Loading...
HomeMy WebLinkAboutEnergy Efficiency Code 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 712/14/2021 2:11 PM Project Name: Owner: Builder Name: Permit Office: Jurisdiction: St. Lucie County St. Lucie County Lippard Construction Sofen Residence Sofen Residence Street: City, State, Zip: Fort Pierce , FL , 34949 1812 Wildcat Cove Drive Permit Number:20110-0570 Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft²) New (From Plans) Detached 1 No 2690 7. Windows a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : Sgl, U=0.65 227.00 ft² SHGC=0.28 Sgl, U=0.65 154.50 ft² SHGC=0.30 Sgl, U=0.65 52.50 ft² SHGC=0.25 9. Floor Types a. Slab-On-Grade Edge Insulation b. N/A c. N/A R=0.0 2690.00 ft² R=f t ² R=f t ² 10. Wall Types a. Concrete Block - Ext Insul, Exterior R=4.0 1850.00 ft² b. Frame - Wood, Adjacent R=13.0 590.00 ft² c. Concrete Block - Int Insul, Exterior R=4.1 210.00 ft² 11. Ceiling Types a. Roof Deck (Unvented)R=20.0 2690.00 ft² f t ² R=b. N/A c. N/A R = f t ² 12. Ducts a. Sup: Attic, Ret: Attic, AH: Garage 13. Cooling systems 14. Heating systems 15. Hot water systems a. Electric Cap: 50 gallons b. Conservation features None d. N/A R=f t ² Area Weighted Average Overhang Depth:5.318 ft. Area Weighted Average SHGC:0.282 Description Area Insulation Area Insulation Area Insulation Area 16. Credits CF, Pstat 3 (446.0 sqft.) (2650.0 sqft.) (2690.0 sqft.) (2690.0 sqft.) Conditioned floor area below grade (ft²) 0 a. Central Unit a. Electric Strip Heat k B t u / h r 46.0 SEER:17.00 Efficiency k B t u / h r Efficiency 34.0 COP:1.00 f t ² R 6 80 EF: 0.950 8. Skylights c. U-Factor:(AVG) S H G C ( A V G ) : N/A N/A f t ² Area Glass/Floor Area: 0.166 Total Proposed Modified Loads: Total Baseline Loads: 80.11 80.09 PASS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: BUILDING OFFICIAL: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method FORM R405-2020 12-14-2021 PROJECT Title: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: St. Lucie County St. Lucie County Lippard Construction 1 Sofen Residence Sofen Residence Family Type: New/Existing: Bedrooms: Conditioned Area: Total Stories: Worst Case: Rotate Angle: 0 No 1 2690 3 New (From Plans) Detached Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: FL , 34949 Fort Pierce , St. Lucie 1812 Wildcat Cove Driv Street Address Comment: Building Type: User Cross Ventilation: No Whole House Fan: No TMY Site Design Temp Int Design Temp Heating Design Daily Temp Design Location 2.5 %97.5 % Degree Days Moisture RangeWinter Summer CLIMATE 90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______ Number Name Area Volume BLOCKS 1 Entire House 2690 26900 Number Name Area Volume SPACES Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished 1 Living Room 420 4200 No 2 Yes Yes1 Yes 2 Bath 1 118 1180 No 0 Yes Yes1 Yes 3 Bath 4 36 360 No 0 Yes Yes1 No 4 Toilet 1 24 240 No 0 Yes Yes1 Yes 5 Toilet 2 24 240 No 0 Yes Yes1 No 6 Bedroom 1 312 3120 No 2 1 Yes Yes1 Yes 7 WIC 1 48 480 No 0 Yes Yes1 No 8 WIC 2 48 480 No 0 Yes Yes1 No 9 Hall 1 345 3450 No 0 Yes Yes1 Yes 10 Bedroom 3 252 2520 No 1 1 Yes Yes1 Yes 11 Bath 3 60 600 No 1 Yes Yes1 Yes 12 Bath 2 60 600 No 1 Yes Yes1 Yes 13 Bedroom 2 239 2390 No 2 1 Yes Yes1 Yes 14 Hall 2 48 480 No 0 Yes Yes1 No 15 Laundry 81 810 No 0 Yes Yes1 Yes 16 Kitchen 380 3800 Yes 2 Yes Yes1 Yes 17 Dining 195 1950 No 1 Yes Yes1 Yes 12/14/2021 