HomeMy WebLinkAboutAPPROVED REVISED A42020 FLORIDA BUILDING CODE - RESIDENTIAL 7th EDITIONBASIC WIND SPEED :RISK CATEGORY :NOMINAL WIND SPEED :FLOOD ZONE :INTERNAL PRESSURE COEFFICEINT :EXPOSURE CATAGORY :STRUCTURAL FORCES :FLOOR LIVE LOAD :ROOF LIVE LOAD :FLOOR DEAD LOAD :ROOF DEAD LOAD :ROOF SLOPE :MEAN ROOF HEIGHT :COMPONANTS & CLADDINGDEIGN PRESSURES:ZONE 1 :ZONE 2 :ZONE 3 :ZONE 4 :ZONE 5 :DOOR & WINDOWWIND PRESSURE DESIGN LOADINGWINDOWSOUTSWINGING DOORSSECTIONAL GARAGE DOOR170 MPHl l(vasd): 132 MPHZONE X+ /- 0.18C40 PSF30 PSF30 PSF25 PSF5 / 1211'-6" AFG+23.3 / -37.0+23.3 / -64.4+23.3 / -95.2+40.3 / -43.7+40.3 / -54.2+40.3 / -43.7+38.5 / -41.9+27 / -30RIGHT ELEVATIONSCALE:14'' = 1'-0''0'-0'' Finish FloorROOFFinish Grade12'-1'' Truss Bearing (Entry)8'-1'' Truss Bearing (Main)4'' SCOREDSTUCCOBANDS125TOP OF WINDOWS TO FASCIA=11-3/16'' +/- W/2X4 END RAILREAR ELEVATIONSCALE:14'' = 1'-0''0'-0'' Finish FloorFinish Grade8'-1'' Truss Bearing (Main)6'-9"TEXTUREDSTUCCOFINISHTEXTUREDSTUCCOFINISHTEXTUREDSTUCCOFINISHTEXTUREDSTUCCOFINISHLEFT ELEVATIONSCALE:14'' = 1'-0''0'-0'' Finish FloorFinish Grade8'-1'' Truss Bearing (Main)FRONT ELEVATIONSCALE:14'' = 1'-0''0'-0'' Finish FloorFinish Grade12'-1'' Truss Bearing (Entry)8'-1'' Truss Bearing (Main)ROOFMETALROOFMETALROOF125125125TOP OF WINDOWS TO FASCIA=11-3/16'' +/- W/2X4 END RAILTOP OF WINDOWS TO FASCIA=11-3/16'' +/- W/2X4 END RAILTOP OF WINDOWS TO FASCIA=11-3/16'' +/- W/2X4 END RAILMETALMETAL10'-1'' Truss Bearing (FLEX RM)0'-0'' Finish FloorFinish Grade8'-1'' Truss Bearing (Main)12'-1'' Truss Bearing (Entry)0'-0'' Finish FloorFinish Grade8'-1'' Truss Bearing (Main)0'-0'' Finish FloorFinish Grade8'-1'' Truss Bearing (Main)19'-4 1/4'' TOP OF ROOF19'-4 1/4'' TOP OF ROOF19'-4 1/4'' TOP OF ROOF0'-0'' Finish FloorFinish Grade8'-1'' Truss Bearing (Main)19'-4 1/4" TOP OF ROOFTYPOH2'-0"TYPOH2'-0"TYPOH2'-0"TYPOH2'-0"14'-6 13/16" T.O. ROOF (Entry)2'-0"+ 36.2- 39.4+ 36.2- 39.4+ 36.2- 39.4+ 37.5- 41.0+ 36.3- 39.7+ 37.5- 41.0+ 36.3- 39.7+ 38.9- 42.3+ 39.2- 42.6+ 39.2- 42.6+ 39.2- 42.6+ 39.2- 42.6+ 39.2- 51.7+ 27- 30+ 35.9- 45.18MAGNOLIA RJW REBEKAH & JULIAN WRIGHT 2962 BENT PINE DR. FT. PIERCE, FL 34951 511 SW PORT SAINT LUCIE BLVD. PORT ST. LUCIE, FL 349531/4" = 1'-0"MAGNOLIA RJW_WRIGHT-PERMIT SET 2022-01-11.dwgA4ELEVATION5SHEETDESCRIPTIONDATEREVBuilder:Project:SCALE:OFMODELOWNERDESIGN BYCHECKED BY1234567808/18/21CHRISTOPHER D. BEERS, P.E.FLORIDA LICENSE NO. 64594W A T E R - A I R - L A N D524 W Virginia Ave.Punta Gorda, Florida 33950941-628-0635fax 413-687-9013chrisbeers@byu.net