Loading...
HomeMy WebLinkAboutAPPROVED BY WALTER P, RISER & LOAD CALCULATIONUnderground Overhead 1.Size Service: 2.Conductor Size:CU ALUM 3. a. Meter Main: b.Meter Can Only: M Grounding Electrode Conductor Size #6 #4 #2 Other CONSTRUCTION TYPE: Residential Mobile Home New Installation Old Installation Dual Electrodes or Test Required **RMC W/BOND BUSHING #6 GREEN EQUPMENT GROUNDING CONDUCTOR WILL BE RAN TO EXISTING PANEL BOARD. TERMINAL WILL BE INSTALLED IN EXISTING PANEL, ALL NEUTRIALS AND EQUPMENT GROUNDS WILL BE ISOLATED*BONDING SCREW OR BONDING STRAP WILL BE REMOVED. 150A RATED PANEL 150A MCB EXISTING 200AMAIN BREAKER 200AMPS 2/0 2" PVC CONDUIT SCH 40UNDERGROUND-SCH 80 EMERGING FROM GRADE *****GEC WILL BE SIZED BASED ON 250.66 (A) 2017 NEC CONNECTIONS TO A ROD, PIPE, OR PLATE ELECTRODE: THE GROUNDING ELECTRODE CONDUCTOR SHALL NOT BE ANY LARGER THAN 6AWG COPPER OR 4AWG ALUMINUM WIRE 200AMP METER COMBO Residential Optional Calculation 9/25/1997 OPTIONAL by: John Sokolik Version 2011 L STEP 1 Article 220.82 (B) (1),(2)SOUTHERN SHORES ELECTRIC CO standard 2301 General Lighting load 6,903 VA 1331 NE SUNRISE TER ahu 2 Small Appliance 3,000 VA JENSEN BEACH, FL, 34957 cool 1 Laundry circuit 1,500 VA (772)-353-0072 Gen.Lgt, Sm App.& Laun. Load 11,403 VA 11/12/2021 18:41 ahu hp STEP 2 Article 220.82 (C)General lighting, Sm. Appl. & Laundry 11,403 VA A/C Condenser & Fixed Electric Space Heating Total 1 ### 7,130 VA AHU 1 11,600 VA Heating Load 8,100 VA ### VA AHU 2 VA CU Load 8,730 VA ### VA AHU 3 VA ### VA AHU 4 VA Electric Space Heat @ 65% <4, 40% >3, vs. A/C @ 100%8,730 VA ### VA AHU 5 VA ### STEP 3 Article 220.82 (B) (3)Appliance Demand Load 15,944 VA ### 1 Water Heater 4,500 VA ### 1 Refrigerator 1,400 VA Dryer Demand Load 7,200 VA 0 Freezer VA DEM FACTOR 1 Dishwasher 1,400 VA Range Demand Load 8,000 VA ### 1 Disposal 690 VA <4 1 R / Hood 400 VA Service Demand 31,749 VA >3 1 Microwave 1,700 VA 0 Microwave VA Demand Load 132 A 0 Mini Refrig VA 0 Wine Clr VA Neutral Demand 87 A 0 Insta Hot VA 0 Ironing Center VA Min.Service Req.150 A Jacuzzi Tub VA Sprinkler Pump 1,127 VA Min. Feeder size 1 Well Pump 1,127 VA Min. Neutral size 3 Fountain Pump VA Eq. Grding Cond.6 Elevator VA Copper Pool Equip. Panel VA Apply Demand 3600 POOL PUMP 3,600 VA No Demand VA No Demand Total Appliance Load 15,944 VA STEP 4 Article 220.82 (B) (3) Electric Clothes Dryers 7,200 VA STEP 5 Article 220.82 (B) (3) Electric Ranges 8,000 W Col C demand 8000 Cooktop Col B demand Cooktop Col B demand Oven(s) Col B demand Oven(s) Col B demand Number of appliances 0 Dem. Factor Cooktop & Oven Demand Load >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>><<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<< Pool Panel Feeder Calculation (See Note)A B N Continuous Non-continuous Continuous Motors 0 . . . . . .0 0 0 Motors Motors Non-continuous 0 . . . . . .0 0 0 240v 240v Spa heater 11 kVA . . . . . .0 0 240v 240v Pool heater 3.5 ton . . . . . .0 0 240v 240v Pool heater 5 ton . . . . . .0 0 240v 240v Pool Light 0 . . . . . .0 0 0 240v 240v Blower 2333 0 240v 0 0 0 other load 0 240v 0 0 0 0.0 Motor Neutral Load other load 0 240v 0 0 0 Min.Copper Pool Feeder AWG A A A Max.Unbalanced Neutral Load Minimum Panel Rating A Phase Amperes Neut. load QTY or Number of appliances jmp1jds@comcast.net Check Box for Gas Range