2:11 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 1 420 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -41 ft Living Room 2 118 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -6 ft Bath 1 3 36 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -1 ft Bath 4 4 24 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -4 ft Toilet 1 5 24 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -1 ft Toilet 2 6 312 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -20 ft Bedroom 1 7 48 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -1 ft WIC 1 8 48 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -1 ft WIC 2 9 345 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -9 ft Hall 1 10 252 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -18 ft Bedroom 3 11 60 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -6 ft Bath 3 12 60 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -6 ft Bath 2 13 239 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -18 ft Bedroom 2 14 48 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -1 ft Hall 2 15 81 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -9 ft Laundry 16 380 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -26 ft Kitchen 17 195 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -43 ft Dining # Type Materials Color Absor. Roof Solar Deck Insul. Pitch ROOF Tested Roof Area Gable Area Emitt Tested EmittSA (deg) Rad Barr 1 Hip Barrel tile 3008 ft² Medium 0.6 20 26.57______ No0 ft² 0.9 NoN ATTIC # Type Ventilation Area RBS IRCCVent Ratio (1 in) ______ 1 Full attic Unvented 2690 ft² N N0 12/14/2021 2:11 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT # Ceiling Type R-Value Area Framing Frac Truss Type CEILING Space Ins Type 1 Under Attic (Unvented) 0 420 ft² 0.1 Wood______ Living Room Blown 2 Under Attic (Unvented) 0 118 ft² 0.1 Wood______ Bath 1 Blown 3 Under Attic (Unvented) 0 36 ft² 0.1 Wood______ Bath 4 Blown 4 Under Attic (Unvented) 0 24 ft² 0.1 Wood______ Toilet 1 Blown 5 Under Attic (Unvented) 0 24 ft² 0.1 Wood______ Toilet 2 Blown 6 Under Attic (Unvented) 0 312 ft² 0.1 Wood______ Bedroom 1 Blown 7 Under Attic (Unvented) 0 48 ft² 0.1 Wood______ WIC 1 Blown 8 Under Attic (Unvented) 0 48 ft² 0.1 Wood______ WIC 2 Blown 9 Under Attic (Unvented) 0 345 ft² 0.1 Wood______ Hall 1 Blown 10 Under Attic (Unvented) 0 252 ft² 0.1 Wood______ Bedroom 3 Blown 11 Under Attic (Unvented) 0 60 ft² 0.1 Wood______ Bath 3 Blown 12 Under Attic (Unvented) 0 60 ft² 0.1 Wood______ Bath 2 Blown 13 Under Attic (Unvented) 0 239 ft² 0.1 Wood______ Bedroom 2 Blown 14 Under Attic (Unvented) 0 48 ft² 0.1 Wood______ Hall 2 Blown 15 Under Attic (Unvented) 0 81 ft² 0.1 Wood______ Laundry Blown 16 Under Attic (Unvented) 0 380 ft² 0.1 Wood______ Kitchen Blown 17 Under Attic (Unvented) 0 195 ft² 0.1 Wood______ Dining Blown WALLS # Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 1 4.1 0Living Room 00021 10SE Concrete Block - Int Insul 0.350Exterior 210.0 ft² ____ 2 4 0Living Room 00020 10SW Concrete Block - Ext Insul 0.350Exterior 200.0 ft² ____ 3 4 0Bath 1 0006 10SW Concrete Block - Ext Insul 0.350Exterior 60.0 ft² ____ 4 4 0Toilet 1 0004 10SW Concrete Block - Ext Insul 0.350Exterior 40.0 ft² ____ 5 4 0Bedroom 1 00020 10SW Concrete Block - Ext Insul 0.350Exterior 200.0 ft² ____ 6 4 0Hall 1 0003 10SW Concrete Block - Ext Insul 0.350Exterior 30.0 ft² ____ 7 4 