Loading...
HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Mark Smith Workshop Builder Name: Street: 5205 Deer Run Drive Permit Office: St. Lucie County City, State, Zip: Fort Pierce, FL, 34951 Permit Number: Owner: Mark Smith Jurisdiction: St. Lucie County Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type41270.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Polystyrene Bead AggR=9.1 960.00 ft2 b. Frame - Wood, Adjacent R=11.0 310.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 0 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types (720.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=20.0 720.00 ft2 6. Conditioned floor area above grade (ft2) 720 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(30.0 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: Workshop R ft2 6 40 a. U-Factor: Sgl, U=0.58 30.00 ft2 SHGC: SHGC=0.24 b. U-Factor: N/A ft2 13. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 18.8 SEER:16.00 c. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 1.417 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.240 a. Electric Strip Heat 17.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Tankless Cap: 1 gallons 9. Floor Types (720.0 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 720.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits CF, Pstat Glass/Floor Area: 0.042 Total Proposed Modified Loads: 22.69 PASS Total Baseline Loads: 26.85 I hereby certify that the plans and specifications covered by Review of the plans and t 1C.SaT, this calculation are in compliance with the Florida Energy specifications covered by this�y'© Code. calculation indicates compliance with the Florida Energy Code. F+ trf�zz °` .; •``�ti CO PREPARED BY: Before construction is completed DATE: 12-9-20211 this building will be inspected for compliance with Section 553.908 *: hereby certify that this compliance build' as de i ned s in g'c�D Florida Statutes. with the Florida Energy Co OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 12/8/2021 12:51 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Mark Smith Workshop Bedrooms: 0 Address Type: Street Address Building Type: User Conditioned Area: 720 Lot # Owner Name: Mark Smith Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 5205 Deer Run Drive Permit Office: St. Lucie County Cross Ventilation: No County: St. Lucie Jurisdiction: St. Lucie County Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Detached FL, 34951 New/Existing: New (From Plans) Comment: CLIMATE V Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 720 7200 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Workshop 660 6600 No 3 1 Yes Yes Yes 2 Bath 60 600 No 2 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Workshop 79 ft 660 ft' ---- 1 0 0 2 Slab -On -Grade Edge Insulatio Bath 17 ft 60 ft' ---- 1 0 0 ROOF Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 780 ftz 0 ft' Medium N 0.6 No 0.9 No 20 22.62 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 720 ftZ N N 12/8/2021 12:51 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 2 Under Attic (Unvented) Workshop 0 Blown 660 ftz Under Attic (Unvented) Bath 0 Blown 60 ft2 0.1 Wood 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 2 _ 3 4 5 6 7 N S W E S N E Exterior Concrete Block - Polystyr>>?+Drkshop 9.1 20 0 10 0 200.0 ft' Exterior Concrete Block - PolystyrWorkshop 9.1 35 0 10 0 350.0 ft' Exterior Concrete Block - PolystyWorkshop 9.1 24 0 10 0 240.0 ft' Exterior Concrete Block - PolystyrenBath 9.1 12 0 10 0 120.0 ft' Exterior Concrete Block - PolystyrenBath 9.1 5 0 10 0 50.0 ft' Garage Frame - Wood Workshop 11 12 10 120.0 ftZ Garage Frame - Wood Workshop 11 19 10 190.0 ftZ 0 0 0.6 0 0 0.6 0 0 0.6 0 0 0.6 0 0 0.6 0.23 0.6 0.23 0.65 0 0 0 0 0 0 0 WINDOWS Orientation shown is the entered, Proposed orientation. / V # Wall Overhang Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 2 S 2 Metal Low-E Single Yes 0.58 0.24 Y 15.0 ft' 1 ft 5 in W 3 Metal Low-E Single Yes 0.58 0.24 Y 15.0 ft' 1 ft 5 in 1 ft 4 in None 1 ft 4 in None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 228 ftZ 228 ftZ 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000444 840 46.08 86.52 .1381 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 17 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 18.8 kBtu/hr cfm 0.7 1 sys#1 12/8/2021 12:51 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric Tankless Workshop 0.95 1 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS -- Supply -- V — Return -- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 40 ft2 Attic 10 ft2 Default Leakage Workshop (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Coolin Jan Feb Heating Jan Feb Mar Mar A r Apr Ma May Jun [X Jul Jun [ Jul ri Au Aug X Se Sep Oct Oct Nov Nov Dec Dec Venting Jan Feb XMar Apr May Jun [ Jul Aug Sep Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Pool Cabana Default(8 Ibs/sq.ft. ft2 ft 0.3 Cabana Default(8 Ibs/sq.ft. ft2 ft 0.3 Kitchenette Default(8 Ibs/sq.ft. ft2 ft 0.3 AHU Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath Default(8 Ibs/s .ft. ft2 ft 0.3 Pool Cab 12/8/2021 12:51 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Mark Smith Workshop Builder Name: Street: 5205 Deer Run Drive Permit Office: St. Lucie County City, State, Zip: Fort Pierce , FL , 34951 Permit Number: Y U Owner: Mark Smith Jurisdiction: St. Lucie County w Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall F--Ytpnri behind nopffing and wiring, Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. I Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover i3lates and walls or ce*l*nas, a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 12/8/2021 12:52 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 85 The lower the EnergyPerformance Index, the more efficient the home. 5205 Deer Ruh Drive, Fort Pierce, FL, 34951 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Polystyrene Bead AggR=9.1 960.00 ft2 b. Frame - Wood, Adjacent R=11.0 310.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 0 d. N/A R= ft2 11. Ceiling Type and insulation level Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 720.00 ft2 6. Conditioned floor area (ft2) 720 b. N/A R= ft2 c. N/A R= ft2 7. Windows- Description Area 12. Ducts, location & insulation level R ft2 a. U-Factor: Sgl, U=0.58 30.00 ft2 a. Sup: Attic, Ret: Attic, AH: Workshop 6 40 SHGC: SHGC=0.24 b. U-Factor: N/A ft2 SHGC: 13. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 18.8 SEER:16.00 SHGC: d. U-Factor: N/A ft2 14. Heating systems kBtu/hr Efficiency SHGC: a. Electric Strip Heat 17.0 COP:1.00 Area Weighted Average Overhang Depth: 1.417 ft. Area Weighted Average SHGC: 0.240 8. Skylights Description Area 15. Hot water systems Cap: 1 gallons a. U-Factor(AVG): N/A ft2 a. Electric EF: 0.95 SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 720.00 ft2 Credits (Performance method) CF, Pstat b. N/A R= ft2 c. N/A R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the aN/f,/ rgy saving features which will be installed (or exceeded) in this home before final inOtherwise, a new EPL Display Card will be completed based on installed Code ceatu es. Builder Signature: Date: Z 1 4- v� Address of New Home: - et L City/FL Zip: Elel�ce 311-119s% *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 12/8/2021 12:52 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1