Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFING12/14/21, 10:13 PM Florida Building Code Online https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqsKQFEnckB107lJGi1ioIYqdSepo1aWOZlCDw56hlzFHg%3d%3d 1/4 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL25621-R2 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Extreme Metal Fabricators, LLC Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 flvalidation@yahoo.com Authorized Signature Richard McKuhen flvalidation@yahoo.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report David Eng Florida License PE-81377 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 04/22/2024 Validated By James R Wally, PE Validation Checklist - Hardcopy Received Certificate of Independence FL25621_R2_COI_26ga_SnapMax_plywood.pdf Referenced Standard and Year (of Standard)Standard Year TAS 100 1995 TAS 125 2003 UL 580 2006 Equivalence of Product Standards Certified By Sections from the Code 12/14/21, 10:13 PM Florida Building Code Online https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqsKQFEnckB107lJGi1ioIYqdSepo1aWOZlCDw56hlzFHg%3d%3d 2/4 Product Approval Method Method 1 Option D Date Submitted 12/16/2020 Date Validated 12/17/2020 Date Pending FBC Approval 12/26/2020 Date Approved 02/09/2021 Summary of Products FL #Model, Number or Name Description 25621.1 01: 26ga SnapMax on Plywood 26ga (min) SnapMax 1.0" nail strip on 15/32" (min) plywood or 3/4" (min) wood plank Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-97.25 Other: Refer to evaluation report Installation Instructions FL25621_R2_II_26ga_SnapMax_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL25621_R2_AE_26ga_SnapMax_plywood.pdf Created by Independent Third Party: Yes 25621.2 02: 032 Aluminum SnapMax on Plywood Nominally 0.032" aluminum (or thicker) SnapMax 1.0" nail strip on 15/32" (min) plywood or 3/4" wood plank Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-78.5 Other: Refer to evaluation report Installation Instructions FL25621_R2_II_032_SnapMax_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL25621_R2_AE_032_SnapMax_plywood.pdf Created by Independent Third Party: Yes 25621.3 03: 032 Aluminum 12" SnapMax on Plywood Nominally 0.032" aluminum (or thicker) SnapMax 1.0" nail strip with 12" coverage on 15/32" (min) plywood or 3/4" wood plank Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-69.25 Other: Refer to evaluation report Installation Instructions FL25621_R2_II_032_SnapMax_12in_Plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL25621_R2_AE_032_SnapMax_12in_Plywood.pdf Created by Independent Third Party: Yes 25621.4 04: 26ga SnapMax on Plywood 26ga (min) SnapMax 1.0" nail strip on 15/32" (min) plywood or 3/4" (min) wood plank Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-121.75 Other: Refer to evaluation report Installation Instructions FL25621_R2_II_26ga_SnapMax_plywood_D.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL25621_R2_AE_26ga_SnapMax_plywood_D.pdf Created by Independent Third Party: Yes 25621.5 05: 26ga SnapMax on Plywood HVHZ 26ga (min) SnapMax 1.0" nail strip on 15/32" (min) plywood or 3/4" (min) wood plank Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-176 Other: Refer to evaluation report Installation Instructions FL25621_R2_II_26ga_SnapMax_plywood_HVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL25621_R2_AE_26ga_SnapMax_plywood_HVHZ.pdf Created by Independent Third Party: Yes 25621.6 06: 24ga SnapMax on Plywood 24ga (min) SnapMax 1.0" nail strip on 15/32" (min) plywood or 3/4" (min) wood plank Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-206 Other: Refer to evaluation report Installation Instructions FL25621_R2_II_24ga_SnapMax_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL25621_R2_AE_24ga_SnapMax_plywood.pdf Created by Independent Third Party: Yes 25621.7 07: 032 Aluminum SnapMax on Plywood Nominally 0.032" aluminum (or thicker) SnapMax 1.0" nail strip on 15/32" (min) plywood or 3/4" wood plank Limits of Use Approved for use in HVHZ: No Installation Instructions FL25621_R2_II_032_SnapMax_plywood_d.pdf 12/14/21, 10:13 PM Florida Building Code Online https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqsKQFEnckB107lJGi1ioIYqdSepo1aWOZlCDw56hlzFHg%3d%3d 3/4 Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-168.5 Other: Refer to evaluation report Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL25621_R2_AE_032_SnapMax_plywood_d.pdf Created by Independent Third Party: Yes 25621.8 08: 032 Aluminum SnapMax on Plywood HVHZ Nominally 0.032" aluminum (or thicker) SnapMax 1.0" nail strip on 15/32" (min) plywood or 3/4" wood plank Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-175 Other: Refer to evaluation report Installation Instructions FL25621_R2_II_032_SnapMax_plywood_HVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL25621_R2_AE_032_SnapMax_plywood_HVHZ.pdf Created by Independent Third Party: Yes 25621.9 09: 26ga 19" TopMax on Plywood 26ga (min) TopMax 1.5" nail strip with 19" coverage on 15/32" (min) plywood or 3/4" (min) wood plank Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-63.5 Other: Refer to evaluation report Installation Instructions FL25621_R2_II_26ga_TopMax_19in_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL25621_R2_AE_26ga_TopMax_19in_plywood.pdf Created by Independent Third Party: Yes 25621.10 10: 032 Aluminum TopMax on plywood HVHZ Nominally 0.032" aluminum (or thicker) TopMax 1.5" nail strip on 15/32" (min) plywood or 3/4" wood plank Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-179.5 Other: Refer to evaluation report Installation Instructions FL25621_R2_II_032_TopMax_plywood_HVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL25621_R2_AE_032_TopMax_plywood_HVHZ.pdf Created by Independent Third Party: Yes 25621.11 11: 24ga TopMax on Plywood HVHZ 24ga (min) TopMax 1.5" nail strip on 15/32" (min) plywood or 3/4" (min) wood plank Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-153.5 Other: Refer to evaluation report Installation Instructions FL25621_R2_II_24ga_TopMax_plywood_HVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL25621_R2_AE_24ga_TopMax_plywood_HVHZ.pdf Created by Independent Third Party: Yes 25621.12 12: 24ga 19" TopMax on Plywood HVHZ 24ga (min) TopMax 1.5" nail strip with 19" coverage on 15/32" (min) plywood or 3/4" (min) wood plank Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.25 Other: Refer to evaluation report Installation Instructions FL25621_R2_II_24ga_TopMax_19in_plywood_HVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL25621_R2_AE_24ga_TopMax_19in_plywood_HVHZ.pdf Created by Independent Third Party: Yes 25621.13 13: 032 Aluminum 19" TopMax on plywood HVHZ Nominally 0.032" aluminum (or thicker) TopMax 1.5" nail strip with 19" coverage on 15/32" (min) plywood or 3/4" (min) wood plank Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-166.75 Other: Refer to evaluation report Installation Instructions FL25621_R2_II_032_TopMax_19in_plywood_HVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL25621_R2_AE_032_TopMax_19in_plywood_HVHZ.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails 12/14/21, 10:13 PM Florida Building Code Online https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqsKQFEnckB107lJGi1ioIYqdSepo1aWOZlCDw56hlzFHg%3d%3d 4/4 provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: