HomeMy WebLinkAboutFinn Residence - Energy 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 71/21/2021 10:40 AM
Project Name:
Owner:
Builder Name:
Permit Office:
Jurisdiction: St. Lucie County
St. Lucie County
Jason & Lisa Finn
Finn Residence
Street:
City, State, Zip: Fort Pierce , FL , 34981
TBD S 25th Street
Permit Number:
Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (ft²)
New (From Plans)
Detached
1
No
2415
7. Windows
a. U-Factor:
S H G C :
b. U-Factor:
S H G C :
c. U-Factor:
S H G C :
Sgl, U=0.65 322.00 ft²
SHGC=0.25
N/A f t ²
N/A f t ²
9. Floor Types
a. Slab-On-Grade Edge Insulation
b. N/A
c. N/A
R=0.0 2415.00 ft²
R=f t ²
R=f t ²
10. Wall Types
a. Concrete Block - Int Insul, Exterior R=5.0 2465.00 ft²
b. Frame - Wood, Adjacent R=11.0 250.00 ft²
c. N/A R=f t ²
11. Ceiling Types
a. Roof Deck (Unvented)R=20.0 2415.00 ft²
f t ² R=b. N/A
c. N/A R = f t ²
12. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
13. Cooling systems
14. Heating systems
15. Hot water systems
a. Propane Cap: 1 gallons
b. Conservation features
None
d. N/A R=f t ²
Area Weighted Average Overhang Depth:5.416 ft.
Area Weighted Average SHGC:0.250
Description Area
Insulation Area
Insulation Area
Insulation Area
16. Credits CF, Pstat
3
(322.0 sqft.)
(2715.0 sqft.)
(2415.0 sqft.)
(2415.0 sqft.)
Conditioned floor area below grade (ft²) 0
a. Central Unit
a. Electric Strip Heat
k B t u / h r
46.5 SEER:17.00
Efficiency
k B t u / h r Efficiency
34.0 COP:1.00
f t ² R
6 90
Tankless
EF: 0.600
8. Skylights
c. U-Factor:(AVG)
S H G C ( A V G ) :
N/A
N/A
f t ²
Area
Glass/Floor Area: 0.133
Total Proposed Modified Loads:
Total Baseline Loads:
74.53
78.45 PASS
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code.
PREPARED BY:
DATE:
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT:
DATE:
BUILDING OFFICIAL:
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
FORM R405-2020
1-21-2021
PROJECT
Title:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction: St. Lucie County
St. Lucie County
1
Jason & Lisa Finn
Finn Residence
Family Type:
New/Existing:
Bedrooms:
Conditioned Area:
Total Stories:
Worst Case:
Rotate Angle: 0
No
1
2415
3
New (From Plans)
Detached
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
FL , 34981
Fort Pierce ,
St. Lucie
TBD S 25th Street
Street Address
Comment:
Building Type: User
Cross Ventilation: No
Whole House Fan: No
TMY Site
Design Temp Int Design Temp Heating Design Daily Temp
Design Location 2.5 %97.5 % Degree Days Moisture RangeWinter Summer
CLIMATE
90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______
Number Name Area Volume
BLOCKS
1 Entire House 2415 24888
Number Name Area Volume
SPACES
Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished
1 Master Suite 313 3443 No 2 1 Yes Yes1 Yes
2 WIC 1 78 780 No 0 Yes Yes1 Yes
3 Toilet 24 240 No 0 Yes Yes1 Yes
4 M Bath 212 2120 No 0 Yes Yes1 Yes
5 M WIC 2 36 360 No 0 Yes Yes1 Yes
6 Foyer 80 800 No 0 Yes Yes1 Yes
7 Great Room 425 4675 No 2 Yes Yes1 Yes
8 Dining 156 1560 No 1 Yes Yes1 Yes
