Loading...
HomeMy WebLinkAboutROOFING PERMIT INFORMATION SHEET-- ---M� - -•- ---+- _._., -- a7 _ r ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code - Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Low Slope Application Prescriptive BUR-RAS 150 Asphaltic Shingles + Concrete or Clay Tile Metal Roofs I Wood Shingles and Shakes Other Required Sections of the Permit Application Form A,B,C A,B,C A, B, D A, B, D, E A,B,D A,B,D As Applicable Attachments Required See List Below 1,2,3,4,5,6,7 2,4,5,6,7 1,2,4,5,6,7 1,2,3,4,5,6,7 1,2,4,5,6,7� 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED As Applicable]: 1. Fire Directory Listing Page I From Product Approval: Front Page Specific System description Specific System limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Form RooflnfoFeb21 Rev Feb 19, 2021 ST. LUCIE . Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: Product Approval No.: Design Wind Pressures, From RAS 128 Or Calculations: Zone 1': _ Zone 1: _ Zone 2: _Zone 3: _ Max. Design Pressure, from the specific product approval system: Deck: Type: Gauge Thickness: Slope: Anchor/Base Sheet & No. df Ply(s): Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer: Base Insultation Size and Thickness: Base Insulation Fastener/Bonding Material: Top Insulation Layer: Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): Base Sheet Fastener/Bonding Material: Ply Sheet(s)' & No. of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: Top Ply Fastener/Bonding Material: Surfacing: Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1':_." oc @ Lap, # Rows_ ® _' oo . Zone 1:_" oc @ Lap, # Rows _ ®_ oo Zone 2: oc@Lap, # Rows _®_"oo Zone 3:_." oc @ Lap, 7t Rows_ @ _' co Number of Fasteners Per Insulation Board: Zone 1':_Zone 1:_Zone 2:_Zone 3 Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc., Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material'Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS ill and Chapter 16.. ST. LUCIE WORKS Section D (Steep Slope Roof System) Roof system Manufaaurer. JA TAYLOR ROOFING EDGE-LOC 1" STANDING SEAM Notice of Acceptance Number: NOA:18-1023.17 Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): Zone 1: -57 Zone 2e::1QlZone 2n:_Zone 2c-98 Zone 3e:-1 28Zone 31: Deck Type: PLYWOOD Type Undedayment ELF ADHERED UNDERWYMENTTO POLYOLASS MTS FL%5259.1 Roof Slope: S 12 Insulation: Fire Barrier: Ridge Venttlagon? Fastener T a&S Spacin g: P 9 B" FIELD /4" PERIMETER, 8D RINGS INK NAILS Adhesiea Type: Type Cap Sheet----� Mears RooPHelght: t5'FT Roof Covedng: METAL Type $Sim Drip 2"X21/2" Edge: ST. LUCIE 1, CORKS Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values for Mr with the values from Mr. If the Mrvalues are greater than or equal to the Mrvalues, for each area of the roof, then the tile attachment method is acceptable. Method 1'Moment Based Tile Calculations Per RAS 12T _. (Zone 1: xix--=-i-Me: _M,_ product Approval M, -_ _)- (Zone 2e: _x�= Mg: _=Mry_ product Approval Mr (Zone 2n: ._xl.= I_Mill: Mom,_ Product Approval Mr. (Zone 2r: _xl_= _I -Mg: =Mm_ product Approval Mr (Zone 3e: -XX__= W--M,a.- Product Approval Mr (Zone 3r: _x2.^= __Mill: a_ Product Approval M. Method 2 "Simplified Tile Calculations Per Table Below" Required Moment of Resistance (MA From T.hle ael..,., ... - wwwa, ivir__ Mr required Moment Resistance* Mean Roof Height Roof Slope 15' 20' 25' 30' q0 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 *Must he used in ..�. 24.4 _ r. 25.9 27.1 28.2 30.0 __.. _.._._.. .. WhjtoObt�ain Information Description Symbol Where to find Design Pressure Zones 1, 2e, 2n, 2rFrom applicable table in RAS 127 or by an engineering analysis prepared by PE based on AKE 7 Mean Roof Height HJob She Roof Slope BJob Site Aerodynamic Multiplier aProduc[Approval Restoring Moment due to Gravity MrProduct Approval Attachment Resistance Mr Product Approval Required Moment Resistance Mr Calculated Minimum Attae chment Resistanc F' Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval Tile Dimensions L=length W=width Product Approval All calculations must be submitted to the building official at the time of permit application.