Loading...
HomeMy WebLinkAboutAPPROVED REVISION, ENERGY LOT 33FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: KHOV-EMERALD Builder Name: KHOVNANAIN HOMES Street: 5117 ARMINA PL. Permit Office: City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: EMERALD MODEL LOT 33 @ WATERSTONE Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Gimate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall TypeV508.8 sgft.) Insulation Area 2. Single family or multipla family Detached a. Frame - Wood, Exterior R=11.0 1180.70 ft2 3. Number of units, if multiple family 1 b. Concrete Biock - Int Insul, Exterior R=4.1 973.39 ft2 c. Frame - Wood, Adjacent R=11.0 354.67 ft2 4. Number of Bedrooms 5 d. NIA R= ft2 5. Is this a worst case? No 11. Ceiling Types (1354.0 sgft.) Insulation Area a. Under Attic (Vented) R=30.0 1354.00 ft2 6. Conditioned floor area above grade (ft2) 2321 b. NIA R= ft2 Conditioned floor area below grade (ft2) 0 c. NIA R= ft2 7. Winoowst154.0 sgfr.) Description Area 12. Ducts R ft2 a. U-Factor Dbl, U=0.30 152-00 ft2 a. Sup: Attic, Ret: HALL LOFT, AH: HALL LOFT 6 250 SHGC: SHGC=0.28 +; b. U-Factor: Dbl, U=0.55 42.00 ft2 13. Cooling systems kBtulhr Efficiency SHGC: SHGC=0.34 l a. Central Unit 46.5 SEER:16.00 c. U-Factor_ NIA ft2 S!-1GC: Area lYeightad Average Overhang Depth: 3.165 ft. 14. Heating systems kBtulhr Efficiency Area Weighted Average SHGC: 0.293 a. Electric Strip Heat 32.0 COP:1.00 $. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): NIA a. Electric Cap: 50 gallons 9. Floe � Types (1354.1 sgft.) Insulation Area EF: 0.950 a. S.a.,-Dn-Grape Edge Insulation R=0.0 968.10 ft2 b. Conservation features b. Rais& ! F*w R=11.0 386.00 ft2 None c. N.;a. R= ft2 16. Credits Pstat Glass/Floor Area: 0.084 Total Proposed Modified Loads: 70.47 Total Baseline _oads: 71.88 I hereby certify that the plans and specifications covered by this ca cwatian are in compliance wit the Florida /En7y, Cade. PREPh ;EC I3`1 : DATE: I hereoy certify teat this building, as designed, is in compliance with the Florida Energy Code. O1N1�Ei�,'AGEI DA-- Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: a , ;R - Cc,.- )Ilwnce requires cerfi;icat:on by the air handler unit manL.facturer that the air handler enclosure qualifies as ce; .;-'.ed factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 6/15.2021 3A4 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title- KHOV-EMERALD Bedrooms: 5 Address Type: Street Address Building Type: User Conditioned Area: 2321 Lot # Owner Name. EMERALD MODEL LOT 33 Total Stories: 2 Block/Subdivision: # of Unirs: 1 Worst Case: No PlatBook: Builder Name: KHOVNANAIN HOMES Rotate Angle: 0 Street: 5117 ARMINA PL Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Detached FL New;Existing: New (From Plans) Comment: CLIMATE / V Design Temp Int Design Temp Heating Resign Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume II 1 1 Entire House 2321 19341.6 