HomeMy WebLinkAboutAPPROVED, Combined Power PlanPOWER RISERSCALE: N.T.S.A4SPECIFICATIONSNO.DESCRIPTION1.DRAWINGS ARE DIAGRAMMATIC AND SHALL NOT BE SCALED FOR THE EXACT LOCATION OF EQUIPMENT,CABLEWAYS OR OTHER ITEMS. REFER TO THE ARCHITECTURAL PLAN AND ELEVATIONS FOR EXACTLOCATION OF ALL EQUIPMENT AND CONFIRM WITH OWNERS' REPRESENTATIVES.2.THESE PLANS DO NOT SHOW EVERY MINOR DETAIL OF CONSTRUCTION. THE CONTRACTOR IS EXPECTEDTO FURNISH AND INSTALL ALL ITEMS FOR A COMPLETE ELECTRICAL SYSTEM AND MEET ALLREQUIREMENTS NECESSARY FOR EQUIPMENT TO BE PLACED IN PROPER WORKING ORDER.3.ALL WORK SHALL BE DONE IN ACCORDANCE WITH ALL ELEMENTS OF THE FLORIDA BUILDING CODE (2020,7TH EDITION) INCLUDING, BUT NOT LIMITED TO, THE BELOW SECTIONS OF THE NFPA. IN ADDITION, ALLWORKMANSHIP AND MATERIALS SHALL COMPLY WITH APPLICABLE NATIONAL, STATE AND LOCAL CODES,RULES, AND ORDINANCES. 70-17 (NATIONAL ELECTRIC CODE, 2017 EDITION) 72-16 (NATIONAL FIRE ALARM AND SIGNALING CODE, 2016 EDITION) 101-18 (LIFE SAFETY CODE, 2018 EDITION)4.THE ELECTRICAL SYSTEM SHALL BE COMPLETELY AND EFFECTIVELY GROUNDED AS REQUIRED IN ARTICLE250, NATIONAL ELECTRICAL CODE.5.THE ELECTRICAL INSTALLATION SHALL MEET ALL STANDARD REQUIREMENTS OF POWER, LIGHT COMPANYAND TELEPHONE COMPANY.6.ALL WORK SHALL BE PERFORMED BY A LICENSED CONTRACTOR IN A FIRST CLASS, WORKMAN-LIKEMANNER. THE COMPLETED SYSTEM SHALL BE OPERATIVE AND ACCEPTANCE BY ENGINEER/ARCHITECTSHALL BE A CONDITION OF ANY SUB-CONTRACT.7.THE ELECTRICAL CONTRACTOR SHALL PROVIDE A WRITTEN WARRANTY THAT SHALL GUARANTEE ALLWORKMANSHIP AND MATERIALS FOR ONE YEAR FROM THE DATE OF FINAL WORK ACCEPTANCE BY THEOWNER OR OWNERS REPRESENTATIVE8.ARCHITECTURAL AND/OR ENGINEERING EXPENSES THAT ARE INCURRED DUE TO REVISIONS ORSUBSTITUTIONS REQUESTED FOLLOWING THE ISSUE OF APPROVED DRAWINGS SHALL BE PAID FOR BY THECONTRACTOR.9.ALL 15A AND 20A, 120V, GENERAL BRANCH CIRCUITS, CARBON MONOXIDE/SMOKE ALARM COMBO UNITSAND LIGHTS ARE TO BE PROTECTED BY ARC FAULT CIRCUIT INTERRUPTING BREAKER-PER NEC WITH THEEXCEPTION OF GARAGES AND THE EXTERIOR. ALL WET AREAS, INCLUDING BUT NOT LIMITED TO,KITCHENS, BATHROOMS, UTILITY/LAUNDRY ROOMS, AND THE EXTERIOR, SHALL BE PROTECTED BYGROUND FAULT INTERRUPTING CIRCUIT BREAKERS PER NEC. PROVIDE TAMPER RESISTANT TYPERECEPTACLES PER NEC, NORMALLY USED FOR GENERAL POWER AND ILLUMINATION.10.UNLESS OTHERWISE NOTED, ALL CONDUCTORS SHALL BE COPPER, WITH "THHN" INSULATION FOR SIZE #10AND SMALLER. CONDUCTORS LARGER THAN #10 SHALL HAVE "THWN" INSULATION. ALL CONDUCTORS #10AND SMALLER MAY BE SOLID. ALL CONDUCTORS #8 AND LARGER SHALL BE STRANDED.11.THE CONTRACTOR SHALL PAY FOR ALL PERMITS, FEES, INSPECTIONS, AND TESTS.12.THE CONTRACTOR SHALL BE THOROUGHLY FAMILIARIZED WITH ALL ASPECTS OF THE PROJECT AND SHALLVERIFY ALL CONDITIONS PRIOR TO CONSTRUCTION.13.ALL INSTALLATIONS SHALL BE COORDINATED BY THE CONTRACTOR WITH OTHER TRADES TO AVOIDIMPACTS.14.ALL REQUIRED CONSTRUCTION INSURANCE FOR PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTYDAMAGE FOR THE DURATION OF THE WORK SHALL BE PROVIDED BY THE CONTRACTOR.15.CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE AND SHALL INCLUDEREPLACEMENT OR REPAIR OF ANY PHASE OF THE INSTALLATION WHICH MAY BE DAMAGED.16.THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL EQUIPMENT FOR PROPER VOLTAGE, PHASE, ANDCURRENT BEFORE CONNECTION TO CIRCUITS.17.ELECTRICAL CONTRACTOR SHALL CHECK AND VERIFY EQUIPMENT FURNISHED AGAINST THOSE SPECIFIEDOR INTENDED AND REVISE BRANCH CIRCUITS AS MAY BE REQUIRED WITH PRIOR APPROVAL OFENGINEER/ARCHITECT.18.ALL MATERIALS SHALL BE NEW AND SHALL BEAR UNDERWRITERS LABEL WHERE APPLICABLE.19.EQUIPMENT SHALL BE U.L. APPROVED.20.OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, CAST ALLOY WITH THREADED HUBS IN WETLOCATIONS AND SPECIAL ENCLOSURES FOR OTHER CLASSIFIED AREAS.21.DISCONNECT SWITCHES SHALL BE H.P. RATED, HEAVY DUTY, QUICK MAKE, QUICK BREAK, WITHENCLOSURES AS REQUIRED BY EXPOSURE.22.CIRCUITS SHOWN ON PLANS ARE TO DETERMINE LOAD DATA AND PANEL SIZE. THE CONTRACTOR SHALLPROVIDE CIRCUITS TO SUIT JOB CONDITIONS. ANY DEVIATIONS FROM THE APPOVED PLANS SHALLGENERATE A REVISION, REVISED PLANS SHALL BE PRESENTED FOR REGULATORY REVIEW AND APPROVALPRIOR TO THE FINAL INSPECTION APPROVAL.23.FURNISH AND INSTALL LIGHTING FIXTURES AND LAMPS AS CALLED FOR ON PLANS, OR AS SELECTED BYOWNER.24.SERVICE ENTRANCE EQUIPMENT FOR ALL ELECTRICAL ELEMENTS TO HAVE MIN. A.I.C. RATING OF 42,000AMPS AND BE NEMA-3R RATED.25.ALL ELECTRICAL EQUIPMENT AND CABLING RATED @ 75°C CONTINUOUS DUTY.GENERAL NOTESNO.DESCRIPTION1.THE PURPOSE OF THIS DRAWING IS TO PROVIDE POWER ROUTING AND CONSTRUCTION