Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED MANJ (3)
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Aug-27 10:37:00 Right-Suite® Universal 2021 21.0.08 RSU29066 Page 1 ...ments\Wrightsoft HVAC\2962 Bent Pine Dr GBI.rup Calc = MJ8 Front Door faces: N 1603Job:Load Short Form 8/25/2021Date:House Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Wright Residence, Groza Builders, IncFor: 2962 Bent Pine Dr, Fort Pierce, FL 34951 Design Information InfiltrationClgHtg SimplifiedMethod9041Outside db (°F) AverageConstruction quality7570Inside db (°F) 0Fireplaces1529Design TD (°F) L-Daily range 5030Inside humidity (%) 572Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Make Lennox Trade Trade LENNOX Model Cond ML14XC1S036-230C** AHRI ref Coil CBA27UHE-036-230*++TDR AHRI ref 204289057 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input kW7.9 Sensible cooling Btuh24220 Heating output Btuh26993 Latent cooling Btuh10380 Temperature rise °F21 Total cooling Btuh34600 Actual air flow cfm1153 Actual air flow cfm1153 Air flow factor cfm/Btuh0.041 Air flow factor cfm/Btuh0.053 Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 0.73 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Bath 83 620 186 25 10 Bath 2 81 1778 500 73 27 Bed 2 166 2833 1768 116 94 Bed 3 208 1735 921 71 49 Bed 4 197 3041 1674 124 89 Den 121 1352 860 55 46 Flex Room 156 2791 1717 114 91 Foyer 89 689 276 28 15 Great Room 445 2267 4485 93 239 Hall 45 0 0 0 0 Hall 2 40 0 0 0 0 Hers 42 647 173 26 9 His 37 595 158 24 8 Kit Nook 353 2086 4166 85 222 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Aug-27 10:37:00 Right-Suite® Universal 2021 21.0.08 RSU29066 Page 2 ...ments\Wrightsoft HVAC\2962 Bent Pine Dr GBI.rup Calc = MJ8 Front Door faces: N Laundry 75 1360 911 56 48 M Bath 162 1470 407 60 22 M Hall 20 0 0 0 0 Master Bed 259 4824 3393 197 181 Pantry 36 48 26 2 1 Wtr Clst 26 34 19 1 1 Wtr Clst2 23 30 17 1 1 House 2663 28199 21654 1153 1153 Other equip loads 2044 1085 Equip. @ 0.95 RSM 21694 Latent cooling 8415 TOTALS 2663 30243 30109 1153 1153 2021-Aug-27 10:37:00 Right-Suite® Universal 2021 21.0.08 RSU29066 Page 1 ...ments\Wrightsoft HVAC\2962 Bent Pine Dr GBI.rup Calc = MJ8 Front Door faces: N 1603Job:Building Analysis 8/25/2021Date:House Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Wright Residence, Groza Builders, IncFor: 2962 Bent Pine Dr, Fort Pierce, FL 34951 Design Conditions Location: CoolingHeatingIndoor:7570Indoor temperature (°F)St Lucie Co Intl, FL, US 1529Design TD (°F)ft26Elevation: 5030Relative humidity (%)°N28Latitude: Outdoor:56.92.4Moisture difference (gr/lb)CoolingHeating Infiltration:9041Dry bulb (°F) SimplifiedMethod)L(15-Daily range (°F) AverageConstruction quality77-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing Other Ceilings Floors Infiltration Ducts Ventilation % of loadBtuhBtuh/ft²Component 15.647212.6Walls 7.823569.0Glazing 0.61693.7Doors 8.726291.0Ceilings 23.270272.62.6Floors 13.641012.3Infiltration 23.87195Ducts 00Piping 00Humidification 6.82044Ventilation0Adjustments 100.030243Total Cooling Walls Glazing Other Ceilings Infiltration Ducts Internal Gains Ventilation % of loadBtuhBtuh/ft²Component 12.728861.6Walls 23.0522220.0Glazing 0.81713.7Doors 7.116140.6Ceilings 000Floors 4.810890.6Infiltration 22.75173Ducts 4.81085Ventilation 24.25500Internal gains 00Blower 0Adjustments 100.022740Total Latent Cooling Load = 8415 Btuh Overall U-value = 0.079 Btuh/ft²-°F Data entries checked. 2021-Aug-27 10:37:00 Right-Suite® Universal 2021 21.0.08 RSU29066 Page 1 ...ments\Wrightsoft HVAC\2962 Bent Pine Dr GBI.rup Calc = MJ8 Front Door faces: N 1603Job:Component Constructions 8/25/2021Date:House Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Wright Residence, Groza Builders, IncFor: 2962 Bent Pine Dr, Fort Pierce, FL 34951 Design Conditions Location: CoolingHeatingIndoor: 7570Indoor temperature (°F)St Lucie Co Intl, FL, US 1529Design TD (°F)ft26Elevation: 5030Relative humidity (%)°N28Latitude: Outdoor:56.92.4Moisture difference (gr/lb)CoolingHeating Infiltration:9041Dry bulb (°F) SimplifiedMethod)L(15-Daily range (°F) AverageConstruction quality77-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLoss Clg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls Block R-9 Wall: Blk wall, Stuc Ext, 8" thk, R-9 Foam Fill, 1/2" Gyp Bd 8202.589.00.089318n 5241.65 4221.656602.589.00.089256e 8171.6512772.589.00.089496s 6611.6510332.589.00.089401w 24241.6537892.589.00.0891471all Partitions Frm Wall, 1/2" Gyp Bd Ext, R-11 Cav Ins, 1/2" Gyp Bd Int Fnsh, 2"x4", 16" OC Stud 4621.469312.9411.00.101317 Windows Impact: Impact; NFRC rated (SHGC=0.21); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (0.67 ft window ht, 1 ft sep.); 6.8 ft head ht 127.17158.7000.3002n Impact: Impact; NFRC rated (SHGC=0.21); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (5.2 ft window ht, 1 ft sep.); 6.8 ft head ht 2247.172718.7000.30031n 34322.01368.7000.30016e 68622.02718.7000.30031e 1459.311368.7000.30016s 34322.01368.7000.30016w 174115.99508.7000.300109all Impact: Impact; NFRC rated (SHGC=0.21); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (5.25 ft window ht, 1 ft sep.); 6.8 ft head ht 51022.02028.7000.30023e Impact: Impact; NFRC rated (SHGC=0.21); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 7.3 ft overhang (5.2 ft window ht, 1 ft sep.); 6.8 ft head ht 2979.512718.7000.30031w Impact: Impact; NFRC rated (SHGC=0.26); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (8 ft window ht, 1 ft sep.); 6.8 ft head ht 90818.94599.5700.33048w Impact: Impact; NFRC rated (SHGC=0.26); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 9.3 ft overhang (8 ft window ht, 1 ft sep.); 6.8 ft head ht 61612.84599.5700.33048w Doors 2021-Aug-27 10:37:00 Right-Suite® Universal 2021 21.0.08 RSU29066 Page 2 ...ments\Wrightsoft HVAC\2962 Bent Pine Dr GBI.rup Calc = MJ8 Front Door faces: N Fbrgls Door 673.73663.697.00.12718n 1043.731033.697.00.12728e 1713.731693.697.00.12746all Ceilings Attic, Metal Roof, R-30 Ceil Ins, 5/8" Gyp Bd 0.0342663 16140.6126290.9930.0 Floors On Grade Depth, Tile Flr Fnsh 00702728.700.989245 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Aug-27 10:37:00 Right-Suite® Universal 2021 21.0.08 RSU29066 Page 1 ...ments\Wrightsoft HVAC\2962 Bent Pine Dr GBI.rup Calc = MJ8 Front Door faces: N 1603Job:Project Summary 8/25/2021Date:House Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Wright Residence, Groza Builders, IncFor:2962 Bent Pine Dr, Fort Pierce, FL 34951 Notes: Design Information St Lucie Co Intl, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F41 Outside db °F90Inside db °F70 Inside db °F75 Design TD °F29 Design TD °F15Daily range L Relative humidity %50Moisture difference gr/lb57 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh21004 Structure Btuh16481 Ducts Btuh7195 Ducts Btuh5173Central vent (64 cfm) 2044 Btuh Central vent (64 cfm) Btuh1085 Outside air Outside airHumidification Btuh0 Blower Btuh0 Piping Btuh0Equipment load Btuh30243 Use manufacturer's data n Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh21694 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh3487 Ducts Btuh2451Central vent (64 cfm) Btuh2478 CoolingHeating Outside air26632663Area (ft²) Equipment latent load Btuh8415 2413024130Volume (ft³)Air changes/hour 0.160.32 Equipment Total Load (Sen+Lat)Btuh30109 Equiv. AVF (cfm) 64129 Req. total capacity at 0.70 SHR ton2.6 Heating Equipment Summary Cooling Equipment Summary Make Make LennoxTrade Trade LENNOX Model Cond ML14XC1S036-230C**AHRI ref Coil CBA27UHE-036-230*++TDR AHRI ref 204289057Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input kW7.9 Sensible cooling Btuh24220Heating output Btuh26993 Latent cooling Btuh10380 Temperature rise °F21 Total cooling Btuh34600Actual air flow cfm1153 Actual air flow cfm1153 Air flow factor cfm/Btuh0.041 Air flow factor cfm/Btuh0.053Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 0.73 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Aug-27 10:37:00Right-Suite® Universal 2021 21.0.08 RSU29066 Page 1...ments\Wrightsoft HVAC\2962 Bent Pine Dr GBI.rup Calc = MJ8 Front Door faces: N 1603Job:Right-J® Worksheet 8/25/2021Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name House Bath 2 Exposed wall 245.0 ft 5.5 ft 3 Room height 9.1 ft 8.0 heat/coolft 4 Room dimensions ft5.5x15.0 5 Room area 2662.5 ft²82.