HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: W ESTCOTT-JACKSON RESIDENCE
Builder Name:
Street: 5458 SILVER OAK DRIVE
Permit Office: CITY OF FORT PIERCE
City, State, Zip: FORT PIERCE, FL, 34982
Permit Number:
Owner:
Jurisdiction: CITY OF FORT PIERCE
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Types(2222.0 sgft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=5.0 1922.00 ft2
b. Frame - Wood, Adjacent
R=13.0 300.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
11. Ceiling Types (2046.0 sgft.)
Insulation Area
5. Is this a worst case? No
a Roof Deck (Unvented)
R=20.0 2046.00 f12
6. Conditioned floor area above grade (111:2) 2046
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(306.3 sqft.) Description Area
12. Ducts
a. Sup: Attic, Ret: Attic, AH: AHU CLST
R ft2
6 150
a. U-Factor: Sgl, U=0.65 306.33 ft2
SHGC: SHGC=0.25
b. U-Factor: N/A ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
35.2 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
Area Weighted Average Overhang Depth: 6.766 ft.
14. Heating systems
kBtu/Efficiency
Area Weighted Average SHGC: 0.250
a. Electric Strip Heat
27.0 COP:1.00
8. Skylights Area
c. U-Factor:(AVG) N/A fN
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 50 gallons
9. Floor Types (2046.0 sgft.) Insulation Area
EF: 0.980
a. Slab -On -Grade Edge Insulation R=0.0 2046.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
None
Glass/Floor Area: 0.150 Total Proposed Modified Loads: 66.84
PASS
Total Baseline Loads: 67.99
1 hereby certify that the plans and specifications covered by
Review of the plans and
TIJE ST.gT
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
no
with the Florida Energy Code.
PREPARED
DATE:. - -
Before construction is completed
this building will be inspected for
tv
compliance with Section 553.908
I h r certify that this bu' in designed, is in compliance
Florida Statutes.
1,t;
wit . the F ' Energy C de.
GDD >v
OW R/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
i
- Compliance requires certification by t e air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
9/29/2021 11:11 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
'
PROJECT
Title:
WESTCOTT-JACKSON REST
Bedrooms:
3
Address Type:
Street Address
Building Type:
User
Conditioned Area:
2046
Lot #
Owner Name:
Total Stories:
1
Block/Subdivision:
# of Units:
1
Worst Case:
No
PlatBook:
Builder Name.
Rotate Angle:
0
Street:
5458 SILVER OAK DRI
Permit Office:
CITY OF FORT PIERCE
Cross Ventilation:
No
County.
St. Lucie
Jurisdiction:
CITY OF FORT PIERCE
Whole House Fan:
No
City, State, Zip:
FORT PIERCE,
Family Type:
Detached
FL, 34982
New/E)asting:
New (From Plans)
Comment:
CLIMATE
v
Design Temp
Int Design Temp
Heating
Design Daily Temp
Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
2046
21277
SPACES
Number
Name
Area
Volume Kitchen
Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1
KITCHEN/DINING
340
3400 Yes
0
1
Yes
Yes
Yes
2
GREAT RM
495
5445 No
0
1
Yes
Yes
Yes
3
CLST 2
16
160 No
0
1
Yes
Yes
Yes
4
PANTRY
16
160 No
0
1
No
Yes
Yes
5
BEDROOM 2
192
1920 No
0
1
1
Yes
Yes
Yes
6
FOYER
88
880 No
0
1
Yes
Yes
Yes
7
AHU CLST
21
210 No
0
1
No
Yes
Yes
8
LAUNDRY
100
1000 No
0
1
Yes
Yes
Yes
9
HALL
32
320 No
0
1
No
Yes
Yes
10
BATH 2
54
540 No
0
1
No
Yes
Yes
11
CLST 3
18
180 No
0
1
No
Yes
Yes
12
BEDROOM 3
156
1560 No
0
1
1
Yes
Yes
Yes
13
M BATH
90
900 No
0
1
Yes
Yes
Yes
14
M TOILET
20
200 No
0
1
No
Yes
Yes
15
M WIC 2
50
500 No
0
1
No
Yes
Yes
16
M WIC 1
36
360 No
0
1
No
Yes
Yes
17
MASTER BEDROO
322
3542 No
0
1
1
Yes
Yes
Yes
9/29/2021 11:11 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
1 Slab -On -Grade Edge Insulation
KITCHENIDININ 41 ft
340 ftz
1
0
0
2 Slab -On -Grade Edge Insulation
GREAT RM
18 ft
495 ftz
__
1
0
0
3 Slab -On -Grade Edge Insulation
CLST 2
2 ft
16 ftz
__
1
0
0
4 Slab -On -Grade Edge Insulation
PANTRY
1 ft
16 ftz
___
1
0
0
5 Slab -On -Grade Edge Insulation
BEDROOM 2
37 ft
192 ftz
1
0
0
6 Slab -On -Grade Edge Insulation
FOYER
8 ft
88 ftz
1
0
0
7 Slab -On -Grade Edge Insulation
AHU CLST
1 ft
21 ftz
-_
1
0
0
8 Slab -On -Grade Edge Insulation
LAUNDRY
12 ft
100 ftz
1
0
0
9 Slab -On -Grade Edge Insulation
HALL
1 ft
32 ftz
____
1
0
0
10SIab-On-Grade Edge Insulation
BATH 2
1 ft
54 ftz
1
0
0
11Slab-On-Grade Edge Insulation
CLST 3
1 ft
18 ftz
1
0
0
12SIab-On-Grade Edge Insulation
BEDROOM 3
13 ft
156 ftz
___
1
0
0
13SIab-On-Grade Edge Insulation
M BATH
lift
90 ftz
____
1
0
0
14SIab-On-Grade Edge Insulation
M TOILET
1 ft
20 ftz
__
1
0
0
15SIab-On-Grade Edge Insulation
M W IC 2
1 ft
50 ftz
1
0
0
16SIab-On-Grade Edge Insulation
M W IC 1
1 ft
36 ftz
1
0
0
17SIab-On-Grade Edge Insulation
MASTER BEDRO 44 ft
322 ftz
__
1
0
0
ROOF
/
Roof
Gable Roof
Rad
Solar SA Emitt
Emitt
Deck
Pitch
V # Type Materials
Area
Area Color
Barr
Absor. Tested
Tested
Insul.
(deg)
1 Hip
Metal 2288 ftz
0 ftz Light
N
0.3 No 0.9
No
20
26.57
ATTIC
# Type
Ventilation
Vent Ratio (1 in)
Area
RBS IRCC
1 Full attic
Unvented
0
2046 ftz
N N
9/29/2021 11:11 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
CEILING
F#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Unvented) KITCHEN/DININ
0
Blown
340ft2
0.1
Wood
2
Under Attic (Unvented) GREAT RM
0
Blown
495 ft2
0.1
Wood
3
Under Attic (Unvented) CLST 2
0
Blown
16 ft2
0.1
Wood
4
Under Attic (Unvented) PANTRY
0
Blown
16 ft2
0.1
Wood
5
Under Attic (Unvented) BEDROOM 2
0
Blown
192 ft2
0.1
Wood
6
Under Attic (Unvented) FOYER
0
Blown
88 ft2
0.1
Wood
7
Under Attic (Unvented) AHU CLST
0
Blown
21 ft2
0.1
Wood
8
Under Attic (Unvented) LAUNDRY
0
Blown
100 ft2
0.1
Wood
9
Under Attic (U nvented) HALL
0
Blown
32ft2
0.1
Wood
10
Under Attic (U nvented) BATH
0
Blown
54ft2
0.1
Wood
11
Under Attic (Unvented) CLST 3
0
Blown
18 ft2
0.1
Wood
12
