HomeMy WebLinkAboutAPPROVED REVISION, ENERGY LOT 33FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name:
KHOV-EMERALD
Builder Name: KHOVNANAIN HOMES
Street:
5117 ARMINA PL.
Permit Office:
City, State, Zip:
FORT PIERCE, FL,
Permit Number:
Owner:
EMERALD MODEL LOT 33 @ WATERSTONE
Jurisdiction:
Design Location:
FL, Fort Pierce
County: St. Lucie (Florida Gimate Zone 2 )
1. New construction or existing
New (From Plans)
10. Wall TypeV508.8 sgft.)
Insulation
Area
2. Single family or multipla family
Detached
a. Frame - Wood, Exterior
R=11.0
1180.70 ft2
3. Number of units, if multiple family
1
b. Concrete Biock - Int Insul, Exterior
R=4.1
973.39 ft2
c. Frame - Wood, Adjacent
R=11.0
354.67 ft2
4. Number of Bedrooms
5
d. NIA
R=
ft2
5. Is this a worst case?
No
11. Ceiling Types (1354.0 sgft.)
Insulation
Area
a. Under Attic (Vented)
R=30.0
1354.00 ft2
6. Conditioned floor area above grade (ft2)
2321
b. NIA
R=
ft2
Conditioned floor area below grade (ft2)
0
c. NIA
R=
ft2
7. Winoowst154.0 sgfr.) Description
Area
12. Ducts
R ft2
a. U-Factor Dbl, U=0.30
152-00 ft2
a. Sup: Attic, Ret: HALL LOFT, AH: HALL LOFT
6 250
SHGC: SHGC=0.28
+;
b. U-Factor: Dbl, U=0.55
42.00 ft2
13. Cooling systems
kBtulhr
Efficiency
SHGC: SHGC=0.34
l
a. Central Unit
46.5 SEER:16.00
c. U-Factor_ NIA
ft2
S!-1GC:
Area lYeightad Average Overhang Depth:
3.165 ft.
14. Heating systems
kBtulhr
Efficiency
Area Weighted Average SHGC:
0.293
a. Electric Strip Heat
32.0
COP:1.00
$. Skylights
Area
c. U-Factor:(AVG) N/A
ft2
15. Hot water systems
SHGC(AVG): NIA
a. Electric
Cap:
50 gallons
9. Floe � Types (1354.1 sgft.)
Insulation
Area
EF: 0.950
a. S.a.,-Dn-Grape Edge Insulation
R=0.0
968.10 ft2
b. Conservation features
b. Rais& ! F*w
R=11.0
386.00 ft2
None
c. N.;a.
R=
ft2
16. Credits
Pstat
Glass/Floor Area: 0.084
Total Proposed Modified Loads: 70.47
Total Baseline _oads: 71.88
I hereby certify that the plans and specifications covered by
this ca cwatian are in compliance wit the Florida /En7y,
Cade.
PREPh ;EC I3`1 :
DATE:
I hereoy certify teat this building, as designed, is in compliance
with the Florida Energy Code.
O1N1�Ei�,'AGEI
DA--
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
BUILDING OFFICIAL:
DATE:
a , ;R
- Cc,.- )Ilwnce requires cerfi;icat:on by the air handler unit manL.facturer that the air handler enclosure qualifies as
ce; .;-'.ed factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
6/15.2021 3A4 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title-
KHOV-EMERALD
Bedrooms: 5
Address Type:
Street Address
Building Type:
User
Conditioned Area: 2321
Lot #
Owner Name.
