HomeMy WebLinkAboutConstruction PlansGENERAL NOTES DESIGN CRITERIA: ���� COPY APPLICABLE CODES, REGULATIONS & STANDARDS: 1. THE 2020 FLORIDA BUILDING CODE, 7TH EDITION SPECIFICALLY CHAPTER 16 STRUCTURAL DESIGN, CHAPTER 20 ALUMINUM 2. ASCE 7-16 & SE17 3. AC1318 CONCRETE REFRENCE MANUAL. 4. AA ASM 35 & AA ADM 1 5. AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS. WIND LOADS: 1. FBC TABLE 1604.5, RISK CATEGORY = 1 2. FBC SEC 1609.4, EXPOSURE CATEGORY = C 3. FBC SEC 1609.3, ULTIMATE DESIGN WIND SPEED = 150 MPH DESIGN NOTES: ALLOWABLE DESIGN PRESSURES UTILIZED IN THIS DOCUMENT HAVE BEEN CALCULATED PER THE REQUIREMENTS OF THE FLORIDA BUILDING CODE 7TH EDITION (2020) & ASCE 7-16 USING ALLOWABLE STRESS DESIGN METHODOLOGY WITH THE CRITERIA AS OUTLINED HEREIN. THE CONTRACTOR SHALL CONTACT THE AUTHORITY HAVING JURISDICTION TO ENSURE APPROPRIATE CRITERIA TO BE USED BEFORE CONSTRUCTION BEGINS. THE SYSTEM HAS NOT BEEN DESIGNED TO WITHSTAND CONCETRATED LOADS FROM HUMAN ACTIVITY. DRAWING INDEX SHEET NO. DESCRIPTION G01 GENERAL NOTES S01 STRUCTURAL PLAN F01 FOUNDATION PLAN D01 ROOF & PROJECTION BEAM DETAILS D02 POST & MAIN BEAM DETAILS D03 DOLCE SCREEN WALL DETAILS D04 DOLCE SCREEN WALL MEMBERS REVIEWED FOR CODE COMPLIANCE ST. WCIE COUNTY BOCC GENERAL NOTES: 1. THIS DOCUMENT SHALL NOT BE USED OR REPRODUCED WITHOUT THE ORIGINAL SIGNATURE & RAISED SEAL OF CRAIG E. GUNDERSON, P.E. ALTERATIONS, ADDITIONS OR OTHER MARKINGS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE OUR CERTIFICATION. PHOTOCOPIES AND UNSEALED DOCUMENTS ARE NOT TO BE ACCEPTED. 2. THIS STRUCTURE HAS BEEN DESIGNED AND SHALL BE FABRICATED IN ACCORDANCE WITH THE STRUCTURAL PROVISIONS OF THE FLORIDA BUILDING CODE SEVENTH EDITION (2020). STRUCTURE SHALL BE FABRICATED IN ACCORDANCE WITH ALL GOVERNING CODES. CONTRACTOR SHALL INVESTIGATE AND CONFORM TO ALL LOCAL BUILDING CODE AMENDMENTS WHICH MAY APPLY AND GOVERN. DESIGN CRITERIA OR SPANS BEYOND STATED HEREIN MAY REQUIRE ADDITIONAL SITE SPECIFIC SEALED ENGINEERING. 3. NO 33-1/3% INCREASE IN ALLOWABLE STRESS HAS BEEN USED IN THE DESIGN OF THIS SYSTEM. WIND LOAD DURATION FACTOR Cd=1.6 HAS BEEN USED FOR WOOD ANCHOR DESIGN. 4. THE ARCHITECT/ENGINEER.OF RECORD FOR THE PROJECT SUPERSTRUCTURE WITH WHICH THIS DESIGN IS USED SHALL BE RESPONSIBLE FOR THE INTEGRITY OF ALL SUPPORTING SURFACES TO THIS DESIGN WHICH SHALL BE COORDINATED BY THE PERMITTING CONTRACTOR. 