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nn 2.582.58 1.651.65 369 318 820 524 0 0 0 0 .GG ImpactImpact 0.3000.300 nn 8.708.70 7.177.17 2 0 15 12 0 0 0 0 .GG ImpactImpact 0.3000.300 nn 8.708.70 7.177.17 31 0 271 224 0 0 0 0 .DD Fbrgls DoorFbrgls Door 0.1270.127 nn 3.693.69 3.733.73 18 18 66 67 0 0 0 0 11 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ee 2.582.58 1.651.65 354 256 660 422 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 16 0 136 343 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 31 0 271 686 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 23 0 202 510 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ee 3.693.69 3.733.73 28 28 103 104 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ss 2.582.58 1.651.65 511 496 1277 817 44 44 113 73 GG ImpactImpact 0.3000.300 ss 8.708.70 9.319.31 16 13 136 145 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 1.651.65 544 401 1033 661 0 0 0 0 GG ImpactImpact 0.3000.300 ww 8.708.70 21.9921.99 16 0 136 343 0 0 0 0 GG ImpactImpact 0.3000.300 ww 8.708.70 9.519.51 31 30 271 297 0 0 0 0 GG ImpactImpact 0.3300.330 ww 9.579.57 18.9218.92 48 0 459 908 0 0 0 0 GG ImpactImpact 0.3300.330 ww 9.579.57 12.8412.84 48 40 459 616 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 317 317 931 462 0 0 0 0 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 2663 2663 2629 1614 83 83 81 50 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 2663 245 7027 0 83 6 158 0 6 c) AED excursion 1137 -12 Envelope loss/gain 16902 9892 353 110 12 a) Infiltration 4101 1089 102 27 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 5 1150 0 0 Appliances/other 4350 0 Subtotal (lines 6 to 13)21004 16481 454 137 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 8 4 14 Subtotal 21004 16481 462 141 15 Duct loads 34%31%7195 5173 34%31%158 44 Total room load 28199 21654 620 186 Air required (cfm)Air required (cfm)1153 1153 25 10 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Aug-27 10:37:00Right-Suite® Universal 2021 21.0.08 RSU29066 Page 2...ments\Wrightsoft HVAC\2962 Bent Pine Dr GBI.rup Calc = MJ8 Front Door faces: N 1603Job:Right-J® Worksheet 8/25/2021Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Bath 2 Bed 2 2 Exposed wall 18.0 ft 26.5 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft9.5x8.5 ft165.8x1.0 5 Room area 80.8 ft²165.8 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nn 2.582.58 1.651.65 76 58 150 96 0 0 0 0 .GG ImpactImpact 0.3000.300 nn 8.708.70 7.177.17 0 0 0 0 0 0 0 0 .GG ImpactImpact 0.3000.300 nn 8.708.70 7.177.17 0 0 0 0 0 0 0 0 .DD Fbrgls DoorFbrgls Door 0.1270.127 nn 3.693.69 3.733.73 18 18 66 67 0 0 0 0 11 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ee 2.582.58 1.651.65 0 0 0 0 92 69 177 113 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 0 0 0 0 23 0 202 510 DD Fbrgls DoorFbrgls Door 0.1270.127 ee 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ss 2.582.58 1.651.65 0 0 0 0 120 120 309 198 GG ImpactImpact 0.3000.300 ss 8.708.70 9.319.31 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 1.651.65 68 68 175 112 0 0 0 0 GG ImpactImpact 0.3000.300 ww 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ww 8.708.70 9.519.51 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3300.330 ww 9.579.57 18.9218.92 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3300.330 ww 9.579.57 12.8412.84 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 81 81 80 49 166 166 164 100 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 81 18 516 0 166 27 760 0 6 c) AED excursion -34 39 Envelope loss/gain 987 289 1612 960 12 a) Infiltration 332 88 489 130 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 250 Subtotal (lines 6 to 13)1319 378 2101 1340 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 5 3 9 5 14 Subtotal 1324 380 2110 1345 15 Duct loads 34%31%454 119 34%31%723 422 Total room load 1778 500 2833 1768 Air required (cfm)Air required (cfm)73 27 116 94 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Aug-27 10:37:00Right-Suite® Universal 2021 21.0.08 RSU29066 Page 