Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: W ESTCOTT-JACKSON RESIDENCE Builder Name: Street: 5458 SILVER OAK DRIVE Permit Office: CITY OF FORT PIERCE City, State, Zip: FORT PIERCE, FL, 34982 Permit Number: Owner: Jurisdiction: CITY OF FORT PIERCE Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Types(2222.0 sgft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=5.0 1922.00 ft2 b. Frame - Wood, Adjacent R=13.0 300.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 11. Ceiling Types (2046.0 sgft.) Insulation Area 5. Is this a worst case? No a Roof Deck (Unvented) R=20.0 2046.00 f12 6. Conditioned floor area above grade (111:2) 2046 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(306.3 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: AHU CLST R ft2 6 150 a. U-Factor: Sgl, U=0.65 306.33 ft2 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 13. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 35.2 SEER:16.00 c. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 6.766 ft. 14. Heating systems kBtu/Efficiency Area Weighted Average SHGC: 0.250 a. Electric Strip Heat 27.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A fN 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (2046.0 sgft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 2046.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits None Glass/Floor Area: 0.150 Total Proposed Modified Loads: 66.84 PASS Total Baseline Loads: 67.99 1 hereby certify that the plans and specifications covered by Review of the plans and TIJE ST.gT this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance no with the Florida Energy Code. PREPARED DATE:. - - Before construction is completed this building will be inspected for tv compliance with Section 553.908 I h r certify that this bu' in designed, is in compliance Florida Statutes. 1,t; wit . the F ' Energy C de. GDD >v OW R/AGENT: BUILDING OFFICIAL: DATE: DATE: i - Compliance requires certification by t e air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 9/29/2021 11:11 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT ' PROJECT Title: WESTCOTT-JACKSON REST Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2046 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name. Rotate Angle: 0 Street: 5458 SILVER OAK DRI Permit Office: CITY OF FORT PIERCE Cross Ventilation: No County. St. Lucie Jurisdiction: CITY OF FORT PIERCE Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Detached FL, 34982 New/E)asting: New (From Plans) Comment: CLIMATE v Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2046 21277 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 KITCHEN/DINING 340 3400 Yes 0 1 Yes Yes Yes 2 GREAT RM 495 5445 No 0 1 Yes Yes Yes 3 CLST 2 16 160 No 0 1 Yes Yes Yes 4 PANTRY 16 160 No 0 1 No Yes Yes 5 BEDROOM 2 192 1920 No 0 1 1 Yes Yes Yes 6 FOYER 88 880 No 0 1 Yes Yes Yes 7 AHU CLST 21 210 No 0 1 No Yes Yes 8 LAUNDRY 100 1000 No 0 1 Yes Yes Yes 9 HALL 32 320 No 0 1 No Yes Yes 10 BATH 2 54 540 No 0 1 No Yes Yes 11 CLST 3 18 180 No 0 1 No Yes Yes 12 BEDROOM 3 156 1560 No 0 1 1 Yes Yes Yes 13 M BATH 90 900 No 0 1 Yes Yes Yes 14 M TOILET 20 200 No 0 1 No Yes Yes 15 M WIC 2 50 500 No 0 1 No Yes Yes 16 M WIC 1 36 360 No 0 1 No Yes Yes 17 MASTER BEDROO 322 3542 No 0 1 1 Yes Yes Yes 9/29/2021 11:11 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation KITCHENIDININ 41 ft 340 ftz 1 0 0 2 Slab -On -Grade Edge Insulation GREAT RM 18 ft 495 ftz __ 1 0 0 3 Slab -On -Grade Edge Insulation CLST 2 2 ft 16 ftz __ 1 0 0 4 Slab -On -Grade Edge Insulation PANTRY 1 ft 16 ftz ___ 1 0 0 5 Slab -On -Grade Edge Insulation BEDROOM 2 37 ft 192 ftz 1 0 0 6 Slab -On -Grade Edge Insulation FOYER 8 ft 88 ftz 1 0 0 7 Slab -On -Grade Edge Insulation AHU CLST 1 ft 21 ftz -_ 1 0 0 8 Slab -On -Grade Edge Insulation LAUNDRY 12 ft 100 ftz 1 0 0 9 Slab -On -Grade Edge Insulation HALL 1 ft 32 ftz ____ 1 0 0 10SIab-On-Grade Edge Insulation BATH 2 1 ft 54 ftz 1 0 0 11Slab-On-Grade Edge Insulation CLST 3 1 ft 18 ftz 1 0 0 12SIab-On-Grade Edge Insulation BEDROOM 3 13 ft 156 ftz ___ 1 0 0 13SIab-On-Grade Edge Insulation M BATH lift 90 ftz ____ 1 0 0 14SIab-On-Grade Edge Insulation M TOILET 1 ft 20 ftz __ 1 0 0 15SIab-On-Grade Edge Insulation M W IC 2 1 ft 50 ftz 1 0 0 16SIab-On-Grade Edge Insulation M W IC 1 1 ft 36 ftz 1 0 0 17SIab-On-Grade Edge Insulation MASTER BEDRO 44 ft 322 ftz __ 1 0 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 2288 ftz 0 ftz Light N 0.3 No 0.9 No 20 26.57 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2046 ftz N N 9/29/2021 11:11 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT CEILING F# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) KITCHEN/DININ 0 Blown 340ft2 0.1 Wood 2 Under Attic (Unvented) GREAT RM 0 Blown 495 ft2 0.1 Wood 3 Under Attic (Unvented) CLST 2 0 Blown 16 ft2 0.1 Wood 4 Under Attic (Unvented) PANTRY 0 Blown 16 ft2 0.1 Wood 5 Under Attic (Unvented) BEDROOM 2 0 Blown 192 ft2 0.1 Wood 6 Under Attic (Unvented) FOYER 0 Blown 88 ft2 0.1 Wood 7 Under Attic (Unvented) AHU CLST 0 Blown 21 ft2 0.1 Wood 8 Under Attic (Unvented) LAUNDRY 0 Blown 100 ft2 0.1 Wood 9 Under Attic (U nvented) HALL 0 Blown 32ft2 0.1 Wood 10 Under Attic (U nvented) BATH 0 Blown 54ft2 0.1 Wood 11 Under Attic (Unvented) CLST 3 0 Blown 18 ft2 0.1 Wood 12 Under Attic (Unvented) BEDROOM 3 0 Blown 156 ft2 0.1 Wood 13 Under Attic (Unvented) MBATH 0 Blown 90ft2 0.1 Wood 14 Under Attic (Unvented) M TOILET 0 Blown 20 ft2 0.1 Wood 15 Under Attic (Unvented) M W IC 2 0 Blown 50 ft2 0.1 Wood 16 Under Attic (Unvented) M WIC 1 0 Blown 36 ft2 0.1 Wood 17 Under Attic (Unvented) MASTER BEDRO 0 Blown 322 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N Exterior Concrete Block - Int InsuKITCHEN/DI 5 12 0 10 0 120.0 ft2 0 0 0.3 0 2 W Exterior Concrete Block - Int InsuKITCHEN/DI 5 29 0 10 0 290.0 ft2 0 0 0.3 0 3 N Exterior Concrete Block - Int InsulGREAT RM 5 18 0 11 0 198.0 ft2 0 0 0.3 0 4 W Exterior Concrete Block- Int Insul CLST 2 5 2 0 10 0 20.0 ft2 0 0 0.3 0 5 E Exterior Concrete Block - Int InsiSEDROOM 2 5 9 0 10 0 90.0 ft2 0 0 0.3 0 6 S Exterior Concrete Block - Int InsuBEDROOM 2 5 12 0 10 0 120.0 ft2 0 0 0.3 0 7 W Exterior Concrete Block - int InsuBEDROOM 2 5 16 0 10 0 160.0 ft2 0 0 0.3 0 8 S Exterior Concrete Block - Int Insul FOYER 5 8 0 10 0 80.0 ft2 0 0 0.3 0 9 S Exterior Concrete Block- Int Insul LAUNDRY 5 10 0 10 0 100.0 ft2 0 0 0.3 0 10 W Exterior Concrete Block - Int Insul LAUNDRY 5 2 0 10 0 20.0 ft2 0 0 0.3 0 11 E Garage Frame- Wood LAUNDRY 13 10 0 10 0 100.0 ft2 0 0.1 0.3 0 _ 12 S Garage Frame- Wood HALL 13 8 0 10 0 80.0 ft2 0 0.1 0.3 0 13 E Exterior Concrete Block - Int InsiSEDROOM 3 5 13 0 10 0 130.0 ft2 0 0 0.3 0 14 S Garage Frame - Wood BEDROOM 3 13 12 0 10 0 120.0 f12 0 0.1 0.3 0 15 E Exterior Concrete Block- Int Insul M BATH 5 11 0 10 0 110.0 ft2 0 0 0.3 0 16 N Exterior Concrete Block - Int InsuMASTER BE 5 20 0 11 0 220.0 ft2 0 0 0.3 0 17 E Exterior Concrete Block - Int InsuMASTER BE 5 15 0 11 0 165.0 ft2 0 0 0.3 0 18 W Exterior Concrete Block - Int InsuMASTER BE 5 9 0 11 0 99.0 ft2 0 0 0.3 0 9/29/2021 11:11 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Insulated LAUNDRY None .23 3 8 24 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Metal Low-E Single Yes 0.65 0.25 Y 30.0 ft2 12 ft 0 in 1 ft 4 in None None 2 W 2 Metal Low-E Single Yes 0.65 0.25 Y 30.0 ft2 2 ft 0 in 1 ft 4 in None None 3 N 3 Metal Low-E Single Yes 0.65 0.25 Y 72.0 ft2 12 ft 0 in 1 ft 4 in None None 4 S 6 Metal Low-E Single Yes 0.65 0.25 Y 20.0 ft2 2 ft 0 in 1 ft 4 In None None 5 S 8 Metal Low-E Single Yes 0.65 0.25 Y 8.0 1`12 12 ft 0 in 1 ft 4 in None None 6 S 8 Metal Low-E Single Yes 0.65 0.25 Y 24.0 ft2 12 ft 0 in 1 ft 4 In None None 7 S 9 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft2 10 ft 0 in 1 ft 4 in None None 8 E 13 Metal Low-E Single Yes 0.65 0.25 Y 30.0 ft2 2 It 0 in 1 ft 4 in None None 9 E 15 Metal Low-E Single Yes 0.65 0.25 Y 8.0 ft2 2 ft 0 in 1 ft 4 in None None 10 E 15 Metal Low-E Single Yes 0.65 0.25 Y 8.0 ft2 2 ft 0 in 1 ft 4 in None None 11 N 16 Metal Low-E Single Yes 0.65 0.25 Y 30.0 ft2 2 ft 0 in 1 ft 4 in None None 12 E 17 Metal Low-E Single Yes 0.65 0.25 Y 10.0 ft2 2 ft 0 in 1 ft 4 in None None 13 W 18 Metal Low-E Single Yes 0.65 0.26 Y 21.3 ft2 2 ft 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 832 ft2 832 ft2 30 ft loft 13 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .00033 1773.1 97.28 182.63 .1002 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 16 35.2 kBtu/hr 1056 cfm 0.8 1 sys#1 9/29/2021 11:11 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 7 FORM RX05-2020 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg . None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / — Supply— — Return— Air CFM 25 CFM25 HVAC # v # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 150 ft2 Attic 15 ft2 Default Leakage AHU CLST (Default) c(Default) c 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling Jan Feb Mar Apr may Jun Jul AugSep Oct Nov Dec HeatingJan Feb Mar Apr May Jun Jul Auge Oct Nov Dec VentinJan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (W D) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (W D) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 6B 68 68 68 68 68 68 68 Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 KITCHEN/DINING Default(8 Ibs/sq.ft. ft2 ft 0.3 GREAT RM Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 PANTRY Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 FOYER Default(8 Ibs/sq.ft. ft2 ft 0.3 AHU CLST Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 Ibs/sq.ft. ft2 ft 0.3 HALL Default(8lbs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 M BATH Default(8 lbs/sq.ft. ft2 ft 0.3 M TOILET Default(8 Ibs/sq.ft. ft2 ft 0.3 M W IC 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 M W IC 1 9/29/2021 11:11 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 7 FORM K405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. ft2 ft 0.3 MASTER BEDROO 9/29/2021 11:11 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 7 of 7