Loading...
HomeMy WebLinkAboutAPPROVED, 457182 Permit Package - Sealed and Certified(UPDATED)Structural Design Report 150' Monopole Site: Ft. Pierce, FL Site Number: PIFL067 Prepared for: PI TELECOM INFRASTRUCTURE, LLC by: Sabre Industries TM Job Number: 457182 October 7, 2021 Monopole Profile……………………………………………………………………………………….1 Foundation Design Summary……………………………………………………………………………………….2 Pole Calculations……………………………………………………………………………………….3-13 Foundation Calculations……………………………………………………………………………………….14-21  Page 1 1) 2) 3) 4) 5) 6) 7) 8) Information contained herein is the sole property of Sabre Towers & Poles, constitutes a trade secret as defined by Iowa Code Ch. 550 and shall not be reproduced, copied or used in whole or part for any purpose whatsoever without the prior written consent of Sabre Towers & Poles. 7101 Southbridge Drive - P.O. Box 658 - Sioux City, IA 51102-0658 - Phone 712.258.6690 - Fax 712.279.0814 The foundation design is based on the geotechnical report by ECA Project No. T1542b, Date: 05/08/19 Concrete shall have a minimum 28-day compressive strength of 4,500 psi, in accordance with ACI 318-14. All rebar to have a minimum of 3” concrete cover. All exposed concrete corners to be chamfered 3/4”. Notes: See the geotechnical report for drilled pier installation requirements, if specified. Rebar to conform to ASTM specification A615 Grade 60. Pier (76) #11 vertical rebar w/ #5 ties, (2) within top 5” of pier, then 6” C/C 8'-0" long anchor bolts are required. No.: 457182 Date: 10/07/21 By: DO Rebar Schedule for Pier Customer: PI TELECOM INFRASTRUCTURE, LLC Site: Ft. Pierce, FL PIFL067 150’ Monopole The bottom anchor bolt template shall be positioned as closely as possible to the bottom of the anchor bolts. Grade ELEVATION VIEW (76.58 Cu. Yds.) (1 REQUIRED; NOT TO SCALE)32'-6"0'-6"32'-0"9'-0" Dia. Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 SO#: Site Name: Date: 10/7/2021 Diameter: 68.770 in (flat to flat) Thickness: 0.625 in Yield (Fy): 65 ksi # of Sides: 18 "0" IF Round Strength (Fu): 80 ksi Anchor Rod Results (per 4.9.9) Moment, Mu: 12935.32 ft-kips Stiffened Axial, Pu: 87.9 kips Maximum Put: 224.36 Kips AISC LRFD Shear, Vu: 109.04 kips t*Rnt: 243.75 Kips Butt Vu: 3.03 Kips v*Rnv: 149.10 Kips Tension Interaction Ratio: 0.85 Quantity: 36 (multiple of 4) Maximum Puc: 228.63 Kips Diameter: 2.25 in c*Rnc: 243.75 Kips Rod Material: A615 Vu: 3.03 Kips Strength (Fu): 100 ksi c*Rnvc: 73.13 Kips Yield (Fy): 75 ksi Compression Interaction Ratio:0.94 BC Diam. (in): 76.25 BC Override: Maximum Interaction Ratio:94.0% Rod Spacing: 6 in Base Plate Results Base Plate (Mu/Z): 43.9 ksi Width (in): 81 Width Override: Allowable *Fy: 45 ksi (per AISC) Thickness: 2.5 in Base Plate Interaction Ratio:97.6% Yield (Fy) 50 ksi Yield Line (in): Eff. Width: 45.78 in 45.78129855 Corner Clip 23.00 in Max PL Length: Drain Hole: 2.625 in. diameter 45.78129855 Drain Location: 32 in. center of pole to center of drain hole Center Hole: 56 in. diameter Square Base Plate and Anchor Rods per ANSI/TIA 222-H Reactions Anchor Rod Data 457182 Ft. Pierce, FL Pole Data Plate Data Page 13 Page 14 Page 15 Page 16 Page 17 Page 18 Page 19 Page 20 1807.3.2.1 (2009 IBC, 2012 IBC, & 2015 IBC) Moment (ft k)12,935.32 Shear (k) 109.04 Caisson diameter (ft) 9 Caisson height above ground (ft) 0.5 Caisson height below ground (ft) 32 Lateral soil pressure (lb/ft2)450.00 Ground to application of force, h (ft) 119.13 Applied lateral force, P (lb) 109,040 Lateral soil bearing pressure, S1 (lb/ft)4,800.00 Diameter, b (ft) 9 A 5.91 = (2.34P )/(S 1 b ) Minimum depth of embedment, d (ft) 30.80 = 0.5A [ 1 + ( 1 + ( 4.36h / A ) )1/2 ] Page 21