5. THE CONTRACTOR SHALL CAREFULLY CONSIDER POSSIBLE IMPOSING LOADS ON ROOF, INCLUDING BUT NOT LIMITED TO ANY CONCENTRATED LOADS WHICH MAY JUSTIFY GREATER DESIGN CRITERIA. THIS ADDITIONAL ROOF LOAD CRITERIA SHALL BE PROPERLY ANALYZED BY A LICENSED ENGINEER OR REGISTERED ARCHITECT. 6. ALL FASTENERS TO BE #12 SAE GRADE 2 OR STAINLESS STEEL 304 UNLESS NOTED OTHERWISE. FASTENERS SHALL BE CADMIUM -PLATED OR OTHERWISE CORROSION -RESISTANT MATERIAL AND SHALL COMPLY WITH SPECIFICATIONS FOR ALUMINUM STRUCTURES" BY THE ALUMINUM ASSOCIATION, INC., & ANY APPLICABLE FEDERAL, STATE, AND/OR LOCAL CODES. 7. FOR ALUMINUM MEMBERS ALL ANCHORS SHALL BE SPACED WITH 2xDIAMETER END DISTANCE AND 2.5xDIAMETER MIN. SPACING TO ADJACENT ANCHORS, UNLESS NOTED OTHERWISE. 8. ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS. MINIMUM EMBEDMENT SHALL BE AS NOTED HEREIN. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDES STUCCO, FOAM, BRICK, AND OTHER WALL FINISHES. 9. ALL CONCRETE ANCHORS SHALL BE INSTALLED TO NON -CRACKED CONCRETE ONLY. 10. WOOD HOST STRUCTURE 84 ALL WOOD MEMBERS SHALL BE "SOUTHERN YELLOW PINE" G=0.55 OR GREATER DENSITY. 11. THE CONTRACTOR IS RESPONSIBLE TO INSULATE ALL MEMBERS FROM DISSIMILAR MATERIALS TO PREVENT ELECTROLYSIS. 12. ALL ALUMINUM SHALL BE 6005-T5 ALLOY AND TEMPER UNLESS NOTED OTHERWISE. 13. ALL STEEL ANGLES SHALL BE ASTM A1011 OR A653 GRADE 50 (Fy=50 KSI, Fu=65 KSI) OR BETTER. 14. ALL CONCRETE AND EPDXY TO REACH A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI IN 7 DAYS. 15. ENGI.NEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR, et. al. INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COST & DAMAGES INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FROM MATERIAL FABRICATION, SYSTEM ERECTION, & CONSTRUCTION PRACTICES BEYOND THAT WHICH IS CALLED FOR BY LOCAL, STATE, & FEDERAL CODES & FROM DEVIATIONS OF THIS PLAN. 16. EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED. 17. ALTERATIONS, ADDITIONS, HIGHLIGHTING, OR OTHER MARKINGS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE THIS CERTIFICATION. SYSTEM NOTES: PERGOLA SHALL BE INSTALLED PER MANUFACTURER'S SPECIFICATION ISSUED BY RENAISSANCE PATIO. REFER TO AFOREMENTIONED MANUFACTURER ISSUED ASSEMBLY MANUAL FOR ALL CONNECTION DETAILS THAT ARE NOT ILLUSTRATED HEREIN. , �C co o O ul N __Z o _ co M - 3 ui LLI //IIIIIIIIIIII\\\` U < U11-- .J O J V-- V z w W z_ 3 W 0 O U— r d' N w m co M p o U p U JI M 0) U_ LO •LU L � N F-M --•c Q 2 H d N co ti 0 