DETAILS. THESEPLANS DETAIL THE FINAL ARRANGEMENT OF EQUIPMENT AND THEIR ASSOCIATED APPENDAGES.2.ANY AND ALL QUESTIONS AS TO THE INTENT OF, OR PROCEDURES SET FORTH IN THESE DRAWINGS MUSTBE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO THE SUBMISSION OF A BID. LACK OFKNOWLEDGE OR UNDERSTANDING OF PLANS SHALL NOT JUSTIFY ANY CLAIMS OR EXTRA COMPENSATION.3.ALL SYMBOLS MAY NOT BE USED FOR THIS PROJECT.4.PRIOR TO CONSTRUCTION, THE ELECTRICAL CONTRACTOR SHALL:a. VERIFY ALL EXISTING CONDITIONS IN THE FIELD PRIOR TO CONSTRUCTION.b. PRIOR TO CONSTRUCTION, THE ELECTRICAL CONTRACTOR SHALL COORDINATE THE ELECTRICALSERVICE WITH THE UTILITY'S REPRESENTATIVE.c. NOTIFY THE ENGINEER OF ANY CHANGES REQUIRED TO COMPLETE NEW CONSTRUCTION.5.ALL LIGHTING FIXTURES AND FANS TO BE SELECTED BY OWNER/ARCHITECT, UNLESS OTHERWISE NOTED.6.ARCHITECT TO SET MOUNTING HEIGHT FOR ALL FIXTURES WHERE APPLICABLE, UNLESS OTHERWISENOTED.7.FOR FLOOR RECEPTACLES, PROVIDE BRASS COVER AND COVER PLATE AND FLUSH WITH FLOOR. VERIFYEXACT LOCATION WITH GC/OWNER. PROVIDE 1/2" C UNDER SLAB FROM WALL.8.RESIDENTIAL PROJECTS: ROMEX SHALL BE CONSIDERED ACCEPTACLE WHERE PROTECTED BY THEBUILDING CONSTRUCTION. WHERE CONDUIT IS NOTED, MCCABLE MAY BE USED IN LIEU OF RIDGIDCONDUIT, WHEN ACCEPTABLE PER NEC.9.PROVIDE GREEN WIRE GROUND TO ALL EXTERIOR FIXTURES (EXCEPT WALL MOUNTED) AND JUNCTIONBOXES.10.CONTRACTOR TO CONFIRM CABLE LENGTH FROM UTILITY TRANSFORMER/METER TO FIRST CONNECTIONPOINT MEET THE NEC MINIMUM VOLTAGE DROP REQUIREMENTS.11.ELECTRICAL CONTRACTOR SHALL VERIFY THE HEIGHT OF ALL EQUIPMENT PRIOR TO INSTALLATION.12.SWITCHES ARE TO BE MOUNTED AT 48" ABOVE FINISHED FLOOR, UNLESS OTHERWISE NOTED.13.VERIFY EXACT LOCATIONS OF ALL KITCHEN EQUIPMENT WITH THE OWNER/ARCHITECT PRIOR TOCONTRACTION. VERIFY MOUNTING HEIGHTS OF RECEPTACLES.14.VERIFY MOUNTING HEIGHT OF TELEVISION OUTLETS WITH OWNER, PRIOR TO CONSTRUCTION.15.ELECTRICAL CONTRACTOR SHALL REVIEW AND COORDINATE ALL DATA, TELEPHONE, CABLE, AND OTHERLV, AUDIO VISUAL, & LIGHTING SYSTEMS WORK AND MATERIAL WITH THE LOW VOLTAGE CONSULTANT ANDINTERIOR DESIGNER.16.AV POWER BY OTHERS. ELECTRICAL CONTRACTOR TO OBTAIN ALL LOADS PRIOR TO INSTALLATION.17.PROVIDE FEED BACK AND CONTROL TO LV CONTROL SYSTEM.18.LIGHTING NOT INDICATED AS SWITCHED OR POWERED IS TO BE CONNECTED VIA LOW VOLTAGE SYSTEM.19.POWER BATHROOM EXHAUST FANS THROUGH LOCAL LIGHTING CIRCUIT AND CONTROLLED THROUGHSEPARATE SWITCH20.ALL A/C DISCONNECTS, EXTERIOR EQUIPMENT, & POOL/SPA EQUIPMENT TO BE NEMA 3R RATED.21.ALL ENTRANCES TO GRADE SHALL BE SUPPLIED WITH A LIGHT FIXTURE AND SWITCH. VERIFY WITHINTERIOR DESIGNER/LOW VOLTAGE SYSTEM PLANS.22.ALL BONDING OF PIPE AND FOUNDATION STEEL SHALL BE IN ACCORDANCE WITH NEC 250.10423.LIGHTING LEVELS ALONG PATH AND EGRESS SHOULD MAINTAIN MINIMUM 1 FOOTCANDLE MEASUREDFROM THE CENTER OF TREADS AND LANDING IN ACCORDANCE WITH FBC R303.724.MINIMUM OF 90% OF PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL HAVE HIGH EFFICENCY LAMPS,IAW FBCE-R404.1.25.ALL FIXTURE ABOVE TUB AND SHOWERS SHALL BE RATED VP IN ACCORDANCE WITH NEC 410.10 (D)LOAD CALCULATIONSAPPROXIMATE SQ. FT.:6,501QTYGENERAL LOADS DESCRIPTION KVA-GENERAL POWER & LIGHTING (3 VA/SQ. FT.)19.51A/V EQUIPMENT (1.7 KVA/UNIT)1.71ALARM, FIRE (0.5 KVA/UNIT)0.51ALARM, SECURITY (1.5 KVA/UNIT)1.58APPLIANCE, REFRIGERATION (1.5 KVA/UNIT)12.01COFFEE (1 KVA/UNIT)1.02DISHWASHER (1.2 KVA/UNIT)2.43DISPOSAL (0.9 KVA/UNIT)2.71DOUBLE OVEN, ELEC (11 KVA/UNIT)11.02DRYER, GAS (1.5 KVA/UNIT)3.07DWELLING SMALL APPLIANCE & LAUNDRY (1.5 KVA/UNIT)10.51GARAGE DOOR (0.5 KVA/UNIT)0.51HEATER, GAS (0.5 KVA/UNIT)0.52HOOD (1.5 KVA/UNIT)3.01HVAC (1.8 KVA/UNIT)1.82LIGHTING, POOL/SPA (0.5 KVA/UNIT)1.01PUMP, HOT WATER RECIRC (1.5 KVA/UNIT)1.51PUMP, JACUZZI (6.2 KVA/UNIT)6.21PUMP, POOL/SPA (6.2 KVA/UNIT)6.21PUMP, WHIRLPOOL (1 KVA/UNIT)1.01RANGE, GAS (1.8 KVA/UNIT)1.84SHADES (1.5 KVA/UNIT)6.09SPARK POWER (0.5 KVA/UNIT)4.51STEAM SHOWER (4.5 KVA/UNIT)4.52TIME CLOCK, POOL/SPA (0.5 KVA/UNIT)1.01TREADMILL (1.8 KVA/UNIT)1.81VAV (0.6 KVA/UNIT)0.62WASHER (1.5 KVA/UNIT)3.01SCREEN, MOTORIZED (1.5 KVA/UNIT)1.51CAR CHARGER (11 KVA/UNIT)11.0TOTAL KVA LOAD123.2SERVICE LOAD CALCULATIONSDESCRIPTION KVAREMARKSFIRST 10 KVA @ 100%10.0 KVAREMAINDER KVA @ 40%45.3 KVACOOLING @ 100%41.7 KVAELEVATOR @ 100%10.0 KVA TOTAL KVA LOAD107.0 KVASERVICE SIZE AMPS:512.7 AINCLUDES 15% MARGINELECTRICAL A/C LEGENDUNIT NO.PNL.FEEDV/P/HzCONDENSING UNITAIR HANDLER UNITREMARKSFEEDERSC.B. (NEMA 3R)FEEDERSC.B. (NEMA 1)AHU 1-1B240/1/602 #10'STHWN CU302 #14'STHWN CU15CU 1-11 #10 GND1/2"1 #14 GND1/2"AHU 2-1C240/1/602 #8'STHWN CU502 #6'STHWN CU60CU 2-11 #10 GND3/4"1 #10 GND3/4"AHU 2-2B240/1/602 #8'STHWN CU502 #6'STHWN CU60CU 2-21 #10 GND3/4"1 #10 GND3/4"AHU 3-1C240/1/602 #8'STHWN CU502 #6'STHWN CU60CU 3-11 #10 GND3/4"1 #10 GND3/4"AHU 3-2A240/1/602 #8'STHWN CU402 #6'STHWN CU60CU 3-21 #10 GND3/4"1 #10 GND3/4"FIRE ALARM NOTESNO.DESCRIPTION1.PROVIDE AC POWER TO SMOKE DETECTORS FROM DWELLING UNIT POWER PANEL.2.FIRE ALARM PANEL IS REQUIRED PER NFPA 72-11.8.2.2(2) (NEC 2016) [NFPA 72-29.8.2.2(2) (NEC 2016)] WHENTHE NUMBER OF SMOKE DETECTORS EXCEEDS (12) MAKING SINGLE CIRCUIT WIRING FOR POWERPROHIBITED.3.ALL SMOKE ALARMS & CARBON MONOXIDE ALARMS TO BE COMBO UNITS AND TO HAVE BATTERY BACKUPAND SIGNAL SIMULTANEOUSLY W/ TEMPORAL SOUND. SMOKE/CARBON ALARMS TO BE LOCATED MIN 3' 0"FROM: R/A & SUPPLY GRILLS, KITCHENS, BATHROOMS. SMOKE DETECTORS SHALL BE LOCATED AT THEHIGH POINT OF THE SPACE.4.ALL SMOKE ALARMS & CARBON MONOXIDE ALARMS TO BE LOCATED IN ACCORDANCE WITH NFPA 72-29.5.1.3.1 ALL POINTS ON THE CEILING SHALL HAVE A SMOKE ALARM WITHIN A DISTANCE OF 30 FT TRAVELDISTANCE OR SHALL HAVE AN EQUIVALENT OF ONE SMOKE ALARM PER 500 FT2 OF FLOOR AREA.TYPICAL OUTLETGROUNDING DETAILSCALE: N.T.S.B1MEP EQUIPMENT SHALL BE LOCATED ABOVE THE BASE FLOODELEVATION +1 FOOT, EXCEPT AS REQUIRED TO ADDRESS LIFESAFETY REQUIREMENTS.36" KITCHEN / LAUNDRY 34" @ BATH VANITIES VERIFY W/ CAB'T MANU AND ARCHITECT ABOVE BASEBOARD (6" MIN. A.F.F.)FINISH FLOORPROVIDE SOLID BLOCKINGAS REQ'DGANG SWITCHES AS POSSIBLEALIGN ALL OTHERLV/ HVAC CONTROLSW/ SWITCHESCTR / VANITYADJUST HT. AS REQ'DVERIFY EXACT HT/TYPE OF B'SPLASHUPPER TO CONCEAL LIGHT2"TYPICAL SWITCH / OUTLETDETAILSCALE: N.T.S.A1FEEDER SCHEDULE KEY NOTESNO.DESCRIPTION100600 AMP 2P, 3 WIRE FEEDER - (2) RUNS OF (2) 3" CONDUIT WITH (3) #350 COPPER110600 AMP 2P, 3 WIRE FEEDER - (2) RUNS OF (2) 3" CONDUIT WITH (3) #350 COPPER WITH (1) 1 EQUIPMENTGROUND120FUTURE STANDBY POWER - (2) RUNS OF 2" CONDUIT EACH WITH PULL CORDS. CAPPED FOR FUTUREINSTALLATION.200200 AMP 2P, 3 WIRE FEEDER - (1) RUNS OF (1) 2" CONDUIT WITH (3) #3/0 MCM KCMIL COPPER WITH (1) 6EQUIPMENT GROUND300200 AMP 2P, 3 WIRE FEEDER - (1) RUNS OF (1) 2" CONDUIT WITH (3) #3/0 COPPER WITH (1) 6 EQUIPMENTGROUND400200 AMP 1P, 3 WIRE FEEDER - (1) RUNS OF (1) 2" CONDUIT WITH (3) #3/0 MCM KCMIL COPPER WITH (1) 6EQUIPMENT GROUND700100 AMP 2P, 3 WIRE FEEDER - (1) RUNS OF (1) 1-1/4" CONDUIT WITH (3) #3 COPPER WITH (1) 8 EQUIPMENTGROUNDBLD GRDNPROVIDE (1) #2/0 GROUNDING ELECTRODE IN 1" PVC CONDUIT AND BONDED TO STRUCTURAL STEEL INBUILDING FOOTER, METAL UNDERGROUND WATER PIPE AND METAL UNDERGROUND GAS PIPE (IF AVAILABLE)IN ACCORDANCE WITH NEC 250-50, PART III. PROVIDE MADE ELECTRODES CONSISTING OF COPPER CLADEGROUND RODS (IF FLUSH TEST WELLS) 5/8" X 10'-0". MEASURE RESISTANCE TO GROUND ADD ADDITIONALGROUND RODS IF REQUIRED TO REACH THE 5 OHM LEVEL.ALL A/C DISCONNECTS & POOL/SPAEQUIPMENT TO BE NEMA-3R RATED.NOTE:"MDP"PNL 'A'PNL 'B'PNL 'P'GENERATOREMERGENCY6006002PTO FPL TRANSFORMER120-240V/1PH/60HZGROUNDING BRIDGEARLINGTON INDUSTRIESMODEL #GB5 ZINC WITH PAINTABLECOVERGRADEEXTERIORINTERIORPOOLEQUIPMENTMF2P*4040(3) #8'S(1) #10 GNDTHWN CUIN LIQ.-TIGHT FLEX. 3/4" CONDUITEXTERIORINTERIORMSPAEQUIPMENTMF2P*4040(3) #8'S(1) #10 GNDTHWN CUIN LIQ.-TIGHT FLEX. 3/4" CONDUIT*BLDGND100100110300200700BLDGNDSERVICERATEDATSPULL BOXPULL BOX120PNL 'C'400FUTUREOUTLET BOXGROUNDINGCONDUCTOR(GREEN)TAPPED HOLEIN BOXGROUNDING SCREW - #10 32x 3/8" SLOTTED HEXAGONHEAD, WASHER FACESCREW (TYPICAL)WIRE NUT(TYPICAL)CONDUIT(TYPICAL)NOTE:GROUNDING CONDUCTOR &NEURAL CONDUCTOR INMULTI-WIRE BRANCH CIRCUITSSHALL BE CONTINUOUS SO THATREMOVAL OF DEVICE WILL NOTINTERFERE WITH CONDUCTORCONTINUITY.(x2) 5/8"Øx10FTGND RODFOUNDATION STEELBOND TO BOND TOCWP.MIN 6'(x2) 5/8"Øx10FTGND RODFOUNDATION STEELBOND TO BOND TOCWP.MIN 6'ELECTRICAL SYMBOL LEGENDSYMBOLDESCRIPTIONJWPGFINOTES:S SS S SS FLRRRCOOSSD/CMFPOWER SHEET INDEXARCHSHT NOSHT NODESCRIPTIONE10101POWER NOTES, CALCS, RISERS & DETAILSE10202POWER PANEL SCHEDULESE10303SUB-PANEL POWER CALCULATIONSE20104POWER FLOOR PLAN - LOWER LEVELE20205POWER FLOOR PLAN - MAIN LEVELE20306POWER FLOOR PLAN - UPPER LEVELE30107POWER LIGHTING PLAN - LOWER LEVELE30208POWER LIGHTING PLAN - MAIN LEVELE30309POWER LIGHTING PLAN - UPPER LEVELE10100INITIAL ISSUEJWLE09.24.21PERMIT SET 09.24.21 JOHN LANGFORD, FL#69962POWER NOTES,CALCS, RISERS &DETAILS ELECTRICAL PANEL SCHEDULEPNL TAG"MDP" (1) (2)PANEL TYPE:BOLT ONPANEL AMP RATING:600MOUNTINGSURFACEVOLTS:120/240 1Ø-3WMFG:SQUARED OR EQUALPOSITIONS:24MIN. A.I.C65,000 AMPSBUS KVALOADCOND.WIRESIZEPOLEAMPSCKTBUSCKTAMPSPOLEWIRESIZECOND.LOADBUS KVAABAB37.4"A" GENERAL HOUSE PWR. (2)(1) 2"3/022001X220023/0(1) 2""B" GENERAL HOUSE PWR. (2)37.036.6 """""3X4"""" "32.239.0"C" GENERAL HOUSE PWR. (2)(1) 2"3/022005X610023(1) 1-1/4""P" POOL/SPA PWR. (2)8.535.7 """""7X8"""" "7.55.0ELEVATOR EQUIP. (2)3/4"62609X10----SPACE-5.0 """""11X12"""" "-SPACE----13X14"""" " """""15X16"""" " """""17X18"""" " """""19X20"""" " """""21X22"""" " """""23X24"""" " ØA126.9 KVAPANEL LOAD CALCULATIONSREMARKS: ØB116.9 KVALEG A AMPS528.6(1) MAIN CIRCUIT BREAKER.LEG B AMPS487.0(2) CONFIRM ELECTRICAL REQUIREMENTS.FEEDER (2) RUNS(3) #350(3) NEMA 3R ENCLOSUREGRND(1) 1PANEL SERVICE AMPS512.7FEEDER COND.