FL # FL17022-R9
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
11
Extreme Metal Fabricators, LLC
2160 SW Poma Drive
Palm City, FL 34990
(772)872-8034
flvalidation@yahoo.com
Richard McKuhen
flvalidation@yahoo.com
Richard McKuhen
2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
richard@emfab.net
Roofing
Metal Roofing
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
0 Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the David Eng
Evaluation Report
Florida License PE-81377
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By James R Wally, PE
0 Validation Checklist - Hardcopy Received
Certificate of Independence FL17022 R9 COI 26ga VMAX 12lywood. ddff
Referenced Standard and Year (of Standard) Standard Year
TAS 100 1995
TAS 125 2003
UL 580 2006
Equivalence of Product Standards
file:IIICIUsers/Mauricio/OneDrive/DesktopIProduct%20approvals%20202215V%a20metaIlCover%20page.hhnl[1212612021 5:37:09 PK
Florida Building Code Online
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
12/16/2020
Date Validated
12/16/2020
Date Pending FBC Approval
12/26/2020
Date Approved
02/09/2021
Summary of Products
FL # Model, Number or Name Description
17022.1 _ JG - 26ga VMax on Plywood 126ga (min) VMax 5V panel with 24" coverage on 15/32" (min)
Plywood or 3/4" (min) thick wood plank.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17022 R9 II 26oa VMAX j2lywood.pdf
Approved for use outside HVHZ: Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-228 Evaluation Reports
" Other: Refer to evaluation report. FL17022 R9 AE 26ga VMAX plywood pdf
Created by Independent Third Party: Yes
17022.2 �Y02: 032 Aluminum VMax on Plywood Nominally 0.032" aluminum (or thicker) VMax 5V panel with
21" coverage on 15/32" (min) plywood or 3/4" (min) thick
wood plank.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17022 R9 II 032 VMAX 21in p> ywood pdf
Approved for use outside HVHZ: Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-168.5 Evaluation Reports
Other: Refer to evaluation report. FL17022 R9 AE 032 VMAX 21 in ;wood pdf
Created by Independent Third Party: Yes
17022.3 03: 26ga VMax on Plywood
26ga (min) VMax 5V panel with 24" coverage on 15/32" (min)
plywood or 3/4" (min) thick wood plank. Option for fasteners in
the flats and in the ribs.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R9 I1 26oa VMAX olvwood flats pdf
Approved for use outside HVHZ: Yes
Verified By: David Eng, PE 81377
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-114.25
Evaluation Reports
Other: Refer to evaluation report.
FL17022 R9 AE 26ga VMAX olvwood flats odf
Created by Independent Third Party: Yes
17022.4
04: 26ga CorMax on Plywood
26ga (min) CorMax corrugated panel with 29.5" coverage on
15/32" (min) plywood or 3/4" (min) thick wood plank.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL17022 R9 II 26aa CorMax Plywood HVHZ odf
Verified By: David Eng, PE 81377
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-161
Evaluation Reports
Other: Refer to evaluation report.
FL17022 R9 AE 26ga CorMax Plywood HVHZ pdf
by Third Party: Yes
Created Independent
17022.5
05: 26ga CorMax on Battens
26ga (min) CorMax corrugated panel with 29.5" coverage on
2x4 (min) battens.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R9 II 26ga CorMax Battens.pdf
Approved for use outside HVHZ: Yes
Verified By: David Eng, PE 81377
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-161
Evaluation Reports j
Other: Refer to evaluation report.
EL17022 R9 AE 26ga CorMax Battens pdf
i Created by Independent Third Party: Yes
_-
file:IIICIUsers/Mauricio/OneDrive/DesktopIProduct%20approvals%20202215V%20metallCover%20page.html[1212612021 5:37:09 PM]
EXTREMEMETAL
FABRICATORS
SKIUSO CRAFTERS OF METAL ROOFING SYSTEMS
26ga (min) VMAX over 15/32" (min) plywood
Extreme Metal Fabricators
2160 SW Poma Dr I Palm City FL 34990
Product Description
5V Crimp style exposed fastener panel with 24" max coverage and nominal
rib height of 3/8".
Product Material
26ga (min) steel
Corrosion resistant per FBC 1507.4.3 where required
Fastener
#9 or #10 x 1.5" fastener with sealing washer
Compliant with FBC 1506.6 where required.
Substrate/Deck
15/32" (min) plywood or
3/4" (min) thick wood plank (min S.G. of 0.42)
Evaluated by:
David Eng, PE
Timberlake Cove, LLC
3324 W Univ Ave #206 1 Gainesville FL
FL PE 81377 1 FL CA 33344
www.TimberLakeCove.com
MAX
L17022.01
Instructions:
Select the appropriate load table that applies to the
structure in question.
Determine the design wind speed for the project
location.
Use the attachment method indicated for that
windspeed within each roof zone.
NOTE: ASCE 7-16 and FBC 2020 adopt a 7-zone concept.
For the load tables below, the worst case was taken
for each zone and reported using the standard zones
1-2-3:
Zone 1 includes zones 1 and 1'
Zone 2 includes zones 2e, 2r, and 2n
Zone 3 includes zones 3e and 3r
Combining these zones creates a clear, simple
scheme, at the expense of some design efficiency.
Contact the manufacturer for further information,
or consult a licensed design professional.
METHOD A:
#9 AT 16" O_C.
