Loading...
HomeMy WebLinkAboutCONSTRUCTION PLA PERGOLAGENERAL NOTES DESIGN CRITERIA: APPLICABLE CODES, REGULATIONS & STANDARDS: 1. THE 2020 FLORIDA BUILDING CODE, 7TH EDITION SPECIFICALLY CHAPTER 16 STRUCTURAL DESIGN, CHAPTER 20 ALUMINUM 2. ASCE 7-16 & SE17 3. ACI318 CONCRETE REFRENCE MANUAL. 4. AA ASM 35 & AA ADM 1 5. AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS. WIND LOADS: 1. FBC TABLE 1604.5, RISK CATEGORY = 1 2. FBC SEC 1609.4, EXPOSURE CATEGORY = C 3. FBC SEC 1609.3, ULTIMATE DESIGN WIND SPEED = 150 MPH DESIGN NOTES: ALLOWABLE DESIGN PRESSURES UTILIZED IN THIS DOCUMENT HAVE BEEN CALCULATED PER THE REQUIREMENTS OF THE FLORIDA BUILDING CODE 7TH EDITION (2020) & ASCE 7-16 USING ALLOWABLE STRESS DESIGN METHODOLOGY WITH THE CRITERIA AS OUTLINED HEREIN. THE CONTRACTOR SHALL CONTACT THE AUTHORITY HAVING JURISDICTION TO ENSURE APPROPRIATE CRITERIA TO BE USED BEFORE CONSTRUCTION BEGINS. THE SYSTEM HAS NOT BEEN DESIGNED TO WITHSTAND CONCETRATED LOADS FROM HUMAN ACTIVITY. DRAWING INDEX SHEET NO. DESCRIPTION G01 GENERAL NOTES S01 STRUCTURAL PLAN F01 FOUNDATION PLAN D01 ROOF & PROJECTION BEAM DETAILS D02 POST & MAIN BEAM DETAILS GENERAL NOTES: 1. THIS DOCUMENT SHALL NOT BE USED OR REPRODUCED WITHOUT THE ORIGINAL SIGNATURE & RAISED SEAL OF CRAIG E. GUNDERSON, P.E. ALTERATIONS, ADDITIONS OR OTHER MARKINGS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE OUR CERTIFICATION. PHOTOCOPIES AND UNSEALED DOCUMENTS ARE NOT TO BE ACCEPTED. 2. THIS STRUCTURE HAS BEEN DESIGNED AND SHALL BE FABRICATED IN ACCORDANCE WITH THE STRUCTURAL PROVISIONS OF THE FLORIDA BUILDING CODE SEVENTH EDITION (2020). STRUCTURE SHALL BE FABRICATED IN ACCORDANCE WITH ALL GOVERNING CODES. CONTRACTOR SHALL INVESTIGATE AND CONFORM TO ALL LOCAL BUILDING CODE AMENDMENTS WHICH MAY APPLY AND GOVERN. DESIGN CRITERIA OR SPANS BEYOND STATED HEREIN MAY REQUIRE ADDITIONAL SITE SPECIFIC SEALED ENGINEERING. 3. NO 33-1/3% INCREASE IN ALLOWABLE STRESS HAS BEEN USED IN THE DESIGN OF THIS SYSTEM. WIND LOAD DURATION FACTOR Cd=1.6 HAS BEEN USED FOR WOOD ANCHOR DESIGN. 4. THE ARCHITECT/ENGINEER OF RECORD FOR THE PROJECT SUPERSTRUCTURE WITH WHICH THIS DESIGN IS USED SHALL BE RESPONSIBLE FOR THE INTEGRITY OF ALL SUPPORTING SURFACES TO THIS DESIGN WHICH SHALL BE COORDINATED BY THE PERMITTING CONTRACTOR. 5. THE CONTRACTOR SHALL CAREFULLY CONSIDER POSSIBLE IMPOSING LOADS ON ROOF, INCLUDING BUT NOT LIMITED TO ANY CONCENTRATED LOADS WHICH MAY JUSTIFY GREATER DESIGN CRITERIA. THIS ADDITIONAL ROOF LOAD CRITERIA SHALL BE PROPERLY ANALYZED BY A LICENSED ENGINEER OR REGISTERED ARCHITECT. 6. ALL FASTENERS TO BE #12 SAE GRADE 2 OR STAINLESS STEEL 304 UNLESS NOTED OTHERWISE. FASTENERS SHALL BE CADMIUM -PLATED OR OTHERWISE CORROSION -RESISTANT MATERIAL AND SHALL COMPLY WITH "SPECIFICATIONS FOR ALUMINUM STRUCTURES" BY THE ALUMINUM ASSOCIATION, INC., & ANY APPLICABLE FEDERAL, STATE, AND/OR LOCAL CODES. 