Loading...
HomeMy WebLinkAboutInspection CardInspection Card Planning &Development Services Permit # : 2010-0290 Building & Code Regulation Division Online address: 2300 Virginia Avenue http://www.stlucieQuick Links:ing/permitting.htm Fort Pierce, FL. 34982 Quick Links: Permit Status Lookup Phone:(772)462-2172 Fax:(772)462-6443 Online Building Inspection System Permit# Issued: Job Location: Jurisdiction: Subdivision: Flood: Set backs: Job Description SLC- 2010-0290 2/9/2021 980 Gopher Ridge Rd SAINT LUCIE COUNTY J A SMITH'S S/D X Elev: Left: Right: 17.00 New Swimming Pool With Spa And Travetine Deck Owner Builder Salvador Garcia Jr 5901 Balsam Dr Property Owner Salvador Garcia Jr 5901 Balsam Dr Property Owner Savannah L Garcia 5901 Balsam Dr Confirmation 111 Type: POOUSPA - RESIDENTIAL City: Fort Pierce Parcel: 3404-805-0024-000/4 Lot: 24 Block: Flood Map: Fort Pierce, FL 34982 Fort Pierce, FL 34982 Fort Pierce, FL 34982 Front: SUB -PERMITS Permit No Status Permit Type Cert # DBA 2010-0290-01 Void ELECTRIC - RESIDENTIAL 30980 All Power Electric Contracting Llc 2010-0290-02 Void 2010-0290-03 Issued 2010-0290-04 Issued PLUMBING - RESIDENTIAL PLUMBING - POOLS ELECTRIC - RESIDENTIAL 31198 Amore Pools Inc Status ISS Rear: 187.60 (772) 359-7418 (772) 359-7418 Owner/Builder SALVADOR GARCIA JR SALVADOR GARCIA JR Go to.http://codeinsr)ectionpublic.stlucieco.gov to schedule online. For the Automated inspection system call (866) 284-1280. All inspections requested prior to 9:00 PM will be scheduled for the next business day. Inspection requests between 9:00 PM Friday and 9:00 PM Monday will be scheduled for the following Tuesday. If you require any assistance please contact the Building Department at (772) 462-1574. YOU ARE REQUIRED TO REQUEST INSPECTIONS IN THE ORDER THEY ARE LISTED I3ELOW UNDER DESCRIPTION. Report prepared on 11/5/2021 8:42:54 AM _ Inspection Card Planning &Development Services Permit # : 2010-0290 Building & Code Regulation Division Online address: 2300 Virginia Avenue http://www.stlucieco.org/planning/permitting.htm Fort Pierce, FL. 34982 Quick Links: Phone:(772)462-2172 Fax:(772)462-6443 Permit Status LookupOnline Building Inspection System Page 2 of 3 nspection Notes: Permit # Code Description Priori Sched. Date Res Description Inspector Insp. Date 2010-0290 900 PLAN REVISION 0 9/13/2021 92 Accepted as Debbie Isenhour 9/13/2021 noted CHANGED RETURN LINES FROM 2 1/2" TO 2" 2010-0290 105 FORM BOARD SURVEY - OFFICE 1 2/18/2021 92 Accepted as Angela Vassar g 2/18/2021 noted 2010-0290 187 REVISION PICKED UP 1 9/13/2021 92 Accepted as Office 9/13/2021 noted PICKED UP BY DANNY GARCIA. 2010-0290 113 ANGLE OF REPOSE 2 3/5/2021 93 Not Required Clyde Heffelfinger 3/5/2021 2010-0290 188 MAIN DRAIN TEST 2 3/5/2021 81 Disapproved Clyde Heffelfinger 3/5/2021 No test. FBC 110.5 2010-0290 188 MAIN DRAIN TEST 2 3/30/2021 90 Approved Clyde Heffelfinger 3/30/2021 REINSPECTION. 