HomeMy WebLinkAboutAPPROVED BY WALTER P, RISER & LOAD CALCULATIONUnderground
Overhead
1.Size Service:
2.Conductor Size:CU ALUM
3. a. Meter Main:
b.Meter Can Only:
M
Grounding Electrode Conductor Size
#6
#4
#2
Other
CONSTRUCTION TYPE:
Residential
Mobile Home
New Installation
Old Installation
Dual Electrodes or Test Required
**RMC W/BOND BUSHING #6 GREEN EQUPMENT GROUNDING CONDUCTOR WILL BE RAN TO EXISTING PANEL BOARD. TERMINAL WILL BE INSTALLED IN EXISTING PANEL, ALL NEUTRIALS AND EQUPMENT GROUNDS WILL BE ISOLATED*BONDING SCREW OR BONDING STRAP WILL BE REMOVED.
150A RATED PANEL 150A MCB EXISTING
200AMAIN BREAKER
200AMPS
2/0
2" PVC CONDUIT SCH 40UNDERGROUND-SCH 80 EMERGING FROM GRADE
*****GEC WILL BE SIZED
BASED ON 250.66 (A) 2017
NEC
CONNECTIONS TO A ROD,
PIPE, OR PLATE
ELECTRODE: THE
GROUNDING ELECTRODE
CONDUCTOR SHALL NOT
BE ANY LARGER THAN
6AWG COPPER OR 4AWG
ALUMINUM WIRE
200AMP METER COMBO
Residential Optional Calculation 9/25/1997 OPTIONAL
by: John Sokolik Version 2011 L
STEP 1 Article 220.82 (B) (1),(2)SOUTHERN SHORES ELECTRIC CO standard
2301 General Lighting load 6,903 VA 1331 NE SUNRISE TER ahu
2 Small Appliance 3,000 VA JENSEN BEACH, FL, 34957 cool
1 Laundry circuit 1,500 VA (772)-353-0072
Gen.Lgt, Sm App.& Laun. Load 11,403 VA 11/12/2021 18:41 ahu
hp
STEP 2 Article 220.82 (C)General lighting, Sm. Appl. & Laundry 11,403 VA
A/C Condenser & Fixed Electric Space Heating Total 1 ###
7,130 VA AHU 1 11,600 VA Heating Load 8,100 VA ###
VA AHU 2 VA CU Load 8,730 VA ###
VA AHU 3 VA ###
VA AHU 4 VA Electric Space Heat @ 65% <4, 40% >3, vs. A/C @ 100%8,730 VA ###
VA AHU 5 VA ###
STEP 3 Article 220.82 (B) (3)Appliance Demand Load 15,944 VA ###
1 Water Heater 4,500 VA ###
1 Refrigerator 1,400 VA Dryer Demand Load 7,200 VA
0 Freezer VA DEM FACTOR
1 Dishwasher 1,400 VA Range Demand Load 8,000 VA ###
1 Disposal 690 VA <4
1 R / Hood 400 VA Service Demand 31,749 VA >3
1 Microwave 1,700 VA
0 Microwave VA Demand Load 132 A
0 Mini Refrig VA
0 Wine Clr VA Neutral Demand 87 A
0 Insta Hot VA
0 Ironing Center VA Min.Service Req.150 A
Jacuzzi Tub VA
Sprinkler Pump 1,127 VA Min. Feeder size 1
Well Pump 1,127 VA Min. Neutral size 3
Fountain Pump VA Eq. Grding Cond.6
Elevator VA Copper
Pool Equip. Panel VA Apply Demand
3600 POOL PUMP 3,600 VA No Demand
VA No Demand Total Appliance Load 15,944 VA
STEP 4 Article 220.82 (B) (3)
Electric Clothes Dryers 7,200 VA
STEP 5 Article 220.82 (B) (3)
Electric Ranges 8,000 W Col C demand 8000
Cooktop Col B demand
Cooktop Col B demand
Oven(s) Col B demand
Oven(s) Col B demand
Number of appliances 0 Dem. Factor
Cooktop & Oven Demand Load
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>><<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<
Pool Panel Feeder Calculation (See Note)A B N Continuous Non-continuous
Continuous Motors 0 . . . . . .0 0 0 Motors Motors
Non-continuous 0 . . . . . .0 0 0 240v 240v
Spa heater 11 kVA . . . . . .0 0 240v 240v
Pool heater 3.5 ton . . . . . .0 0 240v 240v
Pool heater 5 ton . . . . . .0 0 240v 240v
Pool Light 0 . . . . . .0 0 0 240v 240v
Blower 2333 0 240v 0 0 0
other load 0 240v 0 0 0 0.0 Motor Neutral Load
other load 0 240v 0 0 0
Min.Copper Pool Feeder AWG A A A Max.Unbalanced Neutral Load
Minimum Panel Rating A Phase Amperes Neut. load
QTY
or Number of appliances
jmp1jds@comcast.net
Check Box for Gas Range