EMERALD MODEL LOT 33
Total Stories: 2
Block/Subdivision:
# of Unirs:
1
Worst Case: No
PlatBook:
Builder Name:
KHOVNANAIN HOMES
Rotate Angle: 0
Street:
5117 ARMINA PL
Permit Office:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State,
Zip:
FORT PIERCE,
Family Type:
Detached
FL
New;Existing:
New (From Plans)
Comment:
CLIMATE
/
V
Design Temp
Int Design Temp Heating Resign Daily Temp
Design
Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree
Days
Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
II
1
1
Entire House
2321
19341.6
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated;
1
XTRA SUITE
144
1267.2 No
2
5
1
No
Yes
Yes
); S"TE BATH
60
52B No
0
1
No
Yes
Yes
3
=DYER
133
1173 No
0
1
No
Yes
Yes
4
GRT DIN KITCHEN
630
5544 No
1
1
No
Yes
Yes
5
3ED 4
' 74
1392 No
1
1
No
Yes
Yes
6
3ED 3
167
1334 No
1
1
No
Yes
Yes
7
3ED 2
162
1296 No
1
1
No
Yes
Yes
8
HALL _OFT
350
2800 No
0
1
No
Yes
Yes
9
_AUNDRY
48
384 No
0
1
No
Yes
Yes
110
:.IASTER SUITE
224
1792 No
2
1
No
Yes
Yes
11
^.AST WIC
6.0
476 No
0
1
No
Yes
Yes
2
1�11AST=R BATH
104
82,2 No
0
1
No
Yes
Yes
13
9ALL BATH
65
5,18 No
0
1
No
Yes
Yes
FLOORS
#
Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab
-On -Grade Edge Insulatio
EXTRA
SUITE 24 ft 0
144.8 ft2
----
0 1
0
2 Slal,-On-parade
Eage lnsulatio
EX SUITE
3ATH 6 ft 0
60 ft2
3 afar-"n-3rade
Ecge lnsulatio
FOYER 20.5 ft 0
133.3 ft2
_---
1 n
n
4 Slar-On-Grade Edge Insulatio GRT D1N KiTCHE 89 ft 0 630 ft2 ---- 0.5 0.5
6115;2021 3:44 PM EnergyGaugeS USA 7.0.00 - RaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 6
FORM R405-2020
VPUT SUMMARY CHECKLIST REPORT
Floor Tyr
5 Raised Floor
6 Raised Floor
7 Raised Floor
1
V rr Type
V # Type
Full attic
FLOORS
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
BED 4
---- ----
174 ft2
11
0 0 1
BED 3
___- --__
167 ft2
11
0 0 1
HALL LOFT
-_-- ----
45 ft2
11
0 0 1
ROOF
Roof Gable Roof
Rad
Solar SA Emitt
Emitt Deck Pitch
Materials
Area Area Color
Barr
Absor. Tested
Tested Insul. (deg)
Composition shingles 1466 ft2 0 ft2 Medium N 0.9 No 0.9 No 0 22.62
A T TIC
Ventilation Vent Ratio (1 in) Area RBS IRCC
Vented 150
CEILING
1353 ft2 N N
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac.
Truss Type
i
Under Attic (Vented) BED 4
30
Blown
174 ft2
01
Wood
III
2
Under Attic (Vented) BED 3
30
Blown
167 ft2
0-1
Wood
3
Under Attic (Vented) BED 2
30
Blown
162 ft2
0.1
Wood
4
Under Attic Vented) HALL LOFT
30
Blown
350 ft2
0.1
Wood
5
Under Attic {Vented) LAUNDRY
30
Blown
48 ft2
0.1
Wood
6
Under Attic (Vented) MASTER SUITE
30
Blown
224 ft2
0.1
Wood
i
Under Attic (Venred) MAST WIC
30
Blown
60 ft2
0.1
Wood
8
Under Attic (Vented) MASTER BATH
30
Blown
104 ft2
0.1
Wood
9
Under Attic (Vented) HALL BATH
30
Blown
65 ftz
0.1
Wood
WALLS
/
Adjacent _ Cavity
SpaceFt
Width
Height
Sheathing Framing Solnr ar
Below
��4xat-
Ta. i
'f}
In
A
o
9
E
E2-ie- or Co,-cr=`.s Block - Int InSE YTRA SUIT
4A
10
8 9
4
99.6 ft2
0
0
0.5
0
c
3
cxici c r Colin-,4 BiocK - Iht InsEX T RA SUIT
4.1
11
8 10
0
116.7 ft2
0
0
0.5
0
- 3
S
Exterior Concrete Block - lnt InsEX SUITE BA
4A
5
5 10
0
54.2 ft2
0
0
0.5
0
4
E
Extar;or Concrete Block - Int Insul FOYER
4.1
6
9 9
4
63.0 ft2
0
0
0.5
0
5
A
Exrer;or Connate Block - Int InsGRT DIN KIT
4.1
17
5 9
4
162.6 ft2
0
0
0.5
0
- 6
5
Exterior Concrete Block - Int InsGRT DIN KIT
4.1
16
2 10
0
161.7 ft2
0
0
0.5
0
- 7
W
Exter.or Concrete Block - Int InsGRT DIN KIT
4.1
33
10 9
4
315.8 ft2
0
0
