HomeMy WebLinkAboutROOFING PERMIT INFORMATION SHEETLL , c- r
ST. LUCIE WORKS
ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET
Florida Building Code 7th Edition (202-0)
Based on Section 1525 of the Florida Building Code - Building
INSTRUCTION PAGE
COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET
APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED
BELOW:
Roof System
Required Sections of
the Permit Application
Farm
Attachments Required
See Fist Below
Low Slope Application
A, B, C
1,2,3,4,5,6,7 .
Prescriptive BUR-RAS 150
A, B, C
2,4,5,6,7
Asphaltic Shingles
A, B, D
12,4,5,6,7
Concrete or Clay Tile
A, B, D, E
1,2,3,4,5,6,7
Metal Roofs
A, B, ❑
Wood Shingles and
Shakes
A, B, D
{A4.6,6,7
Other
As Applicable
1,2,3,4,5,6,7
ATTACHMENTS REQUIRED As Applicable):
1.
Fire Directory Listing Page
2.
From Product Approval:
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
3.
Design Calculations per Chapter 76, or if applicable, RAS 127 or RAS 128
4.
Other Component of Product Approval
5,
Municipal Permit Application
6.
Owners Notification for Roofing Considerations (Reroofing only)
7.
Any Required Roof Testing/Calculation Documentation
Form RooflnfoFeb21 Rev Feb 18, 2021
ST. LUCIE WORKS
Section C (Low Slope Roof)
Fill in specific roof assembly components and identify
manufacturer
(If a component is not used, identify as "NA")
System Manufacturer:
Product Approval
Design Wind Pressures, From RAS 128 Or Calculations:
Zone 1': Zone 1:_ Zone 2: _Zone 3:
Max. Design Pressure, from the specific product approval
Deck:
Gauge Thickness:
Slope:
Anchor/Base Sheet & No. df Ply(s):
Anchor/Base Sheet Fastener/Bonding Material:
Insulation Base layer:
Base Insultation Size and Thickness:
Base Insulation Fastener/Bonding Material:
Top Insulation Layer:
Top Insulation Size and Thickness:
Top Insulation Fastener/Bonding Material:
Base Sheets) & No. of Ply(s):
Base Sheet Fastener/Bonding Material:
Ply Sheet(s)' & No. of Ply(s):
Ply Sheet Fastener/Bonding Material:
Top Ply:
Top Ply Fastener/Bonding Material:
Surfacing:
Fastener Spacing for Anchor/Base Sheet Attachment:
Zone 1':_" oc @ Lap, # Rows—® — oa
Zone 1:_" oc @ Lap, # Rows — ® —' oc
Zone 2:—" oc @ Lap, # Rows _ ®_' =
Zone 3:—" oc @ Lap, # Rows— ® ac
Number of Fasteners Per Insulation Board:
Zone 1':_Zone 1_Zone 2—Zone 3:_
Illustrate Components Noted and Details as Applicable:
Woodblocking, Gutter, Edge Termination, Stripping,
Flashing, Continuous Cleat, Cant Strip, Base Flashing,
Counterflashing, Coping, Etc.,
Indicate: Mean Roof Height, Parapet Height, Height of Base
Flashing, Component Material, Material' Thickness, Fastener
Type, Fastener Spacing or Submit Manufacturers Details that
Comply with RAS ill and Chapter 16..
ST. LUCIE WORKS
Section D (Steep Slope Roof System)
Root system Manufacturer: JA TAYLOR ROOFING 5V CRIMP
Notice of Acceptance Number: FL#17443.1
Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations):
Zone 1: -57 Zone 2e: -101 Zone 2n:one 2r: -98 Zone 3e-128 Zone 3r:
Deck Type: PLYWOOD
Roof Slope; EEL & S7 Type Underlayment P1CK-OWENS CORNING POLYGLASS MTS FL#5259.1
fi : 12
- Insulation:
Fire Barrier:
Ridge Ventilation? Fastener Type & Spacing: E" FIELD 1 4" PERIMETER, 8D RING SHANK NAILS
Adhesive Type:
Type Cap Sheet:
Mean Roof Height: 15' FT Roof Covering: METAL
Type & Size Drip 2„ xZ„
Edge:
ST. LUGIE WORKS
Section E (Tile Calculations)
For Moment based tile systems, choose either Method 1 or 2. Compare the values for Mr with the values from Mr. If the Mr values
are greater than or equal to the Mrvalues, for each area of the roof, then the tile attachment method is acceptable.
Method 1'Moment Based Tile Calculations Per RAS 12T
(Zone 1: _X),_=- I-Mg_=p,_ Product ApprovalM
(Zone 2e: -x lM_=fY4y_ Product Approval Mr
(Zone 2n: _xll_=-ffP_=M., Product Approval Mr
(Zone 2r. _X%_= _�-Mg: M,,_ Product Approval Mr
(Zone 3e: ;_XX_= I-(yT III- Product Approval Mr
(Zone 3r: _X)L_= _J-fy♦g- Mar_ Product Approval Mr
Method 2 "Simplified Tile Calculations Per Table Below"
Required Moment of Resistance (Mr) From Table Below- Produa AuurovaI Mc -
Mr required Moment Resistance -
Mean Roof Height Roof Slope
15,
2o'
25'
30'
40'
2:12
34.4
36.5
38.2
39.7
42.2
3:12
32.2
34.4
36.0
37.4
39.8
4:12
30.4
32.2
33.8
35.1
37.3
5:12
28.4
30.1
31.6
32.8
34.9
6:12
26.4
28.0
29.4
30.5
32.4
7
24.4
25.9
27.1
28.2
30.0
-must be used in conjunction wnn a list or moment based tile systems
• For Uplift based tile systems use Method 3. Compare the values for F' with the values for Fr If the F'values are greater than or
equal to the Frvalues, for each area of the roof, then the tile attachment method is acceptable.
Method 3 "Uplift Based Tile Calculations Per RAS 12T
(Zone 1: x L= x W:=_) -W: cos r=F,i Product Approval F'
(Zone 2e:xL =x W:=_)-W: cos r_ F,1e_ Product Approval F'
(Zone 2n: xL=xW:=�-W: Cos r=F,m Product Approval F'
(Zone 2r x L =x W:=-W:_cos r_-Frir Product Approval F'
(Zone 3e:x L_=x W:=_)-W:cos r=F3. Product Approval F'
(Zone 3r: _x L =x W:=_� -W:_ cos r F,s, Product Approval r
Where to Obtain Information
Description
Symbol
Where to find
Design
g
Zones 1, 2e, 2q 2q 3e, 3r
From applicable table in RAS 127 or by an engineering analysis
prepared by PE based on ASCE 7
Mean Roof Height
H
Job Site
Roof Slope
R
lob Site
Aerodynamic Multiplier
a
Product Approval
Restoring Moment due to Gravity
Mg
Product Approval
Attachment Resistance
Mf
Product Approval
Required Moment Resistance
Mt
Calculated
Minimum Attachment Resistance
P
Product Approval
Required Uplift Resistance
Fr
Calculated
Average Tile Weight
W
Product Approval
Tile Dimensions
L=length W=width
Product Approval
All calculations must be submitted to the building official at the time of permit application.