w U U co cm N co T_ N rn O M 0 z � LL :D U) QY y J Q zow U) a Q U Q , % w U c� tY IDESIGN DATE: 11/23/2021 1 REVISION 1: DATE PAGE: REVISION 2: DATE IG01 SCALE: NTS N E� 300( W/ FI 8"X8" HOST WALL 1 CONCRETE PLAN F01 SCALE: N. T. S FOOTING NOTES 1. PROVIDE 1-1/2" COVERAGE TOP, SIDES, BOTTOM AND 1" BETWEEN ADJACENT REBAR LAPS. 2. PROVIDE MIN. 3" COVERAGE OF REBAR FOR ALL CONCRETE IN CONTACT WITH THE EARTH. 3. FOOTING CONCRETE SHALL BE MIN. 3000 PSI AT 28 DAYS 4. FOOTING REINFORCEMENT SHALL BE MIN. GRADE 40 5. PROVIDE POSITIVE DRAINAGE AWAY FROM STRUCTURE TO CITY / CO. REQUIREMENTS 6. PROVIDE 2500 PSF BEARING (TYPICAL) UNDER FOUNDATION 7. SEE GENERAL NOTES FOR TYING INTO EXISTING FOUNDATIONS 8. SEE GENERAL NOTES FOR ADDITIONAL CONCRETE INFORMATION & SPECS. (6) 5/16" DIA ITW TAPCON, 5/16" DIA. SAE GRADE WASHER, 2.25" EMBEDMENT, 3.75" SPACING, 1.57" MIN. EDGE DISTANCE INTO 3KSI MIN. CONCRETE 4 4 1" 2 2 ANCHORS TO BASE PLATE F01 SCALE: N. T. S o O =C� w ( 0 Q z- v� z° U) o _ U 1'-- J O N In J 00 co U1 E— co z z O �/ LL U qt� p U w 0 co � W U- Lo .c Z LLI� N WQ��a� 0 Q — I- V 0 O J u IL N O Co LLI 0- CF 0 C7 Ui U N co r- 0 Lu U U M CV M_ 04 NEW 4" SLAB 3000 PSI OO W/ FIBERMESH SODDED GRADE a e . z I l) #5 BAR 8" CONTINUOUS > LL Q Y } � J Q Lu ~ o ZOO 8"X8" MONOLITHIC FOOTING J F �Tw Q v M SCALE: N. T. S DESIGN DATE: 11123/2021 REVISION 1: DATE PAGE: REVISION 2: DATE F01 SCALE: NTS ATTACH TO CARRY BEAM W/ #12 SELF -DRILLING SCREW 12" MAX, TYP. W/ 1" OD WASHER MAIN BEAM @6" 0.C, TYP. 1.5" MAX INTERIOR CLIP% E HD BEAM HD POST (3) 3/8 X5" BOLT, WASHER & NUT, TYP. 1 HD BEAM TO POST D02 CONNECTION c*4 0.12 2" HD BEAM INTERIOR CLI P 2 HD POST EMBEDMENT D02 HD POST HD POST CLIP SLIDE BASE PLATE COVER OVER POST & BASE PLATE (OPTIONAL) REBAR 12" LONG ROUGH POST, TYP. 2.750 HD MAIN BEAM HD PO_` HD BASE PI SLIDE BASE PLATE COVER OVER POST & BASE PLATE 4) #14 SELF DRILLING CREW PER SIDE, TYP. (6) CONCRETE ANCHORS (SEE PAGE F01) HID POST 3 ANCHOR CONNECTION D02 i— 3 6„ 1 Lo 62" HD BASE PLATE ...... Ur • W Lu I- Z ��•z __ k �i 9 POST & MAIN BEAM DETAILS V It- J O N r D7 F_ cc i z Z p o —�/ � W U O� p cU uJJ 000 a, W < LL LC> •L z w1 N z c WQJd'o O 0 `°ry O J 0 N O O ui a c C7 w N 00 I- C) w U U M T- 0 [V M N O Z H- U W O a U) 2 N Lo O O a' M w Z W J > LL Z) U) QY cl) �Q U) --I n- O U) ¢ W J U Q w M Q_ DESIGN DATE: 11/23/2021 REVISION 1: DATE PAGE. REVISION 2: DATE DO, SCALE: NTS INNER FRAME SCREW 12" O.C. SD/HD -ALUMINUM PICKET/ I I PICKET MOUNT SPACER IwIs] :/ PICKET SPACE[ PICKET MOUNT SCREW 12" O.C:� I M -ALUMINU/,.