Loading...
HomeMy WebLinkAboutMobile Home Inspection Reportf �L St Lucie County Building & Zoning 2300 Virginia Avenue Ft Pierce, FL 34982 Rr F- PERMIT # a t aa- a0s8 Mobile Home Inspection Report All requests for permits to place or replace used Mobile / Manufactured homes must be accompanied by this completed Inspection Report and copies of both sides of the Title to the home. All used Mobile homes must be Wind Zone 11 certified. Owner: %t %1 c. Avv> Rwa Date: 3 (Print or type) , Address: Year / Manufacturer "a137SoG _ I Serial #aAAA A-C)0411 HUD Plate # 66D l 'l03 r#7 Width Length � Single �� Double Wind Zone C = In Compliance N = Not in Compliance R : R E PAI RA I-C Fire Safety / Electrical _ 1. Smoke Detector: Installed Missing 2. Electrical System Checked: Exposed Wiring Other 3. Distribution Panel: Missing Loose Main Missing Breaker Missing Unplugged Opening Other JS, 4. Electrical Fixtures: Missing Installed Improperly . Improperly Wired Loose Wire GFCI receptacles not where required C_ 5. Electrical Ground: Chassis Main Panel Gas Pipe Revised 3/9/05 Page 1 of 3 110 coo ov Construction 1. Exit Doors Operable: Front Back Other C 2. Exit Door Locks: Missing Inoperable C 3. Egress windows: Missing Inoperable �i 4. Windows: Broken Glass Inoperable �L 5. Screens: Missing Damaged 6. Floor System: Joist Decking Area Damaged _ 7. Interior Paneling: Missing Loose Damaged 8. Rodent Proofing: Bottom Board Pipe openings Other C 9. Leaks Apparent: Ceiling Doors Floor Roof _ 10. Vertical tie -down straps: Missing Short Damaged 11. Structural modifications since manufactured: YES_ NO ✓ I N7_ WAU5 HAVE 12. Walls: Structurally Unsound Loose Weather tight V= RTI CAL SIRE 5 5 CRACK -Se WINDOWS AND Plumbing POOR FROM TRAY5IoP - G 1. Trap: Missing Not connected Other TION C 2. Plumbing fixtures: Missing Not installed Not Vented --C,_ 3. Relief Valve: Missing Inoperable Other 4. Drain Waste and Venting Piping: Missing Not supported. Clean outs Use of fittings Not capped Heating and Air Conditioning __C_ 1. Heating Appliances: Missing Not Connected _X,_ 2. Deleted Heating/AC system: Not installed Other, 6_ 3. Thermostat: Missing Inoperable G 4. Air registers: Miss Inoperable —jr4-_ 5. Ducts: Not sealed Missing Collapsed Page 2 of 3 Other 6. Gas furnace Water heater vent: Missing Loose _6 7. Return Air: To Furnace To A/C From rooms _jC,_ 8. Range: Vent Hood 0 9. Gas Valve: Accessible Installed improperly 10. Gas lines: Not capped Not supported Kinked Not bonded Summary 1. Is subject structure found to be fifty (50%) or more damaged or deteriorated? YES NOZ 2. Will a remodeling permit be required? YES NO_V_" The provisions of the repair and remodeling code shall ensure safe and livable housing and shall not be more stringent than those standards required to be met in the manufacture of mobile homes. Such provisions shall include, but not be limited to, standards for structural adequacy, plumbing, heating, electrical systems, and fire and life safety. FS 320.8232 IF ANY RENOVATIONS OR IMPROVEMENTS OVER AND ABOVE THE REQUIREMENTS OF FS 320.8232 ARE TO BE PERFORMED ON ANY MOBILE HOME WHICH WILL BE PERMITTED TO BE TIED -DOWN IN ST. LUCIE COUNTY, A SEPARATE PERMIT WITH ENGINEERING (IF APPLICABLE) WILL BE REQUIRED. ALL SEPARATE PERMITS MUST OBTAIN A FINAL INSPECTION BEFORE A FINAL INSPECTION IS OBTAINED FOR THE TIE -DOWN PERMIT. NO MOBILE HOME WILL BE ALLOWED TO BE MOVED TO ST. LUCIE COUNTY OR RE- LOCATED WITHIN ST. LUCIE COUNTY UNTIL THE REQUIRED DOCUMENTS HAVE BEEN SUBMITTED, REVIEWED, APPROVED AND THE TIE -DOWN PERMIT HAS BEEN ISSUED. A REGISTERED FLORIDA PROFESSIONAL ENGINEER MUST COMPLETE THIS DOCUMENT, SIGN AND AFFIX THEIR SEAL. Date inspected: .13 1/9 Inspected By: 'V J I. �� License # ✓ 6 3 J b Slgn ture required �J/ 3 Iginielers Phone Number: ( 1� E Seal Page 3 of 3 STEVEN G. WOOD, P.E. IE"IL II&C1ENSE 34,9096 960 21ULTAN DR FORT ST LUCIE, FIL