0Hall 1 0006 10NW Concrete Block - Ext Insul 0.350Exterior 60.0 ft² ____ 8 4 0Bedroom 3 00018 10NE Concrete Block - Ext Insul 0.350Exterior 180.0 ft² ____ 9 4 0Bath 3 0006 10NE Concrete Block - Ext Insul 0.350Exterior 60.0 ft² ____ 10 4 0Bath 2 0006 10NE Concrete Block - Ext Insul 0.350Exterior 60.0 ft² ____ 11 4 0Bedroom 2 00018 10NE Concrete Block - Ext Insul 0.350Exterior 180.0 ft² ____ 12 4 0Laundry 0009 10NE Concrete Block - Ext Insul 0.350Exterior 90.0 ft² ____ 13 4 0Kitchen 00020 10NE Concrete Block - Ext Insul 0.350Exterior 200.0 ft² ____ 14 4 0Kitchen 0006 10SE Concrete Block - Ext Insul 0.350Exterior 60.0 ft² ____ 15 4 0Dining 00015 10NE Concrete Block - Ext Insul 0.350Exterior 150.0 ft² ____ 16 4 0Dining 00013 10SE Concrete Block - Ext Insul 0.350Exterior 130.0 ft² ____ 17 4 0Dining 00015 10SW Concrete Block - Ext Insul 0.350Exterior 150.0 ft² ____ 18 13 0Bedroom 1 15 10NW Frame - Wood 0.350.23Garage 150.0 ft² ____ 19 13 0WIC 2 6 10NW Frame - Wood 0.350.23Garage 60.0 ft² ____ 20 13 0Hall 1 25 10NE Frame - Wood 0.350.23Garage 250.0 ft² ____ 21 13 0Hall 1 4 10NW Frame - Wood 0.350.23Garage 40.0 ft² ____ 22 13 0Laundry 9 10NW Frame - Wood 0.350.23Garage 90.0 ft² ____ 12/14/2021 2:11 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT # Door Type U-Value AreaStorms DOORS Ornt Space Width Ft In Ft In Height 1 Insulated .39 21.3 ft² None______ NW Hall 1 882 2 Insulated .39 21.3 ft² None______ NE Hall 1 882 # Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening WINDOWS Overhang Orientation shown is the entered, Proposed orientation. Wall ID Imp 1 SE Low-E Single 0.65 0.3 77.3 ft² 13 ft 0 in 1 ft 4 in NoneMetal None______ Yes1 Y 2 SW Low-E Single 0.65 0.28 36.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______ Yes2 Y 3 SW Low-E Single 0.65 0.28 8.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______ Yes3 Y 4 SW Low-E Single 0.65 0.28 30.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______ Yes5 Y 5 NW Low-E Single 0.65 0.28 24.0 ft² 4 ft 0 in 1 ft 4 in NoneMetal None______ Yes7 Y 6 NE Low-E Single 0.65 0.28 30.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______ Yes8 Y 7 NE Low-E Single 0.65 0.25 6.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______ Yes9 Y 8 NE Low-E Single 0.65 0.25 6.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______ Yes10 Y 9 NE Low-E Single 0.65 0.28 30.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______ Yes11 Y 10 NE Low-E Single 0.65 0.28 15.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______ Yes12 Y 11 NE Low-E Single 0.65 0.22 12.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______ Yes13 Y 12 SE Low-E Single 0.65 0.28 54.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______ Yes16 Y 13 SW Low-E Single 0.65 0.25 40.5 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______ Yes17 Y 14 SE Low-E Single 0.65 0.3 77.3 ft² 13 ft 0 in 1 ft 4 in NoneMetal None______ Yes1 Y # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation GARAGE 1 1530 ft² 1530 ft² 58 ft 8 ft 13______ Method CFM 50 ACH 50ELASLAScope INFILTRATION ACHEqLA# 2241.7 5122.98.000317Wholehouse .0987230.89Proposed ACH(50)1 HEATING SYSTEM # System Type Efficiency Capacity DuctsSubtype BlockSpeed 1 Electric Strip Heat/ COP:1 34 kBtu/hr ______ sys#1None 1 # System Type Efficiency Capacity Air Flow SHR COOLING SYSTEM DuctsSubtype BlockSubtype 1 Central Unit/ SEER: 