9 Laundry 117 1170 No 0 Yes Yes1 Yes
10 Hall 2 48 480 No 0 Yes Yes1 No
11 Bedroom 3 156 1560 No 1 1 Yes Yes1 Yes
12 WIC 2 37 370 No 0 Yes Yes1 Yes
13 Pantry 54 540 No 0 Yes Yes1 No
14 Bedroom 2 165 1650 No 1 1 Yes Yes1 Yes
15 Bath2 109 1090 No 0 Yes Yes1 Yes
16 Hall 99 990 No 0 Yes Yes1 No
17 WIC 3 36 360 No 0 Yes Yes1 Yes
18 Bath 3 66 660 No 0 Yes Yes1 Yes
19 Kitchen 204 2040 Yes 2 Yes Yes1 No
1/21/2021 10:40 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
1 313 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -33 ft Master Suite
2 78 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -13 ft WIC 1
3 24 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -4 ft Toilet
4 212 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -40 ft M Bath
5 36 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -6 ft WIC 2
6 80 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -16 ft Foyer
7 427 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -22 ft Great Room
8 156 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -25 ft Dining
9 117 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -15 ft Laundry
10 48 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -1 ft Hall 2
11 156 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -12 ft Bedroom 3
12 36 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -6 ft WIC 2
13 54 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -1 ft Pantry
14 165 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -11 ft Bedroom 2
15 108 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -9 ft Bath2
16 99 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -1 ft Hall
17 36 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -12 ft WIC 3
18 66 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -17 ft Bath 3
19 204 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -1 ft Kitchen
# Type Materials Color Absor.
Roof Solar Deck
Insul.
Pitch
ROOF
Tested
Roof
Area
Gable
Area
Emitt
Tested
EmittSA
(deg)
Rad
Barr
1 Hip Metal 2616 ft² Medium 0.6 20 22.62______ No0 ft² 0.9 NoN
ATTIC
# Type Ventilation Area RBS IRCCVent Ratio (1 in)
______ 1 Full attic Unvented 2415 ft² N N0
1/21/2021 10:40 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
# Ceiling Type R-Value Area Framing Frac Truss Type
CEILING
Space Ins Type
1 Under Attic (Unvented) 0 313 ft² 0.1 Wood______ Master Suite Blown
2 Under Attic (Unvented) 0 78 ft² 0.1 Wood______ WIC 1 Blown
3 Under Attic (Unvented) 0 24 ft² 0.1 Wood______ Toilet Blown
4 Under Attic (Unvented) 0 212 ft² 0.1 Wood______ M Bath Blown
5 Under Attic (Unvented) 0 36 ft² 0.1 Wood______ WIC 2 Blown
6 Under Attic (Unvented) 0 80 ft² 0.1 Wood______ Foyer Blown
7 Under Attic (Unvented) 0 427 ft² 0.1 Wood______ Great Room Blown
8 Under Attic (Unvented) 0 156 ft² 0.1 Wood______ Dining Blown
9 Under Attic (Unvented) 0 117 ft² 0.1 Wood______ Laundry Blown
10 Under Attic (Unvented) 0 48 ft² 0.1 Wood______ Hall 2 Blown
11 Under Attic (Unvented) 0 156 ft² 0.1 Wood______ Bedroom 3 Blown
