HomeMy WebLinkAboutHeat Pump InformationkPILTRATEMPO
HEAT PUMP!
HIGH PERFORMANCE
HEAT PUMP
. .
i4
• 100% pure titanium heat exchanger assures corrosion -free performance
for extra long life
Mon
• LCO control board displays an intuitive menu -driven readout with easy
to follow full word messages no more codes
S o I a c 1;
f
PENTAINTAI
4�R
• AuloSet Rime clock over -ride) feature monitors water temperature
and turns the water circulation pump on and off as needed to maintain
-desired
pool temperatures
• Automatic defrost feature senses refrigerant temperature and prevents
freezing, allowing the beat pump to operate at
even tower temperatures
• Compatible with ALL automated control packages
• Long -life corrosion resistant plastic composite cabinet stands up to
severe climates and pool chemicals
• Emerson® Copeland Scroll® Compressor on 60 Hz, single phase models
• ETL listed for safe operation
• Thermostatic Expansion Valve ITXVI controls refrigerant flow for
Optimum efficiency and BTU output over awider operating range
• Highest efficiency available, meets or exceeds existing codes
ST.
r`ECO V Ei J - -
NO#joEfU Alit
and standards
UltraTemp Heat Pumps
• BTU and efficiency performance independently: certified by the
Air -Conditioning,
_ The industry's first heat pump charged with
Heating and Refrigeration Institute, AHRI
non -ozone depleting refrigerant, R410A.
Ordering Information
Pa" Model 80/80/800
BLACK LND BTU/C0P
MO
80/63/806•
BTU/Cop
50/63/8000
BTU/COP
Freq Breaker Wire Cin Ctn
(Hz). Size Phase Volt
(ampl size Oty. Wt. Dim.
460960 46093.0 70 75,006/5.8
70,000/5.7
50.00014.1 •
•60 40 1
460961 460931 .90 90,000/5.7
84,00D/5.5
60,000/4.0
10 230 1 230 33.5
60 50
460962 460932 lid 108,000/6.0
101,000/5.8
72.000/4.0
1 8 230 1 250 33.5
60 50
460.9.63 6094;_
nor `, 120 127,000/5.7
120.000/5.5
82,000/4,0
1 8 230 1 270 45.5
60 50 1__ R Tin I
460965
460935
120 H/C
127000 Heat/5 6
120,000/5.4
71.000 Cool/4.1
460959
460958
140 H/C
140.000 Heat/5.6
132,000/5:4
80,000 Cool/4.1
N/A
460936
901
85.00015.7
81.00015.4
460967
460937
120 C
12300/5.6
115.000/5.3
N/A
460938
1001
102;000/5.9
96,000/5.6
460929
466928
140C
140.000/5.8
132.000/5.6
• Rating outside the scope of ARI Standard 1160 lair temp. •F, / % relative
humidity/water temp •F.1
—Rating in accordance with ARI Standard 1160 fair temp. °F. / %relative
Iwmidily/water temp •F.l
82,000/4.0
60 50 1 8 230 1 278 45.5
85.000/4.0
60 50 1 8 230 1 320 34.5
56,000/4.0
50 30 3 10 380 1 250 33.5
81,000/4.0
60 50 3 8 230 1 280 45.5
67,000/4.0
50 50 1 8 230 1 280 41.5
86,ODO/4,0
60 50 3 8 230 1 320 45.5
Emerson°is a7egistered trademark of Emerson Electric Co. and Copeland
Scroll°isa
registered trademark of Emerson Climate Technologies, Inc.
Dimensions and Performance
GUM
�,..•
n
The AHRI Certifiedm Mark is applieq.only
to HVACR equipment and components that
have been independently tested to certify
manufacturers' performance claims are
accurate. Visit www.ahridirectory.org for a
complete list of certified products.
CEC indicates that Heat Pump has been evaluated
to California Tit(e-20, listed in the California
Energy Commission's ICEC) database of compliant
heat pumps, and certified to use on Residential
Swimming Pool Filtration Systems.
See pages 453-454 for replacement parts.
m
2
INSTALLATION AND LOCATION
�C UTIDN When pool equipment is located below the pool surface, a leak from any component can cause large scale water loss or flooding.
Pentair Water Pool and Spa, Inc. cannot be responsible for such water loss or flooding which may cause damage to property or
to the product. Avoid placing the heat pump in locations where it can cause damage by water or condensate leakage. If this is not possible, provide a
suitable drain pan to catch and divert any leakage.
Only a qualified service person should install the
UltmTemp® Heat Pump. Before installing this product,
refer to the Important Warning and Safety Instructions
on page I
Materials Needed for Installation
The following items are needed and are to be supplied
by the installer for all heat pump installations:
1. Plumbing connections (2-inch).
2. Level surface for proper drainage.
3. Suitable electrical supply line. See rating plate on
unit for electrical specifications. A junction box is not
needed at the heat pump; connections are made
inside of the heat pump electrical compartment
Conduit may be attached directly to the heat pump
jacket.
4. Electric cutout switch that will interrupt all power to
the unit. This switch must be within line of sight of
the heat pump. Check local codes for requirements.
5. Watertight conduit to run the electrical supply line.
Equipment Pad
Forproperdrainage ofcondensation and rainwater, place
the heat pump on a flat slightly pitched surface, such as
a concrete or fabricated slab (pad).
If possible, place the pad at the same level or slightly
higher than the filter system equipment pad.
Note: Be sure that the pad is pitched not more than 1 /4
in. per foot in any direction as needed for runoff.
Heat Pump Dimensions
MODELS DIMENSION "A"
70,90 33.5r (851 mm)
110, 120, 120C, 140C 45.5" (1156 mm)
120 H/C, 140,140 H/C
Drainage and Condensation
Condensation occurs from the evaporator coil while the
unit is running, and drains at a steady rate (usually three
to five gallons per hour), depending upon ambient air
temperature and humidity. The more humid the ambient
conditions, the more condensation will be produced.
The bottom of the unit acts as a tray to catch rainwater
and condensation. Keep the drain holes, located on the
bottom pan of the base of the unit, clear of debris.
Roof Run-off
Make sure the heat pump is not located where large
amounts of water may run-off from a roof into the unit.
Sharp sloping roofs without gutters will allow massive
amounts of rain water, mixed with debris from the roof
to be forced through the unit. A gutter or down spout
may be needed to protect the heat pump.
Lawn Sprinklers
Avoid placing lawn sprinkler near the heater -
they can spray water into the heater and void the
warranty. Be sure to direct any spraying water away
from the heater. Note the wind direction to be sure
water from sprinklers is not blown toward the heater.
Sprinkler heads can produce high water pressure and
spray at an angle, different from typical rain and humid
weather. Also, sprinklers connected to a well water
system can cause mineral build up on the evaporator
coils and electronics. Salt water can also be an issue if
located near the coast.
(114-0
— 30_T' —
(780 man)
-340—
(ON MM)
ULTRATEMP" Heat Pump Installation and User's Guide
3
Location and Clearances
All criteria given in the following sections reflect minimum
clearances. However, each installation must also be
evaluated, taking into account the prevailing local
conditions such as proximity and height of walls, and
proximity to public access areas.
The UltmTemp® Heat Pump must be placed to provide
clearances on all sides for maintenance and inspection.
1. At least 24 in. [610 mm] access must be available in
the front and 12 in. [305 mm] on all the other sides
of the heat pump for service and proper air flow.
(Manufacturer's recommendation).
Anchor Clamp Installation
2. If the heat pump is to be installed under a cover
or under a vertical overhang, the unit must have
a minimum of five (5) feet [1.52 m] clearance
from the top of the heat pump. (Manufacturer's
recommendation).
3. Install a minimum of five (5) feet [1.52 m] from the
inside wall of the pool or spa unless the heat pump
is separated from the pool or spa by a five (5)
foot [1.52 m] high solid fence or other permanent
barrier. Canadian installations require a minimum
of three (3) meters [9.84 ft] from pool water.
4. Install heat pump a minimum of 6 in. [153 mm] from
Heat Pump Location and Clearances
Installation of the anchor clamps is recommended in
all installations. Installation of the anchor clamps is
required in Florida (see Florida Building Code 301.13).
Anchor clamps- hold the heat pump to the equipment
pad in order to withstand high winds caused during
extreme weather (i.e. hurricanes).
To install the anchor clamps:
1. Be sure the heat pump is in its permanent location
on the equipment pad.
2. Place the clamps at the base of the heat pump in
the four (4) locations, shown in the image to the
right.
Note: Bolts and bolt anchors are not included with
the heat pump. The installer must provide 1/4" x
1-31W stainless steel anchor bolts and the appro-
priate size concrete anchor to mount the clamp to
the equipment pad. Be sure to check local codes.
3. Fit the hook of each clamp over the lip on the
base panel of the heat pump. The hook should fit
between the lip of the base panel and the evapo-
rator coil guard.
Heat
Cie
leat Pump
Clamps
Anchor Clamp Installation
ULTRATEMP° Heat Pump Installation and Users Guide
4
Anchor Clamp Installation, Continued
4. Mark the position of the hole in each clamp on the
equipment pad.
S. Use a masonry drill bit and drill a hole in the cement
with a diameter as determined by the concrete
anchor, at each of the marks on the equipment pad.
The hole should be approximately IY2 in. deep.
6. Insert a bolt anchor into each of the holes. Be sure
the anchors are set completely into the holes.
7. Position the anchor clamps so that the holes in the
clamps are over the bolt anchors.
8.
CHEW
OR CHL
Wrvi
Be sure that the clamp hooks are over the lip of the
heat pump base.
Insertananchorboitthrough eachclampintotheanchor
and tighten to secure the clamp and heat pump to
the equipment pad.
COILGUARD
AIR -
COIL
HEAT PUMP
BASE -
152
c- o CONCRETE - P o• c� Q'
�o EQUIPMENT PAD ,gyp po;Q 1
.Q .Q: , t3 0• i
Anchor Clamp Installation
ANCHOR
NFUviml
Water Connections and Plumbing
The image below shows the standard plumbing layout
with a single UltraTemp® Heat Pump unit. Follow the
image from right to left for the standard plumbing
sequence.
Arrangement of pool system components (other than the
standard plumbing image below), and the location of the
heat pump (above or below the pool water surface) can
affect the operation of the heat pump's water pressure
switch.
The pressure switch can be adjusted to accommodate
this effect if the heat pump water connections are no
more than six (6) feet [1.82 m] below the pool water
surface.
See instructions for pressure switch adjustment on page
6. If the heat pump is installed outside of this range, an
external pressure switch may need to be installed in the
plumbing upstream of the heat pump.
Note: Be advised that when pool equipment is located
below the pool surface a leak can result in large-scale
water loss or flooding. Pentair is not responsible for such
water loss or flooding or damage.
Automatic Flow Control Valve
The inletloutlet header of the heat pump comes equipped
with an internal automatic flow control valve. The
automatic flow control valve maintains the proper flow
through the heat pump at rates up to 120 gpm (456 Ipm).
If the filter system flow rate is higher than 120 gpm (456
Ipm), install a manual bypass valve, see image below.
Note: Be advised that if your circulation pump is over 2
HP or if the total flow exceeds 120 gpm (456 Ipm), you
will have to add an external bypass valve. Excess water
flow will damage the heat exchanger.
Standard Plumbing Layout
ULTRATEMPO Heat Pump Installation and User's Guide