(2) 3"(SEE SERVICE CALCS)ELECTRICAL PANEL SCHEDULEPNL TAG"P" POOL/SPA PWR. (2)PANEL TYPE:LOAD CENTER (1) (9)PANEL AMPS:100MOUNTINGSURFACEVOLTS:120/240 1Ø-3WMFG:SQUARED OR EQUALPOSITIONS:30MIN. A.I.C22,000 AMPS SERIES RATEDBUS KVALOADCOND.WIRESIZEPOLEAMPSCKTBUSCKTAMPSPOLEWIRESIZECOND.LOADBUS KVAABAB3.1POOL PUMP (2) (5) (7) (9)3/4"82351X235283/4"SPA PUMP (2) (5) (7) (9)3.13.1 """""3X4"""" "3.10.3POOL HEAT PUMP (2)1/2"142155X6201121/2"SPA HEATER SPK. PWR.0.50.3 """""7X8151141/2"SPA LIGHTS (2) (5) (7)0.50.5POOL LIGHTS (2) (5) (7)1/2"141159X10151141/2"SPA TIME CLOCK0.50.5POOL TIME CLOCK1/2"1411511X1215114-SPARE0.00.5SPK. PWR.1/2"1411513X14----SPACE-0.0SPARE-1411515X16"""" "-SPACE----17X18"""" " """""19X20"""" " """""21X22"""" " """""23X24"""" " """""25X26"""" " """""27X28"""" " """""29X30"""" " """""31X32"""" " """""33X34"""" " """""35X36"""" " """""37X38"""" " """""39X40"""" " """""41X42"""" " ØA8.5 KVAPANEL LOAD CALCULATIONSREMARKS: ØB7.5 KVASEE LOAD CALCULATIONS(1) MAIN LUGS ONLY.(2) CONFIRM ELECTRICAL REQUIREMENTS.FEEDER QTY1(3) PROVIDE ARC-FAULT INTERRUPTING CIRCUIT BREAKER.FEEDER CU3(4) NON-CONCURRENT LOADS. PROVIDE "HACR" RATED BREAKER.GRND CU(1) 8(5) VERIFY LOCATION.COND.(1) 1-1/4"(6) POWER EVAPORATOR UNIT THROUGH CONDENSING UNIT. SEE MNF. INSTALL DIRECTION.(7) POOL/SPA EQUIP. TO BE SUPPLIED W/ GFI BREAKER IAW NEC 680.22 (B).(8) CONTROLLED THROUGH TIME CLOCK(9) NEMA 3R ENCLOSUREELECTRICAL PANEL SCHEDULEPNL TAG"C" GENERAL HOUSE PWR. (2)PANEL TYPE:LOAD CENTER (1)PANEL AMPS:200MOUNTINGRECESSEDVOLTS:120/240 1Ø-3WMFG:SQUARED OR EQUALPOSITIONS:42MIN. A.I.C22,000 AMPS SERIES RATEDBUS KVALOADCOND.WIRESIZEPOLEAMPSCKTBUSCKTAMPSPOLEWIRESIZECOND.LOADBUS KVAABAB5.8AHU 2-1 (2) (4)3/4"62601X250283/4"CU 2-1 (2) (4)4.25.8 """""3X4"""" "4.25.8AHU 3-1 (2) (4)3/4"62605X650283/4"CU 3-1 (2) (4)4.25.8 """""7X8"""" "4.21.5UC. REFRIG.(3)-121209X1020112-REFRIGERATOR (3)1.51.5FREEZER (3)-1212011X1220112-DRAWER REFRIGERATOR (3)1.51.5UC. ICE MAKER (3)-1212013X14201121/2"RANGE, GAS (2)1.81.5EXHAUST HOOD (5) (3)-1212015X1615114-SPARE0.01.5RECEPT, KITCHEN SM APP (3)-1212017X1820112-RECEPT, KITCHEN SM APP (3)1.50.8WINE ROOM FCU/CU (2)1/2"1421519X2020112-UC. ICE MAKER (3)1.50.8 """""21X2220112-WINE COOLER (3)1.50.5GARAGE DOOR-1411523X2415114-RECEPT, MAST BED RM (3)1.41.5RECEPT, MAST BATH (3)-1212025X2615114-RECEPT, GREAT ROOM (3)1.40.5WATER HEATER, SPK. PWR.-1212027X28201121/2"RECIRCULATING PUMP1.50.0SPARE-1411529X3020112-SECURITY ALARM SYSTEM (2) (3)1.50.5SMOKE DETECTORS (3)1/2"1411531X3220112-GENERAL LIGHTING (3)1.51.5GENERAL LIGHTING (3)-1212033X3420112-GENERAL LIGHTING (3)1.51.5GENERAL LIGHTING (3)-1212035X3620112-GENERAL LIGHTING (3)1.5-SPACE----37X38----SPACE- """""39X40"""" " """""41X42"""" " ØA39.0 KVAPANEL LOAD CALCULATIONSREMARKS: ØB35.7 KVASEE LOAD CALCULATIONS(1) MAIN LUGS ONLY.(2) CONFIRM ELECTRICAL REQUIREMENTS.FEEDER QTY1(3) PROVIDE ARC-FAULT INTERRUPTING CIRCUIT BREAKER.FEEDER CU3/0(4) NON-CONCURRENT LOADS. PROVIDE "HACR" RATED BREAKER.GRND CU(1) 6(5) VERIFY LOCATION.COND.(1) 2"(6) POWER EVAPORATOR UNIT THROUGH CONDENSING UNIT. SEE MNF. INSTALL DIRECTION.(7) POOL/SPA EQUIP. TO BE SUPPLIED W/ GFI BREAKER IAW NEC 680.22 (B).(8) CONTROLLED THROUGH TIME CLOCK(9) NEMA 3R ENCLOSUREELECTRICAL PANEL SCHEDULEPNL TAG"B" GENERAL HOUSE PWR. (2)PANEL TYPE:LOAD CENTER (1)PANEL AMPS:200MOUNTINGSURFACEVOLTS:120/240 1Ø-3WMFG:SQUARED OR EQUALPOSITIONS:42MIN. A.I.C22,000 AMPS SERIES RATEDBUS KVALOADCOND.WIRESIZEPOLEAMPSCKTBUSCKTAMPSPOLEWIRESIZECOND.LOADBUS KVAABAB0.3AHU 1-1 (2) (4)1/2"142151X2302101/2"CU 1-1 (2) (4)1.30.3 """""3X4"""" "1.35.8AHU 2-2 (2) (4)3/4"62605X650283/4"CU 2-2 (2) (4)4.25.8 """""7X8"""" "4.21.8APRILAIRE UNIT (2)-121209X1020112-VAV(S) (2) (5) (3)0.61.4RECEPT, BEDROOM 2 (3)-1411511X1220112-RECEPT, BATHROOM (3)1.51.5DRYER, GAS. (2) (3)-1212013X1420112-WASHER (3)1.50.0SPARE-1411515X1620112-RECEPT, UTILITY MAIN LEVEL (3)1.55.5OVEN, DOUBLE, ELEC (2)3/4"626017X1820112-RECEPT, KITCHEN (3)1.65.5 """""19X2020112-RECEPT, KITCHEN (3)1.61.4RECEPT, DINING (3)-1411521X22151141/2"SPK. PWR.0.50.9DISPOSAL-1212023X2420112-DISHWASHER1.21.2DISHWASHER-1212025X2615114-RECEPT, HALLWAY LOWER LEVEL (3)1.40.5SPK. PWR.1/2"1411527X28151141/2"SPK. PWR.0.51.4RECEPT, CLUB RM (3)-1411529X3020112-DISPOSAL0.91.4RECEPT, BAR (3)-1411531X3220112-SHADES, MOTORIZED (2) (3)1.51.5SHADES, MOTORIZED (2) (3)-1212033X3420112-GENERAL LIGHTING (3)1.51.5GENERAL LIGHTING (3)-1212035X3620112-GENERAL LIGHTING (3)1.51.5GENERAL LIGHTING (3)-1212037X3820112-GENERAL LIGHTING (3)1.5-SPACE----39X40----SPACE- """""41X42"""" " ØA37.0 KVAPANEL LOAD CALCULATIONSREMARKS: ØB32.2 KVASEE LOAD CALCULATIONS(1) MAIN LUGS ONLY.(2) CONFIRM ELECTRICAL REQUIREMENTS.FEEDER QTY1(3) PROVIDE ARC-FAULT INTERRUPTING CIRCUIT BREAKER.FEEDER CU3/0(4) NON-CONCURRENT LOADS. PROVIDE "HACR" RATED BREAKER.GRND CU(1) 6(5) VERIFY LOCATION.COND.(1) 2"(6) POWER EVAPORATOR UNIT THROUGH CONDENSING UNIT. SEE MNF. INSTALL DIRECTION.(7) POOL/SPA EQUIP. TO BE SUPPLIED W/ GFI BREAKER IAW NEC 680.22 (B).(8) CONTROLLED THROUGH TIME CLOCK(9) NEMA 3R ENCLOSUREELECTRICAL PANEL SCHEDULEPNL TAG"A" GENERAL HOUSE PWR. (2)PANEL TYPE:LOAD CENTER (1)PANEL AMPS:200MOUNTINGSURFACEVOLTS:120/240 1Ø-3WMFG:SQUARED OR EQUALPOSITIONS:42MIN. A.I.C22,000 AMPS SERIES RATEDBUS KVALOADCOND.WIRESIZEPOLEAMPSCKTBUSCKTAMPSPOLEWIRESIZECOND.LOADBUS KVAABAB5.8AHU 3-2 (2) (4)3/4"62601X240283/4"CU 3-2 (2) (4)3.45.8 """""3X4"""" "3.41.4RECEPT, HALLWAY UPPER LEVEL (3)-141155X615114-RECEPT, BEDROOM 3 (3)1.41.5RECEPT, BATHROOM (3)-121207X815114-RECEPT, MAST BED RM (3)1.42.3STEAM SHOWER (2) (5)1/2"102309X1015114-WHIRLPOOL TUB (2) (3)1.02.3 """""11X1220112-DRYER, GAS. (2) (3)1.51.5WASHER (3)-1212013X1415114-SPARE0.01.5RECEPT, LAUNDRY UPPER LEVEL (3)-1212015X16151141/2"SPK. PWR.0.51.4RECEPT, OFFICE (3)-1411517X1820112-TREADMILL (3)1.81.4RECEPT, LOUNGE (3)-1411519X2020112-DISPOSAL0.91.0COFFEE MAKER (2) (3)-1212021X22151141/2"RECEPT, EXTERIOR UPPER LEVEL1.41.5SHADES, MOTORIZED (2) (3)-1212023X2420112-SHADES, MOTORIZED (2) (3)1.51.5SCREEN, MOTORIZED (2) (3)-1212025X26201121/2"ROLL DOWN SCREEN LIFT PWR. (2)1.51.4RECEPT, OUTDOOR LIVING1/2"1411527X28151141/2"SPK. PWR.0.51.4RECEPT, EXTERIOR MAIN LEVEL1/2"1411529X30151141/2"SPK. PWR.0.51.5EXHAUST HOOD (5) (3)-1212031X326026-CAR CHARGER (2)5.51.5RECEPT, GARAGE-1212033X34"""" "5.51.4RECEPT, FOYER (3)-1411535X3615114-RECEPT, UNFINISHED/NON-HABITABLE (3)1.41.4RECEPT, STORAGE (3)-1411537X38151141/2"RECEPT, EXTERIOR LOWER LEVEL1.41.4RECEPT, STORAGE (3)-1411539X40----SPACE--SPACE----41X42"""" " ØA37.4 KVAPANEL LOAD CALCULATIONSREMARKS: ØB36.6 KVASEE LOAD CALCULATIONS(1) MAIN LUGS ONLY.(2) CONFIRM ELECTRICAL REQUIREMENTS.FEEDER QTY1(3) PROVIDE ARC-FAULT INTERRUPTING CIRCUIT BREAKER.FEEDER CU3/0(4) NON-CONCURRENT LOADS. PROVIDE "HACR" RATED BREAKER.GRND CU(1) 6(5) VERIFY LOCATION.COND.(1) 2"(6) POWER EVAPORATOR UNIT THROUGH CONDENSING UNIT. SEE MNF. INSTALL DIRECTION.(7) POOL/SPA EQUIP. TO BE SUPPLIED W/ GFI BREAKER IAW NEC 680.22 (B).(8) CONTROLLED THROUGH TIME CLOCK(9) NEMA 3R ENCLOSUREE10200INITIAL ISSUEJWLE09.24.21PERMIT SET 09.24.21 JOHN LANGFORD, FL#69962POWER PANEL SCHEDULESA1POWER PANELSCHEDULES NEC ART. 220 PART III DWELLING LOAD CALCPANEL:"P" POOL/SPA PWR. (2)VOLTAGE VLL240VOLTAGE VLN120PHASE1GENERAL LOAD DESCRIPTION KVADFTOTALGENERAL LOADLIGHTING0.8x1.00=0.8SMALL APPLIANCE0.0x1.00=0.0WASHER0.0x1.00=0.0SUBTOTAL=0.75FIRST 3 KVA @ 100%0.8x1.00=0.8REMAINDER KVA @ 35%0.0x0.35=0.0REMAINDER KVA @ 25%0.0x0.25=0.0GENERAL KVA LOAD=0.75NON DWELLING RECEPTACLE LOADRECEPTACLE0.0x1.00=0.0SUBTOTAL=0.00FIRST 10 KVA @ 100%0.0x1.00=0.0REMAINDER KVA @ 40%0.0x0.40=0.0RECEPTACLE KVA LOAD=0.00DRYER LOAD0DRYER0.0x1.00=0.0DRYER KVA LOAD=0.00FIXED APPLIANCE LOAD0FIXED APPLIANCE0.0x1.00=0.00WATER HEATER0.0x1.00=0.0SUBTOTAL=0.000APPLIED DIVERSITY0.0x1.00=0.0APPLIANCE KVA LOAD=0.00COOKING APPLIANCE LOAD0COOKING COL A0.0x1.00=0.00COOKING COL B0.0x1.00=0.00COOKING COL C0.0x1.00=0.0COOKING KVA LOAD=0.00HVAC LOADCOOLA/C AIR HANDLER FANS0.0x1.00=0.0A/C -- FRESH AIR MAKE-UP0.0x1.00=0.0A/C CENTRAL UNIT LOAD -- COOL0.0x1.00=0.0LARGEST AC EQUIPMENT0.0x0.25=0.0LARGEST HVAC COOL LOAD @ 125% + REST @ 100% SUBTOTAL=0.00HEATA/C AIR HANDLER FANS0.0x1.00=0.0A/C AIR HANDLER HEAT STRIPS0.0x1.00=0.0A/C -- FRESH AIR MAKE-UP HEATING0.0x1.00=0.0A/C CENTRAL UNIT LOAD -- HEATING0.0x1.00=0.0HEAT LOAD SUBTOTAL=0.00APPLIED HEAT@65% VS COOL LARGEST KVA LOAD=0.00MOTOR LOADMOTORS12.4x1.00=12.4LARGEST MOTOR6.2x0.25=1.6LARGEST MOTOR LOAD @ 125% + REST @ 100% KVA LOAD=13.95MISC. CONTINUOUS LOADMISC. CONTINUOUS LOAD0.0x1.25=0.0CONTINUOUS KVA LOAD=0.00MISC. NON-CONTINUOUS LOADMISC. NON-CONTINUOUS LOAD0.0x1.00=0.0NON-CONTINUOUS KVA LOAD=0.00MISC. INTERMITTENT LOADMISC. INTERMITTENT LOAD0.5x0.00=0.0MAX