Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Mark Smith Workshop
Builder Name:
Street: 5205 Deer Run Drive
Permit Office: St. Lucie County
City, State, Zip: Fort Pierce, FL, 34951
Permit Number:
Owner: Mark Smith
Jurisdiction: St. Lucie County
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type41270.0 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Polystyrene Bead AggR=9.1 960.00 ft2
b. Frame - Wood, Adjacent
R=11.0 310.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 0
d. N/A
R= ft2
5. Is this a worst case? No
11. Ceiling Types (720.0 sqft.)
Insulation Area
a. Roof Deck (Unvented)
R=20.0 720.00 ft2
6. Conditioned floor area above grade (ft2) 720
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(30.0 sqft.) Description Area
12. Ducts
a. Sup: Attic, Ret: Attic, AH: Workshop
R ft2
6 40
a. U-Factor: Sgl, U=0.58 30.00 ft2
SHGC: SHGC=0.24
b. U-Factor: N/A ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
18.8 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
Area Weighted Average Overhang Depth: 1.417 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.240
a. Electric Strip Heat
17.0 COP:1.00
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric Tankless
Cap: 1 gallons
9. Floor Types (720.0 sqft.) Insulation Area
EF: 0.950
a. Slab -On -Grade Edge Insulation R=0.0 720.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
CF, Pstat
Glass/Floor Area: 0.042 Total Proposed Modified Loads: 22.69
PASS
Total Baseline Loads: 26.85
I hereby certify that the plans and specifications covered by
Review of the plans and
t 1C.SaT,
this calculation are in compliance with the Florida Energy
specifications covered by this�y'©
Code.
calculation indicates compliance
with the Florida Energy Code.
F+ trf�zz °` .; •``�ti CO
PREPARED BY:
Before construction is completed
DATE: 12-9-20211
this building will be inspected for
compliance with Section 553.908
*:
hereby certify that this compliance build' as de i ned s in
g'c�D
Florida Statutes.
with the Florida Energy Co
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
12/8/2021 12:51 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Mark Smith Workshop
Bedrooms: 0
Address Type: Street Address
Building Type:
User
Conditioned Area: 720
Lot #
Owner Name:
Mark Smith
Total Stories: 1
Block/Subdivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street: 5205 Deer Run Drive
Permit Office:
St. Lucie County
Cross Ventilation: No
County: St. Lucie
Jurisdiction:
St. Lucie County
Whole House Fan: No
City, State, Zip: Fort Pierce ,
Family Type:
Detached
FL, 34951
New/Existing:
New (From Plans)
Comment:
CLIMATE
V
Design Temp
Int Design Temp Heating Design Daily Temp
Design
Location
TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70
75 299 62 Low
BLOCKS
Number
Name
Area Volume
1
Entire House
720 7200
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Workshop
660 6600 No 3
1 Yes Yes Yes
2
Bath
60 600 No 2
1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Workshop 79 ft
660 ft'
---- 1 0 0
2 Slab -On -Grade Edge Insulatio Bath 17 ft
60 ft'
---- 1 0 0
ROOF
Roof Gable Roof
Red
Solar SA Emitt Emitt Deck Pitch
#
Type
Materials Area Area Color
Barr
Absor. Tested Tested Insul. (deg)
1
Hip
Metal 780 ftz 0 ft' Medium
N
0.6 No 0.9 No 20 22.62
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Unvented 0
720 ftZ
N N
12/8/2021 12:51 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
CEILING
#
Ceiling Type Space R-Value Ins Type Area
Framing Frac Truss Type
1
2
Under Attic (Unvented) Workshop 0 Blown 660 ftz
Under Attic (Unvented) Bath 0 Blown 60 ft2
0.1 Wood
0.1 Wood
WALLS
Adjacent Space Cavity Width Height
Sheathing Framing Solar
Below
1
2
_ 3
4
5
6
7
N
S
W
E
S
N
E
Exterior Concrete Block - Polystyr>>?+Drkshop 9.1 20 0 10 0 200.0 ft'
Exterior Concrete Block - PolystyrWorkshop 9.1 35 0 10 0 350.0 ft'
Exterior Concrete Block - PolystyWorkshop 9.1 24 0 10 0 240.0 ft'
Exterior Concrete Block - PolystyrenBath 9.1 12 0 10 0 120.0 ft'
Exterior Concrete Block - PolystyrenBath 9.1 5 0 10 0 50.0 ft'
Garage Frame - Wood Workshop 11 12 10 120.0 ftZ
Garage Frame - Wood Workshop 11 19 10 190.0 ftZ
0 0 0.6
0 0 0.6
0 0 0.6
0 0 0.6
0 0 0.6
0.23 0.6
0.23 0.65
0
0
0
0
0
0
0
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
V
#
Wall Overhang
Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
1
2
S 2 Metal Low-E Single Yes 0.58 0.24 Y 15.0 ft' 1 ft 5 in
W 3 Metal Low-E Single Yes 0.58 0.24 Y 15.0 ft' 1 ft 5 in
1 ft 4 in None
1 ft 4 in None