3...ments\Wrightsoft HVAC\2962 Bent Pine Dr GBI.rup Calc = MJ8 Front Door faces: N 1603Job:Right-J® Worksheet 8/25/2021Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Bed 3 Bed 4 2 Exposed wall 14.5 ft 29.0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft207.5x1.0 ft197.4x1.0 5 Room area 207.5 ft²197.4 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nn 2.582.58 1.651.65 0 0 0 0 0 0 0 0 .GG ImpactImpact 0.3000.300 nn 8.708.70 7.177.17 0 0 0 0 0 0 0 0 .GG ImpactImpact 0.3000.300 nn 8.708.70 7.177.17 0 0 0 0 0 0 0 0 .DD Fbrgls DoorFbrgls Door 0.1270.127 nn 3.693.69 3.733.73 0 0 0 0 0 0 0 0 11 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ee 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ee 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ss 2.582.58 1.651.65 116 100 259 165 124 124 319 204 GG ImpactImpact 0.3000.300 ss 8.708.70 9.319.31 16 13 136 145 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 1.651.65 0 0 0 0 108 92 238 152 GG ImpactImpact 0.3000.300 ww 8.708.70 21.9921.99 0 0 0 0 16 0 136 343 GG ImpactImpact 0.3000.300 ww 8.708.70 9.519.51 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3300.330 ww 9.579.57 18.9218.92 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3300.330 ww 9.579.57 12.8412.84 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 208 208 205 126 197 197 195 120 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 208 15 416 0 197 29 832 0 6 c) AED excursion -62 57 Envelope loss/gain 1015 374 1720 876 12 a) Infiltration 268 71 535 142 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 250 250 Subtotal (lines 6 to 13)1283 696 2255 1268 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 9 5 10 6 14 Subtotal 1292 701 2265 1274 15 Duct loads 34%31%443 220 34%31%776 400 Total room load 1735 921 3041 1674 Air required (cfm)Air required (cfm)71 49 124 89 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Aug-27 10:37:00Right-Suite® Universal 2021 21.0.08 RSU29066 Page 4...ments\Wrightsoft HVAC\2962 Bent Pine Dr GBI.rup Calc = MJ8 Front Door faces: N 1603Job:Right-J® Worksheet 8/25/2021Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Den Flex Room 2 Exposed wall 11.5 ft 25.0 ft 3 Room height 8.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft10.5x11.5 ft156.0x1.0 5 Room area 120.8 ft²156.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nn 2.582.58 1.651.65 0 0 0 0 0 0 0 0 .GG ImpactImpact 0.3000.300 nn 8.708.70 7.177.17 0 0 0 0 0 0 0 0 .GG ImpactImpact 0.3000.300 nn 8.708.70 7.177.17 0 0 0 0 0 0 0 0 .DD Fbrgls DoorFbrgls Door 0.1270.127 nn 3.693.69 3.733.73 0 0 0 0 0 0 0 0 11 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ee 2.582.58 1.651.65 92 76 197 126 120 89 229 146 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 16 0 136 343 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 0 0 0 0 31 0 271 686 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ee 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ss 2.582.58 1.651.65 0 0 0 0 25 25 64 41 GG ImpactImpact 0.3000.300 ss 8.708.70 9.319.31 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ww 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ww 8.708.70 9.519.51 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3300.330 ww 9.579.57 18.9218.92 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3300.330 ww 9.579.57 12.8412.84 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 105 105 308 153 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 121 121 119 73 156 156 154 95 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 121 12 330 0 156 25 717 0 6 c) AED excursion 49 97 Envelope loss/gain 782 591 1744 1218 12 a) Infiltration 212 56 335 89 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)994 647 2079 1307 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 13 7 0 0 14 Subtotal 1007 655 2079 1307 15 Duct loads 34%31%345 206 34%31%712 410 Total room load 1352 860 2791 1717 Air required (cfm)Air required (cfm)55 46 114 91 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Aug-27 10:37:00Right-Suite® Universal 2021 21.0.08 RSU29066 Page 5...ments\Wrightsoft HVAC\2962 Bent Pine Dr GBI.rup Calc = MJ8 