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated; 1 XTRA SUITE 144 1267.2 No 2 5 1 No Yes Yes ); S"TE BATH 60 52B No 0 1 No Yes Yes 3 =DYER 133 1173 No 0 1 No Yes Yes 4 GRT DIN KITCHEN 630 5544 No 1 1 No Yes Yes 5 3ED 4 ' 74 1392 No 1 1 No Yes Yes 6 3ED 3 167 1334 No 1 1 No Yes Yes 7 3ED 2 162 1296 No 1 1 No Yes Yes 8 HALL _OFT 350 2800 No 0 1 No Yes Yes 9 _AUNDRY 48 384 No 0 1 No Yes Yes 110 :.IASTER SUITE 224 1792 No 2 1 No Yes Yes 11 ^.AST WIC 6.0 476 No 0 1 No Yes Yes 2 1�11AST=R BATH 104 82,2 No 0 1 No Yes Yes 13 9ALL BATH 65 5,18 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio EXTRA SUITE 24 ft 0 144.8 ft2 ---- 0 1 0 2 Slal,-On-parade Eage lnsulatio EX SUITE 3ATH 6 ft 0 60 ft2 3 afar-"n-3rade Ecge lnsulatio FOYER 20.5 ft 0 133.3 ft2 _--- 1 n n 4 Slar-On-Grade Edge Insulatio GRT D1N KiTCHE 89 ft 0 630 ft2 ---- 0.5 0.5 6115;2021 3:44 PM EnergyGaugeS USA 7.0.00 - RaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 6 FORM R405-2020 VPUT SUMMARY CHECKLIST REPORT Floor Tyr 5 Raised Floor 6 Raised Floor 7 Raised Floor 1 V rr Type V # Type Full attic FLOORS Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet BED 4 ---- ---- 174 ft2 11 0 0 1 BED 3 ___- --__ 167 ft2 11 0 0 1 HALL LOFT -_-- ---- 45 ft2 11 0 0 1 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) Composition shingles 1466 ft2 0 ft2 Medium N 0.9 No 0.9 No 0 22.62 A T TIC Ventilation Vent Ratio (1 in) Area RBS IRCC Vented 150 CEILING 1353 ft2 N N # Ceiling Type Space R-Value Ins Type Area Framing Frac. Truss Type i Under Attic (Vented) BED 4 30 Blown 174 ft2 01 Wood III 2 Under Attic (Vented) BED 3 30 Blown 167 ft2 0-1 Wood 3 Under Attic (Vented) BED 2 30 Blown 162 ft2 0.1 Wood 4 Under Attic Vented) HALL LOFT 30 Blown 350 ft2 0.1 Wood 5 Under Attic {Vented) LAUNDRY 30 Blown 48 ft2 0.1 Wood 6 Under Attic (Vented) MASTER SUITE 30 Blown 224 ft2 0.1 Wood i Under Attic (Venred) MAST WIC 30 Blown 60 ft2 0.1 Wood 8 Under Attic (Vented) MASTER BATH 30 Blown 104 ft2 0.1 Wood 9 Under Attic (Vented) HALL BATH 30 Blown 65 ftz 0.1 Wood WALLS / Adjacent _ Cavity SpaceFt Width Height Sheathing Framing Solnr ar Below ��4xat- Ta. i 'f} In A o 9 E E2-ie- or Co,-cr=`.s Block - Int InSE YTRA SUIT 4A 10 8 9 4 99.6 ft2 0 0 0.5 0 c 3 cxici c r Colin-,4 BiocK - Iht InsEX T RA SUIT 4.1 11 8 10 0 116.7 ft2 0 0 0.5 0 - 3 S Exterior Concrete Block - lnt InsEX SUITE BA 4A 5 5 10 0 54.2 ft2 0 0 0.5 0 4 E Extar;or Concrete Block - Int Insul FOYER 4.1 6 9 9 4 63.0 ft2 0 0 0.5 0 5 A Exrer;or Connate Block - Int InsGRT DIN KIT 4.1 17 5 9 4 162.6 ft2 0 0 0.5 0 - 6 5 Exterior Concrete Block - Int InsGRT DIN KIT 4.1 16 2 10 0 161.7 ft2 0 0 0.5 0 - 7 W Exter.or Concrete Block - Int InsGRT DIN KIT 4.1 33 10 9 4 315.8 ft2 0 0 0.5 0 6 iv Exteriot Frame - Wood BED 4 11 13 8 8 10 120.7 ft2 0 0 0.5 0 9 _ Exterior Frame - Wood BED 4 11 10 11 8 10 96.4 ft2 0 0 0.5 0 10 E Exienor Frame - Wood eED 3 11 10 11 8 10 96.4 ft2 0 0 0.5 0 11 E Exter,or Frame - Wood BED 2 11 10 11 8 10 95.4 ft2 0 0 0.5 0 12 S Exterior Frame - Wood BED 2 11 12 3 8 10 108.2 ft2 0 0 0.5 0 i z 13 N Exterior Frame - Wood HALL LOFT 11 7 3 8 10 64.0 ft2 0 0 0.5 0 6/15.