None
None
GARAGE
#
Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height
Exposed Wall Insulation
1
228 ftZ 228 ftZ 64 ft 8 ft
1
INFILTRATION
#
Scope
Method SLA CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000444 840 46.08 86.52 .1381
7
HEATING SYSTEM
#
System Type Subtype Speed Efficiency Capacity
Block
Ducts
1
Electric Strip Heat/ None COP:1 17 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit/ Split Singl SEER: 16 18.8 kBtu/hr
cfm 0.7 1
sys#1
12/8/2021 12:51 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# System Type
SubType
Location
EF
Cap
Use
SetPnt
Conservation
1 Electric
Tankless
Workshop
0.95
1 gal
60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System
Model # Collector Model
# Area
Volume
FEF
None None
ft2
DUCTS
-- Supply --
V
—
Return --
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT QN RLF
Heat Cool
1 Attic
6 40 ft2
Attic
10 ft2
Default Leakage
Workshop
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Coolin Jan Feb
Heating Jan Feb
Mar
Mar
A r
Apr
Ma
May
Jun [X Jul
Jun [ Jul
ri
Au
Aug
X Se
Sep
Oct
Oct
Nov
Nov
Dec
Dec
Venting Jan Feb
XMar
Apr
May
Jun [ Jul
Aug
Sep
Oct X
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8
9
10
11
12
Cooling (WD) AM
78
78
78
78
78 78
78
78
80
80
80
80
PM
80
80
78
78
78 78
78
78
78
78
78
78
Cooling (WEH) AM
78
78
78
78
78 78
78
78
78
78
78
78
PM
78
78
78
78
78 78
78
78
78
78
78
78
Heating (WD) AM
66
66
66
66
66 68
68
68
68
68
68
68
PM
68
68
68
68
68 68
68
68
68
68
66
66
Heating (WEH) AM
66
66
66
66
66 68
68
68
68
68
68
68
PM
68
68
68
68
68 68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
Pool Cabana
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Cabana
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Kitchenette
Default(8 Ibs/sq.ft.
ft2
ft
0.3
AHU
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bath
Default(8 Ibs/s .ft.
ft2
ft
0.3
Pool Cab
12/8/2021 12:51 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Mark Smith Workshop Builder Name:
Street: 5205 Deer Run Drive Permit Office: St. Lucie County
City, State, Zip: Fort Pierce , FL , 34951 Permit Number:
Y
U
Owner: Mark Smith Jurisdiction: St. Lucie County
w
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the finished surface.
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
F--Ytpnri behind nopffing and wiring,
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub -floor, wall covering or
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
I
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover i3lates and walls or ce*l*nas,
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
12/8/2021 12:52 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 85
The lower the EnergyPerformance Index, the more efficient the home.
5205 Deer Ruh Drive, Fort Pierce, FL, 34951
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Polystyrene Bead AggR=9.1
960.00 ft2
b. Frame - Wood, Adjacent
R=11.0
310.00 ft2
3. Number of units, if multiple family
1
c. N/A
R=
ft2
4. Number of Bedrooms
0
d. N/A
R=
ft2
11. Ceiling Type and insulation level
Insulation
Area
5. Is this a worst case?
No
a. Roof Deck (Unvented)
R=20.0
720.00 ft2
6. Conditioned floor area (ft2)
720
b. N/A
R=
ft2
c. N/A
R=
ft2
7. Windows- Description
Area
12. Ducts, location & insulation level
R ft2
a. U-Factor: Sgl, U=0.58
30.00 ft2
a. Sup: Attic, Ret: Attic, AH: Workshop
6 40
SHGC: SHGC=0.24
b. U-Factor: N/A
ft2
SHGC:
13. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: N/A
ft2
a. Central Unit
18.8 SEER:16.00
SHGC:
d. U-Factor: N/A
ft2
14. Heating systems
kBtu/hr
Efficiency
SHGC:
a. Electric Strip Heat
17.0
COP:1.00
Area Weighted Average Overhang Depth:
1.417 ft.
Area Weighted Average SHGC:
0.240
8. Skylights Description
Area
15. Hot water systems
Cap:
1 gallons
a. U-Factor(AVG): N/A
ft2
a. Electric
EF: 0.95
SHGC(AVG): N/A
b. Conservation features
9. Floor Types
Insulation
Area
None
a. Slab -On -Grade Edge Insulation
R=0.0
720.00 ft2
Credits (Performance method)
CF, Pstat
b. N/A
R=
ft2
c. N/A
R=
ft2
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the aN/f,/
rgy saving features which will be installed (or exceeded)
in this home before final inOtherwise, a new EPL Display Card will be completed
based on installed Code ceatu es.
Builder Signature: Date: Z 1 4-
v�
Address of New Home: - et L City/FL Zip: Elel�ce
311-119s%
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
12/8/2021 12:52 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1