HomeMy WebLinkAboutMobile Home Permit WorksheetMobile Home Permit Worksheet
Installer: EDDIE GRUNDEL License # IH1118467
Address of home 234 NETTLES BLVD
being installed
Manufacturer JACOBSEN Length x width
NOTE: if home is a single wide fill out one half of the blocking plan
if home is a triple or quad wide sketch in remainder of home
I understand Lateral Arm Systems cannot be used on any home (new or used)
where the sidewall ties exceed 5 ft 4 in.
Installer's initials EG
Typical pier spacing
6' I lateral
Show locations of Longitudinal and Lateral Systems
bngitudinal (use dark lines to show these locations)
I
- -.....
-------
---
-- --- -----
--- ----1-4
7
-
-----------------
-=
Li
Li
L_j
Li
Li
marriage
Li
wall piers
within 2' of
Li
end
of home per
Li
Rule
15C
Application Number:
New Home
O✓ Used Home
Date:
Home installed to the Manufacturer's Installation Manual
Home is installed in accordance with Rule 15-C
H
Single wide ❑ Wind Zone II ❑ Wind Zone III
Q✓
Double wide 0✓ Installation Decal # TBD
to c,
r
C--
Triple/Quad ❑ Serial # TBD
3 ® t�
c
dM
PIER SPACING TABLE FOR USED HOMES
Load
bearing
capacity
Footer
size
(sq in)
16" x 16"
(256 )
18 1 /2" x 18
1/2"342 ( )
20" x 20"
400
( )
22" x 22"
(484)*
24" X 24"
(576)*
26" x 26"
(676)
000 psf
3'
4'
S7
6
7'
8'
500 psf
4' 6"
6
7'
8
8'
2000 sf
6'
8
8
8
8
8'
2500 psf
7
8'
3000 ps
8'
8
8'
8'
3500 sf
8'
8
8'
8
8'
lntefpoiatea trom Kule i au-i pier spacing taole.
PIER PAD SIZES
I-beam pier pad size 17X22.5
Perimeter pier pad size 16X16
Other pier pad sizes
(required by the mfg.)
Draw the approximate locations of marriage
wall openings 4 foot or greater. Use this
symbol to show the piers.
List all marriage wall openings greater than 4 foot
and their pier pad sizes below.
Opening
1-4
2-3,
POPULAR PAD SIZES
Pad ize
so In
iri x
6 x 18
288
5 x 18.5
342
6 x 22.5
36
7 x
74
3 1 4 x 2 4
348
20 x 0
400
17 3/ 6 x 25 3/16
44
712x2512
44
24 x 24
576
26 x 26
76
ANCHORS
4ft _V(_5ft_
FRAME TIES
within 2' of end of hc--
spaced at 5' 4" oc _ _
TIEDOWN COMPONENTS OTHER TIES
Number
Longitudinal Stabilizing Device (LSD) Sidewall
Manufacturer _OLIVER Longitudinal
Longitudinal Stabilizing Device w/ Lateral Arms Marriage wall
Manufacturer Shearwall
Page 1 of 2
Pier pad size
17X22.5
23X31
Mobile Home Permit Worksheet Application Number:
Date:
POCKET PENETROMETER TEST
The pocket penetrometer tests are rounded down to 1500 psf
or check here to declare 1000 lb. soil without testing.
X 1,500 X 1,500 X 1,500
POCKET PENETROMETER TESTING METHOD
1. Test the perimeter of the home at 6 locations.
2. Take the reading at the depth of the footer.
3. Using 500 lb. increments, take the lowest
reading and round down to that increment.
X 1,500 X 1,500 X 1,500
TORQUE PROBE TEST
The results of the torque probe test is 290 inch pounds or check
here if you are declaring 5' anchors without testing . A test
showing 275 inch pounds or less will require 5 foot anchors.
Note: A state approved lateral arm system is being used and 4 ft.
anchors are allowed at the sidewall locations. I understand 5 ft
anchors are required at all centerline tie points where the torque test
reading is 275 or less and where the mobile home manufacturer may
requires anchors with 4000 lb holding capacity.
Installer's initials
ALL TESTS MUST BE PERFORMED BY A LICENSED INSTALLER
Installer Name EDDIE GRUNDEL
Date Tested
Electrical
Connect electrical conductors between multi -wide units, but not to the main power
source. This includes the bonding wire between mult-wide units. Pg.
Plumbina
Connect all sewer drains to an existing sewer tap or septic tank. Pg.
Site Preparation
Debris and organic material removed X
Water drainage: Natural Swale Pad X Other
Fastening multi wide units
Floor: Type Fastener: LAG Length: 6" Spacing: 24"
Walls: Type Fastener: LAG Length: 6" Spacing: 24"
Roof: Type Fastener: GALV Length: CONT Spacing: 24"
For used homes a min. 30 gauge, 8" wide, galvanized metal strip
will be centered over the peak of the roof and fastened with galv.
roofing nails at 2" on center on both sides of the centerline.
Gasket (weatherproofing requirement)
I understand a properly installed gasket is a requirement of all new and used
homes and that condensation, mold, meldew and buckled marriage walls are
a result of a poorly installed or no gasket being installed. I understand a strip
of tape will not serve as a gasket.
Installer's initials
Type gasket FACTORY FOAM
Pg.
Installed:
Between Floors Yes X
Between Walls Yes X
Bottom of ridgebeam Yes X
Weatherproofing
The bottomboard will be repaired and/or taped. Yes X . Pg.
Siding on units is installed to manufacturer's specifications. Yes X
Fireplace chimney installed so as not to allow intrusion of rain water. Yes X
Miscellaneous
Skirting to be installed. Yes X No
Dryer vent installed outside of skirting. Yes X N/A
Range downflow vent installed outside of skirting. Yes X N/A
Drain lines supported at 4 foot intervals. Yes X
Electrical crossovers protected. Yes X
Other:
Installer verifies all information given with this permit worksheet
is accurate and true based on the
manufacturer's installation instructions and or Rule 1SC-1 8r 2
Connect all potable water supply piping to an existing water meter, water tap, or other Installer Signature
independent water supply systems. Pg.
Date
Page 2 of 2