Front Door faces: N 1603Job:Right-J® Worksheet 8/25/2021Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Foyer Great Room 2 Exposed wall 5.0 ft 10.5 ft 3 Room height 10.0 heat/coolft 11.5 heat/coolft 4 Room dimensions ft88.5x1.0 ft444.8x1.0 5 Room area 88.5 ft²444.8 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nn 2.582.58 1.651.65 0 0 0 0 0 0 0 0 .GG ImpactImpact 0.3000.300 nn 8.708.70 7.177.17 0 0 0 0 0 0 0 0 .GG ImpactImpact 0.3000.300 nn 8.708.70 7.177.17 0 0 0 0 0 0 0 0 .DD Fbrgls DoorFbrgls Door 0.1270.127 nn 3.693.69 3.733.73 0 0 0 0 0 0 0 0 11 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ee 2.582.58 1.651.65 50 22 57 36 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ee 3.693.69 3.733.73 28 28 103 104 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ss 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ss 8.708.70 9.319.31 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 1.651.65 0 0 0 0 121 73 187 120 GG ImpactImpact 0.3000.300 ww 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ww 8.708.70 9.519.51 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3300.330 ww 9.579.57 18.9218.92 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3300.330 ww 9.579.57 12.8412.84 0 0 0 0 48 40 459 616 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 89 89 87 54 445 445 439 270 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 89 5 143 0 445 11 301 0 6 c) AED excursion -19 731 Envelope loss/gain 391 176 1387 1737 12 a) Infiltration 115 31 279 74 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 3 690 Appliances/other 0 900 Subtotal (lines 6 to 13)506 206 1666 3400 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 7 4 23 13 14 Subtotal 513 210 1688 3413 15 Duct loads 34%31%176 66 34%31%578 1071 Total room load 689 276 2267 4485 Air required (cfm)Air required (cfm)28 15 93 239 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Aug-27 10:37:00Right-Suite® Universal 2021 21.0.08 RSU29066 Page 6...ments\Wrightsoft HVAC\2962 Bent Pine Dr GBI.rup Calc = MJ8 Front Door faces: N 1603Job:Right-J® Worksheet 8/25/2021Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Hall Hall 2 2 Exposed wall 0 ft 0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft4.5x10.0 ft39.9x1.0 5 Room area 45.0 ft²39.9 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nn 2.582.58 1.651.65 0 0 0 0 0 0 0 0 .GG ImpactImpact 0.3000.300 nn 8.708.70 7.177.17 0 0 0 0 0 0 0 0 .GG ImpactImpact 0.3000.300 nn 8.708.70 7.177.17 0 0 0 0 0 0 0 0 .DD Fbrgls DoorFbrgls Door 0.1270.127 nn 3.693.69 3.733.73 0 0 0 0 0 0 0 0 11 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ee 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ee 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ss 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ss 8.708.70 9.319.31 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ww 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ww 8.708.70 9.519.51 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3300.330 ww 9.579.57 18.9218.92 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3300.330 ww 9.579.57 12.8412.84 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 45 45 44 27 40 40 39 24 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 45 0 0 0 40 0 0 0 6 c) AED excursion -2 -2 Envelope loss/gain 44 25 39 22 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)44 25 39 22 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -44 -25 -39 -22 14 Subtotal 0 0 0 0 15 Duct loads 34%31%0 0 34%31%0 0 Total room load 0 0 0 0 Air required (cfm)Air required (cfm)0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Aug-27 10:37:00Right-Suite® Universal 2021 21.0.08 RSU29066 Page 7...ments\Wrightsoft HVAC\2962 Bent Pine Dr GBI.rup Calc = MJ8 Front Door faces: N 1603Job:Right-J® Worksheet 8/25/2021Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Hers His 2 Exposed wall 6.5 ft 6.0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft6.5x6.5 ft37.0x1.0 5 Room area 42.3 ft²37.