Under Attic (Unvented) BEDROOM 3
0
Blown
156 ft2
0.1
Wood
13
Under Attic (Unvented) MBATH
0
Blown
90ft2
0.1
Wood
14
Under Attic (Unvented) M TOILET
0
Blown
20 ft2
0.1
Wood
15
Under Attic (Unvented) M W IC 2
0
Blown
50 ft2
0.1
Wood
16
Under Attic (Unvented) M WIC 1
0
Blown
36 ft2
0.1
Wood
17
Under Attic (Unvented) MASTER BEDRO
0
Blown
322 ft2
0.1
Wood
WALLS
Adjacent Space Cavity
Width
Height
Sheathing Framing Solar
Below
1
N
Exterior Concrete Block - Int InsuKITCHEN/DI
5
12
0 10
0
120.0 ft2
0
0
0.3
0
2
W
Exterior Concrete Block - Int InsuKITCHEN/DI
5
29
0 10
0
290.0 ft2
0
0
0.3
0
3
N
Exterior Concrete Block - Int InsulGREAT RM
5
18
0 11
0
198.0 ft2
0
0
0.3
0
4
W
Exterior Concrete Block- Int Insul CLST 2
5
2
0 10
0
20.0 ft2
0
0
0.3
0
5
E
Exterior Concrete Block - Int InsiSEDROOM 2
5
9
0 10
0
90.0 ft2
0
0
0.3
0
6
S
Exterior Concrete Block - Int InsuBEDROOM 2
5
12
0 10
0
120.0 ft2
0
0
0.3
0
7
W
Exterior Concrete Block - int InsuBEDROOM 2
5
16
0 10
0
160.0 ft2
0
0
0.3
0
8
S
Exterior Concrete Block - Int Insul FOYER
5
8
0 10
0
80.0 ft2
0
0
0.3
0
9
S
Exterior Concrete Block- Int Insul LAUNDRY
5
10
0 10
0
100.0 ft2
0
0
0.3
0
10
W
Exterior Concrete Block - Int Insul LAUNDRY
5
2
0 10
0
20.0 ft2
0
0
0.3
0
11
E
Garage Frame- Wood LAUNDRY
13
10
0 10
0
100.0 ft2
0
0.1
0.3
0
_ 12
S
Garage Frame- Wood HALL
13
8
0 10
0
80.0 ft2
0
0.1
0.3
0
13
E
Exterior Concrete Block - Int InsiSEDROOM 3
5
13
0 10
0
130.0 ft2
0
0
0.3
0
14
S
Garage Frame - Wood BEDROOM 3
13
12
0 10
0
120.0 f12
0
0.1
0.3
0
15
E
Exterior Concrete Block- Int Insul M BATH
5
11
0 10
0
110.0 ft2
0
0
0.3
0
16
N
Exterior Concrete Block - Int InsuMASTER BE
5
20
0 11
0
220.0 ft2
0
0
0.3
0
17
E
Exterior Concrete Block - Int InsuMASTER BE
5
15
0 11
0
165.0 ft2
0
0
0.3
0
18
W
Exterior Concrete Block - Int InsuMASTER BE
5
9
0 11
0
99.0 ft2
0
0
0.3
0
9/29/2021 11:11 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
DOORS
#
Omt
Door Type
Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
E
Insulated
LAUNDRY None
.23 3
8
24 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
#
Omt
ID Frame
Panes
NFRC
U-Factor SHGC Imp
Area Depth
Separation
Int Shade
Screening
1
N
1 Metal
Low-E Single
Yes
0.65 0.25 Y
30.0 ft2 12 ft 0 in
1 ft 4 in
None
None
2
W
2 Metal
Low-E Single
Yes
0.65 0.25 Y
30.0 ft2 2 ft 0 in
1 ft 4 in
None
None
3
N
3 Metal
Low-E Single
Yes
0.65 0.25 Y
72.0 ft2 12 ft 0 in
1 ft 4 in
None
None
4
S
6 Metal
Low-E Single
Yes
0.65 0.25 Y
20.0 ft2 2 ft 0 in
1 ft 4 In
None
None
5
S
8 Metal
Low-E Single
Yes
0.65 0.25 Y
8.0 1`12 12 ft 0 in
1 ft 4 in
None
None
6
S
8 Metal
Low-E Single
Yes
0.65 0.25 Y
24.0 ft2 12 ft 0 in
1 ft 4 In
None
None
7
S
9 Metal
Low-E Single
Yes
0.65 0.25 Y
15.0 ft2 10 ft 0 in
1 ft 4 in
None
None
8
E
13 Metal
Low-E Single
Yes
0.65 0.25 Y
30.0 ft2 2 It 0 in
1 ft 4 in
None
None
9
E
15 Metal
Low-E Single
Yes
0.65 0.25 Y
8.0 ft2 2 ft 0 in
1 ft 4 in
None
None