-SNAP CAP OUTER FRAM 1SCREW 12" O.C. SD/HD -CONCRETE -WOOD FLOOR or WALL PICKET CONNECTIONS SCREW 12" O.C. INNER FRAME -ALUMINUM SD/HD THICK SNAP CA KICK PANEL FRAME THICK SNAP CAP KICK PANE THICK KICK PANEL FRAME OUTER FRAME SD / H SCREW 12" O.C. -ALUMINUM SNAP CA SCREW 12" O.C. -CONCRETE FLOOR or WAL -WOOD THICK KICK PANEL CONNECTIONS SCREW 12" O.C. INNER FRAM -ALUMINUM SD/HD THICK KICK PANEL THIN FRAME KICK PANE ADAPTER THIN KICK PAN SNAP CA THIN KICK PANEL ADAPTER, SNAP CA SCREW 12" O.C. -CONCRETE -WOOD SNAP CAP THICK KICK PANEL FRAME CLIP COVE JNNEU I IUN SCREW x4 -CLIP INNER FRAME SD/HD INNER FRAME CONNECTIONS SCREW 12" O.C. -ALUMINUM SNAP SCREW 12" O.0 -CONCRETE -WOOD POST or BEAM SNAP CAP OUTER FRAME SD/HD OUTERFRAME SD/HD FLOOR or WALL ; CO C) u- O LLJ z � �cv ,�i6; •oft`\� lll 0\0 USN .J O J rn UI l— (M Zzp o U p U LLI .J O ao W<u � LLI W< -j � U � ~ I— O (.c) J 1-0 I- LL IL N 00 r- 0 W U U M T- m N M_ N O z w O a OUTER FRAME OUTER FRAME CONNECTIONS w 0 m SD/HD o M w W J SCREW 12" O.C. SCREW SPECIFICATIONS: � Q -ALUMINUM -CONCRETE (Hex Head #14 x 2") U yLu } J Q FLOOR or WALL -WOOD (Drilling Head Head 1/4" x 1-1/2") o z ow -ALUMINUM (Drilling Hex Head #10 x 1/2") ° ~ IRM > -CLIP (Drilling Flat Head #10-x 3/4") Q � v M z o o w U a DESIGN DATE: 11/23/2021 REVISION 1: DATE PAGE: DOLCE SCREEN WALL DETAILS REVISION 2: DATE DO: SCALE: NTS cMld N MIS N 1 " 180018 OUTER FRAME (SD) m CY) N c')Id N 180017 INNER FRAME (SD) 91f 180082 180081 OUTER INNER FRAME FRAME (HD) (HD) 2„ 1 MIS 2 �� 0.062 180059 180020 SCREW DOOR (CONCRETE) JAMB 1" 1 2 If ��— 1 2 180062 180053 SCREW SCREW (WOOD) (ALUMINUM) n 311 8 1040 ce)ld' 180021 SNAP CAP 180086 CONNECTION CLIP 5� 180087 CLIP COVER F50.063 Mld N 180019 PICKET MOUNT 3" 4 0.062 c0ldw 180022 PICKET 3" 4 180033 180090 PICKET SCREW SPACER (CLIP) 1" 2 180023 THICK KICK PANEL FRAME 7" 16 �CD 0.040 180024 THIN KICK PANEL ADAPTER 15" 16 mil 180025 KICK PANEL SNAP -IN 180034 CORNER (KICK PANEL) 0 `w co Q a ' z U) O\ =y /''/////IIIIII moo DOLCE SCREEN WALL MEMBERS USN J O Lo J � � I— co Zzp o U cr- p U WJOao� W LL Lo L Z w 1 a� z I" M c WQJd'N o� O c o J a LL Ld W Q 0 N 00 0 W U U cM co N cM N O z I— U W � L0 O O rn M z af w LJL. U) QY U) J Q I— ww �.J EL o ZOof w = w J J 0 , Q w U cf DESIGN DATE: 11/23/2021 REVISION 1: DATE PAGE REVISION 2: DATE D04 SCALE: NTS