+2021 3:44 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS nwt Adjacent Tr) k tall Typea Space Cavity Width Height Sheathing Framing Solar Below 14 S Exterior Frame - Wood HALL LOFT 11 12 9 8 10 112.6 ft2 0 0 0.5 0 i 5 ,V Exterior Frame - Wood MASTER SUl 1 1 13 2 8 10 116.3 ft2 0 0 0.5 0 16 W Exterior Frame - Wood MASTER SUl 11 14 7 8 10 128.8 ft2 0 0 0.5 0 17 W Exterior Frame - Wood MASTER BA 11 11 10 8 10 104.5 ft2 0 0 0.5 0 -18 S Exterior Frame - Wood HALL BATH 11 10 0 8 10 88.3 ft2 0 0 0.5 0 -19 W Exterior Frame - Wood HALL BATH 11 5 5 8 10 47.8 ft2 0 0 0.5 0 20 W Garage Frame - Wood GRT DIN KIT 11 38 0 9 4 354.7 ft2 0 0 0.5 0 DOORS Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In Insulated FOYER None .39 3 4 6 8 22.2 ft2 2 E Vuood FOYER None .39 3 4 6 8 22.2 ft2 WINDOW S i' Orlentai an shown is the entered, Pro osed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC ImpArea Depth p th epa anon Separation Int Shade Screening 1 E 1 Metal Double (Tinted) Yes 0 3 0.28 N 15.0 ft2 1 ft 0 in 12 ft 0 in None None 2 VV 7 Meta; Double (Tinted) Yes 0.3 0.28 N 32.0 ft2 1 ft 0 In 12 ft 0 in None None 3 VV 7 Metal Double (Tinted) Yes 0.55 0.34 N 42.0 ft2 11 ft 0 in 1 ft 0 in None None 4 E S Metal Double (Tinted) Yes 0.3 0.28 N 15.0 ft2 1 ft 0 in 1 ft 0 in None None 5 E 10 Metat Double (Tinted) Yes 0.3 0.28 N 15.0 ft2 1 ft 0 in 1 ft 0 in None None a E 11 Metal Double (Tinted) Yes 0.3 0.28 N 15.0 ft2 1 ft 0 in 1 ft 0 in None None 7 N 13 Metal Double (Tinted) Yes 0.3 0.28 N 15.0 ft' 1 ft 0 in 1 ft 0 in None None 8 S 14 Metal Double (Tinted) Yes 0.3 0.28 N 15.0 ft2 1 ft 0 in 1 ft 0 in None None 9 VV 16 Meta, Double (Tinted) Yes 0.3 0.28 N 30.0 ft' 1 ft 0 in 1 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 386 ft- 386 ftz 64 ft 8 ft INFILTRATION # Scope Method SLP. CFM 50 ELA EgLA ACH ACH 50 1 Wriolehouse Proposed ACH(50) .00037 2265.9 123.76 232.35 .1694 7 I 6/15/2021 3:44 PM EnergyGauge(D USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 tea_ Electric Strip Heat/ - None COPA 32 kBtu/hr 1 sys#1 COOLING SYSTEM if System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 46.5 kBtulhr cfm 0.74 1 sys#1 HOT WATER SYSTEM # Systern Type SubType Location EF Cap Use SetPnt Conservation r 1 Electric None Garage 0.95 60 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM V r -C' Collector Storage Cori r Company ,Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS -- Suply --- ---- Return ---- Air CFM 25 CFM25 HVAC # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 250 ft2 HALL LOFT 1 ft2 Default Leakage HALL LOFT (Default) (Default? 