17 46 kBtu/hr c f m 0.7______ sys#1Split 1 Singl 12/14/2021 2:11 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT # System Type EF Cap Use SetPnt Conservation HOT WATER SYSTEM SubType Location 1 Electric 0.95 50 gal 60.9 gal 120 deg None______ None Garage FSEC Company Name System Model # Collector Model # Collector SOLAR HOT WATER SYSTEM Storage FEFCert # Area Volume None None f t ² ______ # Location R-Value Area Location Area ---- Supply ---- ---- Return ---- Leakage Type Handler CFM 25Air QN RLF DUCTS Heat Cool HVAC # TOT OUT CFM25 1 Attic 6 80 ft² Attic 20 ft² Default Leakage Garage ( D e f a u l t ) ______ 1 1 ( D e f a u l t ) TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec [ ] Dec[X] Dec[X] Nov[X] Nov[ ] Oct[X] Oct[ ] Sep[ ] Sep[ ] Aug[ ] Aug[ ] Jul[ ] Jul[ ] Jun[ ] Jun[X] Jun[ ] May[ ] May[ ] Apr[X] Apr[X] Mar[X] Mar[X] Feb[ ] Feb[X] Jan[ ] JanHeatingVenting Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AMPM 7880 7880 7878 7878 7878 7878 7878 7878 8078 8078 8078 8078 Cooling (WEH) AMPM 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 Heating (WD) AMPM 6668 6668 6668 6668 6668 6868 6868 6868 6868 6868 6866 6866 Heating (WEH) AMPM 6668 6668 6668 6668 6668 6868 6868 6868 6868 6868 6866 6866 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft² 0 ft 0.3 Living Room Default(8 lbs/sq.ft. f t ² f t 0.3 Bath 1 Default(8 lbs/sq.ft. f t ² f t 0.3 Bath 4 Default(8 lbs/sq.ft. f t ² f t 0.3 Toilet 1 Default(8 lbs/sq.ft. f t ² f t 0.3 Toilet 2 Default(8 lbs/sq.ft. f t ² f t 0.3 Bedroom 1 Default(8 lbs/sq.ft. f t ² f t 0.3 WIC 1 Default(8 lbs/sq.ft. f t ² f t 0.3 WIC 2 Default(8 lbs/sq.ft. f t ² f t 0.3 Hall 1 Default(8 lbs/sq.ft. f t ² f t 0.3 Bedroom 3 Default(8 lbs/sq.ft. f t ² f t 0.3 Bath 3 Default(8 lbs/sq.ft. f t ² f t 0.3 Bath 2 Default(8 lbs/sq.ft. f t ² f t 0.3 Bedroom 2 Default(8 lbs/sq.ft. f t ² f t 0.3 Hall 2 Default(8 lbs/sq.ft. f t ² f t 0.3 Laundry Default(8 lbs/sq.ft. f t ² f t 0.3 Kitchen 12/14/2021 2:11 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. f t ² f t 0.3 Dining 12/14/2021 2:11 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 7 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT Project Name: Owner: Builder Name: Permit Office: Jurisdiction: St. Lucie County St. Lucie County Lippard Construction Sofen Residence Sofen Residence Street: City, State, Zip: Fort Pierce , FL , 34949 1812 Wildcat Cove Drive Permit Number:20110-0570 Design Location: FL, Fort Pierce CHECKAIR BARRIER CRITERIA A continuous air barrier shall be installed in the building envelope. The exterior thermal envelope contains a continuous air barrier. Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. The junction of the foundation and sill plate shall be sealed. The junction of the top plate and the top of exterior walls shall be sealed. Knee walls shall be sealed. The space between window/door jambs and framing, and skylights and framing shall be sealed. Rim joists shall include the air barrier. The air barrier shall be installed at any exposed edge of insulation. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Narrow cavities Shafts, penetrations Crawl space walls Floors (including above-garage and cantilevered floors) Rim joists Windows, skylights Walls Ceiling/attic General COMPONENT Garage separation Recessed lighting Plumbing and wiring S h o w e r / t u b HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub-floor, wall covering or The air barrier shall be installed behind electrical or communication boxes or air-sealed boxes shall be installed. The air barrier installed at exterior walls adjacent to showers and tubs shall separate them from the showers and tubs. Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Recessed light fixtures installed in the building thermal envelope shall be sealed to the finished surface. Air sealing shall be provided between the garage and conditioned spaces. When required to be sealed, concealed fire sprinklers shall only be sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. C o n c e a l e d Electrical/phone box on exterior walls Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA INSULATION INSTALLATION CRITERIA EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software12/14/2021 2:12 PM Page 1 of 1 Air-permeable insulation shall not be used as a sealing material. The insulation in any dropped ceiling/soffit shall be aligned with the air barrier. Cavities within corners and headers of frame walls shall be insulated by completely filling the cavity with a material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Rim joists shall be insulated. Floor framing cavity insulation shall be installed to maintain permanent contact with the underside of subfloor decking, or floor framing cavity insulation shall be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. and doors on exterior wall requirements Recessed light fixtures installed in the building thermal envelope shall be air tight and IC rated. sprinklers Where provided instead of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exterior walls adjacent to showers and tubs shall be insulated. 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. a 1812 Wildcat Cove Drive, Fort Pierce, FL, 34949 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft²) New (From Plans) Detached 1 3 No 2690 7. Windows** a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : d. U-Factor: S H G C : Sgl, U=0.65 227.00 ft² SHGC=0.28 Sgl, U=0.65 154.50 ft² SHGC=0.30 Sgl, U=0.65 52.50 ft² SHGC=0.25 other (see details) 12.00 ft² other (see details) 9. Floor Types a. Slab-On-Grade Edge Insulation b. N/A c. N/A R=0.0 2690.00 ft² R= f t ² R= f t ² 10. Wall Type and Insulation a. Concrete Block - Ext Insul, Exterior R=4.0 1850.00 ft² b. Frame - Wood, Adjacent R=13.0 590.00 ft² c. Concrete Block - Int Insul, Exterior R=4.1 210.00 ft² 11. Ceiling Type and insulation level a. Roof Deck (Unvented) R=20.0 2690.00 ft² f t ² R=b. N/A c. N/A R = f t ² 12. Ducts, location & insulation level 13. Cooling systems 14. Heating systems k B t u / h r 15. Hot water systems a. Electric Cap: 50 gallons EF: 0.95 b. Conservation features None d. N/A R= f t ² Description Area Insulation Area Insulation Area Insulation Area Credits (Performance method) CF, Pstat Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 5.318 ft. 0.282 a. Electric Strip Heat 34.0 COP:1.00 a. Central Unit 46.0 SEER:17.00 k B t u / h r Efficiency Efficiency a. Sup: Attic, Ret: Attic, AH: Garage 6 80 R f t ² 8. Skylights a. U-Factor(AVG): S H G C ( A V G ) : Description Area N/A N/A f t ² I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature:Date: Address of New Home:City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. Page 1 of 1 FORM R405-2020 12/14/2021 2:12 PM