12 Under Attic (Unvented) 0 36 ft² 0.1 Wood______ WIC 2 Blown
13 Under Attic (Unvented) 0 54 ft² 0.1 Wood______ Pantry Blown
14 Under Attic (Unvented) 0 165 ft² 0.1 Wood______ Bedroom 2 Blown
15 Under Attic (Unvented) 0 108 ft² 0.1 Wood______ Bath2 Blown
16 Under Attic (Unvented) 0 99 ft² 0.1 Wood______ Hall Blown
17 Under Attic (Unvented) 0 36 ft² 0.1 Wood______ WIC 3 Blown
18 Under Attic (Unvented) 0 66 ft² 0.1 Wood______ Bath 3 Blown
19 Under Attic (Unvented) 0 204 ft² 0.1 Wood______ Kitchen Blown
WALLS
# Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
1 5 0Master Suite 0001 11N Concrete Block - Int Insul 0.60Exterior 11.0 ft² ____
2 5 0Master Suite 00016 11S Concrete Block - Int Insul 0.60Exterior 176.0 ft² ____
3 5 0Master Suite 00016 11W Concrete Block - Int Insul 0.60Exterior 176.0 ft² ____
4 5 0WIC 1 00013 10S Concrete Block - Int Insul 0.60Exterior 130.0 ft² ____
5 5 0Toilet 0004 10S Concrete Block - Int Insul 0.60Exterior 40.0 ft² ____
6 5 0M Bath 00014 10N Concrete Block - Int Insul 0.60Exterior 140.0 ft² ____
7 5 0M Bath 00016 10E Concrete Block - Int Insul 0.60Exterior 160.0 ft² ____
8 5 0M Bath 00010 10S Concrete Block - Int Insul 0.60Exterior 100.0 ft² ____
9 5 0WIC 2 0006 10N Concrete Block - Int Insul 0.60Exterior 60.0 ft² ____
10 5 0Foyer 00016 10E Concrete Block - Int Insul 0.60Exterior 160.0 ft² ____
11 5 0Great Room 00022 11W Concrete Block - Int Insul 0.60Exterior 242.0 ft² ____
12 5 0Dining 00012 10S Concrete Block - Int Insul 0.60Exterior 120.0 ft² ____
13 5 0Dining 00013 10W Concrete Block - Int Insul 0.60Exterior 130.0 ft² ____
14 5 0Laundry 00011 10E Concrete Block - Int Insul 0.60Exterior 110.0 ft² ____
15 5 0Laundry 0004 10S Concrete Block - Int Insul 0.60Exterior 40.0 ft² ____
16 5 0Bedroom 3 00012 10N Concrete Block - Int Insul 0.60Exterior 120.0 ft² ____
17 5 0WIC 2 0006 10N Concrete Block - Int Insul 0.60Exterior 60.0 ft² ____
18 5 0Bedroom 2 00011 10N Concrete Block - Int Insul 0.60Exterior 110.0 ft² ____
19 5 0Bath2 0009 10N Concrete Block - Int Insul 0.60Exterior 90.0 ft² ____
20 5 0WIC 3 0006 10N Concrete Block - Int Insul 0.60Exterior 60.0 ft² ____
21 5 0WIC 3 0006 10W Concrete Block - Int Insul 0.60Exterior 60.0 ft² ____
1/21/2021 10:40 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
# Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
22 5 0Bath 3 0006 10S Concrete Block - Int Insul 0.60Exterior 60.0 ft² ____
23 5 0Bath 3 00011 10W Concrete Block - Int Insul 0.60Exterior 110.0 ft² ____
24 11 0Laundry 2 10E Frame - Wood 0.60.23Garage 20.0 ft² ____
25 11 0Hall 11 10E Frame - Wood 0.60.23Garage 110.0 ft² ____
26 11 0Bath2 12 10E Frame - Wood 0.60.23Garage 120.0 ft² ____
# Door Type U-Value AreaStorms
DOORS
Ornt Space
Width
Ft In Ft In
Height
1 Insulated .39 48 ft² None______ E Foyer 86
2 Insulated .39 22.7 ft² None______ S Bath 3 8102
3 Insulated .39 24 ft² None______ E Hall 83
# Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening
WINDOWS
Overhang
Orientation shown is the entered, Proposed orientation.