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nn 2.582.58 1.651.65 52 52 134 86 48 48 124 79 .GG ImpactImpact 0.3000.300 nn 8.708.70 7.177.17 0 0 0 0 0 0 0 0 .GG ImpactImpact 0.3000.300 nn 8.708.70 7.177.17 0 0 0 0 0 0 0 0 .DD Fbrgls DoorFbrgls Door 0.1270.127 nn 3.693.69 3.733.73 0 0 0 0 0 0 0 0 11 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ee 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ee 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ss 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ss 8.708.70 9.319.31 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ww 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ww 8.708.70 9.519.51 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3300.330 ww 9.579.57 18.9218.92 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3300.330 ww 9.579.57 12.8412.84 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 42 42 42 26 37 37 37 22 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 42 7 186 0 37 6 172 0 6 c) AED excursion -12 -11 Envelope loss/gain 362 99 332 91 12 a) Infiltration 120 32 111 29 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)482 131 443 120 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 482 131 443 120 15 Duct loads 34%31%165 41 34%31%152 38 Total room load 647 173 595 158 Air required (cfm)Air required (cfm)26 9 24 8 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Aug-27 10:37:00Right-Suite® Universal 2021 21.0.08 RSU29066 Page 8...ments\Wrightsoft HVAC\2962 Bent Pine Dr GBI.rup Calc = MJ8 Front Door faces: N 1603Job:Right-J® Worksheet 8/25/2021Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Kit Nook Laundry 2 Exposed wall 13.0 ft 18.0 ft 3 Room height 10.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft353.4x1.0 ft6.5x11.5 5 Room area 353.4 ft²74.8 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nn 2.582.58 1.651.65 0 0 0 0 0 0 0 0 .GG ImpactImpact 0.3000.300 nn 8.708.70 7.177.17 0 0 0 0 0 0 0 0 .GG ImpactImpact 0.3000.300 nn 8.708.70 7.177.17 0 0 0 0 0 0 0 0 .DD Fbrgls DoorFbrgls Door 0.1270.127 nn 3.693.69 3.733.73 0 0 0 0 0 0 0 0 11 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ee 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ee 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ss 2.582.58 1.651.65 20 20 52 33 0 0 0 0 GG ImpactImpact 0.3000.300 ss 8.708.70 9.319.31 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 1.651.65 110 79 203 130 0 0 0 0 GG ImpactImpact 0.3000.300 ww 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ww 8.708.70 9.519.51 31 30 271 297 0 0 0 0 GG ImpactImpact 0.3300.330 ww 9.579.57 18.9218.92 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3300.330 ww 9.579.57 12.8412.84 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 144 144 423 210 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 353 353 349 214 75 75 74 45 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 353 13 373 0 75 18 516 0 6 c) AED excursion 254 -62 Envelope loss/gain 1248 928 1013 193 12 a) Infiltration 300 80 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 2 460 0 0 Appliances/other 1700 500 Subtotal (lines 6 to 13)1548 3167 1013 693 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 6 3 0 0 14 Subtotal 1554 3171 1013 693 15 Duct loads 34%31%532 995 34%31%347 218 Total room load 2086 4166 1360 911 Air required (cfm)Air required (cfm)85 222 56 48 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Aug-27 10:37:00Right-Suite® Universal 2021 21.0.08 RSU29066 Page 9...ments\Wrightsoft HVAC\2962 Bent Pine Dr GBI.rup Calc = MJ8 Front Door faces: N 1603Job:Right-J® Worksheet 8/25/2021Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name M Bath M Hall 2 Exposed wall 15.5 ft 0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft162.3x1.0 ft4.5x4.5 5 Room area 162.3 ft²20.3 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nn 2.582.58 1.651.65 56 54 140 90 0 0 0 0 .GG ImpactImpact 0.3000.300 nn 8.708.70 7.177.17 2 0 15 12 0 0 0 0 .GG ImpactImpact 0.3000.300 nn 8.708.70 7.177.17 0 0 0 0 0 0 0 0 .DD Fbrgls DoorFbrgls Door 0.1270.127 nn 3.693.69 3.733.73 0 0 0 0 0 0 0 0 11 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ee 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ee 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ss 