2010-0290 189 DRAIN TEST 2 3/5/2021 81 Disapproved Clyde Heffelfinger 3/5/2021 FBC110.5. No test 2010-0290 189 DRAIN TEST 2 3/30/2021 90 Approved Clyde Heffelfinger 3/30/2021 REINSPECTION. POOL STEEL & Disapproved- 2010-0290 190 GROUND 2 3/5/2021 82 Reinspect Fee Clyde Heffelfinger 3/5/2021 Required There are no grounding connections made. Four locations around the pool perimeter are required per plan. FBC107.4 2010-0290 190 POOL STEEL & GROUND 2 3/30/2021 90 Approved Clyde Heffelfinger 3/30/2021 REINSPECTION. 2010-0290 191 POOL STEEL 2 3/5/2021 81 Disapproved Clyde Heffelfinger 3/5/2021 FBC110.5. Some steel is covered with dirt. There is standing water in the hole. There is grass beginning to grow in some places. Disapproved- 2010-0290 191 POOL STEEL 2 3/30/2021 82 Reinspect Fee Clyde Heffelfinger 3/30/2021 Required REINSPECTION ....... There is water standing in the pool that has to be pumped out. There still is grass growing inside the pool needs to be removed Cancelled by 2010-0290 191 POOL STEEL 2 3/31/2021 75 Contractor/Custo Clyde Heffelfinger 3/31/2021 mer REINSPECTION. Disapproved- 2010-0290 191 POOL STEEL 2 4/1/2021 82 Reinspect Fee Clyde Heffelfinger 4/1/2021 Required Corrections not made. Cancelled by 2010-0290 191 POOL STEEL 2 4/7/2021 75 Contractor/Gusto Clyde Heffelfinger 4/7/2021 mer REINSPECTION. Disapproved- 2010-0290 191 POOL STEEL 2 4/8/2021 82 Reinspect Fee Clyde Heffelfinger 4/8/2021 Required Report prepared on 11/5/2021 8:42:54 AM 17 Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462.2172 Fax:(772)462-6443 Inspection Card Permit # : 2010-0290 Online address: http://www.stlucieco.org/planning/permiffing.htm Quick Links: Permit Status Lookup Online Building Inspection System REINSPECTION ...... Remove the grass from inside the pool.R318.6.2 2010-0290 191 POOL STEEL 2 4/19/2021 90 Approved Andy Wentz REINSPECTION. 4/19/2021 COMPACTION TEST - 2010-0290 104 ORIGINAL - TURN INTO 3 OFFICE 2010-0290 417 POOL UNDERGROUND 3 9/3/2021 81 PIPING Disapproved Andy Wentz 9/3/2021 Missing skimmers, piping not per drawing. Drawings don't show return locations. 107.4 FBC 2010-0290 417 POOL UNDERGROUND 3 9/14/2021 81 PIPING Disapproved Wanda Gahn 9/15/2021 REINSPECTION. Piping wasn't completely installed. See previous inspection notes 2010-0290 417 POOL UNDERGROUND 3 9/22/2021 81 PIPING Disapproved Wanda Gahn 9/22/2021 pp Returns are not to plan. Piping for jets are not installed no sizing forjet piping on plan. All returns cannot be seen due to water in spa. dirt has washed in over piping could not check all runs. 2010-0290 417 POOL UNDERGROUND 3 PIPING REINSPECTION. 2010-0290 123 STAIRS (CONCRETE, 4 STEEL & WOOD) 2010-0290 216 DECK BOND 4 2010-0290 217 POOL BOND 4 2010-0290 413 PLUMBING - PIPE TEST 4 2010-0290 184 FINAL SURVEY - OFFICE 5 2010-0290 194 ALARM/POOL BARRIER 6 2010-0290 196 POOL/SPA COVER 6 2010-0290 197 PAVER DECK 6 2010-0290 219 POOL FINAL ELECTRIC 6 2010-0290 237 ELECTRIC BOND 6 2010-0290 238 ELECTRIC ROUGH 6 2010-0290 251 ALARM FINAL 6 2010-0290 419 POOL PLUMBING FINAL 6 2010-0290 999 FINAL INSPECTION 6 DO NOT FINAL WITHOUT THE FENCE ENCLOSURE PERMIT Total Inspections: 36 Report prepared on 11/5/2021 8:42:54 AM