP FASTENERS MAY BE EVENLY SPACED AROUND EDGE OF GUSSET WITHIN 3/8" OF BEAM JOINT. FASTENERS MAY BE STAGGERED TO INSURE PROPER QUANTITY PER TABLE B-1 TABLE B-1 BEAM SIZE COL. TO BEAM QTY SMS/ SIDE OF COL. BEAM TO BEAM QTY SMS/ EA. FACE/SIDE 2x4 (5) #12 (9) #12 2x5 (5) #12 (9) #12 2x6 (7) #12 (9) #12 2x7 (10) #12 (10) #12 2x8 (12) #12 (14) #12 2x9 (14) #14 (14) #14 2x 10 (16) #14 (15) #14 DETAIL "K" GUSSET CONNECTION SCALE: NTS .050" GUTTER STIFFNER FASTEN TO FASCIA w(2) #12x2" WOOD SCREW FASTEN TO GUTTER w(2) #12SMS . . GUTTER 6 BR CE Iol WHEN BEAM & PURLIN HIT ON CORNER - FASTEN OUTSIDE OF BEAM & PURLIN w/ 11&'x2'x2" ANGLE & (4) # 12 SMS EACH LEG FASTEN INSIDE CORNER (BEAM TO PURLIN) w/1/6xZc c2'ANGLE w/(2) # 12 SMS INTO EA. MEMBER (BEAM & PURLIN) DETAIL "M" BEAM & PURLIN TO GUTTER CONNECTION SCALE: NTS 2'x2'xl/8" ANGLE w/(2) #12SMS EA. LEG 1 /8"xn2l" STRAP (2) # 12 SMS INTO BEAM (2) #12 SMS INTO GUTTER (2) #12SMS \ GIRT SMB ° o 0 0 0 7<2'xl/8" ANGLE w/(2) # 12 SMS EA. LEG SMB (2) #14 WOOD SCREWS INTO FASCIA SIDE VIEW GIRT FASCIA o GUTTER Q BRACE (2) # 12 SMS U �a c� m GIRT STRUCTURAL GUTTER (2) GUTTER BRACES EACH w/(2) #12 SMS INTO GUTTER & (2) #14 WOOD SCREWS INTO FASCIA 1/8Vk K4"STRAP GIRT (2) # 12 SMS INTO BEAM STRUCTURAL GUTTER (2) # 12 SMS INTO GUTTER TOP VIEW DETAIL "L" CORNER CONNECTION SCALE: NTS (9) #14x3/4"SMS 1/8" PLATE ON 45° ANGLES OR 1 /&<2'x2' ANGLE w/(4) # 12 SMS INTO EACH INTERSECTING MEMBER o o o FRAMING o /0 0 0 DETAIL "1-2" CABLE CONNECTION AT CORNER SCALE: NTS 40° MIN. 60° MAX./ o d. 3000 PSI CONC. 6x6-1Ox10 WWM OR FIBERMESH 40° MIN. 60° MAX. 1 /8" STAINLESS STEEL BRAIDED CABLE \\00�11111111//cli / ci �o . Nip --,; W _ - :LU (oQ o Ui 1I U c, O M F- c zz <_ O D U U w U w J 0o EYEBOLT FOR W LL. r • CABLE TENSION 7 1/8" STAINLESS STEEL L ~ M BRAIDED CABLE �•� G WC r 0�m��- 00 04 LL 3" A.S.T.M. A-36 STEEL CLIP WITH (2) 3/&K3' SLEEVE ANCHORS FOR PAVERS (2) 1/4X6"TAPCONS THRU PAVERS INTO FOOTING 1/8" STAINLESS STEEL BRAIDED CABLE 3000 PSI CONC. 6x6-I0x10 3/8"DIA x 3" EMBED WWM OR FIBERMESH CONC. SCREW ANCHOR (TAPCON OR EQUAL) 1 /8" STAINLESS STEEL BRAIDED CABLE 40° MIN. 60' MAX. 