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ss 8.708.70 9.319.31 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ww 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ww 8.708.70 9.519.51 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3300.330 ww 9.579.57 18.9218.92 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3300.330 ww 9.579.57 12.8412.84 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 68 68 200 99 0 0 0 0 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 162 162 160 98 20 20 20 12 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 162 16 445 0 20 0 0 0 6 c) AED excursion -28 -1 Envelope loss/gain 959 272 20 11 12 a) Infiltration 129 34 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1088 306 20 11 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 7 4 -20 -11 14 Subtotal 1095 310 0 0 15 Duct loads 34%31%375 97 34%31%0 0 Total room load 1470 407 0 0 Air required (cfm)Air required (cfm)60 22 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Aug-27 10:37:00Right-Suite® Universal 2021 21.0.08 RSU29066 Page 10...ments\Wrightsoft HVAC\2962 Bent Pine Dr GBI.rup Calc = MJ8 Front Door faces: N 1603Job:Right-J® Worksheet 8/25/2021Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Master Bed Pantry 2 Exposed wall 40.5 ft 0 ft 3 Room height 8.3 heat/coolft 8.0 heat/coolft 4 Room dimensions ft259.1x1.0 ft9.0x4.0 5 Room area 259.1 ft²36.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nn 2.582.58 1.651.65 137 106 272 174 0 0 0 0 .GG ImpactImpact 0.3000.300 nn 8.708.70 7.177.17 0 0 0 0 0 0 0 0 .GG ImpactImpact 0.3000.300 nn 8.708.70 7.177.17 31 0 271 224 0 0 0 0 .DD Fbrgls DoorFbrgls Door 0.1270.127 nn 3.693.69 3.733.73 0 0 0 0 0 0 0 0 11 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ee 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ee 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ss 2.582.58 1.651.65 62 62 160 103 0 0 0 0 GG ImpactImpact 0.3000.300 ss 8.708.70 9.319.31 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 1.651.65 137 89 229 147 0 0 0 0 GG ImpactImpact 0.3000.300 ww 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ww 8.708.70 9.519.51 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3300.330 ww 9.579.57 18.9218.92 48 0 459 908 0 0 0 0 GG ImpactImpact 0.3300.330 ww 9.579.57 12.8412.84 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 259 259 256 157 36 36 36 22 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 259 41 1162 0 36 0 0 0 6 c) AED excursion 160 -2 Envelope loss/gain 2810 1872 36 20 12 a) Infiltration 775 206 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 500 0 Subtotal (lines 6 to 13)3586 2578 36 20 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 7 4 0 0 14 Subtotal 3593 2582 36 20 15 Duct loads 34%31%1231 810 34%31%12 6 Total room load 4824 3393 48 26 Air required (cfm)Air required (cfm)197 181 2 1 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Aug-27 10:37:00Right-Suite® Universal 2021 21.0.08 RSU29066 Page 11...ments\Wrightsoft HVAC\2962 Bent Pine Dr GBI.rup Calc = MJ8 Front Door faces: N 1603Job:Right-J® Worksheet 8/25/2021Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Wtr Clst Wtr Clst2 2 Exposed wall 0 ft 0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft6.5x4.0 ft6.5x3.5 5 Room area 26.0 ft²22.8 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nn 2.582.58 1.651.65 0 0 0 0 0 0 0 0 .GG ImpactImpact 0.3000.300 nn 8.708.70 7.177.17 0 0 0 0 0 0 0 0 .GG ImpactImpact 0.3000.300 nn 8.708.70 7.177.17 0 0 0 0 0 0 0 0 .DD Fbrgls DoorFbrgls Door 0.1270.127 nn 3.693.69 3.733.73 0 0 0 0 0 0 0 0 11 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ee 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ee 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ss 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ss 8.708.70 9.319.31 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ww 8.708.70 21.9921.99 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ww 8.708.70 9.519.51 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3300.330 ww 9.579.57 18.9218.92 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3300.330 ww 9.579.57 12.8412.84 