Loading...
HomeMy WebLinkAboutTruss. — . — .—. — . — . — . — . i i i . L ------------------------------------- EXISTING HOUSE j 30'-0" GARAGE EXTENTION PARTIAL. ER❑NT ELEVATI❑N 1/4'=1'-0' 30'-0" GARAGE EXTENTION . — . — . — . — . _ . — . — . — . 11 24'-0" GARAGE EXTENTION �, HARDI-B❑ARD SIDING OVER 1/2' PLYWD, SHEATHING NAILED AT 4' D.C. EDGES 6' ❑.C. IN FIELD OVER TRUSSES EXISTING HOUSE PARTIAL RI❑HTSIDE ELEVATION 1/4'=1'-0' EXT. FINISH ROOF MATERIAL 15# FELT PAPER OVER EXT, GRADE SEE EXT, ELEV,------- ROOF SHEATHING W/ 'H' CLIPS, METAL DRIP EDGE WOOD FASCIA, SEE ELEV, FOR STYLE - VENTED S❑FFIT — L12' T PRE-ENG, ROOF TRUSSES @ 24 O.C. MAX„ PER TRUSS MFR, — ' EXT. GRADE SHEATHING PER, SPECS, BOND BEAM FULLY GROUTED W/1 #5 CONT. W/ UPLIFT STIR PER FRAMING LAYOUT ----= #5 REBAR IN FILLED CELL — — — _ — — — — -- — — — — — -- — — PER FLOOR PLAN, W/ MIN, 25' OVERLAP, TIED TO EXISTING HOUSE C❑NT, ROD IN F❑❑TER AND BOND BEAM --� PARTIAL REAR ELEVATION SPECIAL TRUSS NOTE- 1, CONTRACTOR TO FIELD VERIFY EXISTING OVERHANG AND ROOF SLOPE S❑ NEW TRUSSES ON GARAGE EXTENTI❑N WILL MATCH, P.T. 2"x6" WOOD JAMB w/ 1 /2"x8" ANCHOR BOLTS AT 48" O.C. PLUS TOP AND BOTTOM COURSES — STUCCO FINISH DOOR TRACK GARAGE DOOR 1"x2" TRIM 4, • •a A • #5 VERT. REIN. IN POURED CELL Jamb @ Gcro e Door Detai N.T.S. STUCCO N❑TESL STUCCO APPLICATI❑N MUST BE PER R703,6,4 OR THE EXCEPTI❑N, WHICH REFERENCES ASTM C926 R703.61 ALL LATH AND LATH ATTACHMENTS SHALL BE OF C❑RR❑SI❑N-RESISTANT MATERIAL. EXPANDED METAL OR WOVEN WIRE LATH SHALL BE ATTACHED WITH 1-1/2 INCH 11 GAGE NAILS HAVING A 7/16 INCH HEAD, OR 7/8 INCH LONG 16 GAGE STAPLES SPACED NO MORE THAN 6 INCHES, OR AS ❑THERWISE APPROVED, FBC R703.6.2.1 WEEP SCREEDS, MINIMUM N❑.26 GALVANIZED SHEET GAGE C❑RR❑SI❑N-RESISTANT WEEP SCREED OR PLASTIC WEEP SCREED WITH A MINIMUM VERTICAL ATTACHMENT FLANGE OF 3-1/2 INCHES SHALL BE PR❑VIDED AT OR BELOW THE PLATE LINE ON EXTERI❑R STUD WALLS IN ACCORDANCE WITH ASTM C 926, THE WEEP SCREED SHALL BE PLACED A MINIMUM OF 4 INCHES ABOVE THE EARTH OR 2 INCHES ABOVE PAVED AREAS, THE WEATHER RESISTANT BARRIER SHALL LAP THE ATTACHMENT FLANGE, THE EXTERI❑R LATH SHALL COVER AND TERMINATE ON THE ATTACHMENT FLANGE OF THE WEEP SCREED. R703.6,3 WATER RESISTIVE BARRIERS INSTALLED OVER WOOD LASED SHEATHING SHALL INCLUDE A WATER RESISTIVE VAPOR PERMEABLE BARRIER EQUIVALENT TO 2 LAYERS OF GRADE D PAPER, WIND LOAD INFORMATI❑N THIS BUILDING HAS BEEN DESIGNED AS AN ENCLOSED STRUCTURE IN ACCORDANCE WITH THE 2020 FLORIDA BUILDING CODE, SECTION 107.2.1 THRU- 107,2,6, 1, BASIC