3000 PSI CONC. 6x6-1 Ox10 1.S5.S' ALUM. STRAP WWM OR FIBERMESH w/(2) 3/8" DIA. x 3" MASONRY ANCHOR (TAPCON OR EQUAL) DETAIL "I-1" CABLE CONNECTION AT FOUNDATION SCALE: NTS v O U W CL J Z U� W � cM Q ILL. W_ U = Z � F- c w }' O a ❑ �c�I— U O U) Q Z O O W J O Faw- z O O U d DESIGN DATE: 11/16/2021 REVISION 1: 12/01/2021 REVISION 2: DATE SHEET: 0 DRAWN BY: ST SCALE: NTS 024 FLASHING SEALED TO WALL (TYP.) EXISTING RAFTER c° OR TRUSS O #14x1/7' S.M.S. W/ INTEGRAL 3/4"0 #14xl/2' S.M.S. W/ INTEGRAL 3/4"0 WASHER AND NEOPRENE GASKET @ 12" O.C., TOP & BOTTOM. O < WASHER AND NEOPRENE GASKET O TOP @ 17' O.C., TOP & BOTTOM O O IF CLEARANCE PROHIBITS INSTALLATION OF O FASTENERS USE # 14x4" S.M.S. W/ 1-1 /4" 0 FENDER WASHER AND NEOPRENE GASKET @ 17' O.C. EXTRUDED OR BRAKE -FORMED ROOF HEADER OR RECEIVING CHANNEL (0.044" MIN. THICKNESS) s EXTRUDED OR BRAKE -FORMED ROOF HEADER SECURE FASCIA TO EACH WITH MIN. 1-1 /2' BEARING LEG. OR RECEIVING CHANNEL (0.044" MIN. THICKNESS) WITH MIN. 1-1/2' BEARING LEG. RAFTER TAIL W/ (1) 1/4" 0 x 4" LONG PAN HEAD LAG SCREWS (1) 1/4" 0 x 7' LAG SCREW @ 24" O.C. BEFORE ATTACHING REC. CHANNEL ENTIRE LENGTH OF RECEIVING CHANNEL HOST STRUCTURE 1 /4" 0 x 2-1 /2' LONG WOOD LAG SCREW OR ROOF PANEL ATTACHMENT - WOOD FRAME MASONRY: WOOD 1/4" 0 x 2-1 /4" LONG MASONRY ANCHORS @24"O.C.MAX. SCALE: N.T.S. ROOF PANEL ATTACHMENT - MASONRY SCALE: N.T.S. 2V'x.063" - DIM. TO MATCH PURLIN SIZE RECEIVING CHANNEL RAIL (3) INTERNAL INTO PURLIN AND NEO-PRENE GASKET @17' FENDER WASHER 1O.0 #12 EACH SIDE spURC1N S o ROOF PER PLAN o o CARRIER BEAM PER PLAN PURLIN TO CARRIER BEAM + SOLID ROOF CONNECTION SCALE: N.T.S. MKS3" WIDTH EXTRUDED GUTTER BRACKET (THICKNESS OF LEG @ #14xl"SHALL BE 0.125" MIN., LONG LEG SHALL BE 0.072" MIN.) @ 24" O.C. w/(2) #12x3/4" SMS @ 1" SPACING INTO GUTTER LIP (2) 3/8" DIA. MACHINE �— BOLTS THRU CARRIER 1'k5k2' WIDTH EXTRUDED GUTTER BRACKET ROOF CARRIER BEAM BEAM & POST THICKNESS OF LEG @ C.B. SCREW SHALL BE PER PLAN PER PLAN #14x4",5" OR 7"S,M.S.w/ 1-1/4" 0 FENDER WASHER AND NEO-PRENE GASKET @ 17' O.C. 0.125" MIN., LONG LEG SHALL BE 0.077' MIN.) @ EACH BEAM w/(2) #12x3/4" SMS @ 