1 1 TEMP--._ ATURES Programable TharmosLat: Y Ceiling Fans: Cooling He gar. Feb Feb Mar Mar Apr Aor May Ma Jun Jun X Jul Jul X Aug Au X Sep Se Oct Oet � Nov Nov Dec Ve, , Feb�.X Mar C� r May Jun Jul Aug Sep �xl Oct lx� Nov X Dec Dec Thenarostat SClIeCLI3e: HERS 2006 Reference Hours SchedCa Type i 1 2 3 4 5 6 7 8 9 10 11 12 Coclina_ IWD) AM PM 78 78 78 78 78 78 78 78 80 80 80 80 80 80 78 78 78 78 78 78 78 78 7S 78 Coonng VVEr-,; AM 76 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heatirp •u:p, AM 66 56 66 66 66 68 68 68 68 68 68 68 Pr,A 68 68 68 68 68 68 68 68 68 68 66 66 Heat'. ; lti'c �l^1i 66 66 66 66 66 68 68 68 68 68 68 68 P('=1 S9 68 68 68 68 68 68 63 68 68 66 66 MASS ? yGe Area Thickness Furniture Fraction Space ,aslsg_ft. 0 fF 0 ft 0.3 BED 2 Defa-, -1sc.` . ftz ft 0.3 BATH 2 ft2 ft 0.3 LAUNDRY ft 0.3 KITCHEN ft. I ft2 fr 0.3 GREAT ROOM u_;..:5 •;aisq. t, ft2 ft 0.3 WIC MASTER ft 0.3 MASTER BATH = Defauis,8 ;oslsq.il. ft2 ft 0.3 TIOLET MASTER 61V3 2,)21 3:44 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 6 FORM R405-2020 Mass Type De fau It{8 Ibsls.q.fi. PUT SUMMARY CHECKLIST MASS Area Thickness Furniture Fraction Space ftz ft 0.3 MASTER SUITE 6/15/2021 3:44 PM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. 5117 ARMINA PL., FORT PIERCE, FL, 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Frame - Wood, Exterior R=11.0 1180.70 ft2 3. Number of units, if multiple family 1 b_ Concrete Biock - Int Insul, Exterior R=4.1 973.39 ft2 c. Frame - Wood, Adjacent R=11.0 354.67 ft2 4. Number of Bedrooms 5 d. NIA R= ft2 5. Is this a worst case? No 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 1354.00 ft2 6. Conditioned floor area (ft2) 2321 b. NIA R= ft2 7. Windows- Description Area c. NIA R= ft2 a. U-Factor. Dbl, U=0.30 152.00 ft2 12. Ducts, location & insulation level R ft2 SHGC: SHGC=0.28 a. Sup; Attic, Ret: HALL LOFT, AH: HALL LOFT 6 250 b_ U-Factor Dbl, U=0.55 42.00 ft2 SHGC: SHGC=0.34 13. Cooling systems kBtulhr Efficiency c. U-Factor: NIA ft2 a. Central Unit 46.6 SEER:16.00 SHGC: d. U-Fac,cr NIA ft2 5 GC- 14. Heating systems kBtulhr Efficiency Are,. Weighted Average Overhang Depth: 3.165 ft. a. Electric Strip Heat 32.0 COP:1.00 Area Waighted Average SHGC: 0.293 8. Skylights Description Area 15, Hot water systems a. U-Factor(AVG.); NIA ft 2 a. Electric Cap' S0 gallons SHGCtiAVG): NIA EF: 0.95 b. Conservation features 9. FioerTypes Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 968.10 ft2 b. Raised Floor R=11.0 386.00 ft2 Credits (Performance method) Pstat c. `h R= ft2 1 certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) S^ _ in this home before final inspection. Otherwise, a new EPL Display Card will be completed` =a based on installed Code compliant features. .r Builder Signature: - - Date: - Address Gf New Home: City/FL Zip: 'NOte: --h.i3 is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, c.-.servation, contact the Florida Building Commission's support staff. -Label racjired by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. & 15t2021 3.45 PM EnergyGaugeO USA 7.0.00 - RaRe52020 FBC 7th Edition (2020) Compliant Software Page 1 of 1