-,,"--a
a. 10 %OF LEASTHORONTAL DIMENSION OR 0 4n, WAICI IEVER IS SMALLER. BUT NOT
LE$S THAN EHHER 4°�, OF LEAST HORIZONTAL DIMENBION OR 3FT (0.9Ai1.
OR AS DETERMINED BY DESIGN OR OTHER APPLICABLE CODE.
ROOF ZONES FOR GENERIC BUILDING
METHOD B: METHOD C: METHOD D:
#10 AT 16" O.C. #10 AT 8" O.C. #10 AT 6" O.C.
�-12" (NOM) 12" (NOM)I NR: NOT RATED. CONSULT DESIGN
PROFESSIONAL AS NEEDED
Use this load table for structures which meet the following criteria:
Are located in Exposure B area
Have either a flat roof, or gable/hip roof with max slope of 12:12
Have a mean Roof Height of 30 feet or less
Use this load table for structures which meet the following criteria:
Are located in B, C, or D exposure area
Have either a flat roof, or gable/hip roof with max slope of 12:12
Have a mean Roof Height of 30 feet or less
ITL17022.01. 26
a 5V Crimig
on 15132" 12lywood
FL17022.01: 26
a 5V Crim12
on 15/32" plywood
Wind 105 110
120 130 140
150
160
170
180 190 200
Wind 105 110
120
130
140 150
160
170
180 190 200
Zone 1: A A
A
A A
A
A
A
A A A
Zone 1: A A
A
A
A
A
A
C
D D D
Zone 2: A A
A
A A
A
A
A
C D D
Zone 2: A A
A
A
C
D
D
D
D D D
Zone 3: A A
A
A A
A
B
C
D D D
Zone 3: AAA
C
DDDDDDJM
Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria.
Are located in Exposure B area Are located in B, C, or D exposure area
Have either a flat roof less than 7', hip roof with Have either a flat roof less than 70, hip roof with
max slope of 12:12, or gable roof with slope between 4.4:12 & 12:12 max slope of 12:12, or gable roof with slope between 4.4:12 & 12:12
Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less
Cl A7nOO nd. )a-- c\/ _.. ........... .... — — .
Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 170 180 190 200
Zone 1: A A A A A A A A A A A Zone 1: A A A A A A A B C 1. D D
Zone 2: A A A A A A A A A B C Zone 2: A A A A A B D D D D D
Zone 3_ A A_ A A A A A B D D D Zone 3: AAA B DDDDDDD
Underlayment: Comply with local building code or FBC 1507.1.1 where required.
Slope: Comply with local building code or FBC 1507.4.2 where required.
Re -Roofing: This panel may be installed over a single layer of existing shingles as permitted
by local building code or FBC 1511, provided the existing roof meets the conditions required by
the applicable code.
Maximum Allowable Loads & Installation Requirements:
Method A: #9 x 1.5" fastener in 12"-12" pattern at 16" o.c.: 86 PSF
Method B: #10 x 1.5" fastener in 12"-12" pattern at 16" o.c.: 93.5 PSF
Method C: #10 x 1.5" fastener in 12"-12" tattern at 8" o.c.: 101 PSF
Method D: #10 x 1.5" fastener in 12"-12" pattern at 6" o.c.: 228 PSF
A factor of safety of 2 has been applied.
Technical Documentation:
This product has been tested to the UL 580 standard by Architectural Testing (now Intertek
Testing, TST-1527), report D05893.01-450-18, F3366.01-450-18, and D05893.02-450-18. As referenced in
FL 17022.01-R7
Compliance Statement:
This product as described has demonstrated compliance with Florida Building Code 2020,
1504.3.2 (non-HVHZ) as required by FL Rule 61G20-3, method 1D.
This product as described has been tested and demonstrated compliance with:
• UL580 - Test for Uplift Resistance of Roof Assemblies
• UL 1897 - Uplift test for roof covering systems
Design Process:
The load tables in this report provides one prescriptive option for the fastening requirement
for the applicable wind loads for roofs within the parameters described. For roofs outside of
the listed parameters, design wind loads shall be determined as required by FBC 1609, ASCE 7, or
other design code in force, using allowable stress. These load tables are based on ASCE 7-16.
Use of these tables assumes that the structure is:
• Enclosed and conforms to wind-borne debris provisions and is a regular shaped building
• Is not subject to across -wind loading, vortex shedding, or instability; nor does it have a
site location for which channeling or buffeting warrant consideration
Engineering analysis may be completed by other licensed engineers for project specific
approval by local authorities having jurisdiction.
Certification of Independence:
David Eng, PE and Timberlake Cove, LLC do not have, nor will acquire a financial interest in any company
manufacturing or distributing products under this evaluation. The some entities do not have, nor will
acquire, a financial interest in any other entity involved in the approval process of the product.
Exclusions and Limitations:
Design of deck and roof structure (to include attachment of plywood or wood plank) shall be completed by
others. Fire classification and shear diaphragm design are outside the scope of this evaluation. Accelerated
weathering/salt spray is outside the scope of this evaluation.
This report is limited to compliance with structural wind load requirements of FBC 1504.3.2, as required by
Rule 61G20-3. Neither Timberlake Cove nor the manufacturer shall be responsible for any conclusions,
interpretations, or designs made by others based on this evaluation report. This report is limited solely to
documenting compliance with Rule 61G20-3, and makes no express or implied warranty regarding
performance of this product. Installation shall be subject to the local building code and authority having
jurisdiction; this report shall not be construed to supersede local codes in force.