WIND SPEED - 170 MPH 2, WIND IMP❑RTANCE FACTOR - 1 3, BUILDING CATEGORY - II 4. WIND EXPOSURE - C 5. INTERNAL PRESSURE C❑EFFICIENT - ±,18 2X BL❑CKING 3 BAYS DEEP & 48' O.C. FROM RIDGE, TOP & BOTTOM OF TRUSSES-- "'. -DRYWALL INSULATI❑N AS REQUIRED' 2X P.T. W/ 1/2 DIA. ANCHOR B❑LTS@ 32' ❑.C, P,T, FURRING & DRYWALL W/ INSUL, & V.B. DUR-❑-WALL H❑RZ, REINF, EVERY OTHER COURSE 15 .GABLE END AND BRACING DETAIL M zIr � � REVIEWED `w'OD E COMPLIANCE J S A;ClE COUNTY 90cc = w Pa zP4b- 0 3 ¢Jow J W 3 W H Pa AUWW U< L, LLj I14-L�F-_j W J I- W W i--i Q Z O W xWH_ux- V Q u P° o¢�_ra Pa Z ' Q Jl7�Q Z Q - W V)�qll� F-J �WU HzZW-��ZW F- o w ¢v».aF,tl � A F —.w li Q Vl W Ld M S� 0L'L U Z d. ¢ W 5 a:W ._. M F-��� _s* x A te+{' H F-1 �.L Sr %d z H J lart . xl�� �— ~ y.a fly V1§2: g e O Pa 3 w, F Z m 7�-iW W Q Y Q A W .A ' i z �o¢¢F-v, ' �oc�3X:z: zwE'w aFLmj: 7: v� v~i N ¢�¢o� z o WWoVPa Pa PA CU W z P H JJ3�3 z w w w �¢o�� ===I-Wmm0 F- F- F- Q 0 W F- W r—. '00000��� J7 w U P� w � w QM� 71->CGL ILL �zw c�px PAGE NEI, 1 OF 3 DATE, 7-16-2021 DRAWN BY W, PAIGE — — . . F— . — EXISTING WALL ❑F HOUSE I. EXISTING WALL USE (4) 12' L( BARS WITH MIP EMBEDMENT IN EXISTING WALL EVENLY VERTI DOWEL AND EP NEW WALL TO WALL TYPICAL EXISTING ADJACENT k EXISTING ADJACENI _EXISTING WALL OF HOUSE _ _ _ _ _ USE (4) 12" LG, N❑,5 BARS WITH MIN, 4" EMBEDMENT INT❑ EXISTING WALL SPACED EVENLY VERTICALLY DOWEL AND EPDXY FOR NEW WALL TO EXISTING WALL TYPICAL. ELECTRICAL NOTL JU -V PARTIAL FLOOR PLAN 1, PLANS DESIGNED ACCORDING TO 2015 NEC. 2, ALL OUTLETS TO HAVE ARC -FAULT CIRCUIT INTERCEPTOR COMBINATION TYPE„ 3, SMOKE DETECTORS ALSO DECTECT CARBON M❑NOXIDE. 4, ALL OUTLETS TO BE TAMPER RESISTANT, OTES MASONRY DOfPNPOUR 'H i NO.5 BAR HOOKED INTO JNDATION AROUND EACH OPENING ) AT EACH CORNER AND 48" O.C. ERMEDIATE. AND ELECTRICAL ELECTRICAL SYMBOLS LEGEND 0 CEILING FAN & LIGHT ® RECESSED LIGHTS COMB, EXHAUST FAN & LT 4'-0" F-LOURESENT SINGLE POLE SWITCH 220 OUTLET v PHONE JACK PANEL BOX 4P DUPLEX OUTLET LIGHTING OUTLET OS.D./C.0. SMOKE DETECTOR CABLE —READY— OUTLET 0G.F.I, GROUND FAULT OUTLET T FLOOD LIGHTS DISC❑NNECT E04 EXHAUST FAN ❑NLY QUADRA—PLEX OUTLET O I N O cV TABLE No. 4 REINFORCING SCHEDULE & LOAD CAPACITIES SAFE WORKING LOADS (PLF) 8" x 16" COMPOSITE LINTELS MARK LINTEL CLEAR LINTEL LINTEL LINTEL GRAVITY SAFE LOAD UPLIFT SAFE LOAD NO. LENGTH SPAN TYPE TOP BARS BOTTOM BARS SOLID SOLID SOLID #5(1)U(0)L SOLID #5(1)U(0)L #5(1)U(1)L #5(1)U(1)L #5(2)U(1)L A BAR B BAR DETAIL H DETAIL J DETAIL H& J DETAIL K M-1 4'-8" 3'-0" Precast #3 2 2 NONE 10000 1 10000 10000 1 10000 M-2 17'-8" 16'-0" Precast 2 3 2 2 NONE 5931 1 10000 10000 I 10000 ENGINEERING SPECIFICATIONS: 1.) SAFE LOADS ARE TOTAL SUPERIMPOSED ALLOWABLE LOADS 2.) DESIGNER MAY EVALUATE CONCENTRATED LOADS FROM THE SAFE LOAD TABLES BY CALCULATING MAX. RESISTING SHEAR AND MOMENT FOR THE LISTED LINTELS. 