10
E
15 Metal
Low-E Single
Yes
0.65 0.25 Y
8.0 ft2 2 ft 0 in
1 ft 4 in
None
None
11
N
16 Metal
Low-E Single
Yes
0.65 0.25 Y
30.0 ft2 2 ft 0 in
1 ft 4 in
None
None
12
E
17 Metal
Low-E Single
Yes
0.65 0.25 Y
10.0 ft2 2 ft 0 in
1 ft 4 in
None
None
13
W
18 Metal
Low-E Single
Yes
0.65 0.26 Y
21.3 ft2 2 ft 0 in
1 ft 4 in
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
832 ft2
832 ft2
30 ft
loft
13
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse
ProposedACH(50)
.00033
1773.1 97.28 182.63 .1002
5
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/
None
COPA
27 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency
Capacity Air Flow
SHR Block
Ducts
1
Central Unit/
Split
Single SEER: 16
35.2 kBtu/hr 1056 cfm
0.8 1
sys#1
9/29/2021 11:11 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 7
FORM RX05-2020
INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# System Type
SubType
Location
EF
Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.98
50 gal
62.3 gal
120 deg .
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System
Model # Collector Model # Area Volume
FEF
None None
ft2
DUCTS
/ — Supply—
— Return—
Air
CFM 25
CFM25
HVAC #
v # Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT QN RLF
Heat Cool
1 Attic
6 150 ft2
Attic
15 ft2
Default Leakage
AHU CLST (Default) c(Default) c
1 1
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
Cooling Jan Feb
Mar
Apr
may
Jun Jul
AugSep
Oct
Nov
Dec
HeatingJan Feb
Mar
Apr
May
Jun Jul
Auge
Oct
Nov
Dec
VentinJan Feb
Mar
Apr
May
Jun Jul
Aug
Sep
Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8
9 10
11
12
Cooling (W D) AM
78
78
78
78
78 78
78
78
80 80
80
80
PM
80
80
80
80
78 78
78
78
78 78
78
78
Cooling (WEH) AM
78
78
78
78
78 78
78
78
80 80
80
80
PM
80
80
80
80
78 78
78
78
78 78
78
78
Heating (W D) AM
65
65
65
65
65 65
65
68
68 68
68
68
PM
68
68
68
68
6B 68
68
68
68 68
68
68
Heating(WEH) AM
65
65
65
65
65 65
65
68
68 68
68
68
PM
68
68
68
68
68 68
68
68
68 68
68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
KITCHEN/DINING
Default(8 Ibs/sq.ft.
ft2
ft
0.3
GREAT RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
PANTRY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
FOYER
Default(8 Ibs/sq.ft.
ft2
ft
0.3
AHU CLST
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALL
Default(8lbs/sq.ft.
ft2
ft
0.3
BATH 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M BATH
Default(8 lbs/sq.ft.
ft2
ft
0.3
M TOILET
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M W IC 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M W IC 1
9/29/2021 11:11 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 7
FORM K405-2020 INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type Area Thickness Furniture Fraction Space
Default 8 Ibs/s .ft. ft2 ft 0.3 MASTER BEDROO
9/29/2021 11:11 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 7 of 7