1" SPACING 3X3 OR 4X4 #12 X 9/16" W/ 5/8" NEO-WASHER INTO GUTTER UP. (2) #14 SMS OT TEK SCREWS @ 1" (3) PER PAN FOR PANS SPACING @ EACH GUTTER BRACKET & (1) @ 18" O.C. POST PER PLAN MAX. (SEE NOTE) #14x4",5 OR 7"w/ FENDER WASHER NOTE• AND ND NEO-PRENE RENE G GASKET @ 12" O.C. BEAM TO POST CONNECTION #1 DETAIL SCALE: N.T.S. CARRIER PER 3X3 OF POST PER I (2) 3/8" DIA. MACHINE BOLTS THRU CARRIER BEAM & POST BEAM TO POST CONNECTION #2 DETAIL SCALE: N.T.S. 2"X2'X.125" ANGLE W/ # 14x3/4" THRU ANGLE LEG INTO BEAM EA. SIDE TYP. SEE TABLE FOR QUANTITY 2"X7'X.125" ANGLE W/ (3) 1 /4" X 2-1/4' TAPCONS @ 7' o.c. THRU ANGLE LEG INTO HOST WALL TOP VIEW Lu U H ROOF PER PLAN FOR BEAMS ABOVE 2x8 INSTALL GUTTER BRACE AT MIDPOINT BETWEEN BEAMS & INCLUDE 2" GUTTER BRACE AT EACH BEAM LOCATION CAGE 'FOR 2X9 AND 2X10 (2) 3/8" THRU-BOLT BEAM USE #14INTO BEAM THRU CARRIER BEAM STRUC. i I (O HOST & POSTS GUTTER INTO HOST 2-1 /4" MIN. GIRT FASTENED INTERNALLY AT EACH END w/ # 1 Oxl.5" EACH SCREW GROOVE. FASTEN TO BEAM w/ 252 xI /8" ANGLE (2) # 12 SMS POST INTO BEAM & (2) #1Ox1.5 THRU ANGLE INTO GUTTER WHERE NO GIRT IS PRESENT, ATTACH 3X3 OR 4X4 SIDE VIEW ANGLE DIRECTLY TO GUTTER POST PER PLAN FOR BEAM OVER 2x5 .044 RECEIVING CHANNEL FASTEN TO STRUCTURAL GUTTER INTERNALLY w/(2) # 12 SMS ALTERNATELY 2x2x1/&' ANGLE BELOW GIRT, (2) #14 SMS INTO BEAM & (2) #12 SMS INTO GUTTER ROOF PANEL TO CARRIER BEAM W/ GUTTER + ROOF BEAM CONNECTION SCALE: N.T.S. 0 BEAM PER PLAN (2X7SMB ILLUSTRATED) 7'X2X.I25" ANGLE W/ #14x3/4"THRUANGLELEG INTO BEAM EA. SIDE TYP. 0 SEE TABLE FOR QUANTITY / n2X.125" ANGLE W/ O2 (3) 1/4" X 2-114- TAPCONS @ 2" o.c. THRU ANGLE LEG INTO HOST WALL SIDE VIEW BEAM TO HOST WALL CONNECTION SCALE: N.T.S. FASTENER NOTES: MAINTAIN 1/7'SEPARATION BETWEEN FASTENERS. MAINTAIN 3/8" MIN, FASTENER SEPARATION FROM EDGE. FASTENERS MAY BE STAGGERED TO ENSURE PROPER QUANTITY PERMITTED (PATTERN MAY APPEAR DIFFERENT FROM ILUSTRATION) BEAM TO WALL W/ 1 X' ANGLE TABLE BEAM SIZE QUANTITY/ SIZE PER LEG TO BEAM QUANTITY ANCHOR PER LEG TO WALL 2X4 (4) #12-(2) #16 (2) 1/4"TAPCON 2X5 (5) # 12 - (3) # 16 (2) 1 /4" TAPCON 2X6 (5) # 12 - (3) # 16 (3) 