3.) SAFE LOADS LISTED ON ALL TABLES ARE IN UNITS OF POUND PER LINEAR FOOT. GENERAL NOTES: 1.) CODES 1.1 FLORIDA BUILDING CODE 2020. 1.2 BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI 318-02). 1.3 AMERICAN SOCIETY OF CIVIL ENGINEERS MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES (ASCE 7-98). 2.) CONCRETE: 2.1 CONCRETE COMPRESSIVE STRENGTH AT 28 DAYS: 2.1.1 PRE -CAST W/STANDARD REINFORCEMENT-4000 PSI MIN. 2.1.2 PRE -CAST W/PRESTRESS REINFORCEMENT-6000 PSI MIN. 2.1.3. GROUT PER ASTM C476 - 3000 PSI W/ MAX. 3/8" AGGERATE, 8" TO 11" SLUMP. 2.2 REINFORCING BARS: 2.2.1 STEEL PLACED IN PRECAST LINTEL AT TIME OF FABRICATION ASTM A615 (GRADE 60) 2.2.2 STEEL IN LINTEL AND KNOCKOUT BLOCK (PLACED IN FIELD) ASTM A615 (GRADE 40). 2.3 PRESTRESS STRANDS ASTM A416 7-WIRE, STRESS RELIEVED 270 KSI 2.4 DETAIL REINFORCEMENT IN ACCORDANCE WITH ACI 315 2.5 CONCRETING OPERATIONS SHALL COMPLY WITH ACI STANDARDS. 3) MASONRY: 3.1 DESIGN AND CONSTRUCTION SHALL CONFORM TO THE SPECIFICATION OF THE NATIONAL CONCRETE MASONRY ASSOCIATION AND ACI 530-02. 3.2 MINIMUM MASONRY UNIT STRENGTH: F'M 1500 PSI. 3.3 MORTAR SHALL BE TYPE S. 4)STRUCTURAL: 4.1 SAFE LOAD VALUES ARE BASED ON LINTELS HAVING A BEARING OF 8" (WITH A MINIMUM ACCEPTABLE BEARING OF 4" PER THE FLORIDA BUILDING CODE 2020 4.2 FOR LINTELS THAT ARE GREATER THAN 14'-0" CLEAR SPAN THEY SHALL BE PROVIDED A TEMPORARY SUPPORT AND THE TEMPORARY SUPPORT SHALL NOT BE REMOVED UNTIL 2 DAYS AFTER GROUT PLACEMENT. CASTCRETE LINTEL USE DETAIL J FOR ALL LINTELS TYPE DESIGNATION P - PLAIN LINTEL/ QUANTITY OF #5 BAR AT S - SOLID LINTEL LOWER LINTEL CAVITY [8xl6-P-lL/lU1 NOMINAL WIDTH J L QUANTITY OF #5 BAR AT NOMINAL HEIGHT UPPER LINTEL CAVITY 3000 PSI CONC. FILL TOP BARS: (CONCRETE PLACED —7 /— (SEE SCHED.) IN FIELD) / (1) #5 CONTINUOUS OPTIONAL 7/32" STIRRUPS AT 4'-0" CC ` (TIED OR WELDED) I a "A" BARS (MAIN REINF.) IC p SEE SCHEDULE "B" BARS - SEE SCHEDULE 7 5/8' NOTES: 1. MINIMUM COVERAGE OF STEEL - 1.5" 2. MIN. BEARING REQUIRED AT EA. END - 4" 3. STANDARD FOR REINF. STEEL - ASTM A615 TYPICAL LINTEL SECTION - PRECAST CONCRETE = w A Z A L- 0 3 ¢www :j w3w 0 Z " A W l7 W Z A U W ¢ vJU¢ V1 �JQAWWLLI zwwww�¢b- � = U � ? �0pv1;IN,� , pwq '~-' Z Imo— <� U 30¢ A . AAJF-0E¢'Q y lye Z¢UH 4� 9.e1 yi z LLI 0 W � r: oz F-Z-Z FfnLi U o:iiJ ¢ Z W ~ IL.,d,1 U5 W vql Z 0L�� U W A u p � Z h-1 J ¢ Wu nary a = W W ,tt,,.vI H L7 LD � A Z H H iL6i¢6!i z W Q 3 Z A3_j ZrE -i LLI 0 Z > \ w I- z A LD L,,I w Li(UjY¢0LLJ wU<A \ CL A�QA�H¢I- O H zwoc.