Loading...
HomeMy WebLinkAboutSolar Star RM-2400 Roof Vent REVISIONSOLATUBE SOLAR STAR HIGH PROFILE RU--2400 ROOF VENT INSTALLATIONANCHORAGE DETAILS GENERAL NOTES: INSTALLATION NOTES: 1. THE PRODUCT ANCHORAGE SHOWN HEREIN IS DESIGNED TO COMPLY WITH THE CURRENT EDITION OF THE 1. ONE (1) INSTALLATION ANCHOR IS REQUIRED AT EACH ANCHOR LOCATION SHOWN ON SHEETS 2 AND 3. FLORIDA BUILDING CODE (FBC) INCLUDING ITS SUPPLEMENTS AND INCLUDING 'THE HIGH VELOCITY HURRICANE ZONE (HVHZ) AT THE DESIGN PRESSURES STATED HEREIN. 24GERMIS R n I .� D>=PICTFn IS_.;= _ MBER_• F AN. QR5 TO_BE_ _SE 2. THE PRODUCT DETAILS CONTAINED HEREIN ARE BASED UPON SIGNED AND SEALED ATI TEST REPORT C1439.01-109-18-RO, ATI TEST REPORT C1439.02-109-18-RO AND ASSOCIATED LABORATORY STAMPED DRAWINGS. 3. TESTING SUMMARY 3.1. THE PRODUCT HAS BEEN STRUCTURALLY TESTED TO TAS-202-94 (ATI TEST REPORT C1439.02-109-18-RO) AND FOUND TO BE IN CONFORMANCE TO THE CURRENT EDITION OF THE FLORIDA BUILDING CODE (FBC). THE DESIGN PRESSURES SHOWN IN DESIGN PRESSURE RATING TABLE ON SHEET 1 OF THIS DRAWING ARE BASED ON THE RESULTS OF TEST REPORT NO. C1439.02-109-18-RO DIVIDED BY A FACTOR OF SAFETY OF 2. 3.2. THE PRODUCT HAS BEEN TESTED FOR W IND-DRIVEN RAIN RESISTANCE TO TAS-100(A)-95 (ATI TEST REPORT C1439.01-109-18-RO). SUBSEQUENT STRUCTURAL TESTING FOR INCREASED WINDSPEED RESISTANCE FOR VENTS EXCEEDING DIMENSIONAL LIMITATIONS OF SECTION 10.4.1 OF TAS-100(A)-95 WAS PERFORATED TO TAS-202.94 (ABOVE). AS DOCUMENTED IN PRODUCT EVALUATION REPORT NO. 1906. AN INSTALLATION HEIGHT NOT TO EXCEED 75 FEET IS APPLICABLE. 4. PLASTIC COMPONENTS OF THE SOLATUBE SOLAR STAR ROOF VENT HAVE BEEN EVALUATED TO THE REQUIREMENTS OF THE CURRENT EDITION OF THE FLORIDA BUILDING CODE AND ARE IN COMPLIANCE AS DOCUMENTED IN PRODUCT EVALUATION REPORT NO. 1906 BY ROBERT J. AMORUSO, P.E. 5. ADEQUACY OF THE EXISTING STRUCTURAL ROOF SHEATHING AND SUPPORTING 2X FRAMING AS A MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF WITHSTANDING AND TRANSFERRING APPLIED PRODUCT LOADS TO THE FOUNDATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF INSTALLATION. 6. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE REQUIREMENTS DETAILED HEREIN. A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT. 7. THE SOLAR STAR'S PRIMARY COMPONENTS ARE COMPRISED OF THE FOLLOWING MATERIALS: 7.1. FLASHING AND TOP PANEL: ALU44INZED STEEL EDDS TI-25 (TYPE 1) 7.2. STANDOFF, lox 1 x 74: ALUMINUM 6051-T6 7.3. HVHZ SPRING CLIP: 301 STAINLESS STEEL 7A. FAN GRILL: POLYPROPYLENE THIS PRODUCT EVALUATION DOCUMENT ADDRESSES THE STRUCTURAL ATTACHMENT OF THE ROOF VENT TO THE ROOF SHEATHING ONLY. PREPARATION OF THE ROOF SHEATHING AND ROOF COVERING(S) TO RECEIVE THE ROOF VENT SHALL BE PER THE MANUFACTURER'S INSTRUCTIONS. THIS APPROVAL IS FOR THE STRUCTURAL PERFORMANCE ONLY. IMPACT RESISTANCE WAS NOT -(TESTED. INTERIOR MECHANISM ANWOR ELECTRICAL CIRCUITRY ARE OUTSIDE THE SCOPE brTHIS-PRODDCT APPROVAL DOCUMENT. .'.:.d TABLE OF CONTENTS SHEET DESCRIPTION 1 GENERAL AND INSTALLATION NOTES 2 ELEVATION, ANCHORING AND SECTIONS' �---/ 3 COMPONENTS I=---r-�-'•. 4 BILL OF MATERIALS AND ISOMETERIC VIEW 2.3. DESIGN PRESSURE RATING TABLE BELOW DETAILS TOTAL ANCHOR QUANTITIES BASED ON DESIGN PRESSURE AND SUBSTRATE TYPE (PLYWOOD SPECIES OR OSB). 3.4. MAXIMUM UPLIFT DESIGN PRESSURE OF -170 PSF BASED ON PERFORMANCE TESTING IS NOT EXCEEDED. POSITIVE Z DOWNWARD DESIGN PRESSURE OF -50 PSF IS NOT LIMITED BY ANCHOR QUANTITY. 1i'1 > I.S. SEE VENT TOP VIEW ON SHEETS 2 AND 3, _ 0 3. FOR INSTALLATION INTO PLYWOODIOSB ROOFING, USE NO. 10, TYPE AB, PAN HEAD, ROUND HEAD OR TRUSS HEAD CORROSION RESISTANT STEEL TAPPING SCREWS MEETING ASME/ANSI B18.6.4 OF SUFFICIENT LENGTH TO ACHIEVE FULL ry� tD N DEPTH OF EMBEDMENT INTO PLYWOOD/OSB SHEATHING A MINIMUM OF 15/32' INCH IN THICKENESS. EDGE DISTANCE FROM W �, O CENTERLINE OF SCREW TO EDGE OF PLYVI'OOD/OSB SHALL BE AT LEAST 1-1/4 INCH. c O S 4. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE ROOF FINISHES. E a :!5 N � 5. INSTALLATION ANCHORS MUST BE MADE OF CORROSION RESISTANT MATERIAL OR HAVE A CORROSION RESISTANT a m COATING. O d:1 J O U rm 80 6. INSTALLATION ANCHOR CAPACITIES FOR PRODUCTS HEREIN ARE BASED ON SUBSTRATE MATERIALS WITH THE FOLLOWING O0 PROPERTIES: 02 y- d 6A. 15/32' THICK PLYWOOD -SPECIES GROUP 1 OR 2 (APA VOLUNTARY PRODUCT STANDARD PSI) MINIMUM, p-, _ 6.1.1. FOR PLYWOOD SPECIES NOT MEETING SPECIES GROUP 1 OR 2, SEE NOTE 2.2 ABOVE FOR ADDITIONAL ANCHORAGE r O REQUIREMENTS. 6:2.2. LIMITATIONS AS THEY APPLY TO PLYWOOD IN THE HVHZ PER THE FLORIDA BUILDING CODE AND/OR JURISDICTIONAL 2 REQUIREMENTS SHALL BE MET. 6.3. 15132' OSB -SHEATHING GRADE (APA VOLUNTARY PRODUCT STANDARD PS 2) MINIMUM. 6.3.1. LIMITATIONS AS THEY .APPLY TO OSB IN THE HVHZ PER THE FLORIDA BUILDING CODE AND/OR JURISDICTIONAL y REQUIREMENTS SHALL BE MET. E 7. ADDITIONAL INSTALLTION LIMITATIONS .I. PRODUCT SHA L E INSTALLED ATAN ELEVATION EXCEEDING 75 FET. PRODUCT SHALL NSTALLED ON ROOF SHEATHING LESS THAN 15132' IN THICKNESS. -..r. PRODUCT SH IN ALLED ON ROOFS UTLIZING ASPHALT SHINGLES OR HIGH -PROFILE ROOF TILES NOT EXCEEDING THREE INCH IGHT, DESIGN PRESSURE RATING (PSF) PLYWOOD SPECIES GROUP ANCHOR QUANTITY NEGATIVE UPLIFT (PSF) POSITIVE DOWNWARD (PSF) 8 -152 50 1 16 -170 50 8 -106 50 2 16 -170 50 8 -84 50 3, 4, 5 16 -170 50 8 -106 50 OSB 16 1 -170 150 Robert J. Amoruso, P.E. FL P.E. No. 49752 5 Il%rM'i,'-' Digitally'signed by Robert J Annoruso Date: 2018.02.07 11.:5035-05'00' SOLAR STAR RM-2400 HIGH PROFILE VENT FLASHING CAP SHEET (OPTIONAL) SEALANT ROOFING MATERIAL 15/32" MIN. EMBEDMENT 15/32" PLYWOOD/OSB J