Wall
ID Imp
1 S Low-E Single 0.65 0.25 20.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______ Yes2 Y
2 W Low-E Single 0.65 0.25 48.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______ Yes3 Y
3 E Low-E Single 0.65 0.25 30.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______ Yes7 Y
4 E Low-E Single 0.65 0.25 30.0 ft² 10 ft 0 in 1 ft 4 in NoneMetal None______ Yes10 Y
5 W Low-E Single 0.65 0.25 96.0 ft² 10 ft 0 in 1 ft 4 in NoneMetal None______ Yes11 Y
6 S Low-E Single 0.65 0.25 30.0 ft² 4 ft 0 in 1 ft 4 in NoneMetal None______ Yes12 Y
7 W Low-E Single 0.65 0.25 30.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______ Yes13 Y
8 E Low-E Single 0.65 0.25 8.0 ft² 6 ft 0 in 1 ft 4 in NoneMetal None______ Yes14 Y
9 N Low-E Single 0.65 0.25 15.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______ Yes16 Y
10 N Low-E Single 0.65 0.25 15.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______ Yes18 Y
# Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
GARAGE
1 550 ft² 550 ft² 25 ft 10 ft 11______
Method CFM 50 ACH 50ELASLAScope
INFILTRATION
ACHEqLA#
2903.6 7159.3.000458Wholehouse .1398299.07Proposed ACH(50)1
1/21/2021 10:40 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type Efficiency Capacity DuctsSubtype BlockSpeed
1 Electric Strip Heat/ COP:1 34 kBtu/hr ______ sys#1None 1
# System Type Efficiency Capacity Air Flow SHR
COOLING SYSTEM
DuctsSubtype BlockSubtype
1 Central Unit/ SEER: 17 46.5 kBtu/hr c f m 0.7______ sys#1Split 1 Singl
# System Type EF Cap Use SetPnt Conservation
HOT WATER SYSTEM
SubType Location
1 Propane 0.6 1 gal 60.9 gal 120 deg None______ Tankless Exterior
FSEC
Company Name System Model # Collector Model #
Collector
SOLAR HOT WATER SYSTEM
Storage
FEFCert # Area Volume
None None f t ² ______
# Location R-Value Area Location Area
---- Supply ---- ---- Return ----
Leakage Type Handler
CFM 25Air
QN RLF
DUCTS
Heat Cool
HVAC #
TOT OUT
CFM25
1 Attic 6 90 ft² Attic 25 ft² Default Leakage Attic ( D e f a u l t ) ______ 1 1 ( D e f a u l t )
TEMPERATURES
Programable Thermostat: Y Ceiling Fans:
Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec
[ ] Dec[X] Dec[X] Nov[X] Nov[ ] Oct[X] Oct[ ] Sep[ ] Sep[ ] Aug[ ] Aug[ ] Jul[ ] Jul[ ] Jun[ ] Jun[X] Jun[ ] May[ ] May[ ] Apr[X] Apr[X] Mar[X] Mar[X] Feb[ ] Feb[X] Jan[ ] JanHeatingVenting
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling (WD) AMPM 7880 7880 7878 7878 7878 7878 7878 7878 8078 8078 8078 8078
Cooling (WEH) AMPM 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878
Heating (WD) AMPM 6668 6668 6668 6668 6668 6868 6868 6868 6868 6868 6866 6866
Heating (WEH) AMPM 6668 6668 6668 6668 6668 6868 6868 6868 6868 6868 6866 6866
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 lbs/sq.ft. 0 ft² 0 ft 0.3 Master Suite
Default(8 lbs/sq.ft. f t ² f t 0.3 WIC 1
Default(8 lbs/sq.ft. f t ² f t 0.3 Toilet
Default(8 lbs/sq.ft. f t ² f t 0.3 M Bath
Default(8 lbs/sq.ft. f t ² f t 0.3 M WIC 2
Default(8 lbs/sq.ft. f t ² f t 0.3 Foyer
Default(8 lbs/sq.ft. f t ² f t 0.3 Great Room
Default(8 lbs/sq.ft. f t ² f t 0.3 Dining
1/21/2021 10:40 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 lbs/sq.ft. f t ² f t 0.3 Laundry
Default(8 lbs/sq.ft. f t ² f t 0.3 Hall 2
Default(8 lbs/sq.ft. f t ² f t 0.3 Bedroom 3
Default(8 lbs/sq.ft. f t ² f t 0.3 WIC 2
Default(8 lbs/sq.ft. f t ² f t 0.3 Pantry
Default(8 lbs/sq.ft. f t ² f t 0.3 Bedroom 2
Default(8 lbs/sq.ft. f t ² f t 0.3 Bath2
Default(8 lbs/sq.ft. f t ² f t 0.3 Hall
Default(8 lbs/sq.ft. f t ² f t 0.3 WIC 3
Default(8 lbs/sq.ft. f t ² f t 0.3 Bath 3
Default(8 lbs/sq.ft. f t ² f t 0.3 Kitchen
1/21/2021 10:40 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 7 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT