HomeMy WebLinkAboutConstruction Planss ( Pool/ Spa)TIMER-2" 'AC-2" MAIN DRAIN-2.5" RETURNS-2.5" ►OOR W/ TEP OUT Head west toward US-1 N/S US Hwy 1 259 ft Turn right onto US-1 N/S US Hwy 1 Pass by Sherwin-Williams Paint Store (on the right in 3.1 mi) 9.8 mi Turn left onto Indrio Rd 1.4 mi Turn right onto Slash Pine 0.6 mi V V ANDERSON RESIDENCE 5284 SLASH PINE TRAIL FORT PIERCE, FL. EXISTING COVERED PORC 574 SQFT TOP AND COAT 1T 7" 4306 SOUTH US 1 FORT PIERCE FL. (772) 465-2700 DRAWN BY: NANCY MCNALLY -------------------------------------------------------------------•------------------------------------------------------------------------------------------------------------------------------------- 50LF DECK O DRAIN CONCRETE POURED PATIO 700 SQFT TOP AND COAT 5' 8" x 8" FOOTER / I \ POOL 20'-0" X 40'-0" T-6" TO 6'-0" DEEP 800 SF 120 LF 27,871 Gallons HYDRA COOL LED COLOR LIGHT POOL EQUIPMENT LIST LIGHT: (2) HYDRA COOL LED COLOR TRANSFORMER: (1) 300 W TRANSFORMER JUNCTION BOX: STANDARD ]BOX 5 HOLE SKIMMER: 2" AUTOMATIC MAIN DRAIN: CHANEL HYDRO JETS: NONE RETURNS: (3) THREE VACUUM: (1) ONE CHLORINATOR: JANDY TRUE CLEAR SALT FILTER: DANDY CS 250 PUMP: 1.5 HP 2-SPEED PUMP HEATER: PRE PLUMB TIMER: STANDARD DECK TYPE: CONCRETE DECK SQFT: 700 SQFT COVERED PORCH AREA: CONCRETE 574 SQFT MATCH POOL FOOTER: 8" X 8" WATER FEATURE: NONE DECK ALARM: POOL GUARD DECK ALARM 50' 2" a w w O N 0 M N_ El DOOR W/ STEP OUT 51211 w 0 Scale: 1/4" = 1 ft REVIEWIE O DE PUI 10-06-2021 STATE OF 4� 0R10P`.•.`�`�. �SStoNALtiNG`�. M. Randall Rodgers, P.E. FL Lic. No. 68212 ONE16 Engineering & Consulting, LLC 1801 Hazelwood Drive Ft. Pierce, FL 34982 PH: (772) 201-1634 —Pool construction complies with FBC 2020, ANSI-7, ANSI-15 —Water Velocity —Max 8ft/sec as per FBC 2020—R4501.6.3 —Pool Barrier to comply with Section R4501.17-71h edition FBC —Skimmers comply with FBC 2020—R4501.21.2 —Soil bearing capacity assumed 2,000psi @95% compaction —Equipment Foundotion 3'x7' cone. slab min 3.5" thick pour in place or approved Hurricane Rated precost equipment pads TY PO( STEEL BELOW THE WATERLINE AND VISUALLY SET APART FROM POOL SWIMOUTS (No SCALE) s O N SOLID GUNITE PRESSURE GAUGES INSTALLED ON FILTER PUMP FOR FINAL INSPECTION Vacwm (M Hg) X 1.13 Feet Of Head w� Pressure (PSI) X 2.31 Feet Of Head Vacuum Head + Pressure Head = Total Dynamic Head HYDRO —STATIC DEVICE INSTALLED IN AREAS THAT EXCEED 1' WATER TABLE IN SHELL TRENCH DRAIN POOL DETAIL (NO SCALD OUTSIDE ANGLE OF REPOSE W AND FldtM — 4' TI*X WV _LS W/13 REBAR 0127 0_C. EACH WRY S TO 6' — C THICK WALLS W/(3 REBAR M12' O.C. EACH WAY 0' TO S — 8- THICK WALLS 1/13 RED 012' O.C. EACH WAY 9 ft. 6 ft 3& _l - J J EXGw M KID THE ANGLE OF REPOSE IS ALLOWABLE PROVIDED: SHORING IS 1NSTAIIED AT EXC TON AND SHORING SHOULD BE SGFFICENT TO SECURE SODS FROM EROSION OR SEFIEEMEIIT * NO LVDE1MIR NG OCCld�S OR Eft(MM APPROVED IF ANY DOES * CO PA,CTON TEST OF THE BAtao-11 LED WATEIIAL ARE PROVIDED PRIOR M THE POURING OF THE PAW MISC. NOTES 1. ALL STEPS AND SWUM BENCH EDGES WILL K NIE 2x6 CAP1tE BORDER OF OPPOSITE COLOR OF GEM FNW FOR NSDILR 2. HNDNOID TO BE NSIA LLD ARE VIEW DECK RAISED +6' ABOVE POOL Z X ! 0 0 O NOJ Z N rsa ' X 4 to o v O M: N e - Za a- .- ML' L,�: 1. TREAD 6 MN OF 10' WE 2 BOTTOM M TOP RISERS MAY VARY N HEIGHT 3. RISER NOT GREATER TWN 12' EXCEPT BOTTOM SU WWRE DEI M IS 4' OR GREATER 4. ALL STEPS TO 8E SOLD QNITE 30DI) PS.L STEPS (Na SCALE) rH�- m1EMrnE �4t1E a MF71 —w U� FROM !:_W DRAW k ATTACH AIX MW MEW" tNE 11EN arrm POOL WHIM s"x GRATE SHALL BE SECURED IN I Pt10E SO THAT TOGS ARE REQUIRED FOR REMOVAL Y,' PER FT. IN SLOPE aR CAP nE t 6' ABLE TILE TTYP.;�WALRL-3,000 NTEtIOR FIBER MIX FINISH PSI GUNITE STEEL—TEX FORM OR KRAFT WALL - 6' TYP. TRENCH DRAIN FLOOR #3 @ 12 O.C.B.W. ` NOTE FOR DEPTHS GREATER THAN 6' ADD TREADED (1)13 COVE BAR 06- 0 PLUG _C_ s GRAVEL TO PUMP ,,.. TIT. WALL SECTION & WELL POINT (NO SCALE) to COPPER TO GRO HORIZONTAL INSTALL 18 COPPER Ta GRID VERTICAL INSTALL PoolBond PB-2008 Install in Plumbing T at least 3" Below Water level in Return PipingAnstall in sprinkler box for easy access WATER BOND DETAIIS FOR NICBLESS LIGHT SYSTEM POOL LIGHT JUCTKIN BOX Z cD POOL PATIO WATER LEVEL 3---t 'r-' :. ram: ;..: `• - UNDERWATER r� `— 12 VAC FRAM LIGHTg ; . POWER SUPPLY - SIZE AS DETERMINED BY LICENSED ELECTRICIAN YARD BY EQUIPMENT POOL FINISH 1' PVC SCHEDULE 40 PVC SLEEVE CONDUIT NO BONDING OR GROUND REQUIRED NICHLESS UNDERWATER LIGHT DETAIL (NO SCALE) (2) #3 REBAR OR (1) #5 REBAR IN • FOOTER DETAIL (NB SCALE) a- PIPING SCHEMATIC CUSTOM MOLDED PRODUCTS INC. SINGLE CHANNEL DUAL Ot1tLEf CMP 25506-32X VGB PER FRC4501.6.6 COMPLIANT 32" CHANNEL DRAIN COMPLIANT WHtH 2D20 FLORIDA RUM CODE USIED TO ASIFIANSI Al 12 32' CHANNEL DRAIN AND SUMP 25506-320-000 *THREE 2' SOCKET x 2.5' SPIGOT PORTS *DEBRIS GUARD FICLUDED *38.79in? OPEN AREA *IAMM LISTED FLOW RATES *WHITE PVC BODY *COVER GOES OVER BODY TO GIVE FINISHED LOOK TO The mmurn urn lbw rating for this suction fitting pith the center pat phgged and outer pats open is 308 GPM (floor) and 212 GPM (wd) when using 2.5' phMnbi g and 268 GPM (floor) and 192 GPM (wall) when using 2- pkMnbing. The maximum flow rating for ft suction fft ng with the outer pats plugged and the center pat open is 2DO GPM (Door) and 168 GPM (wd) when using 2.5- phgrnbing and 184 GPM (floor) and 176 GPM (wit) when wing 2' plumbing. inw± nynamc Haan WE JandV FtoPro Series PunFps Max -Rated tFHPM) Rxmol. i!r Sq.n.r4 1 JPsn ' HAdt a wFrR DECK __\ 1 ROW OF WATERLINE THE 3 _-6" WATERLINE — _� MAX 6'-0" L r1s FLOOR /3 SIEEI 0 12- O/C E.W. 6* THICI( FLOOR SLOPES F MR cnc Soul i1F REGO