ROOFING MINIMUM #10 PAN, ROUND OR TRUSS HD TAPPING SCREW SECTION A INSTALLATION ANCHOR: CORNERS, 8X MIN. REQUIF SEE INSTALLATION NOTE 2 SHEE INSTALLATION ANCHORS AT MID -SPAN, 8X MIN. REQUIRED. SEE INSTALLATION NOTE 2 ON SHEET 1. INSTALLATION) (SEE INST, NOTES ON DETAIL C 4.: SOLAR STAR RM-2400 HIGH PROFILE VENT TOP VIEW clln._TT117►T n n m c� Q o+ � N O � r a n o a o o o o c �t�o �Z 006� Z OF .. ui d > V o Ch . Ll m it O In W a co N0o Q v 3 c Z -w � cv PQ Boa>� E, q :5 pNZ'S �a`v) I E �o 0 d �. lD W Z US o�Z N Q rnd� a S T. Robert J. Amoruso, P.E. FL RE. No. 49752 OOWN,� IJ!!4 .j4O��•. t� n `.o= Z. Digitally"Mgned by Robert .Amoruso- Date: 2018.02.07 11.50:51-05'00' 14.36" �{ 6" �- 25.30" FLASHING 14" NO PITCH 6" 1 ` ALUMINIZED STEEL EDDS Tl-2_S .028" THICK .75" O 7 02 1.9" j4 - �I I-1.89" n SPRING CLIP HVH_Z 301 STAINLESS STEEL.020" THICK //// VOAF 22.47"� 2.67'. �11.76 FAN GRILL, SOLAR STAR 14" 2" POLYPROPYLENE, .120•• THICK 2.92 ° --{ 1 STANDOFF, lOxlx74 ALUMINUM 6061-T6.039" THICK 20.582" 7.0" 18.2" 0.135'�— RM-2400 SOLAR PANEL TYPICAL CONFIGURATION SHOWN ABOVE,. SOLAR PANEL LAYOUT MAY VARY. TOP PANEL SS 14" BLACK OALUMINIZED STEEI. EDDS T1-25.028" THICK H °° .1 W F d > o F w U M 3 m W F w � oL'3 �m E1pNZ a�1 I d " M �o3Z>J� U) 12"02 oaf N d v) m I s L Robert J. Amoruso, P.E. FL P.E. No, 49752 Digitally signed by Robert �.•�eS�CE43'�G� Amoruso 'Date: Iv- 2018 02 Q7 11:51:02 -05'00' 4 m a o e o t\ _ T R n 00 2 g N F 16 0 � o a r w no 4 ® /� 11 aim 8 I 7 ® e �� �/ 3 c=51G 12 zj m0F� M- >�o m FiW nor 0 1 3oM o ' m �\�` 3 =` �° oL>� g�o: �z ---� H a Z o N z 5 m a% 14 a x O w D tv) 15 d Cv Q o 4 mwg m uj a 5 6 �oogoQ � Cc) 13 C v) a- y 2 m o� o `e t g 1 12 � 1 Robert J. Amoruso, P.E. � FL P.E. No. 49752 ISO METRIC VIEW ,•o$SNC:JA�GILAya Digitally signed by Robed`)-Amoruso . Date: 2018.02.07 T151:17-05'00' ITEM QTY. PART DESCRIPTION 1 4 503101 STANDOFF, lOX1X74 2 1 590020 FAN GRILL, SOLAR STAR 14" 3 1 590030 TOP PANEL, SS 14" BLACK 4 1 590210 SOLAR PANEL35W 5 1 590100 SOLAR STAR MOTOR 6 1 592010 SOLAR STAR FAN BLADE 7 4 600201 FOAM PAD, PSA 8 4 700210 SCREW, SEAL 8-32 X 5/16 SS 9 4 700280 ROOF SEALANT BLACK 10 1 700510 COMPRESSION RING 11 8 700661 RIVET OPEN END BLIND 6.4 X20 12 1 230445 FLASHING 14" NO PITCH 6" HIGH 13 b 520020 HVHZ SPRING CLIP 14 6 700910 WASHER #b EPDM RUBBER 15 b 700125 SCREW #8 DRILLTIPSS W/WASHER 16 1 700035 SOLAR STAR SEAL PV PANEL 17 1 504320 SOLAR STAR BASE FASTENER KIT (NOT SHOWN) 18 1 590155 LABEL, SOLAR STAR (NOT SHOWN) 19 1 803610 BUBBLE WRAP FILM (NOT SHOWN) 20 1 830580 BOX, 25-5/8" X 5-7/8" X 25-5/8" (NOT SHOWN) 21 1 830605 BOX PITCHED SOLAR STAR (NOT SHOWN) 22 4 830615 SOLAR STAR FOAM INSERT (NOT SHOWN) 23 1 950910 PRODUCT OWNERSHIP AND CARE GUIDE (NOT SHOWN) 24 1 951900 SOLAR STAR INSTALLATION INSTRUCTIONS (NOT SHOWN)