INTERMITTENT LOAD0.5x1.25=0.6INTERMITTENT KVA LOAD=0.63PANELBOARD SERVICE SIZE CALCULATIONTOTAL KVA LOAD=15.33TOTAL AMPS=63.85NEC ART. 220 PART III DWELLING LOAD CALCPANEL:"C" GENERAL HOUSE PWR. (2)VOLTAGE VLL240VOLTAGE VLN120PHASE1GENERAL LOAD DESCRIPTION KVADFTOTALGENERAL LOADLIGHTING11.9x1.00=11.9SMALL APPLIANCE3.0x1.00=3.0WASHER0.0x1.00=0.0SUBTOTAL=14.88FIRST 3 KVA @ 100%3.0x1.00=3.0REMAINDER KVA @ 35%11.9x0.35=4.2REMAINDER KVA @ 25%0.0x0.25=0.0GENERAL KVA LOAD=7.16NON DWELLING RECEPTACLE LOADRECEPTACLE0.0x1.00=0.0SUBTOTAL=0.00FIRST 10 KVA @ 100%0.0x1.00=0.0REMAINDER KVA @ 40%0.0x0.40=0.0RECEPTACLE KVA LOAD=0.00DRYER LOAD0DRYER0.0x1.00=0.0DRYER KVA LOAD=0.00FIXED APPLIANCE LOAD#FIXED APPLIANCE17.5x1.00=17.51WATER HEATER0.0x1.00=0.0SUBTOTAL=17.50#APPLIED DIVERSITY17.5x0.75=13.1APPLIANCE KVA LOAD=13.13COOKING APPLIANCE LOAD1COOKING COL A1.8x1.00=1.80COOKING COL B0.0x1.00=0.00COOKING COL C0.0x1.00=0.0COOKING KVA LOAD=1.80HVAC LOADCOOLA/C AIR HANDLER FANS3.3x1.00=3.3A/C -- FRESH AIR MAKE-UP0.0x1.00=0.0A/C CENTRAL UNIT LOAD -- COOL16.7x1.00=16.7LARGEST AC EQUIPMENT8.4x0.25=2.1LARGEST HVAC COOL LOAD @ 125% + REST @ 100% SUBTOTAL=22.06HEATA/C AIR HANDLER FANS3.3x1.00=3.3A/C AIR HANDLER HEAT STRIPS20.0x1.00=20.0A/C -- FRESH AIR MAKE-UP HEATING0.0x1.00=0.0A/C CENTRAL UNIT LOAD -- HEATING0.0x1.00=0.0HEAT LOAD SUBTOTAL=23.26APPLIED HEAT@65% VS COOL LARGEST KVA LOAD=22.06MOTOR LOADMOTORS3.0x1.00=3.0LARGEST MOTOR3.0x0.25=0.8LARGEST MOTOR LOAD @ 125% + REST @ 100% KVA LOAD=3.75MISC. CONTINUOUS LOADMISC. CONTINUOUS LOAD0.0x1.25=0.0CONTINUOUS KVA LOAD=0.00MISC. NON-CONTINUOUS LOADMISC. NON-CONTINUOUS LOAD0.0x1.00=0.0NON-CONTINUOUS KVA LOAD=0.00MISC. INTERMITTENT LOADMISC. INTERMITTENT LOAD0.0x0.00=0.0MAX INTERMITTENT LOAD0.0x1.25=0.0INTERMITTENT KVA LOAD=0.00PANELBOARD SERVICE SIZE CALCULATIONTOTAL KVA LOAD=47.89TOTAL AMPS=199.54NEC ART. 220 PART III DWELLING LOAD CALCPANEL:"B" GENERAL HOUSE PWR. (2)VOLTAGE VLL240VOLTAGE VLN120PHASE1GENERAL LOAD DESCRIPTION KVADFTOTALGENERAL LOADLIGHTING20.9x1.00=20.9SMALL APPLIANCE0.0x1.00=0.0WASHER1.5x1.00=1.5SUBTOTAL=22.44FIRST 3 KVA @ 100%3.0x1.00=3.0REMAINDER KVA @ 35%19.4x0.35=6.8REMAINDER KVA @ 25%0.0x0.25=0.0GENERAL KVA LOAD=9.80NON DWELLING RECEPTACLE LOADRECEPTACLE0.0x1.00=0.0SUBTOTAL=0.00FIRST 10 KVA @ 100%0.0x1.00=0.0REMAINDER KVA @ 40%0.0x0.40=0.0RECEPTACLE KVA LOAD=0.00DRYER LOAD1DRYER1.5x1.00=1.5DRYER KVA LOAD=1.50FIXED APPLIANCE LOAD11FIXED APPLIANCE11.1x1.00=11.10WATER HEATER0.0x1.00=0.0SUBTOTAL=11.1011APPLIED DIVERSITY11.1x0.75=8.3APPLIANCE KVA LOAD=8.33COOKING APPLIANCE LOAD1COOKING COL A11.0x1.00=11.00COOKING COL B0.0x1.00=0.00COOKING COL C0.0x1.00=0.0COOKING KVA LOAD=11.00HVAC LOADCOOLA/C AIR HANDLER FANS2.2x1.00=2.2A/C -- FRESH AIR MAKE-UP0.0x1.00=0.0A/C CENTRAL UNIT LOAD -- COOL11.0x1.00=11.0LARGEST AC EQUIPMENT8.4x0.25=2.1LARGEST HVAC COOL LOAD @ 125% + REST @ 100% SUBTOTAL=15.29HEATA/C AIR HANDLER FANS2.2x1.00=2.2A/C AIR HANDLER HEAT STRIPS10.0x1.00=10.0A/C -- FRESH AIR MAKE-UP HEATING0.0x1.00=0.0A/C CENTRAL UNIT LOAD -- HEATING0.0x1.00=0.0HEAT LOAD SUBTOTAL=12.21APPLIED HEAT@65% VS COOL LARGEST KVA LOAD=15.29MOTOR LOADMOTORS0.0x1.00=0.0LARGEST MOTOR0.0x0.25=0.0LARGEST MOTOR LOAD @ 125% + REST @ 100% KVA LOAD=0.00MISC. CONTINUOUS LOADMISC. CONTINUOUS LOAD0.0x1.25=0.0CONTINUOUS KVA LOAD=0.00MISC. NON-CONTINUOUS LOADMISC. NON-CONTINUOUS LOAD0.0x1.00=0.0NON-CONTINUOUS KVA LOAD=0.00MISC. INTERMITTENT LOADMISC. INTERMITTENT LOAD0.0x0.00=0.0MAX INTERMITTENT LOAD0.0x1.25=0.0INTERMITTENT KVA LOAD=0.00PANELBOARD SERVICE SIZE CALCULATIONTOTAL KVA LOAD=45.92TOTAL AMPS=191.32NEC ART. 220 PART III DWELLING LOAD CALCPANEL:"A" GENERAL HOUSE PWR. (2)VOLTAGE VLL240VOLTAGE VLN120PHASE1GENERAL LOAD DESCRIPTION KVADFTOTALGENERAL LOADLIGHTING23.2x1.00=23.2SMALL APPLIANCE0.0x1.00=0.0WASHER1.5x1.00=1.5SUBTOTAL=24.72FIRST 3 KVA @ 100%3.0x1.00=3.0REMAINDER KVA @ 35%21.7x0.35=7.6REMAINDER KVA @ 25%0.0x0.25=0.0GENERAL KVA LOAD=10.60NON DWELLING RECEPTACLE LOADRECEPTACLE0.0x1.00=0.0SUBTOTAL=0.00FIRST 10 KVA @ 100%0.0x1.00=0.0REMAINDER KVA @ 40%0.0x0.40=0.0RECEPTACLE KVA LOAD=0.00DRYER LOAD1DRYER1.5x1.00=1.5DRYER KVA LOAD=1.50FIXED APPLIANCE LOAD13FIXED APPLIANCE18.2x1.00=18.20WATER HEATER0.0x1.00=0.0SUBTOTAL=18.2013APPLIED DIVERSITY18.2x0.75=13.7APPLIANCE KVA LOAD=13.65COOKING APPLIANCE LOAD0COOKING COL A0.0x1.00=0.00COOKING COL B0.0x1.00=0.00COOKING COL C0.0x1.00=0.0COOKING KVA LOAD=0.00HVAC LOADCOOLA/C AIR HANDLER FANS1.6x1.00=1.6A/C -- FRESH AIR MAKE-UP0.0x1.00=0.0A/C CENTRAL UNIT LOAD -- COOL6.9x1.00=6.9LARGEST AC EQUIPMENT6.9x0.25=1.7LARGEST HVAC COOL LOAD @ 125% + REST @ 100% SUBTOTAL=10.24HEATA/C AIR HANDLER