�3�z� zo�w 1- 2: ¢ LD "F-C)pJgAQU� W W W oUA q� z APq(UJwz ~ Q wwwa_¢o"� 3 ===0-w==H t- F- F- < O F- O w v cG w HMO /�vNj d-� w � zww k!m PAGE NO. 2 OF 3 DATE: 7-16-2021 \ DRAWN BY W, PAIGE W w ci W � W M � o O 00 �, Q H - - --------- EXISTING WALL OF HOUSE I II I� .I I I. .I �I I� I. .I �I I' I. II 'I I. I �I I. I. II I I. .I .I L.-.-.-.- -. L-.-.-.- EXISTING WALL OF HOUSE 71 Lj I� IJ J Q •3 z H H Iw �I bI0 J �I 3 0. WI X wl I I� EXISTING WALL OF HOUSE _ _ _ _ _ _ _ I-- - - - - - - . - . - - . - . - . - . - . - . - . - . .yam 1, SOIL CLASSIFIED AS SILTY SAND WITH A DESIGN L❑AD-BEARING CAPACITY (ALLOWABLE F❑UNDATION PRESSURE) OF 2,000 PSF, 2, S❑IL BELOW NEW F❑UNDATI❑NS SHALL BE COMPACTED TO A MINIMUM OF 98% OF MAXIMUM DENSITY PER ASTM D-1557, CONCRETE & MASONRY 1, CONCRETE SHALL CONFORM TO THE REQUIREMENTS OF ACI 318 AND HAVE A MINIMUM C❑MPRESSIVE STRENGTH OF 3,000 PSI AT 28 DAYS, 2, REINFORCEMENT STEEL SHALL BE NO. 5 BARS CONF❑RMING TO ASTM A615, GR, 40, CONCRETE COVER FOR REINFORCEMENT SHALL BE A MINIMUM OF 3" IN FOOTINGS AND 1-1/2' IN BEAMS & COLUMNS. 3, REINF❑RCEMENT SHALL BE BENT COLD, THE MINIMUM DIAMETER OF THE BEND FOR NO. 5 REBAR MEASURED ON THE INSIDE OF THE BAR SHALL BE 3-3/4", SPLICES SHALL BE LAP SPLICES WITH A MINIMUM OVERLAP OF 25" FOR NO. 5 REBAR, 4, LOAD BEARING CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90, MORTAR SHALL COMPLY WITH ASTM C270, TYPE M, N, OR S C❑NFORMING TO ASTM A270, 5, THE MINIMUM NET AREA COMPRESSIVE STRENGTH OF MASONRY SHALL BE 1,900 PSI WHEN USING TYPE M OR S MORTAR AND 2,150 PSI WHEN USING TYPE N MORTAR AS DETERMINED BY THE PRISM TEST METHOD IN ACCORDANCE WITH ASTM C1314, 6. ALL EXTERIOR WALLS ARE SHEAR WALLS 7, TRUSS STRAP TOLERANCE IS 1-1/2' MAX BETWEEN TRUSS & STRAP, IF NOT, USE TWIST TIES W/ 6 - 6d NAILS @ EACH TRUSS & 3 - 0,1450 TAPCONS DRILLED INT❑ CONCRETE, WHERE APPLICABLE, 30'-0" 7'-0" 1, 16'-0„ 11 7'-01) FOUNDATION PLAN- 1/ ENGINEERING NOTES No-= 1, ALL STRUCTURAL LUMBER SHALL BE SOUTHERN YELLOW PINE (SYP) OR SPRUCE WITH A BENDING STRESS, Flo, NO LESS THAN 1,400 PSI, 2, ALL WOOD MEMBERS IN CONTACT WITH CONCRETE OR MASONRY SHALL BE NATURALLY DURABLE OR PRESERVATIVE TREATED WOOD OR HAVE A VAPOR BARRIER INSTALLED BETWEEN THE WOOD & CONCRETE (15# FELT MIN,) 3, EXTERI❑R WALLS ARE SHEAR WALLS SHALL HAVE A MINIMUM 7/16' THK APA RATED SHEATHING ATTACHED TO STUDS W/ 8d NAILS AT 6" O,C AT PANEL EDGES UNLESS OTHERWISE NOTED. INTERIOR SHEAR WALLS SHALL HAVE A MINIMUM 7/16" THK APA RATED SHEATHING ATTACHED TO STUDS W/ 8d NAILS 6' D.C. 4, INTERIOR SHEAR WALLS & BEARING WALLS SHALL BE SECURED TO FO❑TER W/ HILTI KWIK-BOLT 2 (5/8' x 7' LG) WEDGE ANCHOR W. 2"x2'x1/8' THK PLATE WASHERS SPACED 21' O,C MAX, WITH 3 1/2" MIN. EMBEDMENT 5, ROOF SHEATHING IS A DIAPHRAGM - 1/2' PLYWOOD SHEATHING (4-PLY) USE 8D RING SHANK NAILS 4' D.C. ALL WAYS & NAIL EAVE EDGES 4" D.C. 6, EXTERI❑R WALLS TO HAVE HEADER OVER OPENINGS PER DETAIL 7, ALL CONNECTORS SHALL BE NAILED PER MANUFACTURER'S SPECIFICATIONS. IF INTO THE 1-1/2' DIMENSION OF 2x's, NAIL SHALL BE 1-1/2" LONG 8, INTERCHANGEABILITY BETWEEN SIMPSON & USP CONNECTORS IS ALLOWED USING THE APPROPRIATE CROSS REFERENCE EXTERI❑R FINISH 1, A WATER RESISTANT BARRIER IN C❑MPLIANCE WITH ASTM D226 SHALL BE APPLIED OVER STUDS OR SHEATHING PRIOR TO APPLICATI❑N OF CEMENT PLASTER FINISH AND HAVE PERFORMANCE EQUAL TO AT LEAST TWO LAYERS OF GRADE D PAPER, 2, INSTALLATION OF EXTERIOR LATHING & FRAMING OVER FRAME WALLS SHALL COMPLY WITH ASTM C1063 3, EXTERI❑R PLASTER SHALL COMPLY WITH ASTM C926, OVER MASONRY CONSTRUCTION, SCRATCH COAT SHALL BE APPROXIMATELY 3/8' THICK AND THE FINAL COAT APPROXIMATELY 1/4' THICK, OVER SHEATHED WOOD FROM CONSTRUCTION, A 3-COAT SYSTEM SHALL BE EMPLOYED RESULTING IN A TOTAL THICKNESS OF 7/8, 0 d- CV 1' X 4' RAT RUN BRACING @ 10'-0' ❑,C, FASTENED T❑\ EACH TRUSS W (2) 10d NAILS R-19 INSULATION- 5/8' DRYWALL CEILING MASONRY BOND BEAMS SHALL 8' X 16' WITH 2 C❑NTINU❑S N0,5 BARS AND POURED S❑LID ACRO❑S ALL OPENINGS, SINGLE HUNG WIND❑W 8' X 8' X 16' CONC. BLOCK WALL 1/2' DRYWALL OVER 2' X 2' FURRING S WITH R-4,33 F❑IL BACK INSULATI❑N SHINGLES OVER 30LB, FELT OVER 1/2' PLYWOOD SHEATHING NAILED AT 4' D.C. EDGES 8' D.C. W/8D RING SHANK NAILS INTERMEDIATE OVER PRE-ENGINEERED ROOF TRUSSES AT 2'-0' ❑,C, 12 3 SEE CONNECTOR SCHEDULE FOR STRAPPING., DRIP EDGE SEE' -ALUMINUM S❑FFITT ELEVATI❑NS = w Z J O J F- Li j 3 J w w vi w -DENOTES 7/8' THICK STUCCO F_ w J w w w DENOTES MASONRY DOWNPOUR WITH 1 N0,5 REBAR SEE FL❑❑RPLAN FOR L❑CATI❑N. a�. GRADE ` 4 z0 (U 2 N❑,5 BARS C❑NT,-\. • 16' WALL SECTI❑N N.T.S. - - a. GRADE ` d 4 o "0 (U 2 N❑,5 BARS C❑NT,-,\ • 16" SECTI❑N F--1 1/2"=1'-0" 5 BAR IN GROUTED CELLS EL. (0'-01/) 3 NO,5 BARS SECTION F-2 w w � w w M w'd- wMw cv �� w � cn w �ox z�Q QaQ ww¢ L E NO,OF 37-16-2021 W, PAIGE W W H � cz) W M � o O 00 �, Q H