7. FOR ALUMINUM MEMBERS ALL ANCHORS SHALL BE SPACED WITH 2xDIAMETER END DISTANCE AND 2 5xDIAMETER MIN SPACING TO ADJACENT ANCHORS UNLESS NOTED FILE Copy CREWEWED FOR ODE COMpi iA m OTHERWISE. ST' LUCIE COUNTY B®C^ 8. ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS' �o �lJ RECOMMENDATIONS. MINIMUM EMBEDMENT SHALL BE AS NOTED HEREIN. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDES STUCCO, FOAM, BRICK, AND OTHER WALL FINISHES. 9. ALL CONCRETE ANCHORS SHALL BE INSTALLED TO NON -CRACKED CONCRETE ONLY. 10. WOOD HOST STRUCTURE & ALL WOOD MEMBERS SHALL BE "SOUTHERN YELLOW PINE" G=0.55 OR GREATER DENSITY. 11. THE CONTRACTOR IS RESPONSIBLE TO INSULATE ALL MEMBERS FROM DISSIMILAR MATERIALS TO PREVENT ELECTROLYSIS. 12. ALL ALUMINUM SHALL BE 6005-T5 ALLOY AND TEMPER UNLESS NOTED OTHERWISE. 13. ALL STEEL ANGLES SHALL BE ASTM A1011 OR A653 GRADE 50 (Fy=50 KSI, Fu=65 KSI) OR BETTER. 14. ALL CONCRETE AND EPDXY TO REACH A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI IN 7 DAYS. 15. ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR, et. al. INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COST & DAMAGES INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FROM MATERIAL FABRICATION, SYSTEM ERECTION, & CONSTRUCTION PRACTICES BEYOND THAT WHICH IS CALLED FOR BY LOCAL, STATE, & FEDERAL CODES & FROM DEVIATIONS OF THIS PLAN. 16. EXCEPT AS EXPRESSLY PROVIDED 'HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED. 17. ALTERATIONS, ADDITIONS, HIGHLIGHTING, OR OTHER MARKINGS TO THIS DOCUMENT ARE NOT PERMITTED AND 111,11VALIDATE THIS CERTIFICATION. SYSTEM NOTES: PERGOLA SHALL BE INSTALLED PER MANUFACTURER'S SPECIFICATION ISSUED BY RENAISSANCE PATIO. REFER TO AFOREMENTIONED MANUFACTURER ISSUED ASSEMBLY MANUAL FOR ALL CONNECTION DETAILS THAT ARE NOT ILLUSTRATED HEREIN. 0 CN toui Q 0 N w a 8 0mmr m LIM. RENAISSANCE ARIA PERGOLA 12'-0" PROJECTION BEAMS AT 24." O.C. 10'-0" Q 111 m o z o O m N U cI I_-1 O Of a POST 10'-0" SD POST & BEAM SYSTEM SHADE TUBES = 2"X2"X0.045" PROJECTION BEAM = 2"X6"X0.060" MAIN BEAM = 2.75"X7"X0.080" POST = 3.875"X3.875"X0.090" SEE SECTION DETAILS ON PAGES D01 & D02 •�•�uj 01 `4� p ti Lu — C z �� a� c A � � ��IIIIII111 POST BASE ANCHOR TIE - DOWN SCHEDULES: ANCHOR TYPES: (6) 1/4" DIA ITW TAPCON, 1/4" DIA. SAE GRADE WASHER, 1.75" EMBEDMENT, ANCHOR TYPE #1 2.5" SPACING, 3" MIN. EDGE DISTANCE INTO 3KSI MIN. CONCRETE (6) 1/4" DIA BLUE TAP ANCHOR WITH 2.1" EMBEDMENT, INTO 3KSI MIN. ANCHOR TYPE #2 CONCRETE 2.5" SPACING, 3" MIN. EDGE DISTANCE 1 ANCHOR SCHEDULE F01 SCALE: N. T. S 1" 2 -I 5 i 3n l 00 g N �'t�2� 2Z 2 ANCHORS TO BASE PLATE F01 SCALE: N. T. S FOOTING NOTES 1. PROVIDE 1-1/2" COVERAGE TOP, SIDES, BOTTOM AND 1" BETWEEN ADJACENT REBAR LAPS. 2. PROVIDE MIN. 3" COVERAGE OF REBAR FOR ALL CONCRETE IN CONTACT WITH THE EARTH. 