FANS1.6x1.00=1.6A/C AIR HANDLER HEAT STRIPS10.0x1.00=10.0A/C -- FRESH AIR MAKE-UP HEATING0.0x1.00=0.0A/C CENTRAL UNIT LOAD -- HEATING0.0x1.00=0.0HEAT LOAD SUBTOTAL=11.63APPLIED HEAT@65% VS COOL LARGEST KVA LOAD=10.24MOTOR LOADMOTORS11.0x1.00=11.0LARGEST MOTOR0.0x0.25=0.0LARGEST MOTOR LOAD @ 125% + REST @ 100% KVA LOAD=11.00MISC. CONTINUOUS LOADMISC. CONTINUOUS LOAD0.0x1.25=0.0CONTINUOUS KVA LOAD=0.00MISC. NON-CONTINUOUS LOADMISC. NON-CONTINUOUS LOAD0.0x1.00=0.0NON-CONTINUOUS KVA LOAD=0.00MISC. INTERMITTENT LOADMISC. INTERMITTENT LOAD0.0x0.00=0.0MAX INTERMITTENT LOAD0.0x1.25=0.0INTERMITTENT KVA LOAD=0.00PANELBOARD SERVICE SIZE CALCULATIONTOTAL KVA LOAD=46.99TOTAL AMPS=195.81E103SUB PANEL POWER CALCULATIONS00INITIAL ISSUEJWLE09.24.21PERMIT SET 09.24.21 JOHN LANGFORD, FL#69962A1SUB-PANEL POWERCALCULATIONS ELEVATORUPUP 6 CAR GARAGEMUD ROOMFOYERCOVERED ENTRYSTORAGEMAINT ACCESS AREAPIPE / PWR CONNECTMAINT ACCESS AREAPIPE / PWR CONNECTMAINT ACCESS AREAPIPE / PWR CONNECTMAINT ACCESS AREAPIPE / PWR CONNECTC-23CLNG/GARAGEOPENERGFIC-19,21ELEV. EQUIPMENT2P6060HALLWAY A-35A-35A-35A-35A-35A-36A-36A-36A-36A-36A-36A-36A-36A-33+48"GFISP C-27GWHGFI C-28REC. PUMPA-32,34CAR CHARGERA-33+48"GFI A-33+48"GFI GFI A-33+48"GFIA-33+48"GFI A-33+48"A-39A-37A-37A-39A-37A-39GFI/WP A-38GFI/WPA-38GFI/WPA-38GFI/WPA-38GFI/WPA-38GFI/WPA-38B-06,08CU 2-22P5050(3R)C-02,04CU 2-12P5050(3R)C-06,08CU 3-12P5050(3R)A-02,04CU 3-22P4040(3R)PNL'C'PNL'B'PNL'A'MDPPNL'P'B-01,03AHU 1-12P1515METERATSB-02,04CU 1-12P3030(3R)PULLBOXPULLBOXA-35LEGENDTEF##SIGNLE RECEPTACLEDUPLEX RECEPTACLEHIDDEN DUPLEX RECEPTACLEGROUND FAULT INTERRUPTORGROUND FAULT INTERRUPTOR(WATER PROOF)1/2 SWITCH - DUPLEX RECEPTACLEFLOOR OUTLETQUAD RECEPTACLE240 VOLT RECEPTACLESWITCHSWITCH, 3-WAYSWITCH, 4-WAYSWITCH, DIMMER/RHEOSTATSWITCH, WATERPROOFSWITCH, MOTION SENSORTHERMOSTATLOW VOLTAGE CNTRL. SWITCHGARAGE DOOR OPENERJUNCTION BOX FOR FUTURE CONNECTIONEXHAUST FANDOORBELL CHIMESSPEAKERELECTRICAL PANELELECTRICAL METERFUSE DISCONNECTSPSPARK POWERCABLETELEPHONE/DATA PORTTELEVISION JACKS S S S SS SMOKE/CARBON MONOXIDE DETECTORCABLE TO ALTERNATE LEVELJGFIGFI/WPFLSD/CMSPE201POWER FLOOR PLAN - LOWER LEVELPLANNORTH00INITIAL ISSUEJWLE09.24.21PERMIT SET 09.24.21 JOHN LANGFORD, FL#69962POWER PLANLOWER LEVEL 48" RANGEELEV.REF.FR.SPAPOOLSUNSHELFDN WETBARDNUPLINEAR FIRE PITUTILITYCOVERED TERRACECOVERED TERRACEPANTRYBEDROOM #2WICPWDRBATHCABANACLUBROOMGREAT ROOMKITCHENDININGOUTDOOR LIVINGPOOL TERRACESTOR.SLIDING DOORSLIDING DOORSLIDING DOOR SLIDING DOOR SLIDING DOORHALLWAY SLIDING DOOR B-05,07AHU 2-22P6060B-26B-26C-26/VERIFYFLB-11B-11B-11B-11B-11FLFLB-11/VERIFYB-11/VERIFYB-11+52"/VERIFYB-12+42"GFIB-12+42"GFIB-12+42"GFIB-26B-29B-29/VERIFYFL B-29B-26B-29B-29B-29GFIB-12+42"GFIB-31+42"GFI B-31+42"GFI GFIGFIGFI B-31+42"B-31+42"B-31-6"CNTR.C-22UC WINEC-20UC ICEB-30UC DISP.C-19,21FCU WINE2P1515SPB-28SPK. PWR./FIREPLACESPB-27SPK. PWR./FIREPLACEB-31C-26C-26C-26/VERIFYFL C-26/VERIFYFL C-26SPB-22SPK. PWR./FIREPLACEB-21B-21B-21GFI GFI GFI GFI GFI B-20+42"B-18+42"B-20+42"B-18+42"B-20+42"C-13UC ICEC-122 DRWBEVERAGEB-17,19DBL. OVENC-11FREEZERC-10REF.GFIB-18+42"GFIB-18+42"GFIB-20+42"B-18+42"GFIC-17+42"GFIB-20+42"GFIC-18+42"GFIGFI B-20+42"GFIB-18+42"SPC-14GAS RANGEC-15HOODB-24UC DWB-25UC DWB-23UC DISP.B-26B-14WASHERB-13GAS DRYERSPGFIGFI B-16+42"B-16+42"B-26SPA-28SPK. PWR./FIREPITGFI/WPGFI/WPGFI/WP GFI/WP GFI/WP A-27A-27A-27A-27A-27SPA-30SPK. PWR./BBQA-31HOODGFI/WPA-29+42"GFI/WPA-29GFI/WPA-29B-32MOT.SHADESJB-32MOT.SHADESJB-32MOT.SHADESJB-32MOT.SHADESJB-32MOT.SHADESJJB-32MOT.SHADESJB-33MOT.SHADESJB-33MOT.SHADESJB-33MOT.SHADESJB-33MOT.SHADESJB-33MOT.SHADESJB-33MOT.SHADESA-26ROLL DOWNSCREENJA-26ROLL DOWNSCREENJA-26ROLL DOWNSCREENJC-01,03AHU 2-12P6060B-09DHJB-10CDJC-26+60"/VERIFYB-29+60"/VERIFYB-21B-21B-29JB-32MOT.SHADESB-21/VERIFYFLB-31-6"CNTR.LEGENDTEF##SIGNLE RECEPTACLEDUPLEX RECEPTACLEHIDDEN DUPLEX RECEPTACLEGROUND FAULT INTERRUPTORGROUND FAULT INTERRUPTOR(WATER PROOF)1/2 SWITCH - DUPLEX RECEPTACLEFLOOR OUTLETQUAD RECEPTACLE240 VOLT RECEPTACLESWITCHSWITCH, 3-WAYSWITCH, 4-WAYSWITCH, DIMMER/RHEOSTATSWITCH, WATERPROOFSWITCH, MOTION SENSORTHERMOSTATLOW VOLTAGE CNTRL. SWITCHGARAGE DOOR OPENERJUNCTION BOX FOR FUTURE CONNECTIONEXHAUST FANDOORBELL CHIMESSPEAKERELECTRICAL PANELELECTRICAL METERFUSE DISCONNECTSPSPARK POWERCABLETELEPHONE/DATA PORTTELEVISION JACKS S S S SS SMOKE/CARBON MONOXIDE DETECTORCABLE TO ALTERNATE LEVELJGFIGFI/WPFLSD/CMSPE202POWER FLOOR PLAN - MAIN LEVELPLANNORTH00INITIAL ISSUEJWLE09.24.21PERMIT SET 09.24.21 JOHN LANGFORD, FL#69962POWER PLANMAIN LEVEL LEGENDTEF##SIGNLE RECEPTACLEDUPLEX RECEPTACLEHIDDEN DUPLEX RECEPTACLEGROUND FAULT INTERRUPTORGROUND