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 26 26 26 16 23 23 22 14 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 26 0 0 0 23 0 0 0 6 c) AED excursion -1 -1 Envelope loss/gain 26 14 22 13 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)26 14 22 13 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 26 14 22 13 15 Duct loads 34%31%9 5 34%31%8 4 Total room load 34 19 30 17 Air required (cfm)Air required (cfm)1 1 1 1 2021-Aug-27 10:37:01 Right-Suite® Universal 2021 21.0.08 RSU29066 Page 1 ...ments\Wrightsoft HVAC\2962 Bent Pine Dr GBI.rup Calc = MJ8 Front Door faces: N 1603Job:Duct System Summary 8/25/2021Date:House Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Wright Residence, Groza Builders, IncFor: 2962 Bent Pine Dr, Fort Pierce, FL 34951 CoolingHeating External static pressure in H2O0.70in H2O0.70 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.70in H2O0.70 Supply / return available pressure 0.529 / 0.171 in H2O in H2O0.529 / 0.171 Lowest friction rate in/100ft0.255in/100ft0.255 Actual air flow cfm1153cfm1153 Total effective length (TEL) ft274 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk st5140.062.2VlFx0x04.00.2621230620hBath st6140.067.5VlFx0x06.00.25532871778hBath 2 st5140.066.8VlFx0x07.00.2561131392833hBed 2 st6140.062.8VlFx0x06.00.26159851735hBed 3 st6140.062.7VlFx0x07.00.2611071493041hBed 4 st5140.058.0VlFx0x05.00.26755661352hDen st3120.044.4VlFx0x06.00.3221101372791hFlex Room st5140.063.2VlFx0x04.00.2611834689hFoyer st1100.038.0VlFx0x06.00.384143562242cGreat Room st1100.033.8VlFx0x06.00.396143562242cGreat Room-A st295.017.8VlFx0x04.00.4691132647hHers st295.013.4VlFx0x04.00.4881029595hHis st1100.032.4VlFx0x06.00.400133512083cKit Nook st1100.038.9VlFx0x06.00.381133512083cKit Nook-A st3120.042.5VlFx0x05.00.32658671360hLaundry st295.011.3VlFx0x05.00.49826721470hM Bath st7125.039.5VlFx0x06.00.3221081182412hMaster Bed st7125.038.5VlFx0x06.00.3241081182412hMaster Bed-A st3120.038.8VlFx0x04.00.3332248hPantry st3120.042.5VlFx0x04.00.3261234hWtr Clst st295.012.0VlFx0x04.00.4951130hWtr Clst2 Bold/italic values have been manually overridden 2021-Aug-27 10:37:01 Right-Suite® Universal 2021 21.0.08 RSU29066 Page 2 ...ments\Wrightsoft HVAC\2962 Bent Pine Dr GBI.rup Calc = MJ8 Front Door faces: N Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st3 Peak AVF 208 171 0.322 777 7.0 0x0 VinlFlx st1 st5 Peak AVF 270 197 0.256 610 9.0 0x0 VinlFlx st4 st6 Peak AVF 322 198 0.255 728 9.0 0x0 VinlFlx st4 st4 Peak AVF 591 395 0.255 753 12.0 0x0 VinlFlx st1 st1 Peak AVF 1013 1119 0.255 801 16.0 0x0 VinlFlx st7 Peak AVF 237 217 0.322 678 8.0 0x0 VinlFlx st2 st2 Peak AVF 371 265 0.322 841 9.0 0x0 VinlFlx Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb1 0x 7130 867 66.8 0.255 621 16.0 x0 0 VlFx rb2 0x 2980 238 0 0 0 0 x0 0 VlFx rb5 0x 1490 107 0 0 0 0 x0 0 VlFx rb4 0x 850 59 0 0 0 0 x0 0 VlFx rb6 0x 1390 113 0 0 0 0 x0 0 VlFx 2021-Aug-27 10:37:01 Right-Suite® Universal 2021 21.0.08 RSU29066 Page 1 ...ments\Wrightsoft HVAC\2962 Bent Pine Dr GBI.rup Calc = MJ8 Front Door faces: N 1603Job:Manual S Compliance Report 8/25/2021Date:House Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Wright Residence, Groza Builders, IncFor: 2962 Bent Pine Dr, Fort Pierce, FL 34951 Cooling Equipment Design Conditions °F76.4Entering coil DB:Btuh22740Sensible gain:°F90.4Outdoor design DB: °F64.0Entering coil WB:Btuh8415Latent gain:°F77.4Outdoor design WB: Btuh31155Total gain:°F75.0Indoor design DB: cfm1153Estimated airflow:%50Indoor RH: Manufacturer's Performance Data at Actual Design Conditions Split ACEquipment type: ML14XC1S036-230C**+CBA27UHE-036-230*++TDRModel:LennoxManufacturer: cfm1153Actual airflow: % of load107Btuh24220Sensible capacity: % of load123Btuh10380Latent capacity: %70SHR:% of load111Btuh34600Total capacity: Heating Equipment Design Conditions °F67.8Entering coil DB:Btuh30243Heat loss:°F41.0Outdoor design DB: °F70.0Indoor design DB: Manufacturer's Performance Data at Actual Design Conditions Elec stripEquipment type: Model:Manufacturer: cfm1153Actual airflow: °F50Temp. rise:% of load89kW7.9Output capacity: Meets all requirements of ACCA Manual S.