NB.Y uNIF M ND COMPLY Nei 101F7ES 5AI THE SLOPE OF 1r£ Hag FROM TFE 3" Be wwL lanwwms 1FE D" AEA SWLL MOT FXC21:D 1 F= N 7 F'aa 5'-0" TYPICAL SECTION THRU POOL (Nil SCALD Pipe Size 6 fps 8fps i' 16 gpm 0.14' 21 gpm 0.23' 1.5' 37 gprn 0.08' 50 gpm 0.14' 2' 62 gpm 0,06' 82 0.10' 2.5' 88 gpm 0.05' 117 gpm 0.09' 3' 136 gpm 0.04' 181 gpm 0.07' 4' 234 gpm 0.03' 313 gpm 0,05' 6' 534 gpm 0.02' 712 gpm 0.03' Determine System Flow Rate: Minimum Flow Rate Required: 35 gpm per skimmer 1. Calculate Pool Volume: --- ft -- x 7.48(gal/Ft) = (Surface Area) (Average Depth) (volume in golk)ns) 2. Determine Flow Rate: 27,871 gal / 705 = 40 + XXX = XXX (volume) (Turnover Minutes) (Pool Flow Rate) (Feature Flow Rate) (System Flow Rate) Determine Pipe Sizes: Trunk Piping to be 2.5 inch to keep velocity 0 8 fps max. at 117 gpm Maximum System Flow Rate. Return Piping to be 25 inch to keep velocity 0 8 fps max. at 117 gpm Maximum System Flow Rate. Main Drain Cover( SEE ABOVE ) System Flaw Rate must not exceed approved cover flow rate. (Make and Model) See Engineering Page for Drain Configuration Pwmp Model DANDY FLOWPRO 2 SP H.P. 1.5 Tout H.P =H.Px service bclor.1 HtA or more must be 2 speed or wdable speed Rker Make DANDY CS Size 100 Filler mk area based an W know low rite pod gat. /3M n*L =Flow Rage D" G.P.M. by Cartridge = M or Sand =15 or D.E. = 2 Tw* Controller mace INTERMATIC Model T40004RT3 Cads must operab a mwwn m of two speeds. The IsMer speed override is not to exceed One rromnalcvde_ or 24 his, whit:twer is less LOUDEN POOLS MDERSON RESIDENCE 5284 SLASH PINE TR FT PIERCE, FL N�pLL ��� �P . • `G E IV M.gAllgaLUR 41 LiF� No. r2 —_ .ia baniwood Dn FL 34911?� 10-06-202 T ***ELECTRIC NOT INCLUDED*** PREPAR D BY: SHEET: STEVE HORST DRAFTING & DESIGN SERVICES (�)20 -� l� 3 Total Dynamic Head Calculation Worksheet jalr1q yerics 2caiuc - companyAOUDEN job #:0 Oat.: 1aw"21 Job Name:iANDERSON-MGN SFMD Address:- City�Town: Stare: FL Zip Cade: fnstactionsData can only be added to the yehow -fis. Steps #1 ,1 2 are for catcutating Pool Vokune in Gallons and for establishing a turnover rare M Gallons Per Minute 1GPM). If the turnover ate is already established, click on the GPM cell at the end of Step #2 and input flow rare, dnen proceed to Step #3 Pressinq the RESET button wiR clear all -puted information to start a new wonksheet Worksheet can be saved to a Ne or Arno of for future -iteration Cat. or Pros :ng the R£ E7 p *'ton w i ear att .System TDH Calculation Results Total Friction Loss in Ft of 43,41 Wage Pool Volume Water (TDH) 0 ` ^` o To ai Friction Loss to P51 1$_79 „o ,. m.,tm e alo s tequ ra c vr;pty w : APGP 78 ano t e :s 5t ,lords Versa Plumb Reduction Results Icuiate GPM & Raw . TDH Reduction 8.00 0 3fi0 89 System TDH with Versa Plumb 35.41 ..a. Calculate Total Length of Suction Pare 1--fed velocity 6 r4.