FAULT INTERRUPTOR(WATER PROOF)1/2 SWITCH - DUPLEX RECEPTACLEFLOOR OUTLETQUAD RECEPTACLE240 VOLT RECEPTACLESWITCHSWITCH, 3-WAYSWITCH, 4-WAYSWITCH, DIMMER/RHEOSTATSWITCH, WATERPROOFSWITCH, MOTION SENSORTHERMOSTATLOW VOLTAGE CNTRL. SWITCHGARAGE DOOR OPENERJUNCTION BOX FOR FUTURE CONNECTIONEXHAUST FANDOORBELL CHIMESSPEAKERELECTRICAL PANELELECTRICAL METERFUSE DISCONNECTSPSPARK POWERCABLETELEPHONE/DATA PORTTELEVISION JACKS S S S SS SMOKE/CARBON MONOXIDE DETECTORCABLE TO ALTERNATE LEVELJGFIGFI/WPFLSD/CMSPHBDNMECH.CLMECH.MASTER CLOSETBEDROOM #3BATHWICMASTER BEDROOMLOUNGESUN TERRACECOVERED TERRACEBATHOFFICE/WORKOUTMASTER BATHSUN TERRACECOVERED TERRACECOVERED TERRACESUN TERRACELAUNDRYSUN TERRACESLIDING DOOR SLIDING DOORSLIDING DOOR SLIDING DOOR SLIDING DOORSLIDING DOORSLIDING DOOR HALLWAYHALLWAYHALLWAYA-07+42"GFI A-07+42"GFIA-19+42"GFIA-01,03AHU 3-22P6060C-05,07AHU 3-12P6060A-07+42"GFI GFI C-25+42"GFIC-25+42"GFIGFIC-25+42"C-25+42"A-10WHIRLPOOLJA-09,11STEAM SHOWER2P3030GFIA-15+42"GFIA-15+42"A-13WASHERA-12GAS DRYERSPC-24FLOOR/VERIFYA-16SPK.PWR./FIREPLACESPA-17+60"/VERIFYA-06+52"/VERIFYA-19CLNG. MNT./VERIFYC-09UC REF.A-21COFFEE MKR.GFIA-18TREADMILL/VERIFYFL A-23MOT.SHADESJA-23MOT.SHADESJA-24MOT.SHADESJA-24MOT.SHADESJA-24MOT.SHADESJA-24MOT.SHADESJA-24MOT.SHADESJA-23MOT.SHADESJJA-23MOT.SHADESA-17/VERIFYFL A-22GFI/WP A-22GFI/WPA-22GFI/WPA-22GFI/WPA-22GFI/WPA-22GFI/WPA-22GFI/WP A-22GFI/WPA-05A-05A-06A-06A-06A-06A-06A-06A-20UC DISP.A-19A-19/VERIFYFL A-19A-19A-05A-05A-05A-08C-24C-24C-24C-24C-24C-24A-08A-08A-08A-08A-17BUILT-INA-17JA-25MOT.SCREENJA-25MOT.SCREENE203POWER FLOOR PLAN - UPPER LEVELPLANNORTH00INITIAL ISSUEJWLE09.24.21PERMIT SET 09.24.21 JOHN LANGFORD, FL#69962POWER PLANUPPER LEVEL ELEVATORUPUP L1L3L4L3L1L1L4L4L6L6L6L6L6L6L6L66 CAR GARAGEMUD ROOMFOYERCOVERED ENTRYSTORAGESD/CMMAINT ACCESS AREAPIPE / PWR CONNECTMAINT ACCESS AREAPIPE / PWR CONNECTMAINT ACCESS AREAPIPE / PWR CONNECTMAINT ACCESS AREAPIPE / PWR CONNECTGFIFROM MAINLEVEL LIGHTS &SWITCHT.C.CONTROLLEDT.C.CONTROLLEDSSSS STO UPPER LEVELLIGHTS & SWITCHS TO UPPER LEVELLIGHT & SWITCHSSSSSSSSSS SSSS CEILING MOUNTED FIXTUREWALL MOUNTED FIXTUREJ BOX w/OPT. FAN/LIGHTDOOR JAMB SWITCHREC'D ADJUST. FIXTUREPULL CORD FIXTUREVAPOR PROOF RECESSEDRECESSED LIGHT FIXTUREFLOURESCENT FIXTUREINLINE EXHAUST FANFLOOD/SECURITY LIGHTSUNDER CABINET FIXTUREEXHAUST FANPCVPEXF IEXF LIGHTING SYMBOL LEGENDVERIFY EXACT LOCATIONS OF ALL FIXTURES WITH ARCHITECTURAL OR IDDRAWINGS.E301POWER LIGHTING PLAN - LOWER LEVELPLANNORTH00INITIAL ISSUEJWLE09.24.21PERMIT SET 09.24.21 JOHN LANGFORD, FL#69962POWER LIGHTINGPLANLOWER LEVEL 48" RANGEELEV.REF.FR.SPAPOOLSUNSHELFDN WETBARDNUPLINEAR FIRE PITL2L2L2L2L5L5L5L5L5L5L5L2L6L6L6L6L6L6L6L6L6L6L6L6L2L1L1L1L1L1L1L1L1L1L1L1L1L1L1L1L1L1L1L1L1L1L1L1L1L1L1L1L1L1L1L1L1L1EXFEXFEXFUTILITYCOVERED TERRACECOVERED TERRACEPANTRYBEDROOM #2WICPWDRBATHCABANACLUBROOMGREAT ROOMKITCHENDININGOUTDOOR LIVINGPOOL TERRACESTOR.SD/CMSD/CMTO UPPER LEVELLIGHT & SWITCHTO UPPERLEVELSWITCHS SSSTO UPPER LEVELLIGHT & SWITCHSSS SSSSSSSS ST.C.CONTROLLEDT.C.CONTROLLEDS S S SS SSSSSSSSSSS S SSS S S S SSS S S S S S S SSS S S S S SSSSSSST.C.CONTROLLEDT.C.CONTROLLEDSSSFROM LOWERLEVEL SWITCHCEILING MOUNTED FIXTUREWALL MOUNTED FIXTUREJ BOX w/OPT. FAN/LIGHTDOOR JAMB SWITCHREC'D ADJUST. FIXTUREPULL CORD FIXTUREVAPOR PROOF RECESSEDRECESSED LIGHT FIXTUREFLOURESCENT FIXTUREINLINE EXHAUST FANFLOOD/SECURITY LIGHTSUNDER CABINET FIXTUREEXHAUST FANPCVPEXF IEXF LIGHTING SYMBOL LEGENDVERIFY EXACT LOCATIONS OF ALL FIXTURES WITH ARCHITECTURAL OR IDDRAWINGS.E302POWER LIGHTING PLAN - MAIN LEVELPLANNORTH00INITIAL ISSUEJWLE09.24.21PERMIT SET 09.24.21 JOHN LANGFORD, FL#69962POWER LIGHTINGPLANMAIN LEVEL HBDNMECH.CLL3L3L1L1L1L1L1L2L3L2L2L2L2L6L6L6L6L6L6L2EXFEXFEXFMECH.MASTER CLOSETBEDROOM #3BATHWICMASTER BEDROOMLOUNGESUN TERRACECOVERED TERRACEBATHOFFICE/WORKOUTMASTER BATHSUN TERRACECOVERED TERRACECOVERED TERRACESUN TERRACELAUNDRYSUN TERRACESD/CMSD/CMSD/CMSD/CMSD/CMSD/CMSD/CMSSSSSSSSSSSST.C.CONTROLLEDSJJSSSSSSSS S S SS ST.C.CONTROLLEDS SSSSSS S S S S S SSSSS SSSSSSSSSFROM MAIN LEVELSWITCHFROM MAIN LEVELSWITCHSSFROM STAIRLIGHTS & SWITCHFROM LOWERLEVELSWITCHSSCEILING MOUNTED FIXTUREWALL MOUNTED FIXTUREJ BOX w/OPT. FAN/LIGHTDOOR JAMB SWITCHREC'D ADJUST. FIXTUREPULL CORD FIXTUREVAPOR PROOF RECESSEDRECESSED LIGHT FIXTUREFLOURESCENT FIXTUREINLINE EXHAUST FANFLOOD/SECURITY LIGHTSUNDER CABINET FIXTUREEXHAUST FANPCVPEXF IEXF LIGHTING SYMBOL LEGENDVERIFY EXACT LOCATIONS OF ALL FIXTURES WITH ARCHITECTURAL OR IDDRAWINGS.E303POWER LIGHTING PLAN - UPPER LEVELPLANNORTH00INITIAL ISSUEJWLE09.24.21PERMIT SET 09.24.21 JOHN LANGFORD, FL#69962POWER LIGHTINGPLANUPPER LEVEL