1 /4" TAPCON 2X7 (6) #14-(4) #16 (3) 1/4"TAPCON 2X8 (7) # 14 - (4) # 16 j (4) 1 /4" TAPCON 2X9 (8) # 14 - (5) # 16 (4) 1/4" TAPCON 2X10 (9) # 14 - (6) # 16 (5) 1 /4" TAPCON FOR WOOD APPLICATION IN LIEU OF MASONRY ANCHORS USE: 1 /4" X 3" GALV. LAGS (4) 3/8" DIA. LDT'S 2-1/4" MIN. EMBEDMENT THRU BOTTOM LEG OF ANGLE INTO CONC. 3-3/4" FROM E OF SLAB/ FTG. (3) 1/4" DIA. MACHINE BOLTS w/ WASHERS (4) 3/8" DIA. LDT'S 2-1/4" MIN. EMBEDMENT THRU BOTTOM LEG OF ANGLE INTO CONC. 3000 PSI CONC. SLAB/FTG. 6x6-1Ox10 WWM OR FIBERMESH #12SMS 00 O 0 CARRIER BEAM PER PLAN FASTENED TO POST W/ (2) 3/8" DIA. MACHINE BOLTS THRU CARRIER BEAM & POST (2) #14xi"SMS OR TEK @ 1" SPACING @ EACH GUTTER BRACKET & (1) @ 18" O.C. MAX. 2k2KO.125" ANGLE EACH SIDE TYP. ROOF BEAM (SLOPED OR FLAT) 3/4" SMS SEE TABLE FOR QUANTITY (TYP. EACH SIDE) 3/4" SMS SEE TABLE FOR QUANTITY (TYP. EACH SIDE) zZ:Co co O =0:W C) FW- Q— %,��.� ......PROF //1111111111\ ROOF BEAM TO C.B. W/ 1 /8" ANGLE TABLE BEAM SIZE QUANTITY/ SIZE EA. LEG TO BEAM 2x4 (4) #12OR (2) # 16 2x5 (5) 412OR (3) # 16 2 x 6 (5) # 12 OR (3) # 16 2x7 (6) # 14 OR (4) # 16 2 x 8 (7) # 14 OR (4) # 16 2X9 (8) #14OR (5) # 16 2xl0 (9)#140R(6)#16 ROOF BEAM TO CARRIER BEAM w/ STRUC. GUTTER CONNECTION DETAIL SCALE: NTS MAY USE (4) #14Xl"TEK IN LIEU OF THRUBOLTS MAY USE (4) #14XV TEK (3) 1/4" DIA. MACHINE (4) 3/8" DIA. LDT'S IN LIEU OF THRUBOLTS BOLTS w/ WASHERS 2-1/4" MIN. EMBEDMENT THRU BOTTOM LEG OF 1" \O ® ANGLE INTO CONC. (3) 1/4" DIA. MACHINE ® ® BOLTS w/ WASHERS 2" 3-3/4" FROM EDG r TOP VIEW OF SLAB/FTG. TOP VIEW 4'k4" POST (SEE PAGE-2 FOR SIZE) n4KO.125 ANGLE FRONT VIEW 4X4 COLUMN ALT. BASE ATTACHMENT DETAIL SCALE: NTS COLUMN PER PLAN (3) 1/4" DIA. MACHINE BOLTS w/ WASHERS 1 /8'XYk2'k3-3/4" (4) 3/8" DIA. LDT'S (LENGTH) ANGLE 2-1X MIN. EMBEDMENT (INTERNAL) THRU BOTTOM LEG OF ANGLE INTO CONC. a •e a , n 3000 PSI CONC. ° SLAB/FTG. 6x6-IOxIO WWM FRONT VIEW OR FIBERMESH 4"x4" POST CONNECTION DETAIL SCALE: NTS J O Lo J rn co I- co Z Z Q E U U Lu O 00 W QJ 1) LL LoLLI LL ~_ r 0) cM z w Q O 4— U O(O J � 0.. �. L C) .— o N O � 6V w rn W co H �10 N co r- 0 W U U N ILO 00 N T_ 04 O z U w O ry IL