�< !I . 8.54 C052 25- 8.05 0-052 3.. 3.d3 0.076 4" 223 0.005 _.00 3 7.r7 3 co 0C3 3CJ 7.C-1 000 ..v.� 89 5" +9l1 Coal 3C0 3cC TOTAL j 0.00 0.00 Wate Total Length of Return Pipe: fiecorrini d velocity: 8 fps and below} -�"r- I w fill 0.42D 10 4.20 1.82 r asi 0.122 0,00 0.00 z5' 6AS 0.052 142 742 321 r 3.83 0.018 too 0.00 4- 2.23 OA05 0.00 0.00 6" 0.98 1a.aoi TOTAL 0.00 ii.61 0,00 5.03 Wate Total Number of Pipe Filling.: (bnput Totaf deaN Sue Fitting i yellow Calls) r t - 'h a' $ MEE 10.07 a 3e F,;cna„ ia.s aw w~ 1007 000 0.00 000 0,00 O.DO 2 3 at wa� ODO 0-00 0.00 0.73 OA0 0.C? 2.5" 11 1 3 2 2.42 4,60 0.00 0.00 0.47 0.53 3 C3 1" :.3C 3 c3 Hitiut tog ix Fs a warn 0.00 0O6 0.00 0.00 O,110 3.67 4^ C.:;C 0 C0 cr.eon less m K- a way 0.00 0.00 0.00 000 boo - � � 6^ C.00 O.G? Fr t,agk. w a water 0.00 0.00 0.0o O.W O.OD 0.00 71DfAt.' 16-40 710 lain St t S bo & Discharge L 0" ai late r- t L oss r 'hvt sv."": ,-,� e x " `x`R„+, .v; ♦ mr. :1 t xn.a `°S�.«: . �;?.: ba .k• y x .��; y §:n-F'd i 5 § •'S)'T�4;Ys'. 260 0.87 234 1.01 Select Jandy 3-Way Valve s•a' 'fp°'�` StraightFlow Size: I 0.00 0.00 y 2" OAO 0.00 2 5- 2 4.66 2-02 r 0.00 0.00 �Sdspt"AaI11t3�Yaive 90° 40' 7.5" 3- 0.00 0.00 2" 0.00 0.00 2S" 0,00 OAO I 3" 0.00 0.00 Total 3-Way V w Loss 4.66 Z02 Kzzm- Sef t J dy F lie Type ..it & :25: 1 D. 1 52 .. lect Jandy 8 kwash Valve. j� NE9Yi k."=tu 4e Yal 9 Mir ^+ a •,00o Select Caretaker hi41i Vatee• fi Select Check Valve nalylt n Sttaighght Ffow Slze: i 1.5" 0.00 0.00 r Om 0.0D 2.5- 0.00 D.00 37 o.00 0.00 ltMo1e01eK COO D.OD T 111-0411 0.00 2.>f• GAO 0.00 Total Check Vauttew OAD 0.00 e,:tJandyH f Type andSeC dK`i 8UR4JC ^4411ayt � .F. - `d_re n 0.04 teeia" 9a'IaLa NIP 0 2 #T �P 113{ -r 2.89 1 1 25 Jan Pro Series Ma Total Dynamic Head Ta Calculation Worksheet �Prry sits Cortepa»y- 01JDEN .lab #4'� Da6s. 10fN202f Job Name. NDERSON-LOW SPEED Address. Chy,7owm,State:® Zld Coda-' instructions: Data can only be added to the yelfow cells. Steps 91 8 2 are fur cafcularmii Pool Volume in Gallons and for establishing a turnover rate in Galfons Per Minute (GW- if the turnover rate is atready established. click on the GPM cell at the and of Step #2 and input flow rate, then proceed to Step #,I Pressing the RESET bum u will clear all inputedirrf---tion to start a new Worksheet. Worksheet ran be saved to a file or pnnted for futurtlelertelce- Ca.0 Prescng ha RESET beh n - f -tear a;i System TDH Calculation Results V et7s ,.al,s t t rt a xeW orksheet. Total Friction Loss in FL of 11.43 Cakulaie P<wi Vol.ne Water (TDH) 0 """0`. Total E'rictiWtlossMPSI 4.95 '? APSn 15 nJ "t'e 24 Stanxiards Versa Plumb Reducbon Results Ic l to GPl18, TwTtwner 0lrie m ibiirs TDH Reduction 2.90 Fili., sytaan TDH with Versa 8.53 Plumb Fi t... m?.7 tY ? Y apryFY S F kf R d TMk Calc1 t Total Length of Suction Pipe (recommended eloMy 6 fps and below) L4 sl � s },�.� to �;. • f:f w: l.. :v di?"<�sda 'Y� x,?."'r »� ,. .1,..'.. �w'«' t 5" 305 7 C_ C 2" 3.84 v.3:5 0.00 0.00 2.5' 2.72 C.^"2 3" 1.72 C_JC4 4" 1.00 C.3C1 0.00 0.00 000 0.00 vn.a 0.00 0.00 ei,a„a. 6" 0.44 c X0 �O : - akWate Total Length of Return Pipe fret 000 obo low - 0.00 0.00 req.-d APSP 15 & Title 24 S`tand.,d,; *11111100 rx rcs �095« 628 0095 16 Odi 2" 3.84 0.028 000 000 Z5" 172 0012 142 169 0.73 3" 1.72 Ou04 D00 0.00 4" 1-/O 0.001 obo 0.00 6" A44 I 0.000 000 0.00 7t1'fAtl. 2.64 1.14 al -late Total Number of Pipe MOW. "mpg tatalM each Sire Fitting in Y#Bow Calls) - S 3 59 w.rm E,au 226 00C 0.00 000 0w Fea wale. 2 3 C 17 C7 fricb-on lm M 0-00 0.0C I OAD 0.17 O.OD 3 CJ Fr -swain, 2.r 11 3 2 F dw . 1.05 0.0L 0.00 0.11 0.12 3L3 3" C 3c :3 Fnct a. loos m Fr. a.- C.Jc 0.00 0.00 0.00 0.00 0G3 4" F`tcnas -n" 0:0c 000 000 000 0(j0 Out) 6" C.JC J c3 Fie6vn t>� la Ft a way 0.3C cat 0.00 0.00 0.00 0.00 'M'M 3.73 1.61 icui to St [ S W 8 Ih Charge L ft ai .late 6 n Los 2A0 097 T 3 1 13 0.55 0.25 Select Jandy 3-Way Valve Straight FI- Sae: : gh IV 0.00 coo r /m 000 2S- 2 1.02 0.44 r 0.00 D.00 ect J dy F tte Type no Ste: fj 100 043 Select Jandy Backwash Valve: I NIeY �'�' 3e Waive �'r/ NVY 7'eaker 4n floor Valve 0A0 Select Jandy Check Valve Staeght Flow S- s..Va D.Do 0.00 ?" 0.00 0.00 2 5- 0.ao D.00 3- 0.00 O.aO Select Jandy Check Valve 90" Flow S- v0. FlFw 1 5- O.DD ago 2" O.Do 0.00 2..5- 0.00 0.00 Total Check Valve Loss 0.00 0.00 1 Jandy Heat Type and S l-t Aq... e$aKow ISO E-11 9a fnstan ", Jan , i�r0 Series he 70DI.9C o= goo nit Imo 4o4ni ¢ �o_w Zi 2 god o�m� At-- Fm ((itj �z®aw W mS-t4'm Q Ego QOA conzo ¢ 2 aw 35 v 20 �c�i3 ca r�itwa �mc�i�a�. y Z R4V zt P4 O� U rA 00 6v' am ¢CIAR z zACQ to H�? N z P4 O T- S2 _ C Nzad tzg kill/ Rt o m E. to ,a Vl n�"'r-i '� Pk �5 'ram N m a3 �C � & z z o a � •-, � S ct � zQ pa�� FU UUNWQ '� �ii� a �3 tall 04 O a coU r» J (y''�� 04 .-- !mom 0 � �• t/3 Q U W Rom, �x Q A H�`-1 ctia U xa R U �" zQz O d wz w P4 Q r- l w o04 z O o E+ o x Ch �j Q c R. 43s '�° pq U E+ Q� 40M Qso O Q .x a zz co PA „w a oz �CQ t�ntit.o zU 00 W m ce �i MOOS 112 - 0 0000 .r �zQ ' n g OD�7 UHF U 0 W 14 � U o m a 94 a azrz oa U O� 3i �3 WW of V fa3 z 112' SHEET METAL SCREW 1:4' x 3i6' TAP CON HEATER 2' GALVANIZED ANGLE BRACKET OR PUMP/FILTER FRAME (TYP) 3 3112' rain. THICK CONCRETE SLAB a - HEATER FILTER d POOL EQUIPMENT ANCHOR DETAIL V( E WE U F . ANCE C� �, .� COLINTY AE DF.CTGNFn FOR - LOUDEN POOLS ANDERSON RESIDENCE 5284 SLASH PINE TR FT PIERCE, FL 111111�ii,if, opLL RpQG'i���i .` `2'•'y4GENg .F` '. 4LROW tM2 '* :FL beew No. 68212 =t801 Rw1wood Drive*, _ 10-06-202" FIL 3t9s2 = e- / vfrltrnw, PREPARED BY: JHE> l: STEVE HORST DRAFTING & DESIGN SERVICES 3 (772)201-7846 horswevoyahoo corn