Loading...
HomeMy WebLinkAboutDesign Pressure CalculationsProperty Information Owner:Evelyn McPherson Address:2743 Seneca Ave Fort Pierce, FL 34946 Building Information Wind Zone:165 MPH. Exposure Category:C Minimum Building Dimension:40 ft. Mean Roof Height:12 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 0 Int 0 0 7 0.0 0.0 1 End 37 63 7 34.5 -45.4 2 End 37 63 7 34.5 -45.4 3 End 37 63 7 34.5 -45.4 4 End 37 38 7 35.6 -47.7 5 End 37 38 7 35.6 -47.7 6 End 48 38 7 35.1 -46.6 7 End 48 38 7 35.1 -46.6 8 End 48 38 7 35.1 -46.6 9 End 40 63 7 34.3 -45.1 10 End 40 63 7 34.3 -45.1 11 End 40 63 7 34.3 -45.1 12 End 26 63 7 35.3 -47.1 13 End 37 63 7 34.5 -45.4 14 End 37 63 7 34.5 -45.4 15 End 37 63 7 34.5 -45.4 16 End 37 26 7 35.6 -47.7 17 End 53 38 7 34.8 -46.1 18 End 53 38 7 34.8 -46.1 19 End 53 38 7 34.8 -46.1 20 End 53 38 7 34.8 -46.1 21 End 53 38 7 34.8 -46.1 Prepared in accordance with: ASCE 7-16, Chapter 30. Wind Loads - Components and Cladding. 7th Edition (2020) Florida Building Code. Page 1 of 1