0.5
0
6
iv
Exteriot Frame - Wood BED 4
11
13
8 8
10
120.7 ft2
0
0
0.5
0
9
_
Exterior Frame - Wood BED 4
11
10
11 8
10
96.4 ft2
0
0
0.5
0
10
E
Exienor Frame - Wood eED 3
11
10
11 8
10
96.4 ft2
0
0
0.5
0
11
E
Exter,or Frame - Wood BED 2
11
10
11 8
10
95.4 ft2
0
0
0.5
0
12
S
Exterior Frame - Wood BED 2
11
12
3 8
10
108.2 ft2
0
0
0.5
0 i
z 13
N
Exterior Frame - Wood HALL LOFT
11
7
3 8
10
64.0 ft2
0
0
0.5
0
6/15.+2021 3:44 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 6
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
WALLS
nwt
Adjacent
Tr) k tall Typea
Space Cavity Width
Height
Sheathing Framing
Solar Below
14 S
Exterior
Frame - Wood
HALL LOFT 11 12 9
8 10
112.6 ft2
0
0
0.5
0
i 5 ,V
Exterior
Frame - Wood
MASTER SUl 1 1 13 2
8 10
116.3 ft2
0
0
0.5
0
16 W
Exterior
Frame - Wood
MASTER SUl 11 14 7
8 10
128.8 ft2
0
0
0.5
0
17 W
Exterior
Frame - Wood
MASTER BA 11 11 10
8 10
104.5 ft2
0
0
0.5
0
-18 S
Exterior
Frame - Wood
HALL BATH 11 10 0
8 10
88.3 ft2
0
0
0.5
0
-19 W
Exterior
Frame - Wood
HALL BATH 11 5 5
8 10
47.8 ft2
0
0
0.5
0
20 W
Garage
Frame - Wood
GRT DIN KIT 11 38 0
9 4
354.7 ft2
0
0
0.5
0
DOORS
Ornt
Door Type
Space Storms
U-Value
Width
Height
Area
Ft
In
Ft In
Insulated
FOYER None
.39
3
4
6 8
22.2 ft2
2
E
Vuood
FOYER None
.39
3
4
6 8
22.2 ft2
WINDOW S
i'
Orlentai an shown is the entered, Pro osed orientation.
/
Wall
Overhang
V #
Ornt ID
Frame Panes
NFRC U-Factor SHGC ImpArea
Depth
p th
epa anon
Separation
Int Shade
Screening
1
E
1
Metal Double (Tinted)
Yes 0 3 0.28 N
15.0 ft2
1 ft 0 in
12 ft 0 in
None
None
2
VV
7
Meta; Double (Tinted)
Yes 0.3 0.28 N
32.0 ft2
1 ft 0 In
12 ft 0 in
None
None
3
VV
7
Metal Double (Tinted)
Yes 0.55 0.34 N
42.0 ft2
11 ft 0 in
1 ft 0 in
None
None
4
E
S
Metal Double (Tinted)
Yes 0.3 0.28 N
15.0 ft2
1 ft 0 in
1 ft 0 in
None
None
5
E
10
Metat Double (Tinted)
Yes 0.3 0.28 N
15.0 ft2
1 ft 0 in
1 ft 0 in
None
None
a
E
11
Metal Double (Tinted)
Yes 0.3 0.28 N
15.0 ft2
1 ft 0 in
1 ft 0 in
None
None
7
N
13
Metal Double (Tinted)
Yes 0.3 0.28 N
15.0 ft'
1 ft 0 in
1 ft 0 in
None
None
8
S
14
Metal Double (Tinted)
Yes 0.3 0.28 N
15.0 ft2
1 ft 0 in
1 ft 0 in
None
None
9
VV
16
Meta, Double (Tinted)
Yes 0.3 0.28 N
30.0 ft'
1 ft 0 in
1 ft 0 in
None
None
GARAGE
#
Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
386 ft- 386 ftz 64 ft
8 ft
INFILTRATION
# Scope
Method
SLP. CFM 50 ELA EgLA
ACH
ACH 50
1 Wriolehouse
Proposed ACH(50) .00037 2265.9 123.76 232.35
.1694
7
I
6/15/2021 3:44 PM EnergyGauge(D USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST
HEATING SYSTEM
#
System Type
Subtype Speed Efficiency Capacity
Block
Ducts
1
tea_
Electric Strip Heat/
-
None COPA 32 kBtu/hr
1
sys#1
COOLING SYSTEM
if
System Type
Subtype Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1
Central Unit/
Split Singl SEER: 16 46.5 kBtulhr cfm
0.74 1
sys#1
HOT WATER SYSTEM
#
Systern Type SubType
Location EF Cap Use SetPnt
Conservation
r
1
Electric None
Garage 0.95 60 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
V r -C'
Collector
Storage
Cori
r Company ,Name
System Model # Collector Model # Area
Volume
FEF
None None
ft2
DUCTS
-- Suply ---
---- Return ---- Air CFM 25 CFM25
HVAC #
Location R-Value Area
Location Area Leakage Type Handler TOT OUT
ON RLF
Heat Cool
1
Attic 6 250 ft2
HALL LOFT 1 ft2 Default Leakage HALL LOFT (Default) (Default?
1 1
TEMP--._ ATURES
Programable TharmosLat: Y
Ceiling Fans:
Cooling
He gar.
Feb
Feb
Mar
Mar
Apr
Aor
May
Ma
Jun
Jun
X Jul
Jul
X Aug
Au
X Sep
Se
Oct
Oet �
Nov
Nov
Dec
Ve, ,
Feb�.X
Mar
C� r
May
Jun
Jul
Aug
Sep
�xl Oct lx�
Nov
X Dec
Dec
Thenarostat SClIeCLI3e: HERS
2006 Reference
Hours
SchedCa Type
i
1
2
3
4
5
6
7
8
9 10
11
12
Coclina_ IWD)
AM
PM
78
78
78
78
78
78
78
78
80 80
80
80
80
80
78
78
78
78
78
78
78 78
7S
78
Coonng VVEr-,;
AM
76
78
78
78
78
78
78
78
78 78
78
78
PM
78
78
78
78
78
78
78
78
78 78
78
78
Heatirp •u:p,
AM
66
56
66
66
66
68
68
68
68 68
68
68
Pr,A
68
68
68
68
68
68
68
68
68 68
66
66
Heat'. ; lti'c �l^1i
66
66
66
66
66
68
68
68
68 68
68
68
P('=1
S9
68
68
68
68
68
68
63
68 68
66
66
MASS
? yGe
Area
Thickness
Furniture Fraction
Space
,aslsg_ft.
0 fF
0 ft
0.3
BED 2
Defa-, -1sc.` .
ftz
ft
0.3
BATH 2
ft2
ft
0.3
LAUNDRY
ft
0.3
KITCHEN
ft.
I
ft2
fr
0.3
GREAT ROOM
u_;..:5 •;aisq. t,
ft2
ft
0.3
WIC MASTER
ft
0.3
MASTER BATH
= Defauis,8 ;oslsq.il.
ft2
ft
0.3
TIOLET MASTER
61V3 2,)21 3:44 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 6
FORM R405-2020
Mass Type
De fau It{8 Ibsls.q.fi.
PUT SUMMARY CHECKLIST
MASS
Area Thickness Furniture Fraction Space
ftz ft 0.3 MASTER SUITE
6/15/2021 3:44 PM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index, the more efficient the home.
5117 ARMINA PL., FORT PIERCE, FL,
1. New construction or existing New (From Plans)
10. Wall Type and Insulation
Insulation Area
2. Single family or multiple family Detached
a. Frame - Wood, Exterior
R=11.0 1180.70 ft2
3. Number of units, if multiple family 1
b_ Concrete Biock - Int Insul, Exterior
R=4.1 973.39 ft2
c. Frame - Wood, Adjacent
R=11.0 354.67 ft2
4. Number of Bedrooms 5
d. NIA
R= ft2
5. Is this a worst case? No
11. Ceiling Type and insulation level
Insulation Area
a. Under Attic (Vented)
R=30.0 1354.00 ft2
6. Conditioned floor area (ft2) 2321
b. NIA
R= ft2
7. Windows- Description Area
c. NIA
R= ft2
a. U-Factor. Dbl, U=0.30 152.00 ft2
12. Ducts, location & insulation level
R ft2
SHGC: SHGC=0.28
a. Sup; Attic, Ret: HALL LOFT, AH: HALL LOFT 6 250
b_ U-Factor Dbl, U=0.55 42.00 ft2
SHGC: SHGC=0.34
13. Cooling systems
kBtulhr Efficiency
c. U-Factor: NIA ft2
a. Central Unit
46.6 SEER:16.00
SHGC:
d. U-Fac,cr NIA ft2
5 GC-
14. Heating systems
kBtulhr Efficiency
Are,. Weighted Average Overhang Depth: 3.165 ft.
a. Electric Strip Heat
32.0 COP:1.00
Area Waighted Average SHGC: 0.293
8. Skylights Description Area
15, Hot water systems
a. U-Factor(AVG.); NIA ft 2
a. Electric
Cap' S0 gallons
SHGCtiAVG): NIA
EF: 0.95
b. Conservation features
9. FioerTypes Insulation Area
None
a. Slab -On -Grade Edge Insulation R=0.0 968.10 ft2
b. Raised Floor R=11.0 386.00 ft2
Credits (Performance method)
Pstat
c. `h R= ft2
1 certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
S^
_
in this home before final inspection. Otherwise, a new EPL
Display Card will be completed`
=a
based on installed Code compliant features.
.r
Builder Signature:
- -
Date:
-
Address Gf New Home:
City/FL Zip:
'NOte: --h.i3 is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
c.-.servation, contact the Florida Building Commission's support staff.
-Label racjired by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
& 15t2021 3.45 PM EnergyGaugeO USA 7.0.00 - RaRe52020 FBC 7th Edition (2020) Compliant Software Page 1 of 1