3. FOOTING CONCRETE SHALL BE MIN. 3000 PSI AT 28 DAYS 4. FOOTING REINFORCEMENT SHALL BE MIN. GRADE 40 5. PROVIDE POSITIVE DRAINAGE AWAY FROM STRUCTURE TO CITY / CO. REQUIREMENTS 6. PROVIDE 2500 PSF BEARING (TYPICAL) UNDER FOUNDATION 7. SEE GENERAL NOTES FOR TYING INTO EXISTING FOUNDATIONS 8. SEE GENERAL NOTES FOR ADDITIONAL CONCRETE INFORMATION & SPECS. HOST WALL CONCRETE PLAN SCALE: N. T. S COLUMN (SEE PAGE-SO1 FOR SIZE) FOR SURFACE MOUNT POST: SEE PROVIDED OPTIONS 26" X 26" X 26' CONCRETE ISOLATED FOOTING (3) #5 REBARS EA. WAY (6 TOTAL) N s 26" COLUMN (SEE PAGE-SO1 FOR SIZE) 26' X 26" X 26" CONCRETE ISOLATED FOOTING (3) #5 REBARS EA. WAY (6 TOTAL) EMBED COL INTO CONCRETE 19' (1) #5 REBAR THROUGH COL • m N 26" ISOLATED FOOTING -COL ISOLATED FOOTING -COL OPTION #1 SURFACE MOUWTION #2 COLUMN EMBEDDMENT SCALE: N.T.S. SCALE: N.T.S. O co o LL O J w o- .-q N -� :U to w Q z_ w N w (1) #12 SELF DRILLING SCREW AT EVERY TRUSS, TYP. (2) #12 SELF DRILLING SCREW PER SIDE, TYP. (1) #12 SELF DRILLING SCREW AT EVERY TRUSS, 4" O.C. TYP. 4" O.C. SHADE EXISING CONCRETE TUBE OR GFB WALL, TYP. (2) 1/4" DIA. TAPCON WITH 2.5" EMBEDMENT INTO 3KS1 OR GROUT FILLED CELLS WITH 5" MIN SPACING & 6" EDGE V(2) #12 TEK PROJECTION BEAMS ® DISTANCE @ 24" O.C, TYP. EACH SIDE_z POST CAP @ 24" O.C. MAIN BEAM PROJECTION ® INTERIOR CLIP BEAM PROJECTION MAIN BEAM INTERIOR POST CLIP HOST CONNECTION 1 (CONCRETE OR BLOCK) D01 2" N 0.045 SHADETUBE 0.070 1 $" PROJECTION BEAM INTERIOR CLIP 2" m. PROJECTION BEAM (TRUSS BEAM) TRELLIS/ PROJECTION 2 & POST CONNECTION D01 r 2.030 1 0.062 1.062 �__4.154 PROJECTION BEAM EXTERIOR CLIP \\\\\\o\\111111/! o .............. v � N =Z:z o LL O - d .•-� N _� :U C(O Q _ eUl p N o LLI ' P `\\ a � 0 (1) #12 SELF DRILLING SCREW AT EVERY TRUSS, TYP. SHADE TUBES (2) #12 SELF DRILLING TRUSS BEAMS SCREW PER SIDE, TYP. @ 24 O.C. SD BEAM SD BEAM INTERIOR CLIP POST CAP NIII�ill x (2) #14 SELF DRILLING �(4) #14 SELF DRILLING SCREW PER SIDE, TYP. SCREW PER SIDE, TYP. 1 SD BEAM TO POST D02 CONNECTION SD POST �m 0.12 N 216,E SD BEAM INTERIOR CLIP 2 POST EMBEDMENT D02 0 SD POST Lo 0.125 Lo N 2.059 SLIDE BASE PLATE COVER OVER POST & BASE PLATE (OPTIONAL) REBAR 12" LONG ROUGH POST, TYP. 0 O O I` m BASE Pl. 2.750 SD MAIN BEAM SLIDE BASE PLATE COVER OVER POST & BASE PLATE 4) #14 SELF DRILLING -)CREW PER SIDE, TYP. (6) CONCRETE ANCHORS (SEE PAGE F01) POST 3 ANCHOR CONNECTION D02 316,E Lo 62" SD BASE PLATE \\��111111111111////�// N zz o LL. 6. O p J